Supply Of Lab Equipment To Common Instrumentation Lab Of Govt. Brennen College , Equipment For Centre Of Excellence , Ftir Spectrophotometer-Spectral Range: 8, 000–350 Cm-1 Optimized, Mid-Infrared Kbr Beam-Splitter.Signal-To-Noise: Summit Spectrometer – 35, 000:1 ( Peak-To-Peak, One Minute ) .Wavenumber Precision: 0.001 Cm-1 At 2, 000 Cm-1.Wavenumber Accuracy: 0.05 Cm-1 At 2, 000 Cm-1 Ordinate Linearity ( Astm E1421 ) : <0.15 %T Deviation From 0.0%T.Infrared Source: Non-Migrating Hotspot, Single-Point Source For Unmatched Data Reproducibility.Laser: Solid-State, Temperature Controlled Diode Laser With Long Lifetime. Interferometer: Dynamically Aligned Interferometer With Kbr / Ge Mid-Infrared Beam-Splitter Optimized For Highest Spectral Throughput.Detector: Fast-Recovery Deuterated Triglycine Sulfate ( Dtgs ) . Power Consumption: 100-240 Vac, 47-63 Hz, 110 W.Tightly Sealed And Desiccated Optical Compartment With Protective Kbr Windows For Humidity And Vapor Protection.User-Replaceable Components ( Without Opening Cover ) : Desiccant, Power Supply, Sample Compartment Windows, Infrared Source. Interface / Connections: Mini-Display Port Connection To Monitor, Ethernet Connection To Laptop Computer Light Bar: Multi-Colored Led Bar Displays System Status And Spectral Library Match Value / Qcheck Result.All Optics Should Be Sealed In A Metal Alloy Chassis For Enhanced Durability, Robustness, And Moisture Control. Should Be Provided Internal Nist-Traceable 1.5 Mil Polystyrene Film ( Serialized ) With Traceable Certificate. Should Be Provided Original Licensed Version Library At Least 5000 Spectra. Ftir Must Be Having Cloud Based Connectivity For Remote Access Data. Diagnostic: Continuous Electronic Monitoring Of Multiple Spectrometer Components With Temperature And Humidity Sensors And Diagnostic Status Displayed On Light Bar. Software Capability: Dashboard / Home Screen For Quick Access Of Recent Work, Visual, Drag And Drop Workflow Creator With Example Templates, Live Displays Of Data Collection And Spectral Data Preview, Connectivity To Omnic Anywhere Cloud-Based Application, Smart Background Feature Cuts Measurement Time By 50%, Optional Advanced Instrument Health Information Tracking, Flexible, One-Click Library Creation, Pre-Defined Reporting Templates Exportable To Microsoft Office Suite, Multi-Component Search Functionality. Full Spectral Processing And Analysis Tools ( Baseline Correction, Spectral Math, Peak Area, Peak Height, Etc ) , Quantification Prediction For Beer’S Law, Pls, Cls, Etc. , Automated Workflow Creator Based On Spectral Processing History. Warranty: 3 Year Warranty For Instrument And 5 Years Warranty For Laser And Interferometer. Should Be Provided Kbr Pellet Making Complete Kit. Should Be Provided Branded Latest Version Desktop. Vendor Should Be Provided At Least 5 User List In Kerala. Vendor Should Be Having Service Facility At Kerala, Service Centre Address To Be Furnished. , Spin Coating Unit : Programmable Model Ideal For Scientific Research Works.Ptfe Coated Ss Working Chamber Of 200 Mm Diameter. Programmable Speed Range Of 100-10, 000 R.P.M [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] Programmable Acceleration Period Of 1-250 Seconds [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] . Programmable Acceleration Range Of 40-5, 000 R.P.M / Sec [ Based On A Glass Substrate Of Dimension 38 Mm ( L ) X 25 Mm ( W ) & Thickness 1 Mm ] . Programmable Controlling Duration Range Of 1-9, 999 Sec / Step. Real-Time Display Of R.P.M Vs. Time In 4 Line Lcd Display. 2 User Programs Available, 10 Steps / Program Available, Warm-Up Option Available, Calibration Option Available, Spill Drainage Facility Available. High-Speed Dc Motor For Fast Speed Reaching.Non-Volatile Program Memory, User-Friendly Firmware Interface, N2 & Other Inert Gas Purging Port Available. Integrated Power On / Off Switch Available. Integrated Vacuum Release Switch Available. Transparent Photo-Resist Acrylic Safety Lid Available. Input & Controlling Through Key-Pad. Indian Standard Power Input Vendor Should Be Provided Manufacturer Authorization Certificate.Vendor Should Be Having Service Facility At Kannur Or Nearest Districts, Service Centre Address To Be Furnished. Standard Oil Free Vacuum Pump:- Power: Indian Standard. Vacuum: 560 Mm / Hg. ( Maximum ) . Flow Rate: 15 L / Min. Maximum Operating Pressure: 25 Psi, Horse Power: 1 / 20 Hp, Dimension: 150 Mm X 110 Mm X 140 Mm. Net Weight: 2.5 Kg, No Lubrication Required. Noise Less , Absolutely Portable, Totally Oil-Free Construction, Practically Maintenance-Free. All Parts Made From Special Graded Aluminium Die-Cast Material For Light Weight & Good Strength. Diaphragms Are Made Of Special Type Polynylon & Reinforced Neoprene Rubber Built-In Micro-Suction Filte, Extra-Large Bearings For Trouble-Free & Smooth Running. Warranty : 1 Year , Furnace With Programmable Temperature Controller: Furnace Capacity Will Be 16 Ltrs Or More. Temperature Range Will Be 100°C To 1200°C Or Better. Power Consumption: 4500W Or Less. Thermocouple Type: Platinel Ii Thermocouple Or Better For Long-Term Stability. Will Be Having E Lgo Heating Elements And Moldatherm Insulation For Efficient And Economical Transfer Of Heat To Chamber, With Low Exterior Temperatures. Self-Tuning, Digital Instrumentation For Precise Temperature Setpoint And Display. Air Vent ( 1 In. Dia., Top ) And Air Inlet ( 0.375 In. Dia., Rear ) For Inert Atmosphere Exchange. Microprocessor-Based Self-Tuning Pid Control Provides Optimum Thermal Process, Prevents Overshoot. Adjustable High-Limit Over Temperature Protection. Simultaneous Led Display Of Actual Temperature Vs. Setpoint In °C Or °F. Safety Door Switch Interrupts Power To Heating Element When Door Is Opened; Protects Heating Elements And Minimizes Exposure To End-User. Shelves Will Be A Removable And Easy Cleaning. Controller Type: Digital Single Set Point Controller. Single Segment, Single Set Point, One Ramp To Set Point. Super Control ( Fuzzy Logic ) Suppresses Overshooting Of Temperature. Overrides Main Controller And Shuts Off Power To Furnace If High Limit Is Reached. Operates Via Magnetic Contacts Through Signal From Independent Thermocouple. Furnace Must Have An Optional Rs485 Digital Communications Port Facility. Should Be Provided Two-Way Communications Set Up Between Furnace And Remote Computer. Furnace Must Have The Options Of Remote Monitoring And Control Of Furnace Equipment. Must Have An Ability To Connect Up To 30 Furnaces To One Personal Computer.Certifications: Ul And Ce ( International Certifications ) .Furnace Must Have Globally Accepted Brand. Warranty: 1 Year , Vacuum Oven With Pump- Specification For Vacuum Oven And Pump: Vacuum Oven With Chamber Capacity 30L. Temperature Range Rt+5~200ºc. Vacuum Degree 133Pa Or Better. Inner Chamber Should Be 316 Stainless Steel Mirror Polish. Pid Controller With Led Display, Over Temperature Warning And Timing Function. Square Chamber Design With A Large Dual Layer Tempered Glass On The Door Allows For Excellent Observation. Led Lights On The Door For Easy Viewing Of Sample. Silicon Door Gasket For Long Life And Better Vacuity. Display Resolution 0.1 And Temperature Stability ±1ºc.Minimum 2 Nos. Ss 316 Shelves Power Consumption 850W Or Less Vacuum Pump ? Dual-Stage Rotary Vane Vacuum Vacuum Pump ? Proven Vane Technology Ensures More Stable Performance ? Built In Gear Pump And Constant Pressure Oil Supply System Enable Steady And Dependable Operation Even When Suction Pressure Is High ? Electric Solenoid Valve Ensures That The System Maintains A Vacuumstate When Power Is Turned Off, Hence Preventing Oil Suck Back ? Ultimate Partial Pressure Gas Ballast Close 1×10-1 Pa ? Ultimate Total Pressure Gas Ballast Close 3Pa ? Ultimate Total Pressure Gas Ballast Open 20 ? Level Of Protection Ip44 ? Intake And Exhaust Kf16 ? Motor Speed 1440 Or Better ? The Equipment Ce Certified ? Warranty Two Years Minimum. , Source Meter- With Silver Electrodes Single Electrode Maximum Current Source / Measure Range – 1 A Maximum Voltage Source / Measure Range –20 V Measurement Resolution ( Current / Voltage ) -1Pa / 100Nv Power -20W , Digital Balance-Four Digit Electronic Precision Balance • Capacity: 220G ; Minimum Display: 0.1Mg • Repeatability ( Standard Deviation ) : =0.1Mg • Linearity: ±0.2Mg • Stabilization Time: 3 Seconds Or Less • Operating Temperature And Humidity Limits :5-40°C 20-85%*2 • Temperature Coefficient Forsensitivity ( 10-30°C ) : ± 2 Ppm / °C • Pan Size ( Mm ) Approx.: Ø91 • Main Body Dimensions ( Mm ) Approx.: 213 ( W ) 356 ( D ) 338 ( H ) • Main Body Weight ( Kg ) Approx.: 6.2 • Power Requirement: 12V, 1A • Calibration: Touch Key Internal Calibration • Instrument Should Be An Internationally Accepted Imported Brand. • Vendor Should Be Provided Specific Oem Authorization Certificate. • Usb Port, Rs 232 Facility Available. • In-Built Specific Gravity Software • Certifications: Iso And Ce Certified • Electronic Balance Should Be Multinational Accepted Imported Brand. • Electronic Balance Should Have The Features Of Easy Setting, Expanded Piece Counting Function, • Comparator Function, Formulation Mode, Power Saving Function, Windows Direct Communication Function, Power Lock • Vendor Should Be Provided Specific Manufacturer Authorization Certificate. • Vendor Should Be Having Service Facility At Kerala; Details Of Service Centre Should Be Furnished. • Warranty: 2 Years With Periodic Preventive Inspection Every 3 Months During The Warranty Period , Digital Ph Meter - Metal With Dimensions 15 X 14X 6 Centimetres; Weight 4 Kg; 5Year Warranty , Agate Mortar With Pestle For Laboratory Use Material- Agate Diameter 8-10 Cm , Ultrapure Water Purification System 1 ) Water Purification System Should Be Capable Of Producing 18.2 Megaohm Resistivity With Pre-Treatment Cartridge, Reverse Osmosis And Mixed Bed Ion Exchange Resins And Activated Carbon In A Single Pack, With Feed Water Acceptance Of Upto 2000Micro Siemens Conductivity, Fouling Index ( Sdi ) < 12, Total Chlorine < 1 Ppm. 2 ) All In One Pack Which Contains A Combination Of Technologies To Produce Ultrapure Water From Tap Water Directly. 3 ) The 1St Stage Of The Ro Di Cartridge Contains Pre-Treatment For Reverse Osmosis Followed By Ro Membrane. 4 ) The 2Nd Stage Contains Mixed Bed Ion Exchange Resin And Organex For Removal Of Organic Contaminants. 5 ) It Should Have Only One Cartridge In The System. If The System Comes With More Than One Cartridge Then That Cartridge Should Quote Mandatorily 20 Numbers ( Including Ro ) Along The Main Quote. Need To Furnish Above Mentioned Cartridge Catalogue Number With Quantity In The Technical Bid. 6 ) Type 3 Water Flow Rate Should Be 3 Litre / Hour. Product Waterspecifications Resistivity:18.2Meg Ohm.Cm ( @ 25 Degree C ) Conductivity: < 0.055Us / Cm Toc : <10 Ppb Bacteria :< 0.1 Cfu / Ml Pyrogen : <0.001Eu / Ml Rnase: <0.01 Ng / Ml Flow Rate : 0.5 L / Min Particulates> 0.22U:<1 P / Ml , High Resolution Stereo Zoom Microscope With Camera Optics Carrier; Magnification Range:8X-160X Or More ( 10X Eyepieces And 1X Objective ) Apochromatic Corrected Optics. Maximum Upgradable Magnification 1270X Or More. Should Offer Simultaneous High Resolution And Depth Observation.Zoom Ratio; 20.5:1 Or Better. Eyepiece; 10X / 23B, Dioptre Adjustable, Wide-Field Eyepiece For Spectacle Wearers, Designed For Using Graticules, With Exchangeable Soft Eyecups Base; Incident Light Base, Large With Anti Shock Feet With Stage Insert Black / White ( 120 Mm ) Focus Drive; Motor Focus Drive Long 410Mm Or Above Usb Interface And 3 Can Connectors To Interface Accessories. Illumination ( Led ) ; High Diffuse Illumination Domelight With 2 Independent Controllable Ring Lights, Control Panel Foron / Off, Brightness And Lightcontrols. Tube; Inclined Binocular Tube 45°, Interpupillary Distance 52-76 Mm, Documentation Tubewith Beam Splitting Switchable 0 / 50 / 100 %, Resolution And Working Distance; Maximum Resolution 1050 Lp / Mm, Working Distance 60Mm External Control Unit; Hand Wheel / Smart Touchto Control The Microscope Camera; Dedicated Digital Scientific Grade Camera Capable Of Taking High Resolution Images With Cmos / Ccd Sensor. Minimum 12 Mp Or Better Pixel Dimensions: 1.55 ?M X 1.55 ?M Or Better, 4K 60Fps Live Image Via Hdmi, Jpg Images With Up To 12 Mp Full Hd Mjpg Video Recording With 30 Fps Should Have Upgradation Facility Of Stand Alone Digital Imaging Station Software; Compactable Softwarefor Image Acquisition Full Control Of Camera Features ( Exposure, Gain, Gamma And Region Of Interest. ) . Software Has The Ability To Control Motorization And Z- Stacking. Automatically Capturing A Given Number Of Images And Stitching Together To Get A Perfect 3D Image. Measurement Module For Generating Measurement Parameters Such As Length, Distance, Area, Perimeter, Diameter And Angles. All Measurements Are Displayed In An Interactive Table And Can Be Exported To Excel Or Used To Generate Reports. Computer; I5 64-Bit Processor, 8 Gb Ram, 1Tb Hdd, 1Gb Graphics Card, 24 Inch Monitor, Windows 10 Warranty; 2 Year Warranty And 3Rd Year Amc. All The Components, Microscope, Camera, And Software Should Be Same Make , Ultra Deep Freezer -80 Degree Temperature With Hydrocarbon Refrigerant• Capacity Should Be Minimum 540 Liters Capacity With Minimum 4 Inner Doors • 2" Box Capacity: 400Nos• 2Ml Vial Capacity: 40000 • Temperature Range Should Be -50°C To -86°C• Noise Level: 51 Db Or Below • Energy Consumption ( Kw-Hr / Day ) : 12.3 Or Less• Door Opening Recovery Time Will Be17 Minutes Or Less • Warm-Up Time ( -80°C To -50°C ) Will Be 257 Minutes Or More.• The Freezer Must Be Constructed Using 1” Thick Vacuum Panel Insulation In Conjunction With Environmentally-Friendly Water Blown Foam.• Door Gasket Must Provide 7 Independent Insulation Zones Along With 4 Points Of Contact To Ensure Sample Security. • Freezer Shall Be Painted With High-Impact, Scratch Resistant Powder Coat Finished Interior And Exterior To Ensure Long Term Viability And Enhanced Temperature Uniformity. • To Reduce Condensation, The Perimeter Heater Shall Be On The Door Side Not On The Cabinet Side To Limit Heat Introduction Into The Sample Storage Area. • The Thermal Breaker Shall Be Made Of Plastic To Limit Heat Leakage Into The Cabinet Door Latch Allows One-Handed Opening And Closing. • Handle Must Include Door Key Lock As Well As Padlock Provision For Added Security. • Freezer Shall Have 4 Compartments With A Minimum Of 4 Polystyrene Insulated Inner Doors To Ensure Sample Security. • Inner Doors Should Have No Latches Or External Magnets And Must Be Removable For Easy Cleaning Without The Use Of Tools. • Freezer Shall Have An Automatic Heated Pressure Equalization Port Which Allows For Rapid Re-Entry To Cabinet. • Freezer Shall Have Two-1 Inch Access Ports As Standard. • Freezer Shall Have A Rs485 Output, Dry Contacts And 4-20Ma Output For Remote Monitoring Purposes. Freezer Door Must Open At Least 180 Degrees For Easy Sample Access. • Freezer Shall Incorporate Set Point Security Freezer Interface Shall Incorporate Icons To Advise Users Of Alarm Status For Warm Or Cold Excursions, Door Ajar, Or Power Failure. • Freezer Interface Shall Allow For The Use Of An Off-Set Value To Be Used For Calibration. • Freezer Shall Have The Option Of Either An Liquid Nitrogen Or Carbon Dioxide Back-Up System. • Freezer Shall Have The Option Of A Chart Recorder. • Freezer Shall Record Temperature Excursions Including Actual Temperature, Warmest Temperature And Coldest Temperature. • Freezer Must Recognize If Line Voltage And Frequency Does Not Match Freezer Specification And Alert User. • Refrigeration System - Freezer Shall Use Only Natural, Commercially Available Refrigerants ( Hydrocarbon ) With No Special Blends Required. • Connectivity: External Monitoring / Cloud Compatible; 4-20Ma, Rs485, Dry Contacts • Meets + / -10°C Validation Protocols At -80°C With Strong Peak Variation And Steady-State Temperature Variation • Freezer Must Be Built To And Contain The Registration Mark For Ul, Cul, And Ce Standards For Safety And Performance. • Should Be Fda Class Ii Medical Device Warranty Minimum 5 Years On Complete System From The Manufacturer. • Warranty: 5 Years Vendor Should Be Supplied Suitable 5 Kv Servo Stabiliser , Refrigerated Centrifuge Centrifuge Should Have Maximum Capacity Of 4 X 144 Ml Or More Centrifuge Should Have Maximum Speed 17, 500 Rpm Or More Centrifuge Should Have 30, 000 G Or More Secure, Easy Rotor Exchange Delivers Trouble-Free Rotor Installation / Exchange. The Centrifuge Must Be Compatible With Swinging Bucket Rotor, Fixed Angle Rotor And Microplate Rotorstemperature Range: -10°C To 40°C Noise Level: <56Dba Safety Feature: Rotor Detection System, Imbalance Detection Systemrefrigeration System: Cfc Free Drive System: Direct, Brushless Induction Drive One-Touch Operation With Pre-Saved Protocolsprograms: 3 Or 4 Direct Programs Warranty: 2 Years With Periodic Preventive Inspection On Every 3 Months During Warranty Period3 End User Performance Certificate Should Be Provided Centrifuge Conforms To The Latest Clinical And Safety Standards Such As Ul, Ce And Ivdwill Be Provided The Following Rotors Suitable For High Speed Applications 24 X 1.5 / 2 Ml Rotor6 X 50 Ml Fixed Angle Rotor15ml Adapterstrip Rotor Microplate Rotor , Double Beam Uv Visible Spectrophotometer Optical Design: Double Beam • Light Source: Xenon Flash Lamp With 3-Years Warranty And At Least 7 Years Life• Detector: Dual Silicon Photodiodes • Wavelength Range: 190 –1100 Nm • Wavelength Accuracy: ±0.5 Nm • Spectral Bandwidth: 2 Nm Or Better • Wavelength Reproducibility: <±0.02 Nm ( 546.1 Nm Mercury Line, Sd Of 10 Measurements ) • Data Interval: 0.1 Nm, 0.2 Nm, 0.5 Nm, 1 Nm, 2 Nm, 5 Nm • Photometric Range: –2A To +3.5A • Photometric Repeatability: ±0.001A At 1A • Photometric Display: -3A To 5.0A • Baseline Flatness: ±0.0010A, 200-800Nm, 1.0Nm Sbw • Noise: =0.00020A At 0A At 260 And 500 Nm =0.00030A At 1A At 260 And 500 Nm =0.00040A At 2A At 260 And 500 Nm • Drift : <0.0005A / H • Baseline Flatness: ±0.002A • Stray Light : < 1.0%T 198 Nm ( Kcl ) , <0.05%T At 220 Nm ( Nai ) , <0.03%T At 340 Nm ( Nano2 ) • Display : 7 Inch Color Touch Screen, Tiltable, High Definition, 800 × 1280 Pixel • Keypad: Touch Screen • Warranty: 3 Years • Included 8-Position Cell Changer As Standard. • Usb Memory Device • A Pair Of Quartz Cuvette With 10 Mm Path Length And 3.5 Ml Volume • Free Of Cost Installation , Training And Demonstration At Site , Horizontal Electrophoresis Unit With Power Pack• The Horizontal Electrophoresis Unit Must Include 10X10cm Tray. • Gel Trays Should Be Uv Transparent. • Lid And Cables Should Be Separate And Must Not Be Attached.• Bromophenol Blue Migration Should Be Approx 4-5Cm / H At 90V.• Run Time Should Be 45-60 Min At 90. • Should Include 1 Mm Thick 2 Combs Of 16 Sample Wells.• Buffer Volume Should Not Be More Than 300Ml.• Tank Of The System Should Be Single Moulded To Ensure Leak Proof Buffer Tank. Even The Parts Should Also Be Single Molded That Are Easy To Repair And Replace.• 16 Sample Combs Should Have 16 ?L Sample Capacity In Each Well.• The Electrodes Should Not Be Attached To The Tank And Should Be Cassette Type Electrodes For Easy Repair And Replacement.• Should Have Pure Platinum Wire And Gold Plated Corrosion Resistant Electrodes.• Should Include Casting Dams For Tape Free Casting Of Gels.• Should Include Loading Guides For Easy Identification Of Wells.• Should Have Color Coded Combs Option And Should Have Options For 0.75Mm, 1Mm, 1.5Mm And 2Mm Combs.• It Should Support Widest Range Of Combs To Run Up To 100 Samples. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .Power Supply:- • The Power Supply Should Have 300V, 400Ma And 60W With 1V / 1Ma Resolution.• The Output Of The Power Supply Should Be Constant Voltage Or Constant Current.• The System Should Have Timer For 1-999 Mins With Alarm.• Should Have 3-Digit Led.• The Power Supply Should Have Provision To Connect Two Gel Chambers. • Should Have Alarm Function.• Should Have Microprocessor Control.• The System Should Have Auto Cut-Off Function.• Safety Features Includes Shrouded Plugs And Sockets, No Load Detection, Overload Detection, Over Voltage, Current & Temperature Protection, And Maximum Power Output Detection. • The Unit Should Have En-61010-1 & Ce Regulatory Conformity. • Operating Conditions Should Be Ambient-40°C, =95% Humidity.• Operating Conditions Should Be 100-240 Vac. • The Power Pack Dimensions Should Not Be More Than 140X191x84mm ( Wxdxh ) .• Weight Of The Power Pack Should Not Be More Than 1 Kg. • The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And• Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of • Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .• Vendor Should Be Submit Authorization Certificate, Having Service Facility At Kerala, Service Centre Address To Be Furnished.• Warranty: 1 Year , Pcr Thermal Cycler • Block Format Should Be 96 Well Gradient Or Veriflex Block • Heating Mode: Peltier Heating.• It Should Be Capable For 0.2Ml Pcr Tubes, 8X0.2 Ml Strips And 96 Well Microplates. • Temperature Range: 4-100 Degree Cel. Heated Lid Up To 110°C• The Ramp Rate Should Be 3.5 Degree Cel / Sec. Or More • Max. Sample Ramp Rate: 2.5°C / Sec Or Above• Pcr Volume Range 10–100 ?L • System Should Need A Color Lcd / Led Touch Screen For Step Based Graphical Programming• 500 Mb Or Above Onboard Memory • Temperature Calibration Should Be Calibrated To Standards Traceable To The National Institute Of Standards And Technology • Instrument Should Have Cloud Based Tools Allow To Securely Store, Access, Share And Manage Data Remotely.• It Should Be Duly Certified For Pcr Process. • It Should Need Provision For Usb, Cloud Via Ethernet And Pc.• Warranty 2 Years , Micro Pippet Set Volume Ranges: 0.2-2 ?L, 2-20 ?L, 20-200 ?L, 100-1000 ?L Flex Tips: 10, 1 × 96; 200, 1 × 96;1000, 1 × 96 Warranty: 5Yearsor More Reagent Reservoir Demo Pack Pippets Stand Fully Autoclavable Volume Gearing Mechanism For Accuracy And Precision. Should Be Extremely Light Should Have Soft Touch Tip Ejector Large Display Prevents Eye Strain Very Light Pipetting Forces For Greater Accuracy With Less Fatigue Fully Autoclavable Vendor Should Be Provided Authorization Certificate For Specific Tender / Quotation
|