Tender For Replacement Of Old Dbs At Apc, Pgimer, Chandigarh.; 1 Supplying and fixing 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 Supplying and fixing 4 way (4 + 12), Double door, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 3 Supplying and fixing 6 way (4 + 18), Double door, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 Supplying and fixing 8 way (4 + 24), Double door, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 5 Supplying and fixing 12 way (8 + 36), Double door, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TP MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)The DB Should be compatible for MCCB as Incomer switch. 7 Supplying and fixing of 8 way (4 + 24), Double door surface/ recess mounting, vertical type, 415 V, TP MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)The DB Should be compatible for MCCB as Incomer switch. 8 Supplying and fixing of 12 way (4 + 36), Double door surface/ recess mounting, vertical type, 415 V, TP MCCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)The DB Should be compatible for MCCB as Incomer switch. 9 Supplying and fixing Single pole 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 10 Supplying and fixing Single pole and neutral 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 11 Supplying and fixing 40A to 63 A Triple pole, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 12 Supplying and fixing 40A to 63 A Triple pole and neutral, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 13 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 14 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 15 Supplying and fixing Cable End Box (Loose Wire Box) suitable For 4 way, Double door TPN MCBDB triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 16 Supplying and fixing Cable End Box (Loose Wire Box) suitable For 8 way, Double door TPN MCBDB triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. 17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 18 Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 50 sq. mm (35mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 19 Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 20 Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm (28mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 21 Providing and fixing of 4 sq. mm copper thimbles for loop earting wire 22 Supplyingof 50 sq.mm, 3.5 core of Aluminum Conductor Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. 23 Supplyingof 10 sq.mm, 4 core of Copper Conductor Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. 24 Supplyingof 16 sq.mm, 4 core of Copper Conductor Balance Stranded Conductor, XLPE Insulated, Cores Laid Up, PVC Innersheathed, Armoured, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments. 25 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required. 26 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) on wall surface as required. 27 Supplying and fixing of STRAIGHT CABLE LUGS/splices of 1.5 - 10 sq.mm and ofHigh Conductivity Annealed Copper(99.9%), Electrolytic tin-plated(minimum 3 micron) suitable as site requirtement including suitable electrical insulation as required. 28 L.TPANEL: SITC of L.T panel made of CRCA sheet of 14/16 SWG, Powder Coated Paint, chemical treatment with 8 tank process Method for degreasing, Derusting and Phosphating Powder coating shall be 60-80 microns, Aluminium Bus bar, FLOOR Mounted/INDOOR TYPE, Transparent Acrylic /PVC sheet/Bakelite sheet should be for shrouding. The dimensions of panel will be as per site requirement. INCOMER FEEDERS : 1&2 250A 4P 36kA MCCB with thermal magnetic O/L & S/C protection - 2 Nos., Rotary Operating Handle - 2 Nos., Spreader Links (Set of 4) - 4 set, U/V release - 2 Nos., Auxiliary contacts - 2 Nos., Auxiliary relay 220V AC - 2 Nos., Key Lock - 2 Nos., 06A SP 10kA MCB - Curve "C" ( For Control) - 8 Nos., 3Ph VAF + PF meter Cl 1 - 2 Nos., 250/5A, 15VA Cl-1.0, Current Transformer-Resin Cast - MET. - 6 Nos., R-Y-B Phase Indicating Lamps220V AC-LED Type (set)-4 Nos., C.T. Shorting Links - 6 Nos., Neutral Link - 2 Nos. Note: Both Incomer Electrically & Mechanically Interlock. OUTGOING FEEDERS : OUTGOING FEEDER 100A 4P 25kA MCCB with thermal magnetic O/L & S/C protection - 04 nos, Spreader Links (Set of 4) - 08 set. Main Bus Bar : 01 No.: 400A FP Aluminium Bus Bars - Electrolytic Grade E-91E grade, AL. Horizontal, Vertical, Input & Output Links of SWG, Bus Bar Supports, Colour Coded PVC Heat Shrinkable Sleeves, Earth Bus across the width of the panel. ENCLOSURE & ACCESSORIES: Indoor type -Non Compartment - 01 No.: Estmd. Size of Panel: H-1000, L-1200, D-300 Approx. MS Cabinet (2/1.6mm - CR-2 D-Grade) with Base Frame Mounting Plates, MS Channels, Partitions & Gland Plates. EPOXY Powder Coated Paint (Min. 60Microns) after Seven Tank Pre-treatment Process, Hardware and Accessories - Nuts, Bolts, Washers - Plain & Spring, Door Hinges (Aluminium Die Cast), Steel Door Locks. Neoprene Rubber Gaskets -"D" Type, Rubber Gromet, Transparent Polycarbonate Sheet for covering live parts + Fly Nut + Handle "I" Lifting Hooks with Plain & Spring Washer and Bolts, Inscription Name Plates, Danger Plates, Legends, Lock / Unlock Sticker, Copper Wires for Feeders Door Eathing with Thimbles. Wiring & Accessories : 01 set PVC Wires, Ferrules Thimbles & Other Wiring Accessories, PVC Channels, Terminal Strips, End Plates, Dressing Materials for Wiring, Buttons, Tie Sticker, Terminal Blocks. Drawing of LT panel should be approved from EIC before fabrication.Total As above: 29 Supplying and drawing 3 X 1.5 sq.mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 30 Supplying and drawing 3 X 4 sq.mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 31 Supplying and fixing of 20 mm of medium class PVC conduit along withaccessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 Supplying and fixing of 25 mm of medium class PVC conduit along withaccessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 33 Providing and fixing of 1.5-4.0 sqmm crimping Pin type, insulated, copper lugs for Proper DB dressing. 34 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 35 Providing and fixing 6/8 way earth bus bar set including mounting component complete in all respect of 50 mm X 5 mm copper strip on surface for connections etc. as required. 36 Providing and fixing 100 A, 25 KA,TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 37 Providing and fixing 200 A, 25 KA,TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 38 Providing and fixing 250 A, 35 KA,TPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 39 Supplying and fixing 63 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Supplying and fixingfour pole, sheet steel, MCB enclosure, on surface/ recess, complete with powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 41 Supplying and fixing3/4 pole, sheet steel, MCCB enclosure, on surface, complete with powder painted including earthing etc. as required. (But without MCCB) 42 Supplying and fixing ofModular PVC box of 3M(nominal size) on surfaceas required. The specifications and quality of PVC Box should be upto entire satisfaction of EIC. 43 Supplying and fixing ofModular PVC box of 6M(nominal size) on surfaceas required. The specifications and quality of PVC Box should be upto entire satisfaction of EIC. 44 Supplying and fixing 3 Module Modular base & cover plate on existing modular metal boxes etc. as required. 45 Supplying and fixing 6 Module Modular base & cover plate on existing modular metal boxes etc. as required. 46 Supplying and fixing 5/6 A modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 47 Supplying and fixing 15/16 A modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 48 Supplying and fixing 3 pin 5/6 A socket outlet switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 49 Supplying and fixing 6 pin 15/16 A socket outlet switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 50 Add GST component @ 6.33% on total amount
|