Stage Rental 12 X 10M - In The 12M X 10M Dimensions With Upper Coverage, Plywood Floor, Properly Painted, 1, 80M Of Ground And 6M Right Foot In The Center, Structured In Aluminum Lead, With Closures On The Sides And Background With Black Screen, Ramp And Access Ladder And Finish On Skirts, Front, Sides And Black Screen Background; With 4, 5M Free Of The Stage Floor To The Scenic Lighting Support Structure, Q-30 Lines To Support Scenic Lighting, Front, Center And Against Light, Capable Of Supporting The Weight Of The Lighting Material, Accompanied By 02 Pa Fly Towers With Opening Of 3, 00 M X 3, 20 M Minimum Right Foot Of 12 M And An Area Of House Mix Combined With The Side Of The Stage Measuring Architecture And Agronomy (With Grounding, Engineer And Technician). The Assembly, Disassembly, Transportation, Accommodation And Food Of The Item Is The Obligation Of The Beneficiary Bidder, Who Must Hire The Assistants Of Services, Porters, Assemblers, Electricians And Other Professionals Necessary For The Execution Of The Object. According To Safety Standards, Setting The Entire Structure Of The Stage In The Ground To Avoid Possible Accidents, As Well As To Provide Art (Technical Responsibility Annotation) With The Fire Department, Ensuring Society That These Technical Activities Are Performed By A Professional Enabled., Stage Rental With A Maximum Of 10 M Front By 8 M Deep, Floor Height To The Floor And A Maximum Of 1, 80 M, With Steel Floor Support Trusses Built On “U” Type Beams And Round Tube And “L” Iron In 1020 Steel; Floor - Wooden Floor, 18 Mm Naval Timelite With A 50X50mm Square Tube Iron Frame; Coverage Structure - Consisting With Steel Tubes In The Diameter Of 2.1/2 ”, 2” And 1.1/4 ”In The 6261 Schedule League; Coverage - Coverage In Canvas Chapter 1100 With Film, With Flame Retardation; Fly Towers - Being 2 Fly Towers Measuring 3.20 Front, 2.5 Background And 8 Meters High Built In Steel Tube With 3 -Ton Tonne And Load Stick. The Assembly, Electricians And Other Professionals Needed For The Execution Of The Object. The Beneficiary Bidder Is In Accordance With The Security Standards, Arrange The Art (Technical Responsibility Note) With The Fire Department, Rental, Installation And Maintenance Of An Electric Generator With A Capacity Of 100 Kva; Three -Phase Silence; Voltage 110V/220V 50 M Of Cable, The Generator Should Operate In A Continuous Regime 12H Day. The Generator Should Include: • 50 Meters Of Antholm Cable For Each Phase And For The Neutral, With A Minimum Gauge Of 95Mm, With Properly Marked Ends And Terminals Compatible With The Equipment, The Cables Should Not Have Amendments Or Patches And Should Be In Good Condition • Intermediate Box For Coupling The Equipment To Be Energized, With Connections And Protective Lid. The Intermediate Caixa Should Have Sockets, Abnt Standard, For Rapid Installation Of Equipment • Containment Basin, In Case Of External Fuel Reservoir • Fire Extinguisher And Other Safety Materials Required By Law. ., Assembly And Disassembly Of Gradyl For Aluminum Events Produced In Aluminum With Measures 2.00 Long By 1.20 High.
|