PROVISION OF DEFICIENT MARRIED ACCOMMODATION AT AF SULUR (PHASE-II); 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part II to XII are prepriced by MES under Ser No. 2 to 13. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 4 Lumpsum price worked out by the contractor for “Internal Electric Supply" as listed in Schedule ‘A’Part–III 5 Lumpsum price worked out by the contractor for “Site clearance and development" as listed in Schedule ‘A’ Part- IV. 6 Lumpsum price worked out by the contractor for "Road/culvert/Footpath" as listed in Schedule ‘A’ Part -V . 7 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 8 Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part – VII. 9 Lumpsum price worked out by the contractor for “External Water supply” as listed in Schedule ‘A’ Part – VIII. 10 Lumpsum price worked out by the contractor for “External ElectricSupply ” as listed in Schedule ‘A’ Part – IX. 11 Lumpsum price worked out by the contractor for “Fire fighting ” as listed in Schedule ‘A’ Part – X. 12 Lumpsum price worked out by the contractor for “LIFT” as listed in Schedule ‘A’ Part – XI. 13 Lumpsum price worked out by the contractor for “Lighting Protection” as listed in Schedule ‘A’ Part – XII. 14 Sch "A" Part - I : BUILDINGS OR WORKSDesign and Construction of Md Accn for Sergeant /Cpl including covered GF stilt parkingin 7 storey (Ground+6 storey) with using3D monolithic modular Technology / precast construction in RCC of grade as per structural drawings with Cast in Situ foundation withATT, PU based WPT, RCC Water Tank on terrace, earthquake resistance as per latest IS, UPVC window and Green building norms with GRIHA three star rating etc complete all as specified and as shown on drawings. (Note: The quoted rate against is deemed to included for the provisions contained in Sch "A" Notes. Refer Sch "A" Notes complete before quoting these items. Structural design and structural drawings for super structure and foundations for the building/structure shall be prepared to comply with the provisions for design and analysis of RCC structures as per latest editions relevant IS Codes). 15 Sch "A" Part - XIII : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYS&F 15 mm bore kitchen sink tap, brass chromium plated dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed. 16 S&F 15 mm bore washing machine tap, brass chromium plated complete all as specified and as directed. 17 INTERNAL ELECTRIC SUPPLY Supply and Fix Surface mounted square panel light fitting 1ftx1ftof 18W, 220Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers suitable for roof ceiling in and including connecting up with three core flexible copper conductor cable of suitable size and connected accessories etc. complete in allas specified and as directed . 18 S&F TPN vertical Distribution board 8 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with minimum 200 Amps rating bus bar etc. complete in all respects all as specified and as directed . 19 S&F TPN vertical Distribution board 4 Way, Protection class IP-43 Double door suitable for incomer MCCB suitable upto 160 Amps and outgoing MCB TPN/SP MCB with min 200 Amps rating bus bar etc. complete in all respects all as specified and as directed . 20 Supply and fix MCCB 4 Pole, 415 Volts, Adjustable Thermal & Fixed magnetic type 100Amps with breaking capacity 16 KA etc. complete in all respects all as specified and as directed. 21 Supply and fix MCCB 4 Pole, 415 Volts, Adjustable Thermal & Fixed magnetic type 63 Amps with breaking capacity 16 KA etc. complete in all respects all as specified and as directed . 22 S & F Sub main wiring complete with Four runs of 4.0 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with two run of4.0sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallicPVC conduit and conduit accessories(Concealed in walls / roofs) etc. complete in all respects all as specified and as directed. 23 S & F Sub main wiring complete with Four runs of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable with two run of2.5sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallicPVC conduit and conduit accessories(Concealed in walls / roofs) etc. complete in all respects all as specified and as directed. 24 S & F Sub main wiring complete with Four runs of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with two run of 2.5sqmm single core PVC insulated FRLS cable 1100 volts grade, multistrandedcopper conductor cable as earth continuity conductor, drawn through and including rigid nonmetallic PVC conduit and conduit accessories (Concealed in walls / roofs) etc. complete in all respects all as specified and as directed. 25 Supply and fix Modular TV Socket, one module etc complete in all respect all as specified and as directed . 26 M&L for TV Wiring with unarmored co-axial cable, RG-11 in and including concealedwith PVC Conduit 25 mm diaetc complete in all respect all as specified and as directed. 27 EXTERNAL WATER SUPPLYCutting cast iron and reducing to required length before laying pipes in position for insertion of new tees, branches of different sizes as per site requirement for 150 mm bore complete all as directed. 28 Construction of valve chamber with inner clear dimension 600 x 600 x 900mm suitable for 80mm sluice Valves with PCC (1:4:8) 150mm thick type D2 for foundation, Brick masonry 230mm wall in CM (1:4), PCC (1:2:4) 75mm type B1 for coping, rendering in CM (1:4) 15mm thick including provision of 3mm thick MS sheet cover and 25 x 25 x 3mm angle frame embedded in coping with two coats of synthetic enamel paint over a coat of redoxide primer with locking arrangements including necessary earth work complete all as specified and as directed . 29 EXTERNAL ELECTRIC SUPPLYTaking down existing transformer of capacity 200 KVA safely from he existing platform with the help of hydra by disconnecting the existing LT cables, LT cables and earthing after taking proper shutdown from the Engineer in charge or his representative . Shifting of the same to the new proposed location of approx 3Km with the help of hydra and suitable load carrying vehicle and placing the same on a new platform with the help of hydra. Making the connections of HT cable, LT cable and earthing strip complete including testing and commissioning of transformer complete all as specified and as directed. 30 Material and labour for brick masonry transformer platform of size 1.5m x 1.5m with height 1.2m above GL, cement concrete in foundation of PCC 1:4:8 type D2 using 40mm graded stone aggregate, 1:3:6 PCC block masonry in cement mortar 1:4, moorum filling sand consolidating inside the brick work, sub base concrete with PCC 1:3:6 and 100mm thick top PCC 1:2:4 type B2 using 40 mm grade stone aggregate and 15mm thick (1:4)cement plaster on side walls including two coats of white wash complete all as specified and as directed. 31 Takingdown existing diesel generating set of capacity 30KVA from the existing platform with the help of hydra by disconnecting the existing LT cables and earthing after taking proper shutdown from the department. Shifting of the same to the new location of approx 3KM with the help of hydra and suitable load carrying vehicle and placing the same on a new platform with the help of hydra. Making the connections of LT cable and earthing strip complete including testing and commissioning of DG set complete all as specified and as directed. 32 Returning and filling in two parts (i) using riddled soil obtain from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note:- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255 1983 and refilling in trenches as in cable cushioning. In case of sufficient soil is not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from outside MD land. 33 Supply Install, and commissioning LT feeder pillarOutdoor typeIP-65 made out of 3.15 mm thick MS sheet and angle Iron frame work, cubicle type with copper bus bars and with suitable mounting plate, frame and canopy, confirms to IEC61439-2 with following accessories suitable for incoming/outgoing arrangements:- (a)MCCB with extended rotary handle and spreader link 250 A 35kA4 pole - 01 No(b)MCCB with rotary handle and spreader link 160 AMP 25kA4 pole- 01 No(c) MCCB with rotary handle and spreader link 40 AMP 25kA4 pole- 01 No (e) Digital panel meter for volt Amp/Volt/KWH&PF -01 No(f) LED indicating lamp set- 01 Set of three (g)Timer Switch 20 Amps (h) Channel size 70x40x6MM suitable for LT Panel Load (j) PCC foundation as per OEM drg. 34 M & L for GI bracket suitable for street light fittings bend to required shape made up of dia GI tubing 40mm dia medium grade of length 1.50 Mtr including clamps nuts bolts washers complete all as specified and as directed. 35 Supply and fix Synchronising electronic timer unit operated on AC 230 Volts, 24 hrs clock time for controlling street lights/ flood lights etc all as directed. (Make :-Cat Part No : 4126 41 of Legrand or equivalent in makes specified in PS) 36 Supply and fix Powercontactors 63 Amps, 4 pole,415V etc all as directed. ( Make : Cat No 4125 57 of Legrand or equivalent in makes specified in PS) 37 M & L for sheet metal enclosure dust, weather and vermin proof rain guarded cable entry and exist arrangement front side hinged door with closing arrangement SMC junction box of size 300 x 200 x 105mm complete all as specified and as directed. 38 FIRE FIGHTINGS&F Clean Agent based stand alone automated Fire Suppression system HCFC123-10 KG complete all as specified and as directed. (Make- Ceasefire/Model No.CF000771 or equivalent as approved by GE) 39 Supply, laying, testing and commissioning Terace Pumping sets, centrifugal, electric driven, supply and Install complete capacity of 900 LPM and 3.5 KG/CM2inclusive of starter and suitablePCC foundation complete all as specified and as directed. 40 Supply and install testing and commissioning of yard hydrant consisting of the following components complete all as specified and as directed:-(a) 63 mm dia instantaneous pattern oblique hydrant with chain cap(b) 63 mm dia size controlled peculation hose of 2 Nos 15 mtr with gun metal female instaneous coupling as necessary.(c ) Sheet steel fabricated hose cabinet of suitable size power coat painted to house the above accessories.(d) one set of branch pipe made of gun metal. 41 Supply and laying ofPVC insulated PVC sheathed wire armoured with multi stranded copper conductor of size 4 Sqmm 4 core 1100 volts grade complete all as specified and as directed. 42 Supplyand fix Dry Chemical Powder (ABC) 4 KG fire extinguisher complete all as specified. 43 Supplyand fix Light weight squeeze grip typeCO2 Type Extinguisher (IS: 15683) - 3 Kg capacity complete all as specified. 44 Supplyand fixFire Extinguisher water (Stored pressure type) 9 Ltr capacity complete all as specified. 45 Supply and fix Dry chemical powder extinguisher 9 kg complete all as specified. 46 Supply and fix Light weight squeeze grip typeCO2 Type Extinguisher (IS: 15683) - 4.5 Kg capacity complete all as specified. 47 Supply and fix Mechanical foam type Fire Extinguisher (IS: 15683) - 9 Ltrs capacity complete all as specified. 48 Supplyand fixFire Buckets-02 Nos (IS: 2546) including fire point made of PCC bed, MS pipe of 40mm dia, CGI sheet etc. complete as specified and as directed. 49 LIFTSupply and fix 4 Pole MCCB63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and as directed. 50 LIGHTINING PROTECTIONSupply and fix epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc complete all as specified and as directed. 51 AVIATON OBSTRUCTION LIGHTSupply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure complete all as specified and as directed. (Make Bajaj Cat No. BGAV 302 LED or equivalent as given in PS and as approved by GE) 52 S&F DP MCB 6 A with enclosure complete all as specified and as directed. 53 Supply and fix time switches 250 V single Phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and as directed. 54 SMART PREPAID METER Design, installation, testing, commissioning, integrate and maintain the Advanced metering infrastructure (AMI) Comprising of following:-(a) Supply, installation, testing, commissioning of smart meter AC single phase, two wire, 240 volts, 50Hz, 10 to 60 amps of different makes (not more than 33% of a particular make to ensure interchangeability at a later date as per BIS 16444 with communication technology including GPRS / RF / Hybrid (GPRS+RF) any other advanced technology as per CEA/TRAI regulations).(b) Supply / planning / setup/ tuning of RF communication infrastructure including Network Management (NMS) & Head End system (HES) for the project area. AMI software and associated equipment should be capable of handling atleast 10000 number of meters of different makes as per BIS 16444 with 25% expansion without any additional infrastructure and cost implication to MES.(c) Supply and setup of Meter Data Management (MDM) System.(d) Integrationof different devices of different makes/equipment/software covered in scope of this project with each other as per functional requirement, including water charges, furniture and license fee. 55 (e) Integration/ interface of the AMI system with application system like metering/billing/collection, interface has to be provided in the proposed solution to upload and process meter data from these systems.(f) Server for housing and management of supplied software application with Standby server (OR) hosting the system to government community cloud in place of server for hosting and management of supplied software application with standby server.(g) Planning, deployment & tuning of communication system including cellular network (if required) to meet the performance requirements.(h) Business intelligence, Analytics and Reporting.(j) Taking down & Return of dismantled materials to MES Store.(k) Training and knowledge transfer.(l) All expenditure including periodic charges of telecom operator from installation till completion. 56 Schedule "A" Part - XIV (Comprehensive operation including required manning of AMI system)Comprehensive operation and maintenance of AMI system including project implementation & management, all expenditure including periodic charges of telecom operator, smart meter billing and maintenance, for a period of 2 years post completion of work i.e Defects Liability Period.
|