Tender For providing Of Certaind E/M Work Services Pertain To Revenue And Minor Work Under Ge Af Tech Area Agra- 1 INTERNAL ELECTRIFICATION Taking down carefully Aluminium/copper point wiring battentype/casing capping/concealed type any description (Light/ Fan/Socket or power)complete incl fitting, fixture such as switches, sockets, ceiling rose, brackets, holders, bulk head fitting etc and making good disturbed surface of wall/ceiling etc., all as specified and directed. 2 Taking down main switch/MCB DB/AC enclosure/Three phase enclosure by disconnecting the electric supply all as directed at site. 3 Taking down old XLPE cable of any size up to 25 Sqmm from wall/ceiling/truss/duct by disconnecting the electrical connection and descrewing the saddle clips/clamps and keeping aside to reuse the same after ceiling work complete all as specified and directed. 4 M&L for point wiringof complete with stranded copper conductor 1.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including concealed PVC conduit ISI marked medium grade not less than 20mm dia with all accessories such as TEE, bend,elbow,reducers,sockets and junction boxes etc, concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint and bituminous coat of external portion to prevent the rust with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 1.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, all cable ends will be terminated with suiable brass thimbles to prevent the heating of termination point completefor One light/fan/exhaust fan point controlled by one way 5 Amp switch.with all accessories all as specified and directed: - 5 All as per Ser Item No 4 above but for one 3 pin/5 pin socket out let 5 Amp on independent board with indipendent circuit from DB box. 6 All as per Ser Item No 4 above but for one 3 pin/5 pin socket out let 5 Amp same board 7 All as per srl item No. 4 above but for 3/5 pin socket outlet for 15 Amps on independent board with indipendent circuit drawn from DB box with 2.5 sqmm PVC insulated, unsheathed single core multistranded copper conductor cable 1100 volts grade including 2.50 sqmm PVC insulated unsheathed solid copper conductor cable as earth continuity conductor complete all as specified & directed. 8 S&Fswitch piano, flush type 5 Amp single pole one way. 9 S&/F of switch piano, flush type 15 Amp . 10 S&Fof socket out let, flush type 5 pin 5 Amp. 11 S&/F of socket outlet multi purpose 3 pin 15 Amp and 3 pin 5 Amp, flush type. 12 S&Fof ceiling rose surface bakelite ISI Marked three terminal. 13 Supply and Fixlamp holder PVC/polycarbonate angular/batten type with back plate fancy type with three terminals isolated body all as specified. 14 S&F stepped type Electronic fan regulator flush mounted socket type complete all as specified and directed. 15 S&Fheavy duty exhaust fan steel body AC single phase 230 volts ,50 Hz of size 300mm sweep , 900 RPM with blades, frame and louvers fixing with cutting the existing wall of adequate size in round shape , making good the disturbed surface with cement mortor and grouting the louvers and nut bolts of exhaust fan complete all as spacified and directed. 16 Supply and fix LED tube light fitting 1x20 Watt , AC decorative box type with driver , holder including LED tube light connecting up with three core flexible copper conductor of suitable size from ceiling rose to fitting and complete all as specified and directed. 17 Supply and fixLED luminaire 600mmX600mm, 36 Watt, AC 230 Vrecessed type with high effeciency PMMA diffuser soft glare free light complete with driver, holders&LED lamp suitable for roof, ceiling including connecting up with driver threecore flexible copper conductor cable of suitable size complete all as specified and directed. 18 Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, BEE, 5 star rated motor complete all as specified and directed. 19 S&F in repair ofMCB DB of sheet metal enclosure double door type, single pole and neutral 8 way with 200 Amp rated bus bar 240V andgrouted in walls with PCC 1:2:4 type B1 using 20mm graded stone aggregate etc complete all as specified and directed. 20 S&F in repair of MCB DB of sheet metal enclosure double door type, single pole and neutral 4 way with 200 Amp rated bus bar 240V andgrouted in walls with PCC 1:2:4 type B1 using 20mm graded stone aggregate etc complete all as specified and directed. 21 S & fix in repair ofMCB SP 6 to 32 Amps, 240V "C" Series 10 KA etc complete all as specified and directed. 22 S & fix in renewal of MCB DP 40 to 63 Amp 240 Volts "C" series 10 KAetc complete all as specified and directed. 23 Supply and fix in renewal of LED street light 45 WattIP 66, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device including GI bracket made by 40mm GI pipe light grade bent to shape of length 1.5 mtrs and with GI clamps ,nut bolts etc grouting on walletc complete all as specified and directed. 24 S&F in replacement of sub main wiring drawing in and including concealed PVCconduit not less than 25mm dia medium grade with 2 run of single core PVC insulated unsheathed cable with stranded copper conductorof 06 Sqmm nominal area and PVC insulated unsheathed cable with stranded copper conductor of 06 Sqmm size single core as earth continuity wire and connected to earth dolly with proper crimping of thimbles bottle type and all as specified and directed. 25 S&F in replacement of sub main wiring drawing in and including concealed PVCconduit not less than 32mm dia medium grade with 4 Runs of PVC insulated unsheathed cable with stranded copper conductor cable of 10 Sqmm nominal area and single core PVC insulated unsheathed cable with stranded copper conductor of 10 Sqmm sizeas earth continuity wire and connected to earth dolly with proper crimping of thimbles bottle type and all as specified and directed. 26 S&F in renewal ofVTPN DB,4 way Vertical type,440V,3 phase with rated busbar 250 Amps, double door type , IP-54 protection and mechanical strength IK 09 ,isolated neutral busbar suitable for accomodate MCCB 3/4 pole 415 volts rating upto 250 Amp as a incomer and MCBs as out going ,grouted in walls by using PCC 1:2:4 type B1 etc complete all as specified and directed. 27 S & fix in renewal of MCCB DPX 160 thermal magnetic of 63 Amps 3 pole 16 KA, 415 Volts 50 Hz complete including connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles all as specified and directed. 28 Supply and Laying in repair XLPE PVC sheathednsulated LTUG cable , beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 25 Sqmm 4 core laid intrenches or fixed on wall/floor/poles etc complete all as specified and directed. 29 Excavation in trenchesn. exc 1.5 m wide and n. exc. 1.5 m in depth for laying cables and getting outin soft/hard soil etc complete all as specified and directed. 30 Returning filling in including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in hard/dense soil after cable are laid and tested etc complete all as specified and directed. 31 Removing excavated surplus soil to a distance n. exc. 50m and deposited where directed at a level n. exc.1.5m above the starting point etc complete all as specified and directed. 32 M&L for sand filing with clean dry fine sandincluding gently punning around cables in trenches for cable protection complete all specified and directed. Note : punned thickness shall be measused and paid. 33 Supply & Laying sub class "B" briks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed. 34 M&L 50 mm dia GI tubing light grade with all fittings such as tee, bend,elbow,reducer, socket etc laid in trenches or fixed on pole/wall for protection ofLT UG cable etc complete all as specified and directed. 35 M&L for earthingwith galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron wire of size 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl excavation and earth work in any type of soil and disposal of surplus soil for a distance nexc 50m including 40 mm GI tubing light grade and necessary fitting for protection of copper strip incl laying of charcoal dust and common salt in atternate layer including earthing pit constructed in PCC (1:3:6) type C-1 using 20mm graded stone aggregatewith 40x40x6mm MS angle iron frame, RCC cover 40mm thick in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle made out of MS round on 12mm dia, plastering 15mm thick in CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia medium grade GI pipe for watering and GI wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test incl testing etc complete all as specified and directed including demolition of old earthing. 36 AIR CONDITIONING Supply and install testing and commissioning hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality minimum 5 star rating inverter type and EER 3.2.of capacity 2.0 TR and connected electrically indoor and outdoor with 2.5 Sqmm 4 core copper conductor multi stranded and all connected accessories ie wall mounting stand/bracket with MS nut bolts and all as specified and directed. 37 S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 volt all as directed. 38 Supply and fix the Refrigerant pipe of copper of size 1/4" suitable for AC s of capacity 2.0 TR including cutting and jointing and soldering etc alongwith insulation materials and condensing water PVC drainage pipe and all as specified and directed. 39 Supply and fix the Refrigerant pipe of copper of size 1/2" suitable for AC s of capacity 2.0 TR including cutting and jointing annd soldering etc alongwith insulation materials and all as specified and directed. 40 STAND BY POWER SUPPLY Supply and Fixing, Commissioning and testing the onlineUPS with isolation transformer for 30 Min back up three phase AC input 300 to 450V and output 415V (335 to 475) 50 Hz +6% , Out put 3 phase 415 Volts AC + 1% and 50Hz+ 0.1% capacity 7.5KVA with adequate No of batteries and stand for placing the batteries of 20 Nos 12Volts 26 AH along with connecting Copper Leads/cable to inter connect the batteries and UPS to Battery bank and all as specified and directed. 41 Supply and Fixing the MCCB 4pole 415 volts 63 to 100 Amp 50Hz, thermal adjustable magnetic type with rupturing capacity 25 KA enclosed in sheet steel enclosure of adequate size and having suitable incoming and outgoing cable entries and all as specified and directed. 42 M&L for point wiring in renewal of complete with stranded copper conductor 2.5 Sqmm size (Nominal area) PVC insulated unsheathed cable FRLS in and including concealed PVC conduit ISI marked medium grade not less than 20mm dia with all accessories such as TEE, bend,elbow,reducers,sockets and junction boxes etc, concealed sunk in pressed steel terminal boxes of reqd size of thickness 1.6 mm factory made and painted with stove enameled black paint and bituminous coat of external portion to prevent the rust with top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washer including 2.5 sqmm stranded copper conductor PVC insulated cable of green colour as earth continuity connected to common earth dolly and all sunk/terminal boxes and each fitting/fixture, all cable ends will be terminated with suiable brass thimbles to prevent the heating of termination point complete for One 15/16 Amp socket outlet controlled by one 15/16 Amp switch on indipendent board. 43 Supply and fix the cable tray to run the electric /power/AF Net cables of 10 Nos and the cable tray size is not less than 40x10Cm (widthxBearth) of made by GI sheet of thickness not les than 2mm supported with MS angle frame fabricated by using MS angle of size 40x40x6 mm, angle iron will be supported at every meter length to layout on wall with bracing and grouted in PCC 1:2:4 type B1 in wall and all as specified and directed. 44 Air ConditioningSupply and install testing and commissioning hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality minimum 5 star rating inverter type and EER 3.2.of capacity 1.5.0 TR and connected electrically indoor and outdoor with 2.5 Sqmm 4 core copper conductor multi stranded and all connected accessories ie wall mounting stand/bracket withMS nut & bolts etc complete all as specified and directed. 45 M&L for chemical earthing complete with Copper plate electrode of size 900mmx600mmx5 mm thick buried directly in earth pit not less than 4.7 meter below normal ground level and complete size of pit 1.6 meter x 0.61 meter x 5.10 meter, earth plate connected to copper strip 32x6mm by means of copper/ brass nut, bolts earth strip protected with 40 mm bore light grade GI pipe from electrode and upto and including the earth test point of gun metal , 20mm bore watering pipe, medium grade GI pipe including PGI funnel wiremesh providing alternate layer of 10 cm each charcoal salt and magnesium sulphate layer upto 1.2 meter and 2 Kg copper sulphate to be added around including excavation, in any type of soil returning in filling, removal of surplus soil to a distance not exceeding 50m, PCC pit in PCC 1:2:4 type B1 (using 20mm graded stone aggregate), as in earth pit with 40 x 40 x 6 mm MS Angle iron frame and pit cover of made by dholpur stone 40x40cm size and 40mm thick with well dressed and having of handle of made by 12mm MS Rod for lifting of pit cover,15mm thick plastering with CM (1:6) internally and upto 150mm below ground level externally, etccomplete all as specified and shown on electrical plate No 3 of SSR Part-I (2009) and connected to earth test incl testing. 46 S&F Copper strip of size 32X6 mm earth continuity conductor or main earthing lead fixed to wall on DMC type insulatorsor recess or chases or buried in ground or drawn in conduit/pipe etc. complete all as specified and directed. 47 Material and labour for breaking /demolishing the existing tarmac of thickness 45Cm of adequate size for chemical Earthing and making good the disturbed area by using PCC of 1:3:6 C-1 using 20mm graded aggregate and all as specified and directed. 48 M&L for MS sheet of size 40 x 20cm & thickness of 2mm shape of square/round/triangle as per sample including Angle Iron 25x25x3mm (90 cm long), framed work with shape of "T" etc, necessary welding, earthworks, etc including two coats of synthetic enamel paint over a coat of red oxide primer and marking the word "TESTED ON -------, RESULT -------------" with different colour of synthetic enamel paint with suitable size of letters and allarrangements including grouting with PCC (1:3:6) type C-1 (Using 20 mm graded stone aggregates) of size 150x150x150mm complete all as specified and directed . 49 Supply and Laying XLPE PVC insulated and sheathedLTUG cable beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 10 Sqmm 2 core laid intrenches or fixed on wall/floor/poles etc complete all as specified and directed. 50 Supply and LayingGI Tubing of lights grade of 40 mm dia with all fittings and fixed complete to wall and ceiling or laid in floors/road/PCC floor/hard standings complete al as specified and directed 51 Supply and fix in replacementloop-in/loop-out box of outer size 155x210x92mm made out of FRP body (hot moulded type) with IP-63 protection and locking with screws alongwith 5/6 Amp rating MCB SP-01 No, up to 50 Amp rated 2 pole connector suitable to insert the cable size 25 Sqmm-01 No,with neutral linkand din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on PCC/Brick work pillar including cable glands, aluminum lugs/thimbles for incoming and out going cales andall as specified and directed. 52 Supply and fix the LED flood light fitting of IP-65 protection and 230 volts, 50 Hz of capacity 250 Watt connecting with three core flexible copper conductor of 1.5 Sqmm nominal area from light fitting to connector/junction box and all as specified and directed. 53 Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole as a foundationor pillar to errect flood lights below normal ground level 15 Cm and above ground level 75Cm including excavation in any type of soil etc completeall as specified and directed. 54 Supply and Laying XLPE PVC insulated and sheathed LTUG cablebeddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 16 Sqmm 4 core laid intrenches or fixed on wall/floor/poles with GI saddle clips of two nos for every one meter complete all as specified and directed. 55 Supply and fix in renewalthree phase industrial socket 3P+N+E with MCB TPN 63 Amps capacity with sheet steel enclosure mounted on wall with all fixing arrangements and all as specified and directed 56 Supply and Fixing MCB TPN 415 Volts , 50HZ 63 Amp rating With rupturing capacity 10KA and fixing on existing LT panel board with minor modifications and all as specified and directed. 57 Supply and layingincluding taking down old u/s XLPE PVC insulated and sheathed LTUG cablebeddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor 95 Sqmm 3.5 core laid intrenches or fixed on wall/floor/poles etc complete all as specified and directed. 58 S & fixMCCB 4pole 415 volts of current rating 320-400 Amp 50 HZthermal magnetic adjustable type of 70-100% of rupturing capacity36 KA,complete including sheet steel enclosure having incoming, outgoing cables inlet.outlet holes to connecting all incoming and outgoing connection by means of suitable size of lugs/thimbles and proper cable glands of made by brassall as specified and directed 59 Supply, install, testing and commissioning of Servo controlled voltage stabilizer of Capacity 100 KVA ( Confirming to BIS 9815:Part 1 :1994) Three phase,50 Hz, Naturally Oil cooled , indoor , unbalanced type, copper wound, metallic body duly powder coated with lifting Hooks four nos , digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level complete all as specified and directed and having following specification:-(a) Input voltage 300V-480V. (b)Output voltage stabilized at 415V +- 1%. (c) Rated frequency 50 Hz. (d) No distortion in wave form. (e) Response time not to exceed 20 mile seconds. (f)Sensitivity (+/-)1%. (g) Rate of correction 8 Volt/second for single phase and 13 volts per seconds for phase to phase.(h) Efficiency more than 95%. (j) Type of load : three phase, unbalanced type. (k) Digital display with multi-functional meter.Protections:-(1) Over load/Short Circuit protections on input side by MCCB160 Amp 4 pole 25 KVA(2) High/Low voltage cut off(3) By pass arrangement in case of emergency by on load changeover switch 160 amp 4 pole(4) Single phase sequence change protection 60 Supply and fix the On-load change over switch Front handle operated of 4 pole 415 volts with sheet steel enclosure of capacity 315/320 Amp and all as specified and directed. 61 M&L for earthing complete with galvanised steel plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip of size 32x6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steelconnected to earthing test point all as specified incl excavation and earth work in any type of soil and disposal of surplus soil to a distance nexc 50m including 40 mm GI tubing light grade and necessary fitting for protection of copper strip incl laying of charcoal, dust and common salt in atternate layers including earthing pit constructed in PCC (1:3:6) type C-1 using 20mm graded stone aggregate earth pit with 40x40x6mm MS angle iron frame, RCC cover 40mm thick in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate reinforced with 6 mm dia round bar @ 75mm C/C both ways with MS handle made out of MS 12mm dia, plastering 15mm thick CM (1:6) internally and upto 150mm below ground level externally, PGI funnel with 20mm dia medium grade GI pipe for watering and wire mesh complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test incl testing 62 B/R Portion (For CUAS Hard Kill)M&L MS deformed bars 10mm dia & overcut to length bent to shape required including cranking bending spirally for hooping columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. 63 Use and waste offormworkto sides of pillars,posts, struts, piers, columns,stanchions and blocks with fair finishedpolygon surface etc complete all as specified and directed 64 M&L forpreparation of new concrete wall surfaces and applying two coats of exterior emulsion paint our a one coat of primerin normalas per manufacturers instructions etc complete all as specified and directed by Engr-in-charge. 65 M&L for aluminium Partition wall by using aluminium anodisedsection as in frame size 63.5 X 38.1 x 1.0mm thick includingglazing with 5mm thick Glasspaneling ( Size of paneln.exc 1.5 Sqm each ) and all necessary fittings with and including necessary accessories complete all as specified and as directed 66 M&L forPowder coated aluminiumdoor shutters by using aluminium anodised section weighing 0.55 kg/m including 3mm thick sheetglass, necessary joining cleats,glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified and directed. 67 M&L for MS framed work such as ladder, grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete as specified & directed. 68 M&L for mild steel rag or lewis bolts,screwed one end,with hexagonal or square nuts and washers,the other end enlarged ang jagged or lewised , nexc 15 cm long and 25mm in dia etc complete as specified & directed. 69 M&L for preparation for steel surfaces and applying two coats of synthetic enamel paint over a one coat of red oxide incl preparation of surfaces complete as specified & directed. 70 M&L for Providing cement concrete type B 1, 1:2:4 (using 20mm graded aggregate) as in copings,grouting apex stones, bed,roof surfaces etc including weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed.
|