Stage Contract For Construction Of Passageway Queue Manager And Other Miscellaneous Items Required Within The Territorial Jurisdiction Of Rnb Division Bemina In View Of Forthcoming Lok Sabha Elections 2024- Supply And Fixing In Position Kd Wood Joistsfor Passageway / Queue Manager Including Cost Of Cutting, Fixing In Position With Nails And Fixtures And Cost Of Dismantling On Culmination And Carriage To Divisional Store Or To A Location Designated By Engineer In Charge All Complete 2 Poplar Wood 3 Supplying And Fixing In Position 18Mm Thick Plyboard Of Approved Brand And Manufacture Including Cutting Wherever Required And Fixing To Joists Using Nails Including The Cost Of Nails And Fixtures But Excluding The Cost Of Joists And Including The Cost Of Dismantling And Stacking The Ply Boards At The Venue And Carriage To Divisional Store Or To A Location Designated By Engineer In Charge All Complete 4 Erecting Waterproof And Decorative Shamyanas / Canopies Of Required Area With Including Dismantling After The Culmination Including Cost And Carriage Of All Materials Complete. ( On Rental Basis ) 5 Supplying And Fixing In Position 12Mm Thick Plyboard Of Approved Brand And Manufacture Including Cutting Wherever Required And Fixing To Joists Using Nails Including The Cost Of Nails And Fixtures But Excluding The Cost Of Joists And Including The Cost Of Dismantling And Stacking The Ply Boards At The Venue And Carriage To Divisional Store Or To A Location Designated By Engineer In Charge All Complete 6 Supplying And Laying Rbm / Khak Bajri / Gsb In Layers Not Exceeding 225Mm Including Consolidation With Prr Of 8 To 10 Tonne Capacity All Complete. 7 Supply And Stacking At Site Stone Aggregate Of Size Range 63 To 45Mm With Stone Screenings 13.20Mm Nominal Size And Stone Dust Including Layng Water Bound Macadam To Specifications And Consolidation With Prr Of 8 To 10 Tonne Capacity Complete. 8 Providing, Laying, Spreading And Compacting Graded Stone Aggregate To Wet Mix Macadam ( Wmm ) Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant, Carriage Of Mixed Material By Tipper To Site, For All Leads & Lifts, Laying In Uniform Layers With Mechanical Paver Finisher In Sub- Base / Base Course On Well Prepared Surface And Compacting With Vibratory Roller Of 8 To 10 Tonne Capacity To Achieve The Desired Density, Complete As Per Specifications And Directions Of Engineer-In-Charge 9 Supplying And Spreading Silt Free Granular Coarse Sand / Stone Dust Over Wet And Muddy Areas Including Dressing Of Areas And Cost Of Labour For Spreading And Carriage And Cost Of All Materials Involved. 10 Earth Filling ( Free From Pebbles, Clods, Vegetations And Other Foreign Materials ) Carrying By Mt Laying In Layers Incl. Dressing Watering And Consolidating With Power Road Roller Incl. Cost & Carriage Of All Materials, Leads, Lifts And Carriages From Approved Source Upto Site Of Work Complete ( Including Royality ) 11 Providing And Fixing Precoated Galvanised Iron Sheets 0.40Mm Thick Of Approved Brand And Manufacture With Texture, Shade And Colour As Approved By The Engineer In Charge Including Cost Of Fixing The Sheets To Wooden Battens Including Cost Of All Fixtures And Carriages Complete. 12 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete 10.2.2 Welded 13 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. 13.70.1 Two Or More Coats On New Work 14 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade, One Or More Coats On Old Work. 15 Wall Painting With Plastic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade, One Or More Coats On Old Work. 16 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.7 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 17 Cement Concrete Flooring 1:2:4 ( 1Cement: 2 Coarse Sand: 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry And Curing Complete, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 11.3.2 40Mm Thick With 20 Mm Nominal Size Stone Aggregate 18 Preparation Of Subgrade By Excavating Earth To An Average Of 22.5 Cm Depth, Dressing To Camber And Consolidation With Road Roller Of 8-12 Tonne Capacity Including Making Good The Undulation Etc. And Disposal Of Surplus Earth Upto 50 Meters 19 Consolidation Of Subgrade With Power Road Roller Of 8 To 12 Tonne Capacity Including Making Good The Undulations Etc. With Earth Or Quarry Spoils Etc. And Rerolling The Subgrade. 20 Engagement Of Masons, Electrician, Welder, Carpenter, Plumber And Helpers Along With Equipment For Various Works 21 Carpentar 22 Electrician 23 Welder 24 Plumber 25 Mason 26 Labour / Helper 27 Hire And Running Charges ( The Hire Charges Of Machinery On Per Day Basis Are For Single Shift Of Eight Working Hours. 28 Hydraulic Excavator 29 Tipper 30 Dg Set Including Cost Of Fuel, Operation And Manning With All Carriage To Make It Functional 31 1 Kv 32 2.8 Kv 33 5 Kv 34 Tractor 35 H&P Items 36 Kehwa Zaffrani With Almond Slices 37 Sheermal 38 Namkeen Tea Special 39 Bagirkhani 40 Table ( 3'' X 6'' ) 41 Table ( 3'' X 4'' ) 42 Plastic Chair 43 Vip Chair With White Loose Cover 44 Carpet ( 12'' X 12'' ) 45 Terpoline Polythene ( 12'' X 15'' ) 46 Excel Matting Carpet Of Standard Quality 47 Plastic Bucket 25 Litres With Jug 48 Fire Extinguisher Of 09 Litres Foam 49 Finishing Walls With Water Proofing Cement Paint Of Required Shade:13.117.1 Old Work ( One Or More Coats Applied @ 2.20 Kg / 10Sqm ) Over Priming Coat Of Primer Applied @ 0.80 Liters / 10Sqm Complete Including Cost Of Priming Coat. 50 Providing And Fixing Corrugated G. S. Sheets 0.50Mm Thick Of Approved Brand And Manufactureincluding Cost Of Fixing The Sheets To Wooden Battens With Required Nails Or Hooks Including Cost Of All Fixtures And Carriages Completeand Cutting To Size And Shape Wherever Required. 51 Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc Including Priming Coat With Approved Steel Primer All Complete. 9.48.2 Fixed To Openings / Wooden Frames With Rawl Plugs Screws Etc. 52 Felling Trees Of The Girth ( Measured At A Height Of 1 M Above Ground Level ) Including Cutting Of Trunk And Branches, Removing The Roots And Stacking Of Serviceable Material And Disposal Of Unserviceable Material. 53 2.27.1 Beyond 30 Cm Girth Upto And Including 60 Cm Girth. 54 2.27.2 Beyond 60 Cm Girth Upto And Including 120 Cm Girth. 55 2.27.3 Beyond 120 Cm Girth Upto And Including 240 Cm Girth. 56 2.27.4 Above 240 Cm Girth 57 Pruning Of Poplar Trees By Way Of Trimming Of Protruding Branches Using Chainsaw, Shears, Axes And Ropes Including Chopping Of Trimmered Branches And Stacking At The Designated Location Including Its Clearance From Site By Mechanical Transport So That Trafiic Will Ply Smoothly And Disposal Of The Serviceable / Unserviceable Material With All Leads, Lifts, Carriage Complete In All Respects Complete Job As Perthe Directions Of Engineer Incharge. ( Stacked Material Whether Serviceable / Unserviceable Material Shall Be The Property Of The Contractor ) 58 Clearing Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood, Trees And Saplings Of Girth Upto 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area Cleared 59 Clearing Grass And Removal Of The Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area Cleared 60 Providing And Fixing Aluminium Fittings Of Approved Make And Manufacture 61 Tower Bolt 62 Handle 63 Hinges 64 Aldrop 65 Providing And Fixing Glass Panes In Windows With Putty, Nails And Wooden Fillets All Complete 4.0Mm Thick Glass Panes 66 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.5 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Incl.All Carriaged Involved Upto Site Of Work Complete In All Respects 67 Half Brick Masonry With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth Including Curing In : 6.15.2 Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 68 Cutting Holes Of Required Size In Brick Masonry Wall For Fixing Of Exhaustfan Including Providing And Fixing 300 Mm Dia Pvc Pipe Conforming Bis-12818 And Making Good The Same Etc. Complete As Per Direction Of Engineer-In-Charge. 69 Making The Opening For Door / Window / Clerestory Window In Brick Masonryincluding Dismantling In Floor Or Walls By Cutting Masonry And Making Good The Damages To Walls, Flooring And Jambs Complete, To Match Existing Surface I / C Disposal Of Mulba / Rubbish To The Nearest Municipal Dumping Ground. 70 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) In Trenches For Foundations, Drains, Pipes, Cables Etc. ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres: 2.9.1 All Kinds Of Soil : 71 Stone Soling-Providing And Laying Hand Packed Stone Soling In Foundation Incl. Ramming, Watering And Consolidating Complete, Cost And Carriages Of All Materials Involved Upto Site Of Work Complete 72 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 5.1.2 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) Incl. All Carriages Complete. 73 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level 5.22.6 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 74 Brick Work With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth Including Curing In : 6.1.4 Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Upto Plinth Level Incl. All Carriages. 75 Providing And Fixing M.S. Grills Of Required Pattern In Frames With M.S. Flats, Square Or Round Bars Etc Including Priming Coat With Approved Steel Primer All Complete. 76 12Mm Cement Plaster Of Mix: 13.1.1 1 : 4 ( 1 Cement : 4 Fine Sand ) Incl. All Carriages Of Materials Involved Complete. 77 Providing Ridges Or Hips Of Width 60Cm Overall Width Plain G.S. Sheets Fixed With Polymer Coated J. Or L Hooks, Bolts And Nuts 8Mm Dia G.I. Limpet And Bitumen Washers Complete 12.4.3 0.50 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 78 Providing And Fixing 15Cm Wide 45 Cm Overall Semi Circular Plain G.S. Sheet Gutter With Iron Brackets 40X3mm Size, Bolts, Nuts And Washers Etc. Including Making Necessary Connections With Rain Water Pipes Complete 12.7.2 0.63 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 79 Cleaning Of Terrace / Loft Water Storage Tank ( Inside Surface Area ) Upto2000 Litre Capacity At All Heights With Coconut Brushes, Duster Etc., Removal Of Silt, Rubbish From The Tank And Cleaning The Tank With Fresh Water Disinfecting With Bleaching Powder @ 0.5Gm Per Litre Capacity Of Tank Including Marking The Date Of Cleaning On The Side Of Tank Body With The Help Of Stencil And Paint And Disposing Of Malba All Complete As Per Direction Of Engineer-In-Charge. ( The Old Date Already Written On Tank Should Be Removed With Paint Remover Or Black Paint And If Date Is Not Written With The Stencil Or Old Date Is Not Removed Deduction Will Be Made @ Rs. 0.10 Per Litre ) ( If During Cleaning Any Gi Fittings Or Ball Cock Isdamaged That Is To Be Repaired By Contractor At His Own Cost And Nothing Extra Will Be Paid On This Account ) 80 Repair To Plaster Of Thickness 12Mm To 20 Mm In Patches Of Area 2.5Sqm And Under, Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing Plastering The Wall Surface With White Cement Based Polymer Modified Self Curing Mortar, Including Disposal Of Rubbish, All Complete As Per The Direction Of Engineer. 81 Disconnecting Damaged Overhead / Terrace Pvc Water Storage Tank Of Any Size From Water Supply Line And Removing From The Terrace Including Shifting At Ground Level As Per Direction Of Engineer. 82 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 83 Providing And Applying Plaster Of Paris Putty Of 2Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete 84 Providing And Applying White Cement Based Putty Of Specified Thickness, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete 85 01 Mm Thick 86 02 Mm Thick 87 Making The Opening For Door / Window / Clerestory Window In Brick Masonry Including Dismantling In Floor Or Walls By Cutting Masonry And Making Good The Damages To Walls, Flooring And Jambs Complete, To Match Existing Surface I / C Disposal Of Mulba / Rubbish To The Nearest Municipal Dumping Ground. 88 Earth Work In Bulk Excavation By Mechanical Means ( Hydraulic Excavator ) Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan ) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. 2.7.1 All Kinds Of Soil : 89 Providing And Fixing On Wall Face Un-Plasticized Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes 12.58.1 75 Mm Diametre 90 Painting On G.S Sheets With Synthetic Enamel Paint Of Approved Band And Manufacture Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution 91 Applying A Coat Of Mordant Solution On G.S. Sheets: 13.62.1 With A Solution Of 38Gms Of Copper Acetate In Liter Of Soft Water 92 Dismantling Manually / Mechanically Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: 93 15.43.1 Water Bound Macadam Road 94 15.43.2 Bituminous Road. 95 Providing And Laying Non-Pressure Np2 Class ( Light Duty ) R.C.C. Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement: 2 Fine Sand ) Including Testing Of Joints Etc. Complete 96 20.5.2 150 Mm Dia. R.C.C. Pipe 97 20.5.4 300 Mm Dia. R.C.C. Pipe 98 20.5.5 450 Mm Dia. R.C.C. Pipe 99 20.5.7 600 Mm Dia. R.C.C. Pipe 100 Providing And Fixing In Position Precast R.C.C. Manhole Cover And Frame Of Required Shape And Approved Quality. 101 20.15.1.1 Rectangular Shape 600X450 Internal Dimensions 102 20.15.1.2 Square Shape 450Mm Internal Dimensions 103 20.15.1.3 Circular Shape 450Mm Internal Diameter 104 Providing And Fixing Of Pvc Pipe ( Type "B" ) Of Approved Qualityas Approved By Incharge Engineer ) In Proper Gradient In Excavated Trenches Including Jointing And Refilling The Excavated Material And Refurbishing Complete Including Charges Of Excavation. 105 150 Mm Dia. 106 100 Mm Dia. 107 75 Mm Dia. 108 50 Mm Dia. 109 Providing And Fixing Of Superior Quality Wall Paper Of Approved Brand, Manufacture, Color And Design With Necessary Adhesive Gum Powder Fully Chemicalised Or Favicol Whicheveris Suitable Including Prepration Of Wall Surface By Way Of Sand Papering, Applying Of Pop / Wall Putty And Other Necessary Repair , All Complete At All Heights As Per Specifications, Drawings And As Directed By Engineer In-Charge Etc. 110 Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia Wire And 1.4 Mm Wide Aperture With Matching Wood Beading 111 Providing And Fixing Of Kitchen Cabinets / Amirah Made Of 19 Mm Thick Ply Wood In Sides, Shelves And Front Shutters And Back With 6Mm Thick Ply Wood Including Lining Of Front Shutters With Sun-Mica / Denmica Or Teak Wood Mirror Polished Along With Fixing Of Mica Inside Completely As Per Approved Drawings And Color Inside Including All Brass Hardware Fittings, Glazing And Drawer Telescopic Channels Etc. Wherever Required & Locking Arrangements ( As Per The Directions Of Eic ) All Inclusive Complete Job. ( Face Area Of The Cabinet Will Be Measured For Payment ) 112 600 Mm 113 450 Mm 114 300 Mm 115 Providing And Fixing Of 0.5Mm Thick Colour Coated High Rib Iron Profile Sheets Of Approved Profile As Approved By Engineer-In-Charge In Roofing Including Carriage Of Same Upto Site Of Work Complete. The Sheet Should Have Protectiveguard Film Of 25 Microns Minimum To Avoid Scratches While Transportation And Should Be Supplied In Single Length Upto 12 Mtr Or As Directed By Engineer-InCharge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5 X 55Mm ) With Epdm Seal Of Same Colour Matching The Shade Of Thesheets. 116 Supply, Installation, Testing, Commissioning Of 5Mp D / N Ip Fixed Bullet Camera 117 Supply, Installation, Testing, Commissioning Of 5Mp D / N Ip Varifocal Camera ( 2.8-13 Mm ) 118 Supply, Installation, Testing And Commissioning Of 8 Sata, 64 Channel, Nvr 119 Supply, Installation, Testing And Commissioning Of 4 Tb Hdd For Nvr 120 Supply, Installation, Testing, Commissioning Of Fully Loaded 9U Rack 121 Supply, Installation, Testing, Commissioning Of 2Mp D / N Ip 25X Ptz Camera 122 Supply, Installation, Testing, Commissioning Of Outdoor Rack 123 Supply, Installation, Testing, Commissioning Of Fully Loaded 12 Port Liu Including Pig Tails 124 Supply, Installation, Testing, Commissioning Of Cable Manager Including All Fittings 125 Supply, Installation, Testing, Commissioning Smart Managed 24 Port Layer 2 Network Poe Switch 126 Supply, Installation, Testing, Commissioning Smart Managed 16 Port Poe Switch With Sfp 127 Supply, Installation, Testing, Commissioning Smart Managed 08 Port Poe Switch With Sfp 128 Supply, Installation, Testing, Commissioning Of 55 Inch Led Tv 129 Supply, Installation, Testing Commissioning Of Cat 6 Cable 23 Awg Solid Copper Conductor, Fr Pvc Jacket 130 Supply, Installation, Testing Commissioning Of Outdoor Cat 6 Cable 23 Awg Solid Copper Conductor, 131 Supply, Installation, Testing And Commissioning Of Single Mode Dual Fiber 1G Sfp Module Compatible With Switches 132 Supply Of Lc-Sc / Lc-Lc / Sc-Sc Duplex Fibre Patch Cord Single Mode -9 / 125Um- 3 Meter 133 Providing & Laying Conduit & Other Accessories Of Different Sizes Including All Accessories 134 Splicing Of Optical Fiber Cable 135 Supply And Laying Of 06 Core Sm 9 / 125Um Double Sheath, Csta, Unitube, Optical Fiber Cable 136 Supply And Laying Of Multi Stranded 2 Core2.5 Sqm Wire 137 Supply, Installation, Testing, Commissioning Of Fully Loaded 17 U Rack 138 Supply, Installation, Testing, Commissioning Of 1 Kva Ups 139 Supply, Installation, Testing, Commissioning Of Other Electrical Accessories For Making System Functional ( Hdmi Cable, Mouse, Mccb, Surge Arrestors Etc ) 140 Point Wiring For Switch Controlled Primary Light Points With 3X1.5 Sq Mm ( P+N+E ) Frls Pvc Insulated 660 / 1100 Volt Grade Flexible Strandedcopper Conductor Wiresin Recessed Orsurface Conduitng System And Incl The Cost Of Supplying And Fixing Modular Grid Plate Mounted Flush Mounted 240 Volts 6 Amp Control Switch Of Approved Quality And Colour Housed In Zinc Chromate Passivity Gi Boxes With Modular Cover Platecomplete As Per Specification And As Required .The Job Includes Providing And Laying Of Circuit Wiring With 3 X 1.5 Sq.Mm Pvc Insulated Multistranded Copper To Be Laid Through Pvc Conduitfrom Db To First Switch In Sub Circuit Complete Job Excluding Cost Of Condits . ( Separate Wiring For Normal And Invertor Supply Is To Be Provided And No Extra Circuit Wiring Shall Be Paid What So Ever Reason Or Length ) Complete As Required And Samples Of Wires / Switches / Sockets Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominatedby Department If Required. ( Excl Cost Of Conduitng ) 141 Point Wiring For Ceiling Fan Pointswith 3X1.5 Sq Mm ( P+N+E ) Frls Pvc Insulated 660 / 1100 Volt Grade Flexible Stranded ( 50 Strands Of 0.25 Mm Dia. ) Copper Conductor Wires In Recessed Or Surface Conducting System And Incl The Cost Of Supplying And Fixing Modular Grid Plate Mounted Flush Mounted 240 Volts 6 Amp Control Switch And 240 Volts 300 Watt 5 Step Electronic Speed Regulator Of Approved And Colour Housed In Zinc Chromate Passivity Gi Boxes With Modular Cover Plate And With Inter Connections Complete As Per Specification And As Required.The Job Includes Providing And Laying Of Circuit Wiring With 3 X 1.5 Sq.Mm Pvc Insulated Multistranded Copper To Be Laid Through Pvc Conduitfrom Db To First Switch In Sub Circuit Complete Job Excluding Cost Of Condits . ( Seperate Wiring For Normal And Invertor Supply Is To Be Provided And No Extra Circuit Wiring Shall Be Paid What So Ever Reason Or Length ) Complete As Required And Samples Of Wires / Switches / Sockets Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominated By Department If Required. ( Excl Cost Of Conduitng ) 142 Point Wiring For 10 Amp Socket Out Lets With 3X2.5 Sq Mm ( P+N+E ) Frls Pvc Insulated 660 / 1100 Volt Grade Flexible Stranded ( 50 Strands Of 0.25 Mm Dia. ) Copper Conductor Wires Inrecessed Or Surface Conducting System Incl The Cost Of Supplying And Fixing Modular Grid Plate Mounted Flush Mounted 3 No 240 Volts 6 Amp 5 Pin Socket Out Let Along With 3 No''s Of 6 Amp Control Switch Of Approved Quality And Colour Housed In Zinc Chromate Passivity Gi Boxes With Modular Cover Plate And Inter Connections And Including Cost Of Loop Earthing With 2.5 Sq Mm Frls Pvc Insulated 660 / 1100 Circuit Wiring ( From Db To First Switch In The Sub Circuit ) Complete As Per Specification And As Required Volt Grade Flexible Strandedcopper Conductor Wires Complete As Per Specifications And As Required , Complete Job Excluding Pvc Conduiting . The Job Includes Providing And Laying Of Circuit Wiring Of Same Sizefrom Db To First Switch In Sub Circuit ( Maximum Two Points Shall Be Connected / Provided In One Circuitand No Extra Circuit Wiring Shall Be Paid What So Ever Reason Or Length ) Complete As Required And Samples Of Wires / Switches / Sockets Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominated By Department If Required. ( Excl Cost Of Conduitng ) 143 Point Wiring For 16 Amp Socket Out Lets ( Two Out Lets Wired In One Sub Circuit ) With 3X4 Sq Mm ( P+N+E ) Frls Pvc Insulated 660 / 1100 Volt Grade Flexible Stranded ( 56 Strands Of 0.3 Mm Dia. ) Copper Conductor Wires In Recessed Or Surface Conducting System And Incl The Cost Of Supplying And Fixing Modular Grid Plate Mounted Flush Mounted 240 Volts 16 Amp 6 Pin Combined Shuttered Socket Out Let Along With 240 Volt 16 Amp Control Switch Of Approved Quality And Colour Housed In Zinc Chromate Passivity Gi Boxes With Inter Connection Complete As Per Specifications And As Required.The Job Includes Providing And Laying Of Circuit Wiring Of Same Sizefrom Db To First Switch In Sub Circuit ( Maximum Two Points Shall Be Connected / Provided In One Circuitand No Extra Circuit Wiring Shall Be Paid What So Ever Reason Or Length ) Complete As Required And Samples Of Wires / Switches / Sockets Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominated By Department If Required. ( Excl Cost Of Conduitng ) 144 Supply, Installation, Testing And Commissioning Of12 Watt Led Surface Mounted ( Square / Round ) Light Fittingshaving Crca / Aluminium Body , Minimum Lumens 100 Lm / W , The Luminaire Housing Should Be Crca / Aluminium And The Luminair Optics Shall Have A High Efficency Withtransmittance , Average Life Of 50000 Hrs Operating Temperature -10 C To + 45 Cincl Making Of Necessary Connections. ( Samples Are To Be Approved Byengineer Incharge Before Execution After Submission Of Data Sheeton Oem Letter Pad Or Third Partyto Be Nominatedby Department If Required ) .The Job Further Includes Replacement Warrenty Of Fixture ( If Damaged / Burnt Out What So Ever Reason ) For A Period Of Two Years Reckoned From Date Of Sucessful Commissioning / Handing Over Of Site To Intending Department. 145 Supply, Installation, Testing And Commissioning Of50 Wattsled Flood Lighting Luminarieshaving Crca / Aluminium Body , Minimum Lumens 100 Lm / W , The Luminaire Housing Should Be Crca / Aluminium And The Luminair Optics Shall Have A High Efficency Withtransmittance , Average Life Of 50000 Hrs Operating Temperature -10 C To + 45 Cincl Making Of Necessary Connections. ( Samples Are To Be Approved Byengineer Incharge Before Execution After Submission Of Data Sheeton Oem Letter Pad Or Third Partyto Be Nominatedby Department If Required ) The Job Further Includes Replacement Warrenty Of Fixture ( If Damaged / Burnt Out What So Ever Reason ) For A Period Of Two Years Reckoned From Date Of Sucessful Commissioning / Handing Over Of Site To Intending Department. 146 Supply, Installation Testing And Commissioning Of1200 Mm Sweep Ceiling Fanswith 3 Way Ceiling Rose Complete Incl Making Of Necessary Connections. ( Samples Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominated By Department If Required ) 147 Supply, Installation Testing And Commissioning Of300 Mm Sweep Shutter Type Exhaust Fanswithway Ceiling Roseincl Making Of Necessary Connections And Making Of Necessary Space In Walls / Windows As Per Site. ( Samples Are To Be Approved Byengineer Incharge Before Execution Or Third Partyto Be Nominatedby Department If Required ) The Job Further Includes Replacement Warrenty Of Fixture ( If Damaged / Burnt Out What So Ever Reason ) For A Period Of Two Years Reckoned From Date Of Sucessful Commissioning / Handing Over Of Site To Intending Department. 148 Supply, Installation, Testing And Commissioning Of Ac / Dc Bells Of Standard Make With Its Batteries. 149 Supply, Installation, Testing And Commissioning Of 2 Feet Long Led Flat Batten Tube Lightsincl Making Of Necessary Connections As Mirror Lights.The Job Further Includes Replacement Warrenty Of Fixture ( If Damaged / Burnt Out What So Ever Reason ) For A Period Of Two Years Reckoned From Date Of Sucessful Commissioning / Handing Over Of Site To Intending Department. 150 Supplyand Fixing Modular Blanking Plates On Exixting Modular Switch Plates, Excluding Cost Of Plates. 151 Supply And Fixing Of Metal Boxesof Following Sizes On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Paintinng Etc. As Required 152 200 Mmx 250 Mm X60 Mm Deep 153 250 Mm X300 Mmx60 Mm Deep 154 Supply And Fixing Of25 Mm Dia Medium Grade Pvc Conduit Incl Its Allied Accessories Like Bends, J Boxes Etc For Laying Of Wires Recessed In Walls Incl Refcaing Of Walls Or Fitted With Necessary Clips And Rowel Plugs Complete. 155 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way, Double Door 156 Supplying And Fixing Of 32-40 Amp Rating Dp 240 / 415 Volts ( 10 Ka ) "C" Curve Mcb`Ssuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc. As Required. 157 Supplying And Fixing Of 63 Ampsrating Dp Mcb 240 / 415 Volts ( 10 Ka ) "C" Curve Mcb Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc. As Required. 158 Supplying And Fixing Of 5 Amps To 32 Amps Pole Rating 240 / 415 Volts ( 10 Ka ) "C" Curve Mcbsuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc. As Required. 159 Supplying And Fixing Of 32Amps Metal Clad Industrial Socket Outlet Having Fitted With 32 Amps Dp Mcb And Top For Ac Points 160 Supplyand Fixing Single Pole Blanking Plates On Existing Mcb Boxes, Excluding Cost Of Boxes. 161 Earthing With G.I. Earth Pipe 4.5 Metre Long, 40Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt ) As Required 162 Supply, Laying, Connecting And Commissioning Of 50 Sq Mm 3.5 Core Xlpe / Pvc Insulated And Steel Armoured 1.1 Kv Grade Al Cablewith P / F Of Alminium Thimbles Dully Crimpped On I / P And O / P Side Laid As Per Site Condition From L T Panel To L T Pole. 163 Supply, Laying, Connecting And Commissioning Of 35 Sq Mm 2 Core Xlpe / Pvc Insulated And Steel Armoured 1.1 Kv Grade Al Cablewith P / F Of Alminium Thimbles Dully Crimpped On I / P And O / P Side Laid As Per Site Condition From L T Panel To L T Pole. 164 Sitc Of 400 Mm Sweep Wall Fan 165 Supply Laying Testing And Commissioning Of Following Size Pvc Insulated Multistraded Copper Wire 166 1.5 Sqm 167 2.5 Sqm 168 4 Sqm 169 6 Sqm 170 10 Sqm 171 Sitc Of Following Switch Gear Devices Of Non Modular To Be Fitted On Hylum Sheets Of Required Size Incl. Cost Of Hylum Sheets 172 06 Amp Switch 173 06 Amp Socket 174 16 Amp Switch 175 16 Amp Socket 176 Fan Dimmer 177 Sitc Of 20 Watt Four Feet Long Tube Light 178 Supply, Installation, Testing And Commissioning Of90-100 Wattsled Flood Lighting Luminarieshaving Crca / Aluminium Body , Minimum Lumens 100 Lm / W , The Luminaire Housing Should Be Crca / Aluminium And The Luminair Optics Shall Have A High Efficency Withtransmittance , Average Life Of 50000 Hrs Operating Temperature -10 C To + 45 C Incl Making Of Necessary Connections. ( Samples Are To Be Approved Byengineer Incharge Before Execution After Submission Of Data Sheeton Oem Letter Pad Or Third Partyto Be Nominatedby Department If Required ) The Job Further Includes Replacement Warrenty Of Fixture ( If Damaged / Burnt Out What So Ever Reason ) For A Period Of Two Years Reckoned From Date Of Sucessful Commissioning / Handing Over Of Site To Intending Department. 179 Sitc Of Angle / Batten Holder With 09 Watt Led Lamp 180 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc. Complete11.52.2 Size Of Tile 600X600 Mm 181 Kota Stone Slab Flooring 25 Mm Thick Over 20Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing, Polishing And Curing Complete With Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) : 182 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 183 5.9.1 Foundations, Footings, Bases Of Columns Etc. For Mass Concrete. 184 5.9.2 Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses Etc. 185 5.9.3 Suspended Floors, Roofs, Landings, Balconies And Access Platforms. 186 5.9.4 Shelves ( Cast-In-Situ ) 187 5.9.5 Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers. 188 5.9.6 Columns, Pillars, Piers, Abutments, Posts And Struts. 189 5.9.7 Stairs ( Excluding Landings ) Except Spiral Staircases. 190 Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc. ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed: 2.8.1 All Kinds Of Soil : 191 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge ( Second Class Kail Wood ) 192 35 Mm Thick 193 30 Mm Thick 194 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Second Class Kail Wood ) 195 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 4Mm Thick Float Glass Panes Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws ( Second Class Kail Wood ) 196 35 Mm Thick 197 30 Mm Thick 198 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge : ( Second Class Kail Wood ) 199 35Mm Thick 200 30 Mm Thick 201 Providing And Fixing Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes Channels, Plates Etc. Including Welding , Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete , Including Fixing The Railing With Necessary Accessories And Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc. Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) . 202 Providing And Laying 60Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M-30 Grade Made By Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design / Shape Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Filling The Joints With Coarse Sand Etc. All Complete As Per Direction Of Engineer-In-Charge. 203 Providing And Laying Tactile Tile ( For Vision Impaired Persons As Per Standards ) Of Size 300X300x9.8Mm Having With Water Absorption Less Than 0.5% And Conforming To Is: 15622 Of Approved Make In All Colours And Shades In For Outdoor Floors Such As Footpath, Court Yard, Multi Modals Location Etc., Laid On 20Mm Thick Base Of Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) In All Shapes & Patterns Including Grouting The Joints With White Cement Mixed With Matching Pigments Etc. Complete As Per Direction Of Engineer-In-Charge. 204 P / F Of Full Body Anti-Skid Outdoor Pavement Tile With Diagonally Ribbed Surface Laid Over A Bed Of Cement Sand Mortar In 1:4 Mix Including Cost And Carriage Of All Materials Involved Upto Site Of Work Complete In All Respects. Size 398Mm X 398Mm X 16Mm 205 Chequerred Precast Cement Concrete Tiles 22Mm Thick In Footpath And Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing, Cleaning And Curing Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) .11.29.1 Light Shade Using White Cement 206 Providing And Laying Gang Saw Cut Of Specified Thickness, Mirror Polished Pre- Moulded And Pre Polished Machine Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring Cut Granite Stone Of Required Size And Shape Of Approved Shade, Colour And Texture In Footpath, Flooring In Road Side Plazas And Similar Locations, Laid Over 20Mm Thick Base Of Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) Including Grouting The Joints With White Cement Mixed With Matching Pigment, Epoxy Touch Ups Etc. Complete As Per Direction Of Engineer-InCharge.16.90.1 18 Mm Thick 207 Providing Edge Moulding To 18 Mm / 16 Mm Thick Marble Stone Counters, Vanities Etc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge 8.3.2 Granite Work 208 Providing And Fixing 3 Layer Pp-R ( Poly Propylene Random Copolymer ) Pipes Conforming To Is: 15801, Uv Stabilized And Anti-Microbial Fusion Welded, Having Thermal Stability For Hot And Cold Water Supply Including All Pp-R Plain And Brass Threaded Polypropylene Random Fittings. This Includes Testing Of Joints Complete As Per Direction Of Engineer-InCharge. 209 20Mm Od ( Sdr-7.4 ) 210 25Mm Od ( Sdr-7.4 ) 211 32Mm Od ( Sdr-7.4 ) 212 40Mm Od ( Sdr-7.4 ) 213 Providing And Fixing Pvc Flexible Banners Of Different Sizes With Computerized Digital Printing Including Fixing The Same With Necessary Framming Of Ms Hollow Sections Incl. All Cost, Carriage And Complete Job. 214 Supplying And Stacking At Site Stone Screening 215 Excavation In Water Bound Macadam Road Including Stacking Of Serviceable And Unserviceable Material Separately And Disposal Of Unserviceable Material Lead Upto 50 M And Lift Upto 1.5 M, Disposed Material To Be Neatly Dressed 216 6 Mm Cement Plaster To Ceiling Of Mix 1 : 3 ( 1 Cement : 3 Fine Sand ) 217 Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade On New Work ( Two Or More Coats ) Over And Including Priming Coat With Water Thinnable Cement Primer 218 French Spirit Polishing, Two Or More Coats On New Works Including A Coat Of Wood Filler 219 Melamine Polishing On Wood Work ( One Or More Coats ) 220 Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Meters Lead As Per Direction Of Engineer-InCharge: 221 15.2.1 1:3:6 Or Richer Mix ( I / C Equivalent Design Mix ) 222 15.2.2 1:4:8 Or Leaner Mix ( I / C Equivalent Design Mix ) 223 Demolishing R.C.C. Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge. 224 Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: 15.7.4 In Cement Mortar 225 Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead As Per Direction Of Engineer-In-Charge: 15.9.2 In Cement Mortar 226 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Meters Lead : 227 15.12.1 Of Area Of 3 Sqm. And Below 228 15.12.2 Of Area Beyond 3 Sqm. 229 Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Meters Lead. 15.23.1 For Thickness Of Tiles 10 Mm To 25 Mm 230 Dismantling Roofing Including Ridges, Hips Valleys And Gutters Etc., And Stacking The Material Within 50 Meters Lead Of :15.28.1 G.S. Sheet 231 Providing And Fixing G.I. Chain Link Fabric Fencing Of Required Width In Mesh Size 50X50 Mm Including Strengthening With 2 Mm Dia Wire Or Nuts, Bolts And Washers As Required Complete As Per The Direction Of Engineer-InCharge. 16.25.1 Made Of G.I. Wire Of Dia 4 Mm 232 Supply Ang Fixing In Position Welded Mesh 30X30mm Including Cost Of Nails To Fix The Mesh To The Posts As Per The Directions Of Engineer Incharge 233 Providing And Fixing Pvc Fittings ( Type ''''B'''' ) Of Approved Quality 234 Plain Bend 75 Mm Dia 235 Plain Bend 100 Mm Dia 236 Plain Tee 75 Mm Dia 237 Plain Tee 100 Mm Dia 238 Collar 75 Mm Dia 239 Collar 100 Mm Dia 240 Floor Trap 75 Mm Dia 241 Floor Trap 100 Mm Dia 242 P / Strap 100 Mm Dia 243 Providingandfixingwater Closet Squattingpan ( Indian Typew.C. Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Liter Low Level White P.V.C.Flushingcistern, Includingflushpipe ( Ofapprovedmake ) With Manuallycontrolleddevice ( Handlelever ) Conforming Tois:7231, Of Approvedmake Like ( Parryware / Hindware / Cera Orequivalent With All Fittingsandfixturescomplete, Includingcuttingand Makinggood Thewallsandfloorswhereverrequiredwhite Vitreouschinaorissa Patternw.C. Panof Size 580X440 Mm With Integral Type Foot Rests. 244 P / F Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Liter Low Levelwhite P.V.C.Flushingcistern, Includingflushpipewith Manuallycontrolleddevice ( Handle Lever ) , Conforming Tois:7231, Of Approved Makelike ( Parryware / Hindware / Ceraor Equivalentwithallfittingsand Fixturescomplete, Including Cutting Andmakinggoodthewallsand Floors Wherever Required: W.C. Pan With Isi Marked White Solid Plastic Seat And Lid. 245 Providing And Fixingsolid Plastic Seat With Lid For Pedestal Typew.C. Pan Complete: 246 Providingandfixingwashbasinwithc.I.Brackets, 15Mmc.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern And Makey As Approved By Incharge Engineer, Including Painting Of Fittingsandbrackets, Cutting And Making Goodthe Walls Wherever Required : 247 Providingandfixingp.V.Clowlevelflushingcisternwith Manually Controlleddevice ( Handlelever ) Conformingtois:7231, Withall Fittingsandfixturescomplete:10Liter Capacity. 248 Providing And Fixing Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink Asperi.S.13983 Asapprovedbyinchargeengineer Withc.I. Bracketsandstainlesssteelplug40mm, Includingpaintingof Fittingsandbrackets, Cutting And Making Goodthe Walls Wherever Required Of Standard Quality As Approved By Incharge Engineerkitchen Sink With Drain Board 510X1040mm Bowl Depth 250Mm 249 P / F C.P Sanitary Fittings Of Approved Quality. 250 Bib Cock 251 Angle Valve 252 Mixer 253 Towel Rail Single 600 Mm Long 254 Health Faucet With Required Chain Tube 255 Grating 100 Mm Dia 256 Grating 75 Mm Dia 257 Paper Holder 258 Soap Case 259 Cp Connection 260 Pvc Connection 261 Fillingavailableexcavatedearth ( Excluding Rock ) In Trenches, Plinth, Sidesoffoundationsetc.Inlayersnot Exceeding20cmin Depth, Consolidating Eachdeposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 262 Pumpingout Water Causedbysprings, Tidal Or Riverseepage, Broken Water Mains Or Drains And The Like. 263 Removalofunhygienicmaterials ( Soclassifiedbythesite Engineer ) From Designated Sites And Its Disposal As Per Directions, All Inclusive. 264 Dry Random Rubble Masonry With Hard Stone Fromquarry Including Bondstone Andcarriageof Samefrom Approved Source Uptosite Of Work, Complete 265 Finishingwith Epoxypaint ( Twoor Morecoats ) Atall Locations Preparedand Applied As Per Manufacturer’S Specifications Includingappropriate Priming Coat, Preparation Of Surface, Etc Complete On Steel Work 266 Supply And Erecting Of Precast Reinforced Cement Concrete Road Divider As Per Apporved Drawing And Design Duly Painted With Epoxy Paint Including Priming Coat ( In Unit Of 2.0 To 2.5 Mt Of Length Of 1 Mt Hight With Base Width Of 0.45 M And Flange Width Of 0.15 Mt In Tapered Form Including Transportion And Placement At Site By Hydraulic Crane As Per Requirements And Management Of Traffice During Placing ( 1X2.5 Mt ) Of Approved Brand And Manifacture. 267 Providing And Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6mm, With 40Mm Dia, Steel Pulleys, Complete With Bolts, Nuts, Locking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer, 268 Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Of 27 Mm And 37Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50Mm Long With 6Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80 Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, Complete Job 269 Providing And Fixingof Gyser Of Approved Make 50Litre Capacity With All Necessary Fittings. 270 Clearanceofseptictankbyway Of Engagementof Suckers For Clearing, Taking Out All The Slush, Unhygienicmaterialfromthetanksanddisposalof The Same Beyond Municipal Limits Complete Job. 271 Providing And Fixing Blind Curtains Incld Cost Of Bracketsandstoppersasperdirectionofengineer Incharge At Site Complete. 272 Repair / Renovationandtestinghotwatergyser50 Litre Capacity By Way Of Repairing Of Essential Thermostat / Elements Etc And Making Necessary Connectionsasperdirectionofengineerinchareat Site. 273 Providingandfixingof Powdercoatedaluminum Partitionconsistingofaluminumsections63.5Mm ×38.1Mm ×2Mm Thick Powder Coated Conformingtois733andis1285. The Sections Would Be Installed At An Interval Of 3''6'''' Verticallyandbottomsectionofsize114.60×44.45 ×2Mmalmuniumsnap Beading For Glazing / Paneling Etc. And 5 Mm Thick Float Transparent Glass Including Providingscrewlessalmuniumglazingclip.Bottom Upto4''6''''htwillbeprovidedwith12mmthickboth Side Pre Laminated Particle Board Flat Pressed 3 Layer Conformingtois12823gradeitypeiiofbhutan / Nepal / Greenlamiofinteriorgradecompletewith Fixingclips, Fasteners, Fillingupofgapsatjunction, Top, Bottom&Withrequiredpvc / Nepprenefeltetc. Thejointsshallbesmooth, Mitredandjointedwith Cleatangleetcasperdirectionofengineer / Site Incharge Complete Job. 274 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 4.4.3 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Incl. All Carriages Involved Complete.
|