Tender For Electrification Work Of Iti Building At Kareda District Bhilwara -Wiring Of Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Inrecessed Isi Marked Mms ( Is:9537 P - Iii ) Virgin Material Pvc Conduit & It"Sisi Marked ( Is:3419-1988 ) Accessories, Round Tiles, 1.2 Mm Thickhot Dipped Galvanized Modular Box With Earth Terminal, 10A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Holder / 3 Way Connector, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated Sheet"S & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 3 Short Point ( Up To 3 Mtr. ) 4 Medium Point ( Up To 6 Mtr. ) 5 Long Point ( Up To 10 Mtr. ) 6 Wiring Of Twin Control Light Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) In Recessed Isi Markedmms ( Is:9537 P - Iii ) Pvc Conduit & It"S Isi Marked ( Is:3419-1988 ) Accessories, Round Tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox Of 1.2 Mm Thickwith Earth Terminal, 2 Nos10 A Two Way Modular Switch, 3 Pin Ceiling Rose / Holder / 3 Way Connector , Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated Sheet"S & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 7 Long Point ( Up To 10 Mtr. ) 8 Wiring Of 3 / 5 Pin 6 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Sizefr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Gradeand 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade ( Is:694 ) Inrecessed Isi Marked Mms ( Is:9537 P - Iii ) Pvc Conduit & It"S Isi Marked ( Is:3419-1988 ) Accessories, Hot Dipped Galvanizedmodular Box Of 1.2 Mm Thick With Earth Terminal, 10 A Modularswitch, 3 / 5 Pin 6 A Modular Socket, Modular Face Plate With Grid Plate, Screws, Making Connections, Testing Etc. As Required.For Specification Of Copperconductor, Phenolic Laminated Sheet"S & Electrical / Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 9 On Board 10 Short Point ( Up To 3 Mtr. ) 11 Medium Point ( Up To 6 Mtr. ) 12 Long Point ( Up To 10 Mtr. ) 13 S&F Following Sizes ( Dia. ) Of Isi Marked Virgin Material Mms ( Is:9537 P - Iii ) Pvc Conduit Along Withisi Marked ( Is:3419-1988 ) Accessories As Requiredinrecessincludingcutting The Wall, Covering Conduit And Making Good The Same As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 14 20 Mm 15 25 Mm 16 32 Mm 17 40 Mm 18 50 Mm 19 S&F Following Sizesof Isi Marked ( Is:14927 P - Ii ) Virgin Materialupvc Trunking Along With Accessorieslike Coupler, Inner, Outer, Elbow, Square Box, Tee, End Cap Etc. On Surfacewithscrews, Expansionfastenersas Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 20 100 Mm X 50 Mm 21 150 Mm X 50 Mm 22 Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Class 5 Stranding In Acc. To Is:8130 / Iec 60228 Forlower Watt Loss , Oxygen Free For Less Chances Of Oxidization, Insulation Pvc Type A / C / D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping Making Connections With Copper Lugs Of Suitable Size, Ferrules, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 23 1 X 1.5 Sq.Mm 24 2 X 1.5 Sq.Mm 25 3X 1.5 Sq.Mm 26 1X 2.5 Sq.Mm 27 2 X 2.5 Sq. Mm. + 1X1.5Sqmm 28 2 X 4.0 Sq. Mm. + 1 X 2.5 Sq. Mm. 29 2 X 6.0 Sq. Mm. + 1 X 4.0 Sq. Mm. 30 2 X 6.0 Sq.Mm 31 2 X 4.0 Sq.Mm 32 4 X 10.0 Sq.Mm 33 4 X 16.0 Sq.Mm 34 Supplying And Drawing Pe Insulated & Pvc Sheathed Unarmoured Telephone Cable With 0.5 Mm Dia. Solid Annealed Electrolytic Grade Bare Copper Conductor As Per Is: 8130 / 84 &Confirming To Tec Specification Gr / Wir / 06-03 March 2002In Existingsurface Or Recessed Conduit / Casing Capping. Including Ferruling On Each Pair For Identification Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 35 2 Pair 36 Supply And Laying Of Pe Insulated Jelly Filledarmouredtelephone Cable. With 0.6 Mm Thick Solid Annealed Bare Copper Conductor And Confirming To Tec Specificationsconfirming. To Dot Gr / Cug-01 / Aug.2003 In Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Necessary Connection, Testing Etc. As Required Of Size. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 37 10 Pair 38 50 Pair 39 Supplying And Drawing Coaxial Cable 75 Ohm Impedance With Foam Pe Insulated Solid Bare Copper Inner Conductor, And Ist Outer Conductor Of Bonded Alum. Tape And Second Outer Conductor Ofalum. Alloy Braidin Existingsurface Or Recessed Conduit / Casing Capping Including Making Connections As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 40 Rg - 6 41 P / Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From99.90 % Purity Copper, Stranding In Acc. To Is:8130 / Iec 60228 Forlower Watt Loss , Oxygen Freefor Less Chances Of Oxidization, Insulation Pvc Type A / C / D , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Is:3961 Part 5, Existing Pipe / Open Trench / Cable Tray / On Surface Including Making Connection Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 42 2.5 Sq.Mm 3 Core Flat / Round 43 4.0 Sq.Mm 3 Core Flat / Round 44 6.0 Sq.Mm 3 Core Flat / Round 45 P & F Paper Phenolic Resin Bondedlaminates Confirming To Is : 2036 -1995 For Boxes / Frames Including Making Holes For Switches Etc, With Brass Screws, Washers / Zinc Platednut And Bolts As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 46 3.0 Mm Thick 47 4.8 Mm Thick 48 6.4 Mm Thick 49 P & F 1.2Mm Thickm.S. Recessed Fan Box, Hexagonal / Round Of Size 130 Mm Dia, Depth 75Mm, 12 Mm Dia Rod Fan Hook With 100 Mmlength Extended On Each Side . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 50 P & F Krone Module With Base Framein The Recess / Surface Made Out Of 1.2 Mm Thicksheet Steel Box, Front Openable, Having Locking Arrangements Duly Powder Painted, Including Dressing, Ferrulingandpunchingof Telephone Cable With Krone Tool Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 51 10 Pairs 52 50 Pairs 53 Supplying And Fixing Of Power Plug Point With Modular Accessories As Per Pwd Specification For Electrical Works, On Hot Dipped Galvanized Modular Box Of 1.2 Mm Thick With Earthing Terminal / Connector On Surface Or In Recessed With Suitable Size Of Modular Face Place With Grid Plate And Cover Plate Including Cost Ofisi Marked Modular 16 Amp. Switch ( Is :3854 ) And 6 / 16 Amp. Socket Outlet ( Is:1293 ) Making Connection , Testing , Etc. As Required. For Specification Ofwiring Accessories Refer Chaptere - 07Related Item & For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 54 P&F Metal Clad / Plastic Industrial Plug Top & Socket Unit With Pin And Sleeve Type Contact On Porcelain / Bakelite Base In Recessed / Surface Mounting Heavy Duty Enclosure Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted ( Without Mcb ) Including Making Connections, Testing Etc.As Required.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 55 20 Amp, 3 Pin + Scrapping Earth, 4 Module 56 32 Amp, 5 Pin + Scrapping Earth, 8 Module 57 Making Of Hole In Wall ( Brick / Stone ) Of Required And Placing Np-2 Rcc Pipe Ring Of Required Size For Housing Exhaust Fan And Making Good The Same, With Cement Plaster Required Of Following Size. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 58 Up To 457 Mm Size 59 Providing & Fixing Ofextra Down Rod Of 15 Mm Dia . Erw ( Electrical Resistance Welded ) Of 1.6Mm Nominal Thick Medium Duty Steelpipe Including Cutting, Threading, Drilling, Fixing Quarter Pin Etc As Reqd.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 60 Providing & Fixing Of Single / Multi Tone Electronic Call Bell As Per Pwd Specification For Electrical Works, Including Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 61 Providing & Fixing Of Modular Type Switch / Bell Push Duly Isi Marked ( Is :3854 ) With Cm / L No. Printed And Made Out Of Unbreakable And Fire Retardant Vergin Uv Stabilized Polycarbonatewith Brass Terminals And Captive Screws & Silver Alloy Contact Tipwith Ip-20 Rating , Minimum Width Ofswitch Toggle ( Push Part ) Should Not Less Then 20Mm, Includingall As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 62 10 A One Way Switch 63 32 Amp. 2 Moduleswitch With Ledindicator 64 Providing & Fixing Of Modular Type Lockable Feature Socket Dulymade Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tipwith Ip-20 Rating , Includingall As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 65 6 A3 / 5 Pin Shuttered Socket 66 25 Amp. 2 Module Socket 67 Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked ( Is 11037:1984 ) With Cm / L No. Printedmade Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tipwith Ip-20 Rating , Includingall As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. As Required.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 68 5 Step Fan Regulator 2 Module 360 Dgree Rotating 69 Providing & Fixing Of Following Modular Accessories As Per Pwd Specification For Electrical Works, Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tipwith Ip-20 Rating , Includingall As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. As Required.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 70 T.V. Coaxial Socket 71 Rj-11 Telephone Jack Double Line 72 Blanking Plate 73 Modular Mcb 6 A To 32 Adp 74 Providing & Fixing Offollowing Size Mounting Grid Plates With Cover Plates Made From Fire Retardent Uv Established High Performance Engineering Plastic Suitable For All Universal Metal Boxes For Front Installation & Removal Direct Fit Type Complete In All Respect.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 75 1 / 2 Module 76 8 Module 77 Providing & Fixing Ofwiring Accessories Oem Fabricated Following Size Gi Box Of 1.2 Mm Thick With Earthing Terminal And Adjustable Floating Clamp In Recess / Surface Suitable For Modular Accessories As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 78 1-2 Module 79 6 / 8 Module 80 Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Powder Coated Extruded Aluminiumhousing With In Built Driver, System Lumen Efficacy = 110 Lm / Watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection , Thd < 10% , P. F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 81 1170Mm ( + / -10% ) Led Batten With Min. Lumen Output 2200 Lm 82 570Mm ( + / -10% ) Batten With Min. Lumen Output 1000 Lm 83 Providing & Fixing Of Ip-20 Led Recessed / Surface Mounted, Round / Sqauresmd Mid Power Led Downlight With Power Coated Die-Cast Aluminum Housingwith Uv Stabilized Non Yellowish Diffuser Withbis Complience 2.5 Kv Surge Protected Isolated Driver, With Short & Open Circuit Protection, Having Efficiency > 85% . System Lumen Efficacy Of = 110 Lm / Watt, Thd < 10 % , Pf.=0.95, Cri >80, Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. 84 Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 85 Surface Mounting ( With Extruded Alumn. Housing ) 86 Minimum Lumen Output 1300 Lm 87 Minimum Lumen Output 1950 Lm 88 Providing & Fixing Of Ip20, 2"X2" Led Surface / Recessedmounting Mid Power Smd Type Led Light Fixture Not Less Than 50Mm Housing Depth Made From Crca Sheet Steel Housing, High Purity / Transmisivity Uv Stabilized Non -Yellowish Diffuser For Uniform Light Distribution. High Efficiency With 4 Kv Internal / External Surge Protection Bis Certified Isolated Driver Having Efficiency > 85% , With Short & Open Circuit Protection ( Integral With Light Fixture ) . System Lumen Efficacy Of = 120 Lm / Watt , Thd < 10 % , P.F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. 89 Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 90 Surface Moutning 91 Minimum Lumen Output 4200 Lm 92 Providing & Fixing Of Ip65 Ik08 Rated Integrated Smd Mid Power Led Bulk Head Type Light Fixture Made From Pressure Die Cast Al Housing Suitable With Integral Driver, System Lumen Efficacy =100 Lm / Watt Output , Thd < 10% , P.F.=0.95, Cri >80 , Life Time Of Minimum50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends, Cct 3000°K / 4000°K / 5700°K / 6000°K / 6500°K ( As Per Ansi Bin ) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Ofbis Standard Andtrade Mark Certificate ( T.C. ) . Manufactures Word Mark / Name Engraved / Embossing / Screen Printing Onhousing. Surge Protection 4 Kv. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. ( Lm79 & Lm80 ) Certificate / Report From Oem Shall Be Submitted.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 93 Minimum Lumen Output 1000 Lm 94 Providing & Fixing Of 400 Mm Sweepbldc Technology Oscillating Type Wall Mounting / Pedestal Typefans With Three Speed, On Andoff Position, Double Wall Bearing Withfront And Back 120 Or Moreribs Guard; Three No.Blades, Noise Level Should Be <= 75 Db, Including Fixing With Anchor Bolts, Making Connection Testing Etc. As Required. ( With Remote ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 95 Wall Mounting Type With Service Value 2.0 Cmm / W, Min. Air Delivery 71 Cmm 96 Providing & Fixing Ofbeestar Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallicblade Ceilingfanconforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing ( I.E. Isi Marking ) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope ) , Cotter Pin With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 97 1200 Mm Sweep Bee 1 Star Rated ( Service Value >=4.0 To < 4.5 ) 98 Providing & Fixing Ofof Double Ball Bearing, Copper Wounded Capacitor Startsingle Phase Metallicblade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core Copper Conductor , Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 99 300 Mm Sweep 100 Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wounddouble Ball Bearing900 / 1400 Rpm Single Phaseexhaustfan Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 101 300 Mm Sweep ( 900 / 1400 Rpm ) 102 380 Mm Sweep ( 900 / 1400 Rpm ) 103 Providing & Fixing Ofof Ventilating Fans Capacitor Start, Copper Wounded, Single Phase With Pvc Impeller, Abs Body, Automatic Openable Louver Shutter In Existing Opening Including Making Connection, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 104 150 Mm Sweep 105 250 Mm Sweep 106 P & F Of Wall Cowl With Bird Screen Suitable For Outside Wall Of Exhaust Fan Openingof Following Size And Made Out From 24 Swg Gi Sheet As Per Instructions Of Engineer In Chargeincluding Fixing With Suitable Fasteners Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 107 Suitable For 300 Mm Sweep Exhaust Fan 108 Suitable For 380 Mm Sweep Exhaust Fan 109 Providing & Fixing Of Ik08, Ip 66 Protected Led Street Light Luminaire On Existing Bracket / Pole. Fixture Made Of Powder Coated Single Piece Pressure Die Cast Aluminummaterial With Heat Dissipation Fins On Housing With Uv Stabilized Pc ( Uv Stablization Report Submitted For Uv Cover ) / Toughened Glass Coverand Secondary Lens On Each Led & Should Be Smd Type Of 3 To 5 Watt Each . The System Efficacy >=125 Lm / Wt And Potted Driver& Has A Unique Bis R Number Withinput Voltage Ac 120 To 270 V Ac With High Voltage Cutoff @>=300 V Ac And Auto Resetting Safety , Power Factor >0.95 Driverefficiency >85%, Thd ( I ) <10%Humidity 10% To 90% Rh Working Temp -5C To 45C .Driver Current <750Ma. The Luminaireshall Be Bis Certified And Trade Mark Certified. Life Expectancyequal Or More Than 50000 Burning Hrs With Minimum 70% Lumen Maintened , Cri >70 And Cct 5700K +355K. Surge Protection Shall Be Min = 4 Kv Internal And Min 10 Kv External Inside Driver Compartment. Driver Should Be Phase To Phase Protection Of 440 V For 4 Hrs.Manufactures Word Mark / Name Engraved / Embossing On Die Cast Housing To Allow Traceability / Authenticity. Fixture Shall Be As Per Is 10322 Complianced.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities Forled Fixtures. ( Lm79 / Lm80 ) Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 110 Led Street Light Fixture With Minimum Lumen Output 11225 Lm 111 Supply And Erection Ofgalvanized Iron Pole With Galvanizing Done In Single Dipping ( Average Coating Thickness Minimum 65 Microns ) Continuously Tapered Poles Having Octagonal / Circular Cross-Sections Designed To Withstand The Maximum Wind Speed As Per Is 875, The Pole Shaft Shall Be Made From Sheet Steel ( Ht Steel Conforming To Grade S355jo ) And Confirming To Bsen 10025 And Shall Be Continuously Tapered With Single Longitudinal Welding. There Shall Not Be Any Circumferential Welding. The Welding Of Pole Shaft Shall Be Done By Submerged Arc Welding ( Saw ) Process. Pole Shafts Shall Be Provided With The Rigid Flange Plate Of Suitable Thickness ( Fe 410 Conforming To Is 226 / Is 2062 ) With Provision For Fixing 4 No. Foundation Bolts, This Base Plate Shall Be Fillet Welded To The Pole Shaft At Two Locations I.E. From Inside And Outside.The Octagonal Poles Shall Have Lockable Door Of Approximate 500 Mm Length At The Elevation Of 500 Mm From The Base Plate With Bakelite Sheet Having 6A Sp Mcb And 16 Sqmm Stud Type Connector ( 4 Nos ) Inside The Pole At Door Opening For Cable Connection Of Following Length And Dimension As Per Table P-01 With Base Plate And Foundation Bolt On The Existing Cement Concrete Foundation.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 112 Poles With Octagonal Cross Section 113 7 Mtr. 114 Supply And Fixing Of Pole Oem Fabricated Hot Dipped Galvanised M.S. Overhang ( 48.3 X 3.25 Mm ) With Cap ( 400 X 88.9 / 114.3 X 3.25 Mm ) Over The Existing Poles. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 115 Single Arm Overhang 116 Providing And Laying Rcc Foundation For Octagonal / Conical Street Light Poles, High Mast Poles As Per Drawing Attach At Tablep-4With Following Procedure& All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 117 A ) Excavation Of Pit For Foundation Size Upto Required Depth From Ground Level 118 B ) Dressing Of Pit And Dry Stone Pitching 200 Mm Thick Including Supply Of Stones And Preparing Surface Complete. 119 C ) Providing And Laying In Position Cement Concrete Of M-10 Grade Of 75 Mm Thickness 120 D ) Reinforcement For R.C.C. Work With Tmt Bars Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete. 121 E ) Centring And Shuttering Including Strutting , Propping Etc. And Removal Of Form Work For Footing And Pedestal 122 F ) Providing & Fixing Of 2 No. Required Sizeplb Hdpe Pipe& Foundation Bolt With Template As Per Oem Recommendations. 123 G ) Providing And Layingreinforce Cement Concrete Of M-25 Grade In Footing And Pedestal Including Curing The Foundation For 7 Days. 124 H ) Providing And Fixing Nosing Angle 40 Mm X 40 Mm X 6Mm With 2 No. 100 Mm Long, 10 Mm Dia. Lugs On Each Face. 125 Pole Foundation For Octagonal Pole From 7 Mtr. To 9 Mtr. 126 Providing & Fixing Of Ik08ip65 Protected Top / Bottom Mounted Led Post Top Luminarie Made Of Single Piece Constructionpowder Coated Die Cast Alluminium Housing With Uv Stabalized Clear / Frosted Polycarbonate Diffuser Andaluminium Anodised With Sand Blast Reflector. The System Level Luminous Efficacy =100 Lumen / W. Smd Leds Is To Be Used, System Cri>70, Cct: 3000 / 4000 / 6500 K. The Integral Electronic Driver Must Be Potted & Has A Unique Bis R Number Must Be Potted & Has A Unique Bis R Number Constant Current And Internal / External Surge Protection Device Of Min. 4Kv ( L-N ) And Efficiency > 85%, Pf>0.9, Thd<10% And Input Voltage Range Of 140-270V Ac At 50Hz. System Life Of 50000 Burning Hours With 70% Of Initial Lumens Maintained . Driver Current <750Ma.Fixture Must Be In Compliance With Bis Standards And Trade Mark Certificate Complete In All Respect.Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities Forled Fixtures. ( Lm79 / Lm80 ) Certificate / Report With Liable Warranty Of Product / Accessories From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 127 Minimum Lumen Output 4500 Lm Post Top Luminarie 128 Providing & Fixing Of Street Light Bracket Made Out From Following Size Of " B " Class , Medium Class G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Heavy Duty Pole Clamp, Saddles Suitable Fastners Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 129 40 Mm Dia. 130 Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler Withhermeticallysealed Compressor, Non Cfc Refrigerent Suitable For Operation On 230V / 1Ph / 50Hz Ac Supply, Full Stainless Steel ( Ss304 ) Body ( 0.8 Mm Thick ) And Tank ( 0.5 Mm Thick ) , Stainless Steel Water Tray, Minimum Two Nosbrass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Requiredheight Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra ) Complete In All Respect Of The Following Capacity.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 131 Cooling Capacity 150 Ltr. / Hr. And Storage Capacity 150 Ltrs 132 Providing And Laying Non Pressure Np-3 Classr.C.C. Pipes Including Collars / Spigot Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Etc. As Required. ( Excavation Of Earth& Back Filling With Compaction Is To Be Paid Extra ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 133 200 Mm Dia. 134 Labour Charges For Excavating Trenches Of Required Width For Pipes Dressing Of Sides, Ramming Of Bottoms, Depth Up To 1.5 Mtr. Including Taking Out The Excavated Soil, And Then Returning The Soil As Required In Layers Not Exceeding 20Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 Mtr.: 135 All Kind Of Soils 136 Sitc Of Wall Type Following Zone ( Each Zoneaccessing Minimum 20 Units ( Detectors / Devices ) ) Conventional Type Microprocessor Based With Lcd Display En / Lpcb / Ul Listed / Approved Main Control Panel Fabricated From 16 Swg Crca Sheet Steel Sealed Maintenance Free ( Smf ) Batteries Of Min2x7ah Of 12 V Or As Required.Including The Cost Of All Accessories, Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 137 4 Zone 138 Sitcof En / Lpcb / Ul Listed / Approved Conventional Type Manual Call Point Resettable Complete With Glass, Hammer And Chain Etc.Including The Cost Of All Accessories Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 139 Sitc Of En / Lpcb / Ul Listed / Approved Conventional Type Hooter Cum Strobe Including The Cost Of All Accessories, Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 140 Supply & Fixing Of Water + Afff 6%Mechanical Foam Typefire Extinguisher ( Stored Pressure Type ) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 25 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 141 Capacity - 6 Ltrs. 142 Supply & Fixing Of Co2 Type Fire Extinguisher Conforming To Is:15683:2018, Charged With Co2 Gas ( Purity 99.7% Conforming To Is 15222 ) , Powder Coated Internal & External Surface Manganese Steel Isi Marked As Per Is 7285 Cylinder Body , Wheel Type Forged Brass Release Valve Isi Marked As Per Is 3224 With Inbuilt Safety Release Device ( ( Fusible Plug And Rupture Disc Type ) , 1.0 Mtr. Metal Wire Braided Hose Having Minimum Bursting Pressure Of 140 Kgf / Cm2, Horn With Metallic Thread Connection, Qr Code For Product Traceability, Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 143 Capacity 4.5 Kg. 144 Supply & Fixing Of Dry Powder Agent ( As Per Is 4308:2019 ) , Abc Typefire Extinguisher ( Stored Pressure Type ) Conforming To Is:15683:2018 , Powder Coated Internal & External Surface Deep Drawn Cylinder Body Of Mild Steel Cr2 Grade Conforming To Is: 513, Squeeze Grip Forged Brass Release Valve With Inbuilt Safety Release Device, Diaphragm Type, 0 To 28 Bar Range Pressure Gauge, 450 Mm Long Epdm Discharge Tube, Qr Code For Product Traceability Including Fixing On Wall With Suitable Anchor Fasteners As Required Of Following Capacity. Test Certificates Of All The Parameters Along With Hydro Test & Burst Test ( For Cylinder Body ) Certificatefrom Oem / External Nabl Accrediated Lab Is To Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 145 4 Kg 146 Supply , Installation, Testing And Comissioning Ofinverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit ( Idu ) , Out Door Unit ( Odu ) , Surface / Concealed Copper Refrigerant Piping With Insulation ( Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section ) Upto 3 Mtr ( Idu To Odu ) , Copper Power Cable Upto 3.5 Mtr ( Idu To Odu ) , R-32 / R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V + / - 10% With Low & High Voltage Cutoff And50 Hz , Single Phaseacsupply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 147 1.5 Tr Iseer Not Less Then 4.6 148 2.0 Tr Iseer Not Less Then 4.6 149 Providing & Fixing Of Is : 4985 - 2000 Class -4 ( 10 Kgf / Sqcm ) Upvc Drain Water Piping Withfittings ( Is:7834 & 10Kgf / Sqcm ) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wallwith Chasing & Plastering With 6 Mmthickclosedcellelastomeric Nitrile Rubberinsulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 150 25 Mm 151 Supply, Fixing And Testing Of Following Capacity Iso Certified Company Made Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V ( + / -5% ) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 Amp / 20 Amp Industrialplug Top Making Connection Etc Complete In All Respect.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 152 4 Kva 153 5 Kva 154 Making Hole In Stone Masonary / Rcc Wall / Rcc Slab With Core Cutter For Accomodating Refrigerant Pipe / Drain Pipe / Ms Pipe / Cables Etc Of Following Dia 155 50 Mm Dia Per Running Inch Length 156 Supply & Fixing Ms Powder Coated Stand Suitable For 1.0 / 1.5 / 2.0 Tr Outdoor Type Of Split Ac.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 157 Sitc Of Interconnecting Refrigerantcopper Pipe Forsplit / Ductable / Casseette Ac Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Markbrand Printing On Hard Tubes Should Be Present. Piping Between Each Set Of Indoor & Outdoor Units Of Different Sizesas Per Oem Requirement & Specifications Including Class "O" Nitrile Rubber Sleeves, Chase Cutting, Supports, Making Good The Same With Sand Cement Plaster Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 158 Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation ( Shielded ) Cables Voltage Grade 300 / 500 V As Per Bs / En 50288-7 In Existingsurface Or Recessed Pvc / Ms Conduit / Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Cables. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 159 Un Armoured 160 4 Core X 2.5 Sq.Mm 161 Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of 10 Ka Breaking Capacity ( B / C / D Tripping Characteristic As Per Type Of Load Andsite Requirement ) 4 Kv Impulse Withstand Voltage, Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Ofclass 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductor Line Load Reversibility , Ip 20 Contact Protection And Fitted Inexisting Distribution Board / Sheets, Minimum Electrical Operation 20, 000 Upto 20 A Rating And 10, 000 Upto 63 A, 5000 For 80 A & Above Ratingincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 162 Single Pole Mcb ( With B / C Curve Tripping Characteristics ) 163 0.5 A To 5 A Rating 164 6 A To 32 A Rating 165 Double Pole Mcb ( With B / C Curve Tripping Characteristics ) 166 50 / 63 A Rating 167 Triple Pole Mcb ( With D Curve Tripping Characteristics ) 168 6 A To 32 A Rating 169 50 / 63 A Rating 170 Four Pole Mcb ( With B / C Curve Tripping Characteristics ) 171 50 / 63 A Rating 172 40 A Rating 173 Providing & Fixing Of 240 / 415 V Residual Current Circuit Breaker ( Rccb ) Conforming To ( Is:12640-1 ) / Iec 61008 -1 , Rated 4 Kv Impulse Withstand Voltage Truly Current Operated And Shall Operate On Cbct Mechanisum, Provision For Pad Lock, Min. Operation 10, 000 Upto 63 A Rating And5000 For 100 Aratingand Minimum Phase Termination Capacity Of 35 Sq.Mm. Rigid Wire, Ip 20 Contact Protection With Existing Distribution Board / Sheetincluding Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 174 Two Pole 100 / 300Ma Sensitivity 175 40 A Rating 176 63 A Rating 177 Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Horizontal Type Double Door ( Metal / Glazed ) Distribution Board With Metal End Box Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3, Powder Painted Complete With Reversible Door ( For Double Door Db Only ) 100 Amp. Insulated Copper Bus Bar / Shorting Link , Copper Neutral Link, Copper Earth Link , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 178 Glazed Door ( Single Phase ) Ik-09 And Ip-43 With Metal End Box 179 12 Way ( 12+2 ) 180 Metal Door ( Three Phase ) Per Phase Isolation, Horizontal Ik-09 And Ip-43 With Metal End Box 181 4Way ( Incomer 8, Sub Incomer2+2+2 ) 182 6Way ( Incomer 8, Sub Incomer2+2+2 ) 183 8Way ( Incomer 8, Sub Incomer2+2+2 ) 184 12 Way ( Incomer 8, Sub Incomer2+2+2 ) 185 Providing & Fixing Of Recessed / Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provision Of Incomer Suitable For 3 / 4 Pole Mccb And Sp / Tp Mcb As Outgoing , Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mm Thick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powder Painted With Reversible Door ( For Double Door Db Only ) Complete With Insulated 160 ( Upto 160 A Incomer ) / 250 Amp. Copper Bus Bar, Neutral Bars With Shrouds, Earth Bar , Color Coded Interconnecting Wire Set Of Suitable Rating And Din Bar, Masking Sheet, Making Internal Db Terminations With Copper Lugs, Ferrules, Detachable Gland Plate, Including Making Connections, Testing Etc. As Required. Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Reports& All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 186 Double Door Ip-43 & Ik-09 With Provision Of Incomer Mccb 100 / 125 A Rating With Metal End Box 187 4 Way 188 6 Way 189 8 Way 190 12 Way 191 Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Arrmouredaluminiumcable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv Withh4- Grade Electrolyticaluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Round / Flat Strip Armouring Of Cables, Inner / Outer Sheath Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench / Cable Tray ( With Cable Tie ) Includingtesting Etc. As Required Of Following Size. Oem Must Have It"S Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810.For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 192 6.0 Sq. Mm 193 4 Core 194 10.0 Sq. Mm 195 4 Core 196 16.0 Sq. Mm 197 4 Core 198 35.0 Sq. Mm 199 3.5 Core 200 70.0 Sq. Mm 201 3.5 Core 202 95.0 Sq. Mm 203 3.5 Core 204 185.0 Sq. Mm 205 3.5 Core 206 Add Extra For Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Gradedirect In Ground Including Excavation Of Trench Of Size 75 Cm ( Depth ) X 35 Cm ( Width ) , With Procedure As Per Followingpoints:- ( A ) Make A River Sand Bed Of Height 125 Mm Along The Trench, ( B ) Lay The Cable In The Middle Of The Trench, ( C ) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable, ( D ) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thicknessand 225 Mm Widejust Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr. ) , ( E ) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, ( F ) Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 207 Add Extra For Laying Of One Number Additional Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Gradedirect In Ground In The Same Trench In One Tier Horizontal Formation Including Excavation Of Trench Of Size Additional 20 Cm In Width, With Procedure As Per Following Points :- ( A ) Make A River Sand Bed Of Height 125 Mm Along The Trench, ( B ) Lay Another Cable In Middle Of Trench In Such Manner That Spacing Between Another Cable Is 20 Cm., ( C ) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable. ( D ) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thicknessand 225 Mm Widejust Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr. ) , ( E ) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, ( F ) Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth. 208 Supplying And Making One End Termination With Nickel Plated Heavy Duty Brass Single Compression Gland ( As Per Is 12943-1990 ) ) Sibg Type Consisting Of Check Nut, Gland Body, Metal Washer ( 3 Nos. ) , Outer Seal Rubber Ring, Compression Nut, Heavy Duty Aluminium Lugs ( As Per Is 8309 -1993 ) Duly Crimped With Crimping Tool, Pvc Tape As Peris 8337-1976Offollowing Size Ofpvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 209 3.5 X 185.0 Sq.Mm 210 3.5 X 95.0 Sq.Mm 211 3.5 X 70.0 Sq.Mm 212 3.5 X 35.0 Sq.Mm 213 4 X 16.0 Sq.Mm 214 4 X 10.0 Sq.Mm 215 4 X 6.0 Sq.Mm 216 Supply, Fabricating & Installing Following Sizes Of Perforated Hot Dipped Galvanized Iron Cable Tray ( Galvanized Thickness Not Less Then 50 Microns ) With Perforation Not More Then 17.5% In Convenient Section Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Gi Suspenders Including Gi Bolts & Nuts , Fastners, Supports Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 217 150Mm X 50Mm X 1.6Mm 218 P / L Of Double Wall Corrugated Hdpe Pipe Confirming To Is : 16205 P-24, Stiffness Class750 N, Externally Corrugated And Having Smooth Surface Insidewith Hdpe Coupler, Elbow, Teeat Required Depth Below The Ground For Laying Cable Of Followingnominal Outer Dia.Mfr Test Reportfrom Nabl Accrediated Is To Be Submitted. ( Excavation Of Earth& Back Filling With Compaction Is To Be Paid Extra ) All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 219 50 Mm 220 110 Mm 221 Plate Earthing As Per Is:3043 Withcopper Earth Plate Of Purity >95% Of Size 600Mm X 600Mm X 3.0Mm By Embodying3 Mtr. Below The Ground Level With 20Mm Dia. G.I. "B" Class Watering Pipe , Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height250 To 300 Mm. And Embodying The Pipecomplete With Alternate Layers Salt And Coke / Charcoal, Testing Of Earth Resistance For Value Of 5 Ohms Or Lessas Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 222 Supplyandinstallationofhigh Tensile Low Carbon Steel Rod Molecularly Bonded With 99.9 % Copperthickness ( 250 Microns ) Andconfirming Toul 467, Is / Iec 62561-2Of Following Size And Length And As Per Point Mentioned ( A ) , ( B ) , [ C ) , ( D ) , ( E ) Below :- 223 ( A ) Bore A Hole Of Dia. 100 Mm Of Required Length, Place The Rod In The Centre Of Hole 224 ( B ) Filled With Anti Corrosiveconductivecompounds With The Permanent Sealings At Both The Ends, Cpri / Erdatested With Rms Capacity Of Minimum 30 Ka For Withstanding 1 Second .To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Labfor Lowresistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Contentas Per Referance Of Is 3043-1987, Ieee 80-2013 ( Clause 14.5D ) , Ieee 837 & Ier 1956 With Latest Amendemnts 225 © Connect The Rod With Copper Strip / Conductor / Wire With Suitable Clamp Made From Tinned Copper And Ss 304 Bolt 226 ( D ) Place Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height250 To 300 Mm. 227 ( D ) Testing Of Earth Resistance For Value Of 5 Ohms Or Lessas Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. 228 ( E ) Test Certificatesfor Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 229 25 Mm Thick And 3 Mtr. Long 230 Supply & Laying Following Size Earth Stripin Horizontal Or Vertical Run In Surface By Means Of Earth Strip Dmc Insulatorincluding Riveting / Soldering / Welding, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass ( For Cu Strip ) / Gi ( For Gi Strip ) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 231 25Mm X 3Mm G.I. ( Hot Dipped ) Strip 232 50Mm X 6Mm G.I. ( Hot Dipped ) Strip 233 40Mm X 6Mm Copper Strip 234 Supply & Laying Following Size" B " Class , G.I. Pipe Confirming To Is : 1239 P - 1 ( 2004 ) With Accessories Like Bend, Socket Etc.For Laying Earth Conductor / Strip / Cable In Ground / Surface / Recess As Required.All As Per Pre Approved By Engineer In Charge. ( Earth Excavation Will Be Paid Extra ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annex Ure "A" Attached With This Bsr . 235 50 Mm Dia. 236 65 Mm Dia. 237 80 Mm Dia. 238 100 Mm Dia. 239 150 Mm Dia. 240 Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Purity Purity >95%Thimble Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 241 8 Swg G.I. ( Hot Dipped ) Wire 242 Supply, Drawing And Testing Of 4 Pair, 23 Awg Solid Bare Copper Wire Insulated With Pvc, Utp ( Unshielded Twisted Pair ) , Category 6, Class E, 100 Ohm Impedance, Indoor Cable As Per Latest Ammendments Of Ansi / Tia / Eia-568 , The Copper Conductors Should Be Balanced Twisted In Pairs, Seperated By A Cross-Member Fluted Pair Divider & Protected Bypvc Jacket. Certified Performance In A 4-Connector Configuration Upto 100 Mtrs Channel Requirements & Transmission Frequencies Up To 250 Mhz. In Existing Ms / Pvc Conduits / Casing Capping Including Making Connections To Information Outlets And Patch Panels With Jack &Ferruling At Both Ends For Identification With Necessary Tools For Punching, Stripping, Crimping And Testing Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 243 Supply And Installation Of Unsheilded / 360 Degree Sheilded Information Outlets Made Of High Impact Plastic Body With Abs, Fr Grade Halogen Free Material With Provision For Protection Against Dust In Jack, Suitable For Cat 6 / 6A Application Complying To Latest Ammendments, According. To Cat. 6 / 6A Channel, It Should Support Channel As Well As Components Requirements Of Cat.6 / 6A Standards At Frequencies Of Up To 250 To 500 Mhz. Cat 6 / 6A Unshielded / Shielded Jack Should Be Suitable To Terminate 4 Pair, 23 / 24 Awg Solid / Stranded Wire Diameters, Using 100 Ohm Unshielded / Shielded Balance Twisted Pair Cable, The Jack Should Have Tooless / Impact Termination On Reliable Copper Tin Plated Insulation Displacement Contact, With Easy Lock Mechanism, It Supports Iec 60603-7-4 And Complied With Ansi / Tia / Eia 568 C.2 Standard. Jack Should Be Rj11, Rj12 & Rj45 Compatible. Should Support Ethernet 1.2 Gb / S Atm, Digital Video And Broadband / Baseband Analog Video, Voice Over Internet Protocal ( Voip ) Specifications In Existing Modular / Ms Boxes Along With Necessory Connections As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 244 Cat 6, Un-Sheilded Information Outlet 245 Supply & Fixing Of Square Faceplate For Flush / Surface Mount Information Outlets Single / Dual Or Quad Aperture , Material Should Bepc+Abs Body, Suitable For Rj45 Unshielded / Shielded Connection Modules. Should Match With I. O. Oem. Dimensions Should Be 86Mm X 86Mm As Required Complete In All Respect.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 246 Single Aperture 247 Supply, Installation, Testing And Comissioning Of Rack Mounted 19" 1U, Cat6 24 Port Loaded, 1.5-1.6 Mm Crs Chasis, Powder Coated, Sheet Steel, Made Of Plastic ( Abs ) , Modular Patch Panelswith Rear Cable Management System And Mounting Hardware To Mount The Patch Panel. Should Have Port Identification Numbers Printed / Engraved On Front Of The Panel. Etc. As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 248 Modular Patch Panel Loaded With Cat -6 I / O 249 Supply , Installation And Testing Of 4 Pair, 100 Ohm Impedance, Cat 6 / 6A / Class E / Ea Patch Cords Should Be Constructed Of Minimum 23 / 24 Awg, Stranded Bare Copper Cable With Frpvc / Lszh Jacket, With An Enhanced Performance By Factory Moulded Rj45 Connectors With Strain Relief Boots As Per Ansi / Tia / Eia 568-C.2 Suitable For Cat 6 / 6A Application Complying To Latest Ammendments Category 6 / 6A Standards, According. To Tia568c.2, Iso / Iec 11801, En 50173, Iec 60603-7-51, En 60603-7, Ieee 802.3An Minimum Requirement For 1G Base-T To 10G Base-T Performance. Patch Cords Shall Be Straight Thru Cable Compatible With Both T568-A And T568-B Wiring Schemes, Should Support Ieee 802.3Af / Ieee 802.3At For Poe Applications, Minimum 750 To 1000 Mating Cycles In Plug Contacts For Long Durability, Should Support Ethernet 10Gbase-T, 1.2 Gb / S Atm, Token Ring 4 / 16, Digital Video And Broadband / Baseband Analog Video, Voice Over Internet Protocal ( Voip ) .All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 250 Cat 6, U / Utp ( Unscreened / Un-Sheilded Twisted Pair ) Patch Cord 251 1 Mtr 252 2 Mtr 253 Supply & Installation Of Ip-20 & Ik-08 , Ul Listedwall Mounted Double Section Communication Enclosure ( Rack ) Made From Powder Coated ( 60 To 80 Micron ) Crca Sheet, Front Sturdy Sheet Steel Frame Folded From One Piece And Welded With Minimum 5Mm Toughened Glass Door, Vertical Mounting Rail 1.6 Mm With "U"Marking , With All Round Protective Channel On The Door Aperture, Lock Integrated On Front Door, Top And Bottom Cover With Cable Entry Provision With Gland Plates, Integrated Side Walls, 2 Pair Of 19" Angles With Wall Mounting Provision On Wall. Accessories Like: 1 No Of 19" 1U Horizontal Cable Manager, 1 No Of 90 Cfm 230V Ac Fan With 1 Mts Long Cable, Mounting Hardware , 1 No Of 19" 1U, Mountable Socket Strips With 5 Nos Of 5A Universal Sockets With 2 Mts Long Power Chord For Supplying Power To Switches, Fans Etc Along With Earth Continuity Kit, Indicator, Moulded Power Supply Cable. Fixing On Wall With Suitable Anchor Fastneretc As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 254 15 U Rack With Width 600 Mm & Depth 400 Mm + 100 Mm 255 Supply & Installation Of Ip-20 & Ik-08 , Ul Listed Communication Enclosure ( Rack ) Made From Powder Coated ( 60 To 80 Micron ) Crca Sheet, Vertical Mounting Rail 1.6 Mm With "U"Marking, Front Sturdy Sheet Steel Frame Folded From One Piece And Welded With 5Mm Toughened Glass Door, With All Round Protective Channel On The Door Aperture, Lock Integrated On Front Door, Top And Bottom Cover With Cable Entry Provision With Gland Plates, Integrated Side Walls, Set Of 75 Mm Height 4 Castors, 2 Of Which Have Brakes, Accessories Like: 5 Nos Of 19" 1U Horizontal Cable Manager, 2 Nos Of Vertical Cable Managers, 1 No. Keyboard Tray, 4 Nos Of 90 Cfm 230V Ac Fan With 1 Mts Long Cable, Mounting Hardware , 2 No Of 19" 1U, Mountable Socket Strips With 6 Nos Of 5A Universal Sockets With 2 Mts Long Power Chord For Supplying Power To Switches, Fans Etc Along With Earth Continuity Kit, Indicator, Moulded Power Supply Cable Complete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 256 27 U Rack With Width 600 Mm &Depth 800 Mm 257 Supply , Installation, Testing And Comissioning Ofmanaged Layer-2 Intelligent 10 / 100 Ethernet Switch Providing 24 X 10 / 100 / 1000 Mbps Giga Ethernet Ports / With Min 2 Sfp Giga Ports ( Provision For Fiber Giga Connectivity ) With Related Lan Base Software Including Making Connections Etc As Required.All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 258 Providing & Laying Xlpe Insulated Three Core Armouredaluminiumcable For Working Voltage 11 K.V. ( E ) Confirming Is :7098 P - 2Withh4- Grade Electrolyticaluminium Conductor Confirming To Is: 8130 Class-2 Of Purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound Followed By Helically Wrapped Copper Tape, Round / Flat Strip Armouring Of Cables , Inner / Outer Sheath Pvc Type St-2 Confirming To Is:5831In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench / Cable Tray Includingtesting Etc. As Required Of Following Size. Oem Must Have It"S Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810 All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 259 3 Core 185.0 Sq.Mm 260 Add Extra For Laying Of One Number Xlpe Power Cable Of 11 / 33 Kv ( Earthed ) Voltage Gradedirect In Ground Including Excavation Of Trench Of Size 120 Cm ( Depth ) X 35 Cm ( Width ) , With Procedure As Per Followingpoints:- ( A ) Make A River Sand Bed Of Height 125 Mm Along The Trench, ( B ) Lay The Cable In The Middle Of The Trench, ( C ) Provide River Sand Bed Of Height 125 Mm On Top Of The Cable. ( D ) Lay The Protective Common Burnt Clay F.P.S. Bricks Of Class Designation 75 / Sand Stone Slabs Of 50 Mm Thicknessand 225 Mm Wide Just Above The Sand Bed Vertically Across The Cable ( Approx. 9 No. Bricks Per Mtr. ) , ( E ) Backfill The Excavated Soil Leaving 300 Mm From The Ground Level, ( F ) Lay The Cable Warning Tape And Again Back-Fill The Remaining Portion Of The Trench Upto The Ground Level And Compacting The Earth 261 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kitsuitable For11 Kv / 33 Kv ( Earthed ) Cable With Required Components, Prepration Of Cable Ends. Type Test Report Should Be As Per Is13573:2011 Which Covered All Sequence For Table 2 For Termination Kit And Table 3 For Streightthrough Joint Inclusive Thermal & Dynamic Short Circuit Test, Humidity Test, Soil Fog Test. Crosslinking Shall Be Done Out Side Factory With E- Beam / Peroxide Technology. Extrusion Process Shall Be In House Oem Within Same Vicinity. Includingtesting Etc. As Required Of Following Sizes. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 262 11 Kv End Termination Kit Indoor Type 263 3 Core 120 / 150 / 185 Sq.Mm 264 11 Kv End Termination Kit Outdoor Type 265 3 Core 120 / 150 / 185 Sq.Mm 266 Providing & Fixing Of Iso Certified Company Made On Load Change Over Switch, Front Handle Operated, Four Pole 415 V As Per Pwd Specificationfor Electrical Works Conforming To Is / Lec 60947-3 : 1999 Including Connections , Testing Etc. As Required .In The Following Rating.Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted .All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 267 Open Execution Type 268 200 A 269 Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalisedcubical Panel As Specifications Andother Parameters Requiredas Per Point ( A ) , ( B ) , ( C ) , ( D ) , ( E ) , ( F ) , ( G ) , ( H ) As Below:- 270 ( A ) Thickness Of Crca Sheet Shallbe 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Withoutdetachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided 271 ( B ) Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel.The Panel Having Pe Foam / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness , Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment / Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. 272 [ C ) Interconnection Between Bus Bar And Switchgears / Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires ( Up To 63 Amp ) And By Solid Bus Bar ( >63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only.All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgearis To Be Paid Extra ) 273 ( D ) Wiring Between Components Within Switchgear And Incoming / Outgoing Cableshall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. 274 ( E ) All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ ( No Wire Splitting Or Tee Connections ) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. 275 ( F ) Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismcchannel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) 276 ( G ) Tests: The Insulation Resistance ( With 1000 V Megger ) And High Voltage Power Frequency Test ( By Applying A Voltage Of 2.5Kv For One Minute ) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. 277 ( H ) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only ( Cpri Test Certificates To Be Submitted ) All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 278 Supplying And Fixing Of Aluminium ( Iec 60105 Iso 209-1, 2 ) / Copper ( Iec 60028 ) Bus Bar By Means Of Smc / Dmc Type Insulatorwith Standard Short Circuit Withstand Capacity, High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 279 Electrolytic Grade Aluminium Bus Bar 6010 Grade 280 Providing & Fixing Of Is: 13875 & Iec :61326 Confirming Led Digital Type ( Up To 500 ) V Range Volt Meter / Direct- Ammeter / Ct Oertated Ammeter / Frequency Meter / Kwh Meter / Multi Function Meter / Power Analyzer Of Class 1 Accuracyas Per Is : 1248 Of Size 96Mm X 96 Mm Including Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 281 Threephase Amp+Hz+Pf+Kw+Kva+Kvar+T.Energy+Thd-I, Thd-V & Run Hrs 282 Providing & Fixing Of Bis Approvedcurrent Transformeras Per Pwd Specification For Electrical Works , Isi Marked As Peris 2705-1992 / Conforming To Iec 60044-1, With Secondary Terminalof Ct Shall Be Brought Out Suitable To A Terminal Block Which Shall Be Easier Accessible For Testing And Terminal Connection , With All Necessary Support In Existing Panel Including Connection Etc. As Requiredcurrent Transformer Ring Type Tape Wound / Resin Cast Wound As Per Is 16227 With, Accuracy Cl, Ct Ratio And Burden As Specified. Isf<=5, Cu Cross Section Of Secondary Wire 1.5Sqmm ( Minimum ) , Including All Necessary Support In Existing Panel Including Connection Etc. As Required . All As Per Pre Approved By Engineer In Charge.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 283 Ring Type Tape Wound Ct 284 C T Class 1, Ratio 200 / 5 To 300 / 5, Burden 10 Va 285 C T Class 1, Ratio 400 / 5 To 1200 / 5, Burden 15 Va 286 Providing & Fixing Ofcam Operated Rotary ( Auto / Manual ) Switches On Existing Panel With 2 Way And Off Position Using High Grade Engineering Materialto International Standards With Cam Assemblyinsulation Of Glass Filled Polyamide With High Tracking Index. For Reliable And Stable Electrical And Mechanical Endurance Double Butt Contacts With Silver Bi-Metal On Copper Should Provided . Contact Assembly Is Of Operating Temp Range -25 Degree C To 55 Degree C, Frequency Upto 10 Khz. Switch Life Under Std. Op. Conditions Shall Be Mechanically Minimum 50000 Operations @300 Cycles / Hour And Electrically 10, 000 Operations At 100% Rated Duty For 100 Cycles / Hour Including Making Connection Etc.As Required . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 287 32 Amp 288 Providing & Fixing Of110 / 220 V, Unibody Led Indicatinglamp Iec 60947With Integral Circuit, Ip 65 Above Panel &Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min.29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Ofbrass ( Tin Plated ) , Impulsedielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdcincluding Connection Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 289 Red / Yellow / Green Colour 290 Blue / White Colour 291 Providing & Fixing Of Electricalinsulating Rubber Matts As Per Pwd Specification For Electrical Works, Isi Marked Confirming To Is: 15652 / 2006With One Sideanti Skid Abberation Marks And Pasting The Mat With Synthetic Rubber Adhesive As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 292 11 Kv, Class B 2.5 Mm Thick With Proof Voltage 22 Kv Ac ( Rms ) And Break Down Voltage45 Kv Ac ( Rms ) 293 Providing & Fixing Of Self Healing Ip20 Mpp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 Or Iec : 60831-1& 2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz, Operating Loss Less Than 0.30 Watt Per Kvar. Min Over Current Capacity 1.8 Times Rated Current & Peak Inrush Current Min. 300 Times Of Rated Current, Llife Expectancy Greater Than 100000Hrs ( Temp Class - 25 D ) In 440 V / 480 V Capacitor And For 525 V Should Life Expectancy Minimum 1, 65, 000 Hrs ( Temp Class - 25 D ) Including Making Connections, Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 294 Heavy Dutythree Phase 525V, 50 Hzcylindrical Typecapacitor ( Bank ) 295 Providing & Fixing Of Ip54 Microprocessor Based 3 Ct’S For All 3 Phasesensing Compensationpower Factor Correction Relay Size 139Mm X 139 Mm, Operating Voltage 415 / 440 V, Iec / En 61000-6- ( 2&4 ) Having 3 Ct Sensing, Sensitivity Up To 50 Milli Amp Secondary Current , Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Havedigit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Communication Interface With Rs 485, Indication Of Switching On Units, Auto / Manual Status, And Shall Have Over Load Protection, No Volt Release , Having Multi Parameter Like Kw, Kva, Kvar, Rms Value, Step Switching Time 2 Sec To 1800 Sec. Lead & Lag Parameters, Metering Facility And3 No. Class- 0.5 Cast Resinct ( Refer Ct Specs In This Chapter ) For Sensing The Relay Including Making Coonection With 1.5 Sq.Mm Copper Wire Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 296 12 To 14 Stage 297 Providing & Fixing Ofac Operated Heavy Duty 230 / 440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is / Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 298 3 Pole Power Contactorswith Following Ac 3 Rating 299 40 Amp 300 Providing & Fixing Of440 Volt 3 Pole Capacitor ( Ac 6 B ) Duty Contactor With 3 No. Early Make And Post Break Auxiliary Contacts In Series With Quick Discharge Damping Resistors / Reactors To Limit The Inrush Current As Per Pwd Specification For Electrical Works, Is / Iec 60947-4-1 : 2000, Insulation Voltage 1000V, Impulse Withstand Voltage 8 Kv, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. Suitable For Following Capacity Capacitor Bank.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 301 Up To 6 Kvar 302 10 Kvar 303 20.0 Kvar 304 Providing & Fixing Of Mechanical / Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 305 One Day & Week Reserve ( Digital Type ) 306 Sitc Of3 / 4Pole Current Limiting Moulded Case Circuit Breaker ( Mccb ) Made Of Flame Retardent & Heat Resistant Materialhaving Following Current Rating, Short Circuitbreaking Capacityat 440 / 415 V, 50 Hz; O / L & S / C Settings , Conforming To Is / Iec 60947 P -2 :2003 With Frontface And Centralised Adjustable, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push ( Test ) To Trip, Trip Time Less Then 10 Ms Under S / C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage690 V.Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connectionsetc. As Required.Oem Shall Have Submitnabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure "A" Attached With This Bsr 307 3 Pole Mccb With Thermal Magnetic Release 308 160 Amp , 25 Ka, Adjustable O / L & Adjustable S / C Setting, 309 4 Pole Mccb With Thermal Magnetic Release 310 Up To 100 Amp , 25 Ka, Adjustable O / L & Adjustable S / C Setting, 311 125 Amp , 25 Ka, Adjustable O / L & Adjustable S / C Setting, 312 160 Amp , 25 Ka, Adjustable O / L & Adjustable S / C Setting, 313 200 Amp , 25 Ka, Adjustable O / L & Adjustable S / C Setting, 314 250 Amp , 35 Ka, Adjustable O / L & Adjustable S / C Setting, 315 400 Amp , 35 Ka, Adjustable O / L & Adjustable S / C Setting, 316 S I T C Of Star Ratedaluminium Wound Distribution Transformerof Following Rating 11 / 0.433Kv Delta-Star Connected, Vector Group Dyn 11, Onan Cooled & As Per Bee Star - 1 & Bis Approved As Per Is 2026- 1977 & Lossesas Defined As Per 2014 ( Fourth Revision ) Level-1 . Including Standardaccessories Like Conservator, Silica Gel Breather, Radiator, Fins, Ht Cable Box & Lt Cable Boxes, Temperature Rise In Winding / Oil 35-40 Degree C Upto 200 Kva & 40-45 Degree C For Above 200 Kva, Isi Marked Drain Valve, Dial Type Temperature Gauge, First Filling Of Transformer Oil As Per Is :335-1953, Epoxy Based Paint, Including Carrying Of Pre-Commission Testing & Charging Of Transformer Complete In All Respect . 317 The Transformer Shall Be Subjected To Routine Factory Tests ( As Per Is:2026 And Is:1180 ) Including Testing From Ctlof Discombefore Charging Of Transformer & Complete Installaion Must Be Certified From Electrical Inspectorate Office As Per Indian Electricity Rule, ( Ctl Testing Charges And Electrical Inspection Charges Shall Be Reimbursed By The Department To The Contractor ) . All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 318 250 Kva With Off -Ltc ( +5% To - 10% @ 2.5% ) 319 Sitc Of 11Kv 630 Amps 21Ka For 3 Sec. Sf6 Insulated, Outdoor Duty ( Ip54 ) , Extensible / Non Extensible Typering Main Unit ( Rmu ) Manually Operated In Combination Ofvcb Modules Andload Break Switch Consisting Of Copper Busbar In Sf6 Insulated 304 ( Non-Ferrite Non-Magnetic Grade ) Stainless Steel Enclosure Of Thickness 2.5Mm With Manometer.The Hv Switchgear And Control Gear Should Be Confirming To Iec-62271-100, Iec-62271-200-2003 & Iec-60694-1996. The Rmu Should Be Internal Arc Tested For 21Ka For 1Second With Iac-Afl Classification For Gas Tank. Vacum Interrupter Of Vcb Should Be Rmu Manufacturer’S Own Make.Each Feeder Of Rmu Should Have Voltage Presence Indicator. . And Compring Offollowings:- 1 No. Microprocessor Based Self Powered Numerical Relay With Over Current / Earth Fault & Short Circuit Protection With Each Vcb Feeder. - 3 Nos. Protection Ct Shall Be Of Burden 2.5Va, Ratio 50 / 1A, Class Of Accuracy Class 5P10for O / C And E / F Protection For Each Vcb.- 1 No. Manometer For Each Tank, - 1 Nos. Fault Passage Indicator, -Right Angle Boots For All The Feeder Modulesall The Type Test Certificates As Per Iec From Third Partynabl / Cpri / Erda Accrediated Lab To Be Submitted. ( Cost Of Rcc Foundation / Steel Structure To Be Paid Extra ) All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr 320 Non Extensible 3 Way Rmu With 1 No. Vcb & 2 No. Load Break Switch 321 Sitc Of Ht Metering Cubical Panel As Approved By Discoms Fabricated Out Of 18 Swg Crca Sheet Steel In Two Compartment & Ms Angle Of Size 60Mmx 6Mm Having Provision For Following: ( I ) Provision For Fixing Trivector / Import - Export Meter ( To Be Supplied By Discoms ) ( Ii ) Provision For Fixing Of Combined Ct Pt Set With Copper Strip For Connection ( To Be Supplied By Discoms ) , ( Iii ) Test Terminal Block, ( Iv ) 6Mm Thick Bakelite Sheet On All Sides, ( V ) 3 / 6 Corex 1.5 / 2.5 Sq.Mm Copper Cable For Interconnections, Etc. As Required. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 322 Sitc Of Radiator Cooled And Turbo Charged Silent Dg Set ( As Per Latest Cpcb Emissionnorms ) Havingspecifications As Per A, B, C, D, E, F, G, H & I 323 A ) 1500 Rpm Diesel Engine Conforming To Bs:649 / 5514 Of Suitable Bhp ( Up To 82.5 Kva 6 Cylinder Or Below Required, 125 Kva & Above Ratings 6 Cylinder Or Aboverequired ) Capable Of Taking 10% Over Loading For One Hour After 12 Hours Of Continuous Operation., Dry Exhaust Mainfold With Hospital Grade Silencer And Catalytic Convertor ( Isolated From Main Dg Chamber ) , Up To 3 M Exhaust Piping ( With Lrb Insulation & Alum. Cladding ) As Required . 324 B ) Ac Brush Less Spdp Alternator Conform To Bs 5000 ( Part 99 ) Or Is / Iec 60034-1. . Alternator Shall Be Self Regulated With Standard Alternator Protection ( Over Voltage , Over Speed & Under Voltage, Under Speed Warning & Shutdown ) .Engine & Alternator Mounted On A Common Base Frame & Coupled Through A Flexible Coupling Or Close Coupled 325 C ) Cpcb / Arai Approved Standard Canopy With Weatherproof, Powdercoated Accoustic Enclosure For Dg Set For Sound Attenuation Fabricated From 1.6 Mm Crca Sheet Steel ( Structure ) With Sidewall Fabricated From 1.6 Mm Crca Sheet & Filled With Glasswool ( 96Kg / M3 ) / Foam. As Per Is8183 The Doors Of 28 / 40 / 50 / 85Mm Thick As Perrating And Fabricated From 1.6Mm Crca Sheet Packed With Accoustic Material, All Doors / Opening Are Sealed With Neoprene / Epdngaskets. The Dg Set Has Inbuilt / External In Fuel Tank To Run 6 To 8 Hrs As Per Oem Standard, With Protection And Tripping Of Dg Set Against Temperature Of More Than 50 Degree Centigrade. 326 D ) Electronic / Mechanical Governor, Manual & Electric Start , Batteries With Battry Charger, Engine Instruments Panel, Avm Pads All Controls For Operation Of Dg Set Are From Outside The Enclosure With Dg Control Panel Having Microprocessor Based Genset Monitoring Like Running Hour, Rpm, Low Lube Oil Tripping & Control System, Panel Mounted Mccb / Acb Of Suitable Rating, Ammeter, Voltmeter, Pf Meter, Frequency Meter, Kwh Meter, Digital Fuel Display Meter, Ind.Lamps Etc. Mounted Inside Enclosure , Visible And Accessible From Outside. The Enclosure Should Be Suitable For Following Capacity Dg Sets And Alternator. Noise Level Shall Be Less Than 75 Db At A Distance Of 1 Mtrs. Duly Certified By Authorised Agency Etc. Complete In All Respect Of Following Capacity : 327 E ) ( I ) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 40Mm And Not Less Then 20Mm Pu Foam Upto Rating 100 Kva. ( Ii ) .Accoustic Glass Wool Wall Thickness Should Not Be Less Then 65Mm And Not Less Then 50Mm Pu Foam Upto Rating 250 Kva. ( Iii ) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 100Mm Forrating Above 250 Kva. 328 F ) First Filling Of The Fuel Tank Shall Be Done By Contractor And The Prevailing Fuel Cost At That Time Shall Be Reimbursed To The Contactor By Department. 329 G ) Servicing Contract Of Dg Set From Oem"S Authorised Service Dealer As Per Oem Guidelines During The Dlp Period Shall Be Done By Contractor Including All Consumables, Actual Charges Shall Be Reimbursed To The Contractor By End User Department. 330 H ) Manufacturer / Oem Must Have Its Authorized Service Dealer In Rajasthan. Which Can Provide Service Within 6 Hours Of Compalint Registration. 331 I ) Dg Set Will Be Offered For Inspection And Testing At Manufacturer"S Works In Presence Of Departmental Engineers. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 332 40 Kva At 0.8 Pf 415V 50Hz 3-? 333 Sitc Of Plc Based Auto Main Failure ( Amf ) Panel Fabricated From Crca Sheet Steel 2 Mmthick , Powder Coated Finish , Engine Start & Stopcommands, Control Relays , Ammeter & Voltmeterwith Selector Switches, Control & 2 Nos 4 Pole Power Contactors With 2 No. Of Required Size 4 Pole Mccb, Timers, Electronic Hooter , Visual & Alarm Indication For Faults, Ups, Operator Interface Panel Complete In All Respect Suitable For Following Capacity Dg Sets: Appropriate Test Certificate / Report Of Product / Accessories From Oem / Panel Manufecturer Shall Be Submitted. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 334 20 To 40 Kva 335 Supply & Fabrication Steel Structure With Ms Channel / Angle / Joist / Ismb / Sheet Etc. Including Welding, Rivetting, Cutting, Nut & Bolt , One Coat Of Primer & Two Coat Of Enamel Paint Etc. As Requiredcomplete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 336 Providing And Fixing Welded Mesh / Expanded Metal Mesh 25 Mmx 25 Mm X 3Mm In Frame Work, Flat Iron Beading 20X3mm Including Top Cross Laps Inside And Out Sides Welding, Iron Bolts, Crews, Clips Etc. Including Two Coat Of Red Oxide And Two Coat Of Enamel Paint Or More Requiredcomplete With Frame Work With 50 X 50 X 6Mm Angle Iron Post 30 Cm In Ground Embeded In Cement Concrete 1:3:6 ( 30X30x45cm ) At Corner And Every Three Mtr Including Painting With One Coat Of Primer And Two Coat Of Enamel Paint Work Will Be Done As Per Direction Of Engineer Incharge Of Sizecomplete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 337 Earth Work In Excavation / By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5M In Width As Well As 10 Sum On Plan ) Including Disposal Of Excavated Earth, Lead Upto 50 M And Lift Upto 1.5 M, Disposed Earth To Be Levelled And Neatly Dressed: 338 Random Rubble Masonry With Hard Stone In Foundation And Plinth Including Levelling Up With Cement Concrete 1:6:12 ( 1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size ) Upto Plinth Level With Cement Mortar 1:6 ( 1-Cement : 6-Sand ) . 339 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level 340 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) 341 Plaster On New Surface On Wall In Cement Sand Mortar 1:4 Including Racking Of Joints Etc. Complete Fine Finish : 342 20Mm Thick 343 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shadetogive An Even Shade Including All Scaffolding: 344 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 345 Sitc Of Single Stage, Water Cooled, High Speed ( 2880 Rpm ) , Horizontal, Centrifugal, Openwell Submersible Pumps Set Pre Filled With Coolent Water And Fitted With Mechanical Seal - T / C Vs T / C, Thrust Bearing Shall Be Ofcarbon + S.S.The Stator Body Of Single Phase Pumpshall Be Of Ss And Rest Of All Shall Be Of Cast Iron. All Casting Parts Should Be Cathod Electro Deposition ( Ced ) Coated And Other Construction Material Should Be Confirming To Is : 14220: 2018 . The Overall Performance Of Pump Shall Confirm To Bee Energy Efficiency Level Of 3 Star. Valid Bee Certificate From Oem Must Be Submitted For The Same. Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011, Including Making Connection Etc As Required Complete In All Respect. Oem Shall Have Submitnabl / Cpri / Erda Accrediatedlab Type Test Certificate Before Execution. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 346 5.0 Hp, 3-Ø, ( 14 -28 ) Mtr, ( 995-500 ) Lpm 347 Sitc Of Contactoroem Fabricated Dol / Star-Delta Starter Panel With Switchgear Selection As Per Type-2 Cordinatiom Chart Andmade Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Offpush Buttons, Ammeter, Voltmeter, Indicating Lamps Etc.Suitable For Following Rating Motors Complete In All Respect. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products / Work, Refer Annexure "A" Attached With This Bsr . 348 For Three Phase Submersible / Mono Block Pump 349 3.0 Hp To 5.0 Hp ( Dol Starter ) 350 Part "B" Non Bsr Items Based On Market Rate 351 Sitc Ofro Water System With Filtration Stage = Particulate Filter-Membrane Life Enhancer Filter - Sediment Filter - Pre Carbon Filter -Ro Membrane Filter - Post Carbon Filter, Input Power Rating - 230 V Ac , 50 Hz, Percentage Of Rejection Tds - 90% Or Better Having Following Features ( A ) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator ( B ) .Spin Welded Ro Membrane Housing To Prevent Tempering ( C ) . Push Fit Components For Leak Proof Performance ( D ) . Fully Automatic Operation With Auto Start And Auto Off ( E ) . Ss Construction For Corrosion Free Lifespan ( F ) . Equally Suitable For Water From All Bore Wells, , Overhead Storage Tanks, Water Tankers And Even Municipal Taps ( G ) Ro Membrane Flushing - Auto Flush @ Every Start , Every Stop And Every One Hourof Working For One Minute. Complete In All Respect With Following Capacity. Approved Make:Eureka Forbes, Kent, Au Smith, Ion Exchange, Pentair. 352 Purification Capacity- 50 Lph, Duty Cycle 270-500 Liters / Day, 353 Sitc Of Dome Ip Ir Cctv Cameras: Network H.265 2Mp ( Full Hd ) Megapixel High Frame Rate Mini Dome Camera With Built In Microphone:2Mp Ir Dome Camera With Metal Body And Built In Mic: 1 / 2.8" Progressive Scan Cmos; Resolution: 1920 × 1080@30Fps Or Better; Colour: 0.01 Lux @ ( F1.2, Agc On ) Or Better, H.265+ Compression Or Better; 120 Db True Wdr Or Better; Fixed 2.8 / 4Mm Lens; Built In Mic; 3D Dnr; 40M Ir Range Or Better, Triple Streams; Blc, 3D Dnr, Hlc; Line Crossing Detection, Intrusion Detection; Scene Change Detection; Face Detection; Anti-Flicker, Heartbeat, Mirror, Password Protection, Privacy Mask, Watermark, Ip Address Filter; Onvif ( Profile S, Profile G ) , Isapi; Built-In Micro Sd / Sdhc / Sdxc Slot, Up To 128 Gb Or Better; Operating Condition: -30 °C To +60 °C; Ip67; 12Dc & Poe; Certificate Of Compliance: Ul, Ce / Fcc, Bis, Rohsapproved Make: Samsung / Hikvision / Panasonic / Infinova / Cp Plus / Dahua / Honeywell 354 Sitc Of Ip Ir Cctv Bullet Outdoor Camera: Network H.265 2Mp ( Full Hd ) Megapixel High Frame Rate Ir Bullet Camera ( Outdoor ) With Metal Body, 2Mp Full Frame Low Light Ir Bullet Camera: 1 / 2.5" Progressive Scan Cmos; Resolution: 1920 × 1080 Or Better; Color: 0.002 Lux @ ( F1.2, Agc On ) Or Better; Slow Shutter; Fixed 3.6 Mm Lens; Triple Streams; 3D Dnr; 120Db Wdr; 50M Ir Range Or Better; Line Crossing Detection, Intrusion Detection, Object Removal Detection, Unattended Baggage Detection, Scene Change Detection; Face Detection; Anti-Flicker, Heartbeat, Mirror, Password Protection, Privacy Mask, Watermark, Ip Address Filter; Onvif ( Profile S, Profile G ) , Isapi; Roi; Support Micro Sd / Sdhc / Sdxc Card ( 128G ) , Local Storage And Nas ( Nfs, Smb / Cifs ) , Anr; Operating Condition: -30 °C To +60 °C; Ip67; 12Dc & Poe; Metal Body; Built In Junction Box For Cable Management; Certificate Of Compliance: Ul, Ce / Fcc, Bis / Rohs Approved Make: Samsung / Hikvision / Panasonic / Infinova / Cp Plus / Dahua / Honeywell 355 Sitc Of Raid 5 Supported 32Ch Nvr With Upto 48 Tb Hdd Support 32Ch Ip Inputs; Dual Os For Redundancy; Support Anr Technology;320Mbps Incoming Bandwidth, Supports Up To 12Mp Full Channel Recording; Support H.265 Compression; 16Ch Syncronised Playback @1080P; Support Raid 5; N+1 Hot Spare System; Support 3Rd Party Cameras; 4K Output; Minimum 8 Sata Hdd Slots; Each Slot Should Suppport Upto 6Tb Hdd; E-Sata Interface; Dual Gigabit Self Adaptive Ethernet Interface; Serial Interace; Usb Interface; Alarm In / Out;Dual Power Supply ( All Cameras And Storage-Nvr Should Be Of Same Make For The Smooth Functioning Of The System ) . Certificate Of Compliance: Ul, Ce / Fcc, Bisapproved Make: Samsung / Hikvision / Panasonic / Infinova / Cp Plus / Dahua / Honeywell 356 Sitc Of 3.5" 6Tb Surveillance Hard Disk ( Makes: Seagate / Wd / Toshiba ) 357 Sitc Of Workstation Latest Intel® I5 Processor, With 17" Led Monitor Screen Intel Chipset Motherboard, 08 Gb Ram, 1 Tb Sata Hdd At 7200 Rpm, With 4Gb Gpu Type Higher End Graphic Card For H.265 Compression Technique With Dual Display Ports / Dvi / Hdmi Port, Giga Lan Card, Wireless Keyboard, Wireless Optical Mouse With Original License Windows Software Of Approved Makes: Lenovo, Hp, Dell. 358 Sitc Of 55"" Flat Smart Screen Hd Profesional Led With Remote Control And Wall Mount Unit / Floor Stand Complete With Making Connections Etc Of Approved Makes: Lg, Samsung, Panasonic. 359 Sitc Of 5 Kva 1 Phase Input, 1 Phase Output Advance Dsp Controlled Ups With Igbt Based Rectifier, Lcd Display, Double Conversion / Digital Signal Processing Ups, With Isolationtransformer, With 26Ahx X 16 Nos Smf Batteries For Min 30 Min Back Up, With Ms Rack For Barreries And Required Cabling For Incoming & Outgoing Connection Of Approved Makes: Numeric, Eaton, Emerson, Apc. 360 Supply, Installation, Testing & Commissioning Of Managed Layer-2 Intelligent Ethernet Poe Switches Providing 08 X 10 / 100 / 1000 Fast Ethernet Poe Ports- 67W Or Better And 2 Dual Purpose Uplink Ports ( Provision For Copper / Fiber Giga Connectivity ) All Switches & Related Fiber Modules Should Be Of Same Make & Category For Seamless Integration With Each Other Of Approved Makes: Cisco Catalyst Series Or Equivalent In Avaya, Juniper ) 361 P & F Of Early Streamer Emission Type Lightning Arrester On Gi Mast With Air Terminal Configured As Spheroid Which Is Comprised Ofseparate Electrically Isolated 4 Panels Surrounding An Earthed Central Finial, The Terminal Shall Be Tested By Cpri For Impulse Current Of 45 Ka ( 8 / 20 Sec ) With 5 Positive & 5 Negative Impulse, The Arrester Having Following Protection Radius At Level 1 Approved Makes :Lpi ( Australia ) , Lpsfr ( France ) , Sudafix ( Uk ) , Ef ( Switzerland ) , Abb 362 30 - 48 Mtr. 363 S & Laying Of P.V.C. / Xlpe Insulated & P.V.C. Sheathed Down Conductor Of 70 Sq.Mm Single Core Insulated Flexible Copper Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv Withelectrolytic Gradecopper Made Of Copper Rodsconfirming To Is 613-1964, Of Purity >99.7 %, Inner / Outer Sheath Confirming To Is:5831 With Accessories As Required. Oem Must Have It"S Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810Approved Makes: Polycab, Rr, Finolex.
|