Expression Of Interest For Unit Rate For Providing, Making And Supplying Furniture And Furnishing Items, Including Wall Panelling, False Ceiling, Laboratory Furniture, Doors, Windows And Cupboards, Making And Supplying And Installation Of Aluminum Structured Modular Partition System, Kitchen Basket With Runners, Furniture And Furnishing Items, Including Aluminum Composite Wall Panelling, False Ceiling, And Cupboards Etc Of Any Cost At Any Places / Building Of Naus Main Centre & All The Sub Centers- Providing, Supplying & Installation Of Snap Fit Modular Wall Paneling Using 8 Mm Thick Prelaminated Cement Fiber Board: - For Providing, Supplying & Installation Of Snap Fit Modular Wall Paneling System Using 8 Mm Thick Prelaminated Cement Fiber Board Level Should Be Marked On The Wall Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then €Œgyptech €Œor Equivalent And Approved Brand By Nau Authority. Cold Rolled Formed 0.55 Mm Thick G.I. Perimeter Channel Having Size Of 30 Mm X 27 Mm X 20 Will Be Fixed To The Perimeter Of The Wall With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. €Œgyptech €Œor Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick €Œw†Shape Having Size Of 26 Mm X 50 Mm X 26 Mm X 80 Mm Ceiling Sections Should Be Then Inserted Vertically And Horizontally To Form A Grid Size Of 600 Mm X 600 Mm Or As Per Design And Fixed To Perimeter Channel Using Screws. Required Size Of Packing ( Solid Pvc / Marine Ply ) Should Be Placed Behind Ceiling Section And Fixed To Ceiling Section And Wall Or Partition.. Aluminum Section Having Size Of 24 Mm X 9 Mm Extruded From 6063 Grade Aluminum Alloy Should Be Fixed To Ceiling Section Using Screws And Greed Should Be Formed 600 Mm X 600 Mm Or Required Size As Per Design Layout. 8 Mm Thick €Œbison†Or Equalant Approved Brand By Nau Authority Wood Textured Prelaminated Cement Fiber Board Should Be Place In Grid And Fixed Using Snap Fit Powder Coated Or Anodized Aluminum Clip Having Size Of 14 Mm X 13 Mm . If Site Condition And Space Constrain Issue The Aluminum Base Channel Having Size Of 24 Mm X 9 Mm Extruded From 6063 Grade Aluminum Alloy Can Be Fixed To Directly On Wall Or Partition To Form A Grid And Then 8Mm Thick €Œbison†Or Equalant Approved Brand By Nau Authority Wood Textured Prelaminated Cement Fiber Board Should Be Place In Grid And Fixed Using Snap Fit Powder Coated Or Anodized Aluminum Clip Having Size Of 14 Mm X 13 Mm. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge., Providing, Supplying & Installation Of 12 Mm Thick X 120Mm Prelaminated Soiled Core Wall Paneling :- For Providing, Supplying & Installation Of 12 Mm Thick X 120Mm Prelaminated Soiled Core Wall Paneling The Cladding Panels Should Be E-3 Clad Or Equalant Brand Having Thickness Of 12 Mm X 120 Mm Wide Prelaminated And Seamless Joining System . The Wall Or Surface To Be Clad Line Level And Design Pattern Should Be Marked. 50 Mm X 15 / 20 Mm Thick Solid Pvc Strips Having Density Of 550 / 600 M3should Fixed To Wall Using Screws Making Grid Of 600 Mm X 600 Mm .The Then Cladding Panels Should Be Fixe To Grid Structure Using Double Sided Glue Tap And Dow Corning Or Equalant Brand Silicone Adhesive. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge, Providing, Supplying & Installation €Œvox†€Œ Pare†Brand Wall Paneling & Ceiling: - For Providing And Fixing €Œvox†€Œ Pare†Brand Thermal Printed Section Ceiling And Wall Paneling Level Should Be Marked On The Wall, Ceiling Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick G.I. Perimeter Channel Having Size Of 30 Mm X 27 Mm X 20 Will Be Fixed The Perimeter Of The Wall With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. Line Should Be Marked At Roof Or Slab At 1200 Mm Intervals In Both The Directions To Form A 1200 X 1200 Grid For Hanger Placement. The Intersection Point Of These Lines Will Be The Hanger Fixing Point. Cold Rolled Formed 0.55 Mm Thick Having Size Of 18Mm X 18 Mm G.I.Angle Longer By 6€ Than The Distance Between The Level Mark And Roof Or Slab Should Be Used As Hanger One End Of The Angle Should Be Fixed To The Roof Or Slab And Other To The Intermediate Channel Using Self Drilling Screws. €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.9 Mm Thick €Œc†Shape Having Size Of 15 Mm X 45 Mm X 15 Mm Intermediate Channels Should Be Suspended At 1200Mm To 1500 Mm Centers In Line And Level. The Channels Should Be Overlapped By 6€ To Increase The Length. . €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick €Œw†Shape Having Size Of 26 Mm X 50 Mm X 26 Mm X 80 Mm Ceiling Sections Should Be Then Attached To The Intermediate Channel At 450 Mm To 600 Mm Centre Perpendicularly With The Help Of Self Drilling Screws. Ceiling Sections Or Should Be Overlapped By 6€ To Increase Length Of Ceiling Section And Screw.3Mm Thick X 340 Mm €Œvox†€Œ Pare†Brand Thermal Printed Section Ceiling And Wall Paneling Or Equivalent And Approved Brand By Nau Authority Tongue And Groove Joining System Should Be Used For The False Ceiling And Wall Paneling. The Plastic Section Will Be Then Positioned Underside Of The Frame Keeping Longitudinal Edges Of The Panel Across To The Ceiling Sections. The Plastic Section Will Be Screw Fixed To The Frame By Using Self Drilling And Tapping Screws. Then Another Panel Will Be Sided To Panel. All Opened End Will Be Covered With Same Brand Of Panel Used €Œj†Shape 19 Mm X 40 Or Connector Section Having Size Of 76 Mm X 12 Mm. Cynoacrylate Adhesive Of &Quot;Thanga Bond S-302&Quot; / Or Equivalent And Approved Brand By Nau Authority Should Be Used For Joining Panel And Capping Section. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge., Providing, Supplying & Installation Of Snap Fit Modular Wall Paneling Using 12Mm Thick Prelaminated Wood Chip Base Particle Board : - For Providing, Supplying & Installation Of Snap Fit Modular Wall Paneling System Using 12Mm Thick Prelaminated Wood Chip Base Particle Board Level Should Be Marked On The Wall Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick G.I. Perimeter Channel Having Size Of 30 Mm X 27 Mm X 20 Will Be Fixed To The Perimeter Of The Wall With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. €Œgyptech €Œor Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick €Œw†Shape Having Size Of 26 Mm X 50 Mm X 26 Mm X 80 Mm Ceiling Sections Should Be Then Inserted Vertically And Horizontally To Form A Grid Size Of 600 Mm X 600 Mm Or As Per Design And Fixed To Perimeter Channel Using Screws. Required Size Of Packing ( Solid Pvc / Marine Ply ) Should Be Placed Behind Ceiling Section And Fixed To Ceiling Section And Wall Or Partition.. Aluminum Section Having Size Of 24 Mm X 9 Mm Extruded From 6063 Grade Aluminum Alloy Should Be Fixed To Ceiling Section Using Screws And Greed Should Be Formed 600 Mm X 600 Mm Or Required Size As Per Design Layout. 12 Mm Thick €Œaction Tessa†Or Equalant Approved Brand By Nau Authority Prelaminated Wood Chip Base Particle Board Should Be Place In Grid And Fixed Using Snap Fit Powder Coated Or Anodized Aluminum Clip Having Size Of 14 Mm X 13 Mm . If Site Condition And Space Constrain Issue The Aluminum Base Channel Having Size Of 24 Mm X 9 Mm Extruded From 6063 Grade Aluminum Alloy Can Be Fixed To Directly On Wall Or Partition To Form A Grid And Then 12 Mm Thick €Œaction Tessa†Or Equalant Approved Brand By Nau Authority Prelaminated Wood Chip Base Particle Board Should Be Place In Grid And Fixed Using Snap Fit Powder Coated Or Anodized Aluminum Clip Having Size Of 14 Mm X 13 Mm. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge, Providing, Supplying & Installation Of Cavity Modular Wall Paneling Using 12Mm Thick Prelaminated Wood Chip Base Particle Board- For Providing, Supplying & Installation Of Cavity Modular Wall Paneling System Using 12Mm Thick Prelaminated Wood Chip Base Particle Board Level Should Be Marked On The Wall Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then €Œiqbx €Œor Equivalent And Approved Brand By Nau Authority Extruded Aluminum Section Having Size Of 44 Mm X 25 Mm Will Be Fixed To Wall Vertically With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. €Œiqubx†Or Equivalent And Approved Brand By Nau Authority Aluminum Extruded Section Having Size Of 12 Mm X 53 Mm Should Be Then Inserted Using Screws Horizontally To Form A Grid Size Of 600 Mm X 600 Mm Or As Per Design. Required Size Of Packing ( Solid Pvc / Marine Ply ) Should Be Placed Behind Main. Aluminum Hook Section Having Size Of 22Mm X 5 Mm Extruded From 6063 Grade Aluminum Alloy Should Be Fixed Required Size ( 600 Mm X 600Mm / As Per Design ) 12 Mm Thick €Œaction Tessa†Or Equalant Approved Brand By Nau Authority Prelaminated Wood Chip Base Particle Board Using Screws. Prelaminated Wood Chip Base Particle Board Should Be Place In Grid. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge., Providing, Supplying & Installation Of 9 Mm / 10Mm Thick X 250 Mm Membrane Coated Stone Plastic Composite Section Wall Paneling & Ceiling: - For Providing And Fixing 9 Mm Thick Membrane Coated Stone Plastic Composite Section Ceiling And Wall Paneling Level Should Be Marked On The Wall, Ceiling Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick G.I. Perimeter Channel Having Size Of 30 Mm X 27 Mm X 20 Will Be Fixed The Perimeter Of The Wall With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. Line Should Be Marked At Roof Or Slab At 1200 Mm Intervals In Both The Directions To Form A 1200 X 1200 Grid For Hanger Placement. The Intersection Point Of These Lines Will Be The Hanger Fixing Point. Cold Rolled Formed 0.55 Mm Thick Having Size Of 18Mm X 18 Mm G.I.Angle Longer By 6€ Than The Distance Between The Level Mark And Roof Or Slab Should Be Used As Hanger One End Of The Angle Should Be Fixed To The Roof Or Slab And Other To The Intermediate Channel Using Self Drilling Screws. €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.9 Mm Thick €Œc†Shape Having Size Of 15 Mm X 45 Mm X 15 Mm Intermediate Channels Should Be Suspended At 1200Mm To 1500 Mm Centers In Line And Level. The Channels Should Be Overlapped By 6€ To Increase The Length. . €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.55 Mm Thick €Œw†Shape Having Size Of 26 Mm X 50 Mm X 26 Mm X 80 Mm Ceiling Sections Should Be Then Attached To The Intermediate Channel At 450 Mm To 600 Mm Centre Perpendicularly With The Help Of Self Drilling Screws. Ceiling Sections Or Should Be Overlapped By 6€ To Increase Length Of Ceiling Section And Screw. 9Mm / 10 Mm Thick Membrane Coated 300 Mm Wide Iso 9001 Certified €Œpolywood†Make Or Equivalent And Approved Brand By Nau Authority Membrane Coated Designer Series Multy Chambered Hollow Plastic Section Having Minimum Wall Thickness 0.2 Mm +- 0.015 X 300 / 250 Mm Wide And Tongue And Groove Joining System Should Be Used For The False Ceiling And Wall Paneling. The Plastic Section Will Be Then Positioned Underside Of The Frame Keeping Longitudinal Edges Of The Panel Across To The Ceiling Sections. The Plastic Section Will Be Screw Fixed To The Frame By Using Self Drilling And Tapping Screws. Then Another Panel Will Be Sided To Panel. All Opened End Will Be Covered With Same Brand Of Panel Used €Œu†Shape 9 Mm X 28 Pvc Section Or €Œl†Shape Pvc Section Having Size Of 25 Mm X 25 Mm. Vertical Wall Panel And Ceiling Panel Should Be Decorated At Joing Point 35 X 35Mm Double Side Cornice Section Or 25 Mm X30 Mm Single Cornice Section . To Extend The Length Of 6 Mm Thick Pvc Ceiling Section €Œh†Shape Pvc Section Having Size Of 56Mm X 11 Mm Should Be Used. Cynoacrylate Adhesive Of &Quot;Thanga Bond S-302&Quot; / Or Equivalent And Approved Brand By Nau Authority Sho, Providing Fixing Cement Fiber Board / Calcium Silicate ( Plain ) Wall Paneling: -.For Providing And Fixing Wall Paneling System Level Should Be Marked On The Wall As Per The Drawing, And Fix Approved Brand €Œgyptech†Or Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Center To Center. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel / Ceiling Section. 10 Mm Thick Plain Calcium Silicate / Cement Fiber Board’S / Cement Bonded Particle Board Should Be Screw Fixed To The Frame With Under Head Cutter. If Required Recessing Should Be Done Of Size 40Mm X 1.5Mm On Board If Boards Square Edged. The Boards Should Be Fixed To The Ceiling Sections Using Self-Drilling Csk Screws Of 7G X 25Mm @ 200Mm Intervals In The Same Direction To The Framing So That Board Should Have A Continuous Support. Extra Ceiling Section Should Be Fixed Wherever Required To Support The Boards. A Gap Of 2 To 3 Mm Should Be Provided Between The Boards. The Csk Screws Should Be Fixed From The Edge Least1.5 Times The Thickness Of Board ( Centre Of The Screw ) And 40Mm From The Corners At An Interval Of 200 Mm. The Joints Between The Boards Are Staggered In Brick Pattern If Permitted By Architect For Better Strength; Otherwise Fix It Straight Line To Have Uniform Groove Finish. Board Joints Should Be Finished With Jointing Compound And Fiber Tape To Get Joint Less Finish. If Required Water Based Wood Primer Should Be Applied On Entire Surface Before Applying Putty Or Paint. Two Coat Of Approved Shade Distemper Should Be Applied To Ceiling Work And Same Will Be Paid Extra As Approved Rates. Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge, Providing Fixing Cement Fiber Board / Calcium Silicate ( Designer ) Wall Paneling: -.For Providing And Fixing Wall Paneling System Level Should Be Marked On The Wall As Per The Drawing, And Fix Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Center To Center. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel / Ceiling Section. 10Mm Thick Designer Calcium Silicate / Cement Fiber Board’S / Cement Bonded Particle Board Should Be Screw Fixed To The Frame With Under Head Cutter. If Required Recessing Should Be Done Of Size 40Mm X 1.5Mm On Board If Boards Square Edged. The Boards Should Be Fixed To The Ceiling Sections Using Self-Drilling Csk Screws Of 7G X 25Mm @ 200Mm Intervals In The Same Direction To The Framing So That Board Should Have A Continuous Support. Extra Ceiling Section Should Be Fixed Wherever Required To Support The Boards. A Gap Of 2 To 3 Mm Should Be Provided Between The Boards. The Csk Screws Should Be Fixed From The Edge Least1.5 Times The Thickness Of Board ( Centre Of The Screw ) And 40Mm From The Corners At An Interval Of 200 Mm. The Joints Between The Boards Are Staggered In Brick Pattern If Permitted By Architect For Better Strength; Otherwise Fix It Straight Line To Have Uniform Groove Finish. Board Joints Should Be Finished With Jointing Compound And Fiber Tape To Get Joint Less Finish. If Required Water Based Wood Primer Should Be Applied On Entire Surface Before Applying Putty Or Paint. Two Coat Of Approved Shade Distemper Should Be Applied To Ceiling Work And Same Will Be Paid Extra As Approved Rates. Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing Fixing 12.5 Mm Non M.R Board Counseled Ceiling: -For Providing And Fixing Counseled Ceiling System Level Should Be Marked On The Wall / Partition As Per The Drawing, And Fix Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall / Partition With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Line Mark Should Be Done At 1220 Mm Intervals In Both The Directions To Form A 1220 X 1220 Grid. At The Intersection Point Of These Lines, Drill Hole Of 13Mm Diameter Using Hammer Drill Machine And Insert Fastener Of 12 Dia. X 38 Mm With One Leg Of 1.8 Mm Thick Soffit Cleat Having Web 25 Mm And Flange 27 Mm & 25 Mm Attached To It, And Tight The Fastener Fully. Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed G.I. Angle Of Having Size 25 X 10 Mm Should Be Cut And One End Of The Angle Should Be Fixed To The Soffit Cleat And Other To The Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick Intermediate Channel Having Both Flanges 15 Mm & Web 45 Mm Using 6Mm Diameter, 12Mm Long Nut And Bolt. Intermediate Channels Should Be Suspended At 1220 Mm Centers In Line And Level. For Long Rooms, Overlap The Intermediate Channels By 150Mm Or More To Increase The Length And Bolt Them With 6 X 12 Mm Blots. Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Fixed To The Intermediate Channel At 305 Mm Centre In Perpendicular Direction To It With The Help Of Connecting Clips Or Screws. Overlapping Of The Ceiling Sections Should Be Minimum By 150Mm Wherever Required To Increase The Length Of Ceiling Sections. Openings For Light Fittings / Ac Grills Etc Should Be Formed By Using Perimeter Channel / Section All Around The Opening. 12.5Mm Thick 12.5 Mm Non M.R Board 1220Mm X 2440Mm / 3050Mm Should Be Used For The False Ceiling Application. The Recessing Should Be Done Of Size 40Mm X 1.5Mm On Board If Boards Square Edged. The Boards Should Be Fixed To The Ceiling Sections Using Self-Drilling Csk Screws Of 7G X 25Mm @ 200Mm Intervals In The Same Direction To The Framing So That Board Will Have A Continuous Support. Extra Ceiling Section Should Be Fixed Wherever Required To Support The Boards. A Gap Of 2 To 3 Mm Should Be Provided Between The Boards. The Csk Screws Should Be Fixed From The Edge Least1.5 Times The Thickness Of Board ( Centre Of The Screw ) And 40Mm From The Corners At An Interval Of 200 Mm. The Joints Between The Boards Are Staggered In Brick Pattern If Permitted By Architect For Better Strength; Otherwise Fix It Straight Line To Have Uniform Groove Finish. Board Joints Should Be Finished With Jointing Compound And Fiber Tape To Get Joint Less Fini, Providing And Fixing Exposed Grid Ceiling With Cement Fiber Board Designer Tiles:-Exposed Grid Ceiling System Should Be Comprises Of0.4 Mm Thick Pre-Coated Steel €Œl†Shaped Angle Of Size 24 X 24 Mm, Fixed To The Brick Wall / Partition At The Perimeter Of The Ceiling By Nylon Sleeves And Wood Screws At 450 Mm Centers. Main &Quot;T&Quot; With Pre-Coated Steel At The Bottom, And H Notches At 300 Mm Centers, Interlocking Notches At Both Ends, Of Size 24 X 38 X 3000 Mm Is Suspended From The Soffit At 1200 Mm Centers With The Help Of Metal Rowel Plug, Soffit Cleat And A Level Clip With 4 Mm Dia. G.I. Wire. Cross &Quot;T&Quot; Of Size 24 X 38 X 1200 Mm With Bottom Pre-Coated Steel And H Notch In The Centre And Interlocking Notches At Both The Ends, Is To Be Inserted Fixed To The Main &Quot;T&Quot; At 600 Mm Centers To Form A Grid Of 600X1200 Mm. Another Cross T Of Size 24 X 38 X 600 Mm With Inter Locking Notches At Both Ends Is Inserted Fixed To The Centre Notch Of Above Cross T To Form A Grid Of Size 600 X 600 Mm. Above Style Grid System And 4 Mm Thick Designer Cement Fiber Board Of €Œhi-Chem†/ / €Decosil†/ Equalant Brand Approved By Nau Authority Ceiling Board Hiving Size Of 595 X 595 Mm Are Then Laid On To The Grid Accordingly. All Work Should Be Carried Out And Good Shape And Manner & In True Line & Level, As Directed By Engineer In Charge., Providing And Fixing Exposed Grid Ceiling With Glass Reinforced Gypsum Designer Ceiling Tiles For Acoustical Purpose €Œgypsonic†Or Equivalent And Approved Brand By Nau Authority:-Exposed Grid Ceiling System Should Be Comprises Of0.4 Mm Thick Pre-Coated Steel €Œl†Shaped Angle Of Size 24 X 24 Mm, Fixed To The Brick Wall / Partition At The Perimeter Of The Ceiling By Nylon Sleeves And Wood Screws At 450 Mm Centers. Main &Quot;T&Quot; With Pre-Coated Steel At The Bottom, And H Notches At 300 Mm Centers, Interlocking Notches At Both Ends, Of Size 24 X 38 X 3600 Mm Is Suspended From The Soffit At 1200 Mm Centers With The Help Of Metal Rowel Plug, Soffit Cleat And A Level Clip With 4 Mm Dia. G.I. Wire. Cross &Quot;T&Quot; Of Size 24 X 38 X 1200 Mm With Bottom Pre-Coated Steel And H Notch In The Centre And Interlocking Notches At Both The Ends, Is To Be Inserted Fixed To The Main &Quot;T&Quot; At 600 Mm Centers To Form A Grid Of 600X1200 Mm. Another Cross T Of Size 24 X 38 X 600 Mm With Inter Locking Notches At Both Ends Is Inserted Fixed To The Centre Notch Of Above Cross T To Form A Grid Of Size 600 X 600 Mm. Above Style Grid System And 10-12 Mm Thick €Œgypsonic†Or Glass Reinforced Gypsum Designer Ceiling Tiles Having Non Combustible Class €Œoâ€, Flame Spared Class €˜1€™, Nrc Value 0.60 / 0.75, Stc Value 0.35, K-Value 0.45W / Mk Property Of Approved Brand Ceiling Board Hiving Size Of 595 X 595 Mm Are Then Laid On To The Grid Accordingly. All Work Should Be Carried Out And Good Shape And Manner & In True Line & Level, As Directed By Engineer In Charge., Providing Fixing And Supplying 5 Mm Thick Prelaminated Solid Pvc Wall Paneling :- For Providing Fixing And Supplying 5 Mm Thick Prelaminated Solid Pvc Wall Paneling The Prelaminated Panel Should Be 5 Mm ( + / - 0.25Mm ) Thick Having Size Of 1220 Mm X 2400 Mm Manufactured By Iso 9000-2015 Company Rajshree / Giza Or Equivalent And Approved Brand By Nau Authority Stuck Inner Frame Of 50 Mm Wide Strip Of 12 Mm ( + / - 0.25Mm ) Thick Pvc Sheet Of Density 600Kg / Cubic Meter Manufactured By Iso 9000-2015 Company Mica / Giza Or Equivalent And Approved Brand By Nau Authority .The Strip Should Have In Their Center A Groove Of 6 Mm By Width And 1 Mm In Depth For Sinking The Head Of Screw Screws Used For Fixing The Pvc Strip To The Wall Vertically At An Equal Distance Of 250 Mm Between Two Pvc Strips. The Pvc Strip Shall Be Fixed To The Wall Using 65 Mm Long Anti Corrosive Self Drilling Through The Groove In The Strip By Using Pvc Fasteners. The Distance Between Two Screws Shell Not Be More Than 300 Mm .A Groove Of 2 Mm Left At The Joint Of Two Panels For Ascetic Looks. The Exact Size Of The Panel And Correspondingly Of Grid May Be Vary Depending On The Size Of The Wall. Optionally A Strip Of 5 Mm ( + / - 0.25Mm ) Thick Pvc Sheet Of Width 75 Mm Feathered At The Edge Of Shall Be Stuck At The Place Where Two Panels Are Joined Using Solvent Cement. All Work Should Be Complete As Directed By Engineer In Charge, Providing, Supplying & Installation Of 5 Mm Thick Solid Pvc Prelaminated Counseled Ceiling: - For Providing And Fixing 5 Mm Thick Solid Pvc Prelaminated Thick Counseled Ceiling Level Should Be Marked On The Wall, Ceiling Or Partition As Per The Drawing Leaving Scope For Panel Thickness And Then Cold Rolled Formed €Œgyptech†Or Equivalent And Approved Brand By Nau Authority 0.55 Mm Thick G.I. Perimeter Channel Gyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority Having Size Of 30 Mm X 27 Mm X 20 Will Be Fixed The Perimeter Of The Wall With Nylon Sleeves And Wood Screws At 600Mm Centers At The Required Level. 20 Mm Wide 5 Mm ( + / - 0.25Mm ) Thick Manufactured By Iso 9000-2015 Company Mica / Giza / Or Equivalent And Approved Brand By Nau Authority Having Size Should Be Screw Fixed To Perimeter Channel. Line Should Be Marked At Roof Or Slab At 1200 Mm Intervals In Both The Directions To Form A 1200 X 1200 Grid For Hanger Placement. The Intersection Point Of These Lines Will Be The Hanger Fixing Point. Cold Rolled Formed €Œgyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority 0.55 Mm Thick Having Size Of 18Mm X 18 Mm G.I.Angle Longer By 6€ Than The Distance Between The Level Mark And Roof Or Slab Should Be Used As Hanger One End Of The Angle Should Be Fixed To The Roof Or Slab And Other To The Intermediate Channel Using Self Drilling Screws. Cold Rolled Formed Gyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority 0.9 Mm Thick €Œc†Shape Having Size Of 15 Mm X 45 Mm X 15 Mm Intermediate Channels Should Be Suspended At 1200Mm To 1500 Mm Centers In Line And Level. The Channels Should Be Overlapped By 6€ To Increase The Length. Cold Rolled Formed 0.55 Mm Thick Gyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority W†Shape Having Size Of 26 Mm X 50 Mm X 26 Mm X 80 Mm Ceiling Sections Should Be Then Attached To The Intermediate Channel At 450 Mm To 600 Mm Centre Perpendicularly With The Help Of Self Drilling Screws. Ceiling Sections Or Should Be Overlapped By 6€ To Increase Length Of Ceiling Section And Screw. 50 Mm Wide 5 Mm ( + / - 0.25Mm ) Thick Manufactured By Iso 9000-2015 Company Rajshree / Giza / Or Equivalent And Approved Brand By Nau Authority Should Be Screw Fixed To Ceiling Channel. 5 Mm ( + / - 0.25Mm ) Thick Having Density 600Kgs / Cubic Meter Prelaminated Solid Pvc Sheet Manufactured By Iso 9000-2015 Company Rajshree / Giza / Or Equivalent And Approved Brand By Nau Authority Should Be Used For Ceiling Panel. The Pvc Sheet L Will Be Then Positioned Underside Of The Frame Keeping Longitudinal Edges Of The Pvc Sheet Across To The Ceiling Sections Using Cement Solvent Adhesive. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge., Providing Fixing And Supplying 3 Mm Thick High Density Decorative Solid Pvc Wall Paneling:- For Providing Fixing And Supplying 3 Mm Thick High Density Decorative Solid Pvc Wall Paneling The Decorative Panel Should Be 3 Mm ( + / - 0.15Mm ) Thick , Density Of 2000 / Cubic Meter Having Size Of 1220 Mm X 2400 Mm Manufactured By Iso 9000-2015 Company Sky Decore / Giza / Equalant Approved Brand By Nau Authority Stuck Inner Frame Of 50 Mm Wide Strip Of 5 Mm ( + / - 0.25Mm ) Thick Pvc Sheet Of Density 600Kg / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority .The Strip Should Have In Their Center A Groove Of 6 Mm By Width And 1 Mm In Depth For Sinking The Head Of Screw Screws Used For Fixing The Pvc Strip To The Wall Vertically At An Equal Distance Of 250 Mm Between Two Pvc Strips. The Pvc Strip Shall Be Fixed To The Wall Using 65 Mm Long M.S. Self Drilling Through The Groove In The Strip By Using Pvc Fasteners. The Distance Between Two Screws Shell Not Be More Than 200 Mm .A Groove Of 2 Mm Left At The Joint Of Two Panels For Ascetic Looks. The Exact Size Of The Panel And Correspondingly Of Grid May Be Vary Depending On The Size Of The Wall. Optionally A Strip Of 5 Mm ( + / - 0.25Mm ) Thick Pvc Sheet Of Width 75 Mm Feathered At The Edge Of Shall Be Stuck At The Place Where Two Panels Are Joined Using Solvent Cement. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge, Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Premium Shade And Exterior Grade Wall Paneling :- For Providing And Fixing 3 Mm Thick Aluminum Composite Panel Premium Shade And Exterior Grade Wall Paneling System For Structure Preparation Option -1 Level Should Be Marked On The Wall As Per The Drawing, And Fix Cold Rolled Form €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Cold Rolled Form Ceiling Sections €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Centre To Centre. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel / Ceiling Section.Option-2 15 Mm Thick 0.5 Mm Density Solid Pvc Panel Strip Having Size Of 50Mm X Required Length Or Width Should Be Fixed To Wall Using Nylon Sleeve And Self Drilling Screws To Form Structure Grid 600Mmx 600Mm. 3Mm Thick Aluminum Composite Panel Premium Shade And Exterior Grade €Œalex €Œ / €Flexi Bond†/ Equalant Brand Approved By Nau Authority Brand Should Be Fixed To Above Framing Structure Using 3M Brand Self Adhesive Double Gum Tape And Daw Corning Brand Silicon As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Plain In Color And Exterior Grade Wall Paneling :- For Providing And Fixing 3 Mm Thick Aluminum Composite Panel Plain In Color And Exterior Grade Wall Paneling System For Structure Preparation Option -1 Level Should Be Marked On The Wall As Per The Drawing, And Fix Cold Rolled Form €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Cold Rolled Form €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Centre To Centre. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel / Ceiling Section.Option-2 15 Mm Thick 0.5 Mm Density Solid Pvc Panel Strip Having Size Of 50Mm X Required Length Or Width Should Be Fixed To Wall Using Nylon Sleeve And Self Drilling Screws To Form Structure Grid 600Mmx 600Mm. 3Mm Thick Aluminum Plain In Color And Exterior Grade €Œalex €Œ / €Flexi Bond†/ Brand Approved Brand By Nau Authority Should Be Fixed To Above Framing Structure Using 3M Brand Self Adhesive Double Gum Tape And Daw Corning Brand Silicon As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of 6 Mm Thick Hpl ( Height Pressure Compact Laminate Prelaminated Panel Wall Paneling :- For Providing And 8 Mm Thick Both Side Prelaminated Cement Bonded Particle Panel Paneling System For Structure Preparation Level Should Be Marked On The Wall As Per The Drawing, And Fix Cold Rolled Form €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority Cold Rolled Form Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Centre To Centre. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel 6 / 8 Mm Thick Interior Grade Hpl Prelaminated Board €Œcompact King†Or Equalant Brand Approved By Nau Authority Should Be Fixed To Above Framing Structure Using 3M Brand Self Adhesive Double Gum Tape And Daw Corning Brand Silicon As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing Fixing Glass Reinforced Gypsum Designer Wall Paneling For Acoustical Purpose ( Perforated ) : -.For Providing And Fixing Wall Paneling System Level Should Be Marked On The Wall As Per The Drawing, And Fix Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed 0.5 Mm Thick G.I. €Œu†Shaped Perimeter Channel Having Web 26 Mm And Flange 20 Mm & 27 Mm To The Perimeter Of The Wall With Nylon Sleeves And Screws ( 38 Mm Long Or More ) At 610 Mm Centers, At The Required Level. Approved Brand €Œgyptech†Or Equivalent And Approved Brand By Nau Authority Cold Rolled Formed Ceiling Sections Having Both Flange 22 Mm & Web 51 Mm Should Be Inserted In To The Perimeter Channel 600 Mm Center To Center. Cross Checking Should Be Done To Plumb And Fix The Inserts Where Ever Required Behind The Perimeter Channel / Ceiling Section. 12 Mm Thick Perforated Glass Fiber Reinforce Gypsum Board €Œgypsonic†/ Equalant Brand Approved By Nau Authority Should Be Screw Fixed To The Frame With Under Head Cutter. If Required Recessing Should Be Done Of Size 40Mm X 1.5Mm On Board If Boards Square Edged. The Boards Should Be Fixed To The Ceiling Sections Using Self-Drilling Csk Screws Of 7G X 25Mm @ 200Mm Intervals In The Same Direction To The Framing So That Board Should Have A Continuous Support. Extra Ceiling Section Should Be Fixed Wherever Required To Support The Boards. A Gap Of 2 To 3 Mm Should Be Provided Between The Boards. The Csk Screws Should Be Fixed From The Edge Least1.5 Times The Thickness Of Board ( Centre Of The Screw ) And 40Mm From The Corners At An Interval Of 200 Mm. The Joints Between The Boards Are Staggered In Brick Pattern If Permitted By Architect For Better Strength; Otherwise Fix It Straight Line To Have Uniform Groove Finish. Board Joints Should Be Finished With Jointing Compound And Fiber Tape To Get Joint Less Finish. If Required Water Based Wood Primer Should Be Applied On Entire Surface Before Applying Putty Or Paint. Two Coat Of Approved Shade Distemper Should Be Applied To Paneling Work And Same Will Be Paid Extra As Approved Rates. Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Plain In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) :- For Providing And Fixing 3 Mm Thick Aluminum Composite Panel Plain In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) For Structure Preparation Level Should Be Marked On The Wall As Per The Drawing, And Fix G.I Square Or Rectangular Tube Section Welded Grid Having Average Size Of 600 Mm X 900 Mm . The Structure Cost Will Be Paid Separately A Per Approved Rates. 3Mm Thick Aluminum Plain In Color And Exterior Grade €Œalex €Œ / €Flexi Bond†/ Brand Approved Brand By Nau Authority Should Be Fixed To Above Framing Structure Using 3M Brand Self Adhesive Double Gum Tape And Daw Corning Brand Silicon As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Premium In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) :- For Providing And Fixing 3 Mm Thick Aluminum Composite Panel Plain In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) For Structure Preparation Level Should Be Marked On The Wall As Per The Drawing, And Fix G.I Square Or Rectangular Tube Section Welded Grid Having Average Size Of 600 Mm X 900 Mm . The Structure Cost Will Be Paid Separately A Per Approved Rates. 3Mm Thick Aluminum Premium In Color And Exterior Grade €Œalex €Œ / €Flexi Bond†/ Brand Approved Brand By Nau Authority Should Be Fixed To Above Framing Structure Using 3M Brand Self Adhesive Double Gum Tape And Daw Corning Brand Silicon As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of 3 Mm Thick Wood Plastic Composite Panel Premium In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) :- For Providing And Fixing 20 Mm Thick Wood Plastic Composite Panel Wooden Texture In Color And Exterior Grade Curtain Wall Cladding ( Elivation Purpose ) For Structure Preparation Level Should Be Marked On The Wall As Per The Drawing, And Fix G.I Square Or Rectangular Tube Section Welded Grid Having Average Size Of 600 Mm X 900 Mm . The Structure Cost Will Be Paid Separately A Per Approved Rates. 20 Mm Thick Wood Plastic Composite Premium In Color And Exterior Grade Having Tongue And Groove System €Œstarton‌ / €Mepac†/ Brand Approved Brand By Nau Authority Should Be Fixed To Above Framing Structure Using Anticorrosive Self Drilling Screws As Per Given Design . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing And Fixing Roller Blinds: -Manufactured By Iso 9001-2000 Certified €Œmarvel†Or Equivalent And Approved Brand By Nau Authority .The Track Should Be Of Aluminum Acrylic Coating Resistant To Cracking And Fraying. With Required Mechanism. The Fabric Should 0.50 Mm Thick Approved Quality Washable Polyester Woven Fabric And Color And Design Weight 200 To 300 Gm / Smt ( Shade Acute Plain, Bright Translucent, Lush Black Out, Soft Translucent, Acute Screen Prints, Castle Translate, Flourish Translate, Bamboo Blinds. ) Operating System And Quality String Should Be Used. Entire Work Should Be Carried Out In Good Finish And As Directed By Authority., Providing And Fixing 2.5 Mm Thick P.V.C.Carpet:- 2.5 Mm Thick Vinyl Chloride Flooring Carpet Of Wonder Floor Of Approved Brand, Design And Color From Approved & Branded Company In Any Shade & Color Including Cost Of Labor, Material Adhesive And Wastage Etc Complete As Directed By Engineer In Charge., Providing And Fixing 2.0 Mm Thick P.V.C.Carpet:- 2 Mm Thick Vinyl Chloride Flooring Carpet Of Wonder Floor Of Approved Brand, Design And Color From In Strip Or Roll Form Any Shade & Color Including Cost Of Labor, Material Adhesive And Wastage Etc Complete As Directed By Engineer In Charge., Providing And Fixing 6.0 Mm Thick Stone Plastic Composite Flooring:- For Providing And Fixing 6.0 Mm Thick Stone Plastic Composite Flooring Of Polywood / Exrodo Or Approved Brand, Design And Color From In Planks Having Size Of 184 Mm X 1220 Mm And 6 Mm Thick .Having Core Density Of 1.95+ / - 0.05.Gloss Level Of 5-8 . Any Shade & Color Including Cost Of Labor, Material Adhesive And Wastage Etc Complete As Directed By Engineer In Charge, Providing And Fixing Drywall Partition Non-Load Bearing Non M.R Gypsum Board / Cement Fiber Board / Calcium Silicate Board Steel Stud Partitions: - The Partition Should Be Assembled At Site Using Steel Sections To Make A Frame. Non M.R Gypsum Board 12.5 Mm Thick €Œgyprock†/ Gyptech†/ Cement Bonded Particle Board €Œbison†Or Equalant Brand 8Mm Thick / Calcium Silicate Board €Œramco†Or Equalant Brand 8Mm Thick ( Approved Brand By Nau Authority ) Should Be Fixed To Either Side Of This Frame Using Self-Drilling Csk Screws Of Suitable Length 25Mm / 38Mm Etc At 200 Mm Centers, Maintaining A Gap Of 2.0 Mm Between The Boards. The Screws Will Be Kept 15 Mm Or 1.5 Times The Thickness Of The Board, Away From The Edge And 40 Mm From The Corner. Stud Dimension Should Be 0.55 Mm Thick 48 Mm Wide Having Two Unequal Flanges Of 34.5 Mm And 37 Mm Gyptech Or Equalant Brand Approved Brand By Nau Authority. Floor Channel Dimension Should Be 0.55 Mm Thick 50 Mm Wide Having Two Equal Flanges Of 30 Mm Gyptech Or Approved Brand By Nau Authority. Floor Channel Should Be Fixed As Per The Layout Plan At 610Mm Spacing Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length. Top Channel Should Be Fixed To The Slab In Line And Plumb To The Floor Channel. Then The Studs Will Be Inserted Into The Floor Channel At 601 Mm / 611 Mm Centers. The Cut Outs Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Should Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. The Gypsum Board / 8 Mm Thick Cement Bonded Particle Board / 8 Mm Thick Calcium Silicate Board Will Be Screws Fixed To Either Side Of The Frame Work Using Self Drilling And Tapping Screws Of Csk Head At 200 Mm Centers. The Screws Will Be Kept 15 Mm ( Minimum ) Or 1.5 Times The Thickness Of The Board, Away From The Edge And 40 Mm From The Corner. A Gap Of 2Mm Is Will Be Maintained Between The Boards. First Board Will Be Of 2€™ / 610Mm Followed By 1220Mm Boards On Side Of The Frame Work. On The Other Side Start The Fixing With 1220Mm Board Followed By 1220Mm Boards For Making The Partition More Stable And Strong. While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Board Inserted Fixed At This Junction, Between Two Studs. Fixed Glass Window If Required Should Be Provided Using 5 Mm Plain Glass And 20 Mm Thick Wooden Beading. Rockwool Slabs Of 50Mm As Per The Stud Dimension And The Recommendations Will Be Inserted In The Cavity For Insulation ( Both Acoustic As Well As Thermal ) Purpose. The Rock Wool Cost Will Be Paid Separately As Per Approved Rate. Door And Door Frame Will Be Paid Separately As Per Approved Rate Not Deducting Partition Measurements. Board Joints Should Be Finished With Jointing Compound And Fiber Tape As Per Recommended Practice. Primer ( Water Based ) Should Be Used On Entire Surface Before App, Providing And Fixing Drywall Acoustical Partition Non-Load Bearing Using Non M.R Gypsum Board And Cement Fiber Board / Calcium Silicate Board Steel Stud Partitions: - The Partition Should Be Assembled At Site Using Steel Sections To Make A Frame. Non M.R Gypsum Board 12.5 Mm Thick €Œgyprock†/ Gyptech†And Cement Bonded Particle Board €Œbison†Or Equalant Brand 10 Mm Thick / Calcium Silicate Board €Œramco†Or Equalant Brand 8Mm Thick ( Approved Brand By Nau Authority ) Should Be Fixed To Either Side Of This Frame Using Self-Drilling Csk Screws Of Suitable Length 25Mm / 38Mm Etc At 200 Mm Centers, Maintaining A Gap Of 2.0 Mm Between The Boards. The Screws Will Be Kept 15 Mm Or 1.5 Times The Thickness Of The Board, Away From The Edge And 40 Mm From The Corner. Stud Dimension Should Be 0.55 Mm Thick 48 Mm Wide Having Two Unequal Flanges Of 34.5 Mm And 37 Mm Gyptech Or Equalant Brand Approved Brand By Nau Authority. Floor Channel Dimension Should Be 0.55 Mm Thick 50 Mm Wide Having Two Equal Flanges Of 30 Mm Gyptech Or Approved Brand By Nau Authority. Floor Channel Should Be Fixed As Per The Layout Plan At 610Mm Spacing Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length. Top Channel Should Be Fixed To The Slab In Line And Plumb To The Floor Channel. Then The Studs Will Be Inserted Into The Floor Channel At 601 Mm / 611 Mm Centers. The Cut Outs Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Should Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. The Gypsum Board And 10 Mm Thick Cement Bonded Particle Board / 10 Mm Thick Calcium Silicate Board Will Be Screws Fixed To Either Side Of The Frame Work Using Self Drilling And Tapping Screws Of Csk Head At 200 Mm Centers. The Screws Will Be Kept 15 Mm ( Minimum ) Or 1.5 Times The Thickness Of The Board, Away From The Edge And 40 Mm From The Corner. A Gap Of 2Mm Is Will Be Maintained Between The Boards. First Board Will Be Of 2€™ / 610Mm Followed By 1220Mm Boards On Side Of The Frame Work. On The Other Side Start The Fixing With 1220Mm Board Followed By 1220Mm Boards For Making The Partition More Stable And Strong. While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Board Inserted Fixed At This Junction, Between Two Studs. Fixed Glass Window If Required Should Be Provided Using 5 Mm Plain Glass And 20 Mm Thick Wooden Beading. Rockwool Slabs Of 50Mm As Per The Stud Dimension And The Recommendations Will Be Inserted In The Cavity For Insulation ( Both Acoustic As Well As Thermal ) Purpose. The Rock Wool Cost Will Be Paid Separately As Per Approved Rate. Door And Door Frame Will Be Paid Separately As Per Approved Rate Not Deducting Partition Measurements. Board Joints Should Be Finished With Jointing Compound And Fiber Tape As Per Recommended Practice. Primer ( Water Based ) Should Be Used, Providing, Supplying & Installation Of 9 Mm / 10Mm Thick Membrane Coated Stone Plastic Composite Section Double Screen Steel Track & Stud Partitions: - The Partition Should Be Assembled At Site Using Light Gauge Cold Rolled Formed Galvanized Steel Sections Having Minimum Thickness 0.55 Mm To Make A Frame. Iso 9001 Certified €Œsintex†Or €Œpoly Wood‌ Equivalent And Approved Brand By Nau Authority Make 9 Mm Thick Membrane Coated Stone Plastic Composite Panel Designer Series Section Should Be Fixed To Either Side Of This Frame Using Self-Drilling Csk Screws Of Suitable Length 25Mm / 38Mm Etc . . €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Form 0.0.55 Mm Thick G.I Floor Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed As Per The Layout Plan At Floor Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length At 450 Mm / 610Mm Spacing. . €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority Cold Rolled Form 0.55 Mm Thick G.I Top Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed To The Slab Or Soffit In Line And Plumb To The Floor Channel. Then The. €Œgyptech €Œ Or Equivalent And Approved Brand By Nau Authority 0.55 Mm Thick G.I Studs Section Having Size Of 34 Mm X 48.5 Mm X 37 Mm Will Be Inserted Into The Floor Channel At 601 Mm Centers Or 450 Mm Centers. The Cut Outs Should Be Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Will Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. For The Door And Window Opening Head And Bottom Track Should Be G.I 0.55 Mm Thick Having Size Of 30 Mm X 50 Mm X 30 Mm. The Door And Window Head And Bottom Track Should Be Rain Forced With Seasoned Wood Having Size Of 47 Mm X 34 Mm. The Distance Between Two Studs Should Not Be More Than 300 Mm At Door And Window Opening. 9Mm Thick Membrane Coated Spc 250 Mm Wide Iso 9001 Certified €Œsintex €Œor €Œpolywood†Make Equivalent And Approved Brand By Nau Authority Membrane Coated Designer Series Multy Chambered Hollow Plastic Section Having Minimum Wall Thickness 0.2 Mm +- 0.015 X 300 / 250 Mm Wide And Tongue And Groove Joining System Should Be Will Be Screws Fixed To Either Side Of The Frame Work Using Self Drilling And Tapping Screws Of Csk Head While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Panel Inserted Fixed At This Junction, Between Two Studs.  . All Opened End Will Be Covered With €Œu†Shape 9 Mm X 28 Pvc Section Or €Œl†Shape Pvc Section Having Size Of 25 Mm X 25 Mm. Vertical Wall Panel And Ceiling Panel Should Be Decorated At Joing Point 35 X 35Mm Double Side Cornice Section Or 25 Mm X30 Mm Single Cornice Section Cynoacrylate Adhesive Of &Quot;Thanga Bond S-302&Quot; Equivalent And Approved Brand By Nau Authority Should Be Used For Joining Panel And Capping Section. Entire Work, Providing Vinyl Wall Paper On Partitions: - For Providing Fixing Wall Paper Of Approved Brand By Nau Authority On Dry Wall Or Wall Or Cement Sandwich Partition The Vinyl Wall Paper Should Be Whether Proof And Approved Design. It Should Be Installed As Per Company Standard Practices Removing Dirt As Well As Dent And Making The Surface Smooth. Standard Marine Grade Adhesive Should Be Used. Rates Should Be Including Wastage. . Entre Work Should Be Done In Good Finish, Line And True Level As Directed By Engineer In Charge., Providing Laminate On Partitions / Wall Paneling / Ceiling: - For Providing Fixing 1 Mm Thick Laminate On Dry Wall Or Wall Paneling Or Cement Sandwich Partition The 1 Mm Thick Laminate Of Approved Brand Timex / Greenlam / Marino / Veer Or Equivalent And Approved Brand By Nau Authority Design Laminate. It Should Be Installed As Per Company Standard Practices Removing Dirt As Well As Dent And Making The Surface. Standard Marine Grade Adhesive Favicol Hyper Or Approved Brand By Nau Authority Or Should Be Used. Rates Should Be Including Wastage. . Entire Work Should Be Done In Good Finish, Line And True Level As Directed By Engineer In Charge., Providing And Placing Rock Wool For Insulation: - 50 Mm Thick Rock Wool Slab Having Density Of 40 Kg / Cubic Meter Of Approved Brand By Nau Authority Should Be Placed Between Wall Structure And Wall Panels Or Roofing And Ceiling Panel For Acoustical Insulation And Heat Prevention Purpose. Entire Work Should Be Done In Good Finish, Line And True Level As Directed By Engineer In Charge., Providing, Supplying, Paint Work On Drywall Partition: - For Providing, Supplying, Paint Work On Drywall Partition The Surface Should Be Cleaned And Sanded To Remove Dirt. One Coat Of Primer Of Approved Brand Like Asian, Burger, Or Equivalent And Approved Brand By Nau Authority Should Be Applied On Surface Of Partition Then One Coat Or As Required Of Birla / J.K.Laxmi Or Equivalent Brand Putty Should Be Applied To Make Surface Smooth And Leveled .Then Two Coat Of Approved Brand Like Asian, Burger Whether Protective Paint Should Be Applied Entire Work Should Be Done In Good Finish, Line And True Level As Directed By Engineer In Charge., Providing And Fixing Color Anodized / Powder Coated Aluminum Section Partition: - For Providing And Fixing Partly Paneled And Partly Glazed Aluminum Section Partition The Aluminum Section Should Be Banco / National / Hindalco / Jindal Or Equivalent And Approved Brand By Nau Authority Color Anodized. For Bottom, Top And Side Section Should Be Single Partition Member Section Having Thickness Of 2 Mm And Size 63.30 X 38.00 Wt 1.08 To 1.12Kg / M For All Internal Vertical And Horizontal Member Should Be Double Partition Member Having Thickness Of 2 Mm And Size 63.50 X 38.1 X 2Mm Wt 1.13Kg To 1.08 Kg / M ) . The Glazing Clip Should Be Used For Fixing Glass Or Panel Should Be 0.55 Mm Thick And Size 19 X 17.20 X 0.55Mm Wt 0.12 Kg / Mt With Jumbo Epdm Rubber. For Infill 5Mm Thick Clear Or Colored Glass Should Of €Œsain Gobban†Or €Œmodigaurd†And 3Mm Thick Aluminum Composite Panel Of €Œflexi Bond†Or €Œalex €Œor Equivalent And Approved Brand By Nau Authority. Whether Proof Silicon Sealant Should Be Used To Seal Peripheral Gap. Entire Work Will Be Furnished In Good Shape And Design As Directed By Engineer In Charge, Providing, Supplying & Installation Of 60 Mm Thick Solid Pvc Double Screen Steel Track & Stud Partitions ( Full Height ) : - The Partition Should Be Assembled At Site Using Light Gauge Cold Rolled Formed Galvanized Steel Sections €Œgyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority Having Minimum Thickness 0.55 Mm To Make A Frame. Prelaminated Panel 5 Mm ( + / - 0.25Mm ) Thick Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Or Equivalent And Approved Brand By Nau Authority Should Be Fixed To Either Side Of This Frame Using Self-Drilling Suitable Solvent Cement Adhesive . Cold Rolled Form 0.55 Mm Thick G.I Floor Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed As Per The Layout Plan At Floor Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length At 450 Mm / 610Mm Spacing. Cold Rolled Form 0.55 Mm Thick G.I Top Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed To The Slab Or Soffit In Line And Plumb To The Floor Channel. Then The 0.55 G.I Studs Section Having Size Of 34 Mm X 48.5 Mm X 37 Mm Will Be Inserted Into The Floor Channel At 601 Mm Centers Or 450 Mm Centers. The Cut Outs Should Be Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Will Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. For The Door And Window Opening Head And Bottom Track Should Be G.I 0.55 Mm Thick Having Size Of 30 Mm X 50 Mm X 30 Mm. The Door And Window Head And Bottom Track Should Be Rain Forced With Seasoned Wood Having Size Of 47 Mm X 34 Mm. The Distance Between Two Studs Should Not Be More Than 300 Mm At Door And Window Opening. 40 Mm Wide 5 Mm ( + / - 0.25Mm ) Thick Manufactured By Iso 9000-2015 Company Rajshree / Giza / Or Equivalent And Approved Brand By Nau Authority Having Size Of 50 Mm Wide Should Be Screw Fixed To Floor , Head Channel And Vertical Stud . 5 Mm ( + / - 0.25Mm ) Thick And 30 Mm Wide Having Density 600Kgs / Cubic Meter Solid Pvc Sheet Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority Should Be Fixed To Tall Track And Stud Face Side Using Screws. 5 Mm ( + / - 0.25Mm ) Thick Having Density 600Kgs / Cubic Meter Prelaminated Solid Pvc Sheet Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority Should Be Used For To Clad N Both Side Of The Partition Using Solvent Cement Adhesive . While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Panel Inserted Fixed At This Junction, Between Two Studs.  . All Opened End Will Be Covered With €Œc†/ €Œl†Shape Channel Prepared From 5 Mm ( + / - 0.25Mm ) Thick Having Density 600Kgs / Cubic Meter Prelaminated Solid Pvc Sheet Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority, Providing, Supplying & Installation Of 60 Mm Thick Solid Pvc Double Screen ( Low Height Partition ) : - The Partition Should Be Assembled At Site Using 2.0 Mm Thick 50 Mm X 25 Mm / 50 Mm X 50 Mm €Œasian†/ €Œapollo €Œ Or Equivalent And Approved Brand By Nau Authority Galvanized Steel Rectangular / Square As Main Framing Section And Light Gauge Cold Rolled Formed Galvanized Steel Sections €Œgyptech†/ €Œhi Steel†/ Gyprock Or Equivalent And Approved Brand By Nau Authority Having Minimum Thickness 0.6 Mm As Secondary Section To Make A Frame. All The Section Used For Partition Structure Should Be Cladded From Both Face Side With 5 Mm Thick X 50 Mm Wide Panel Strip Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority With The Help Of Self Drilling Screws In Required Size And Quantity. 5 Mm Thick ( + / -0.15 Mm ) Prelaminated Panel Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority Should Be Cladded On Both Side Structure Placing 40 Mm Thick High Density Expanded Poly Styrene Panel In Cavity Using Cement Solvent Adhesive. 5 Mm ( + / - 0.25Mm ) Thick Heat Molded / Heat Bent €Œc†Channel Made Out From Prelaminated Solid Pvc Sheet Having Density 600Kgs / Cubic Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority Having Size Of 50 Mm X 100 Mm With Feathered Edge Shall Be Fixed On The Floor And 50 Mm X 75 Mm With Feathered Edges Plain / Prelam Pvc €Œc†Channel On All Exposed Edge Using Cement Solvent Adhesive. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Premium Shade And Exterior Grade Double Screen Steel Track & Stud Partitions: - The Partition Should Be Assembled At Site Using Galvanized Steel Sections To Make A Frame. Alex / Flexi Bond / Approved Brand By Nau Authority Make 3 Mm Thick Exterior Grade Premium Shade Wood / Marble Designed Aluminum Composite Panel Should Be Fixed To Either Side Of This Frame Using 3M Brand / Approved Brand By Nau Authority Self Adhesive Tape And Dow Cornig Brand Silicon. €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority Cold Rolled Form 0.5 Mm Thick G.I Floor Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed As Per The Layout Plan At 450 Mm / 610Mm Spacing Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length. €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority 0.55 Mm Thick G.I Top Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed To The Slab Or Soffit In Line And Plumb To The Floor Channel. Then The Cold Rolled Form 0.55 G.I Studs Section Having Size Of 34 Mm X 48.5 Mm X 37 Mm Will Be Inserted Into The Floor Channel At 601 Mm / 611 Mm Centers. The Cut Outs Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Will Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. For The Door And Window Opening Head And Bottom Track Should Be G.I 0.55 Mm Thick Having Size Of 30 Mm X 50 Mm X 30 Mm. The Door And Window Head And Bottom Track Should Be Rain Forced With Seasoned Wood Having Size Of 47 Mm X 34 Mm. The Distance Between Two Studs Should Not Be More Than 300 Mm At Door And Window Opening. 3 / 4 Mm Thick Aluminum Composite Panel Will Be Fixed To Either Side Of The Frame Work Using Self Adhesive Tape And Silicon As Per Approved Design And Color While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Panel Inserted Fixed At This Junction, Between Two Studs.  . All Opened End Will Be Covered With Aluminum Composite Panel Grooved And Folding The Same In Required Shape. If Required Fixed Glass Window The Glass Should Be Minimum 8 Mm In Thickness. All Sliding Type Window And Door Frame And Door Will Be Paid As Per Approved Rate Only Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing, Supplying & Installation Of 3 Mm Thick Aluminum Composite Panel Plain Shade And Exterior Grade Double Screen Steel Track & Stud Partitions: - The Partition Should Be Assembled At Site Using Galvanized Steel Sections To Make A Frame. Alex / Flexi Bond / Approved Brand By Nau Authority Make 3 Mm Thick Exterior Grade Plain Shade Wood / Marble Designed Aluminum Composite Panel Should Be Fixed To Either Side Of This Frame Using 3M Brand / Approved Brand By Nau Authority Self Adhesive Tape And Dow Cornig Brand Silicon. €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority Cold Rolled Form 0.5 Mm Thick G.I Floor Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed As Per The Layout Plan At 450 Mm / 610Mm Spacing Using Nylon Sleeve And Screws Or Anchor Fasteners Of 6Mm Or 8Mm Diameter Of Suitable Length. €Œgyptech†/ €Gyprock†/ Equalant Brand Approved By Nau Authority 0.55 Mm Thick G.I Top Channel Having Size Of 30 Mm X 50 Mm X 30 Mm Should Be Fixed To The Slab Or Soffit In Line And Plumb To The Floor Channel. Then The Cold Rolled Form 0.55 G.I Studs Section Having Size Of 34 Mm X 48.5 Mm X 37 Mm Will Be Inserted Into The Floor Channel At 601 Mm / 611 Mm Centers. The Cut Outs Provided In The Web Of Studs Are Kept In A Line To Accommodate The Service Pipes Like Electrical And Plumbing In The Cavity Of The Partition. The Studs Will Be Cut Short In Length By 5 Mm Before Inserting Into The Floor Channel, To Maintain The Line And Level Through-Out The Length Of The Partition. For The Door And Window Opening Head And Bottom Track Should Be G.I 0.55 Mm Thick Having Size Of 30 Mm X 50 Mm X 30 Mm. The Door And Window Head And Bottom Track Should Be Rain Forced With Seasoned Wood Having Size Of 47 Mm X 34 Mm. The Distance Between Two Studs Should Not Be More Than 300 Mm At Door And Window Opening. 3 / 4 Mm Thick Aluminum Composite Panel Will Be Fixed To Either Side Of The Frame Work Using Self Adhesive Tape And Silicon As Per Approved Design And Color While Making An €Œl†Or €Œt†Joint, Care Will Be Taken For Panel Inserted Fixed At This Junction, Between Two Studs.  . All Opened End Will Be Covered With Aluminum Composite Panel Grooved And Folding The Same In Required Shape. If Required Fixed Glass Window The Glass Should Be Minimum 8 Mm In Thickness. All Sliding Type Window And Door Frame And Door Will Be Paid As Per Approved Rate Only Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Low Height Modular Partition For Office Cubicles:-For Providing And Fixing Low Height Partition For Office Cubicles Should Be Made Out From Powder Coated Or Color Anodized €Œgilt Edge €Œ Or Equalant Brand Approved By Nau Authority Extruded Aluminum Section Structure. The Base Frame Should Be G-2989 Having Size Of 60 Mm X 19.5 Mm And Average Weight Should 420 Grams / Rmt. Both Sides Vertical Track Should Be G-2984 Having Size Of 60 Mm X 19 Mm And Average Weight Should 460 Grams / Rmt. For Race Way Provision Internal Section From Bottom Should Be G-2989 Having Size Of 60 Mm X 19.5 Mm And Average Weight Should 420 Grams / Rmt With Raceway Cap G-2993 Having Size Of 145 Mm X 1.7 Mm And Average Weight Should 770 Grams / Rmt. Internal Horizontal Section From Top To Hold Glass / Pinup Boards / Marking Boards Should Be G-2988 Having Size Of 60 Mm X 5.5 Mm And Average Weight Should 321Grams / Rmt And G-2986 Having Size Of 60 Mm X 7.2 Mm Average Weight Should 290 Grams / Rmt. Top Covering And Side Covering Section Should Be G-2983 Having Size Of 60 Mm X 7.7 Mm Average Weight Should 243 Grams / Rmt. To Inter Connect Right Angle Partitions Gx 201 And Gx 207 L Shaped Connector Should Be Used. To Adjust The Level Of Entire Partition Floor Adjusting Devise Screw With Bottom Polymeric Wheel Gx 203+Gx 204 Should Be Provided. To Hold The Desk Panel Aluminum Section Having Size Of 46 Mm X 12 Mm Section Code G2990 Average Weight Of 280 Grams / Meter Should Be Inserted In All Front And Both Side Partition At Required Height .Both Screen Of Partition Should Be 6 Mm Thick Prelaminated Cement Bonded Particle Board / 6 Mm Thick Glass Of Approved Brand And If Required Pinup Board Or Marker Board Should Be Provided In Required Manner. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing High Height Partly Paneled And Partly Glazed Modular Partition For Office:-For Providing And Fixing High Height Partly Paneled And Partly Glazed Partition Self Standing Type For Office Should Be Made Out From Powder Coated Or Color Anodized €Œgilt Edge €Œ Or Equalant Brand Approved Brand By Nau Authority Aluminum Section Structure. The Base Frame Should Be Combination Of G-007 Having Size Of 56 Mm X 40 Mm Average Weight Should 452 Grams / Rmt As Well As G-058 Having Size Of 77.8 Mm X 26.9 Mm An Average Weight Should 498 Grams / Rmt . Both Sides Vertical, Horizontal Divisions Track Should Be G-052 Having Size Of 77.8 Mm X 18 Mm Average Weight Should Be 613 Grams / Rmt. The Average Distance Of All Vertical And Horizontal Section Should Not Be More Than 1100 Mm. Both Screen Of Partition Should Be 6 Mm Thick Prelaminated Cement Bonded Particle Board / 6 Mm Thick Glass Of Approved Brand Should Be Used With Epdm Gasket Gehc2 And G050 Having Size Of 18 Mm X 15.8 Mm Average Weight Should Be 108Grams / Rmt As Well As G066 Having Size Of 41.2Mm X 11.4 Mm Average Weight Should Be 203 Grams / Rmt. For Three Way / Four Way Partition G046 Having Size Of 80 Mm X 80 Mm Average Weight Should Be 1387Grams / Rmt Should Be Used. For €Œl†Shaped Partition G063 Having Size Of 80 Mm X 80 Mm Average Weight Should Be 1200 Grams / Rmt Should Be Used. Required Door Frame Should Be G043 Having Size Of 80 Mm X 25 Mm And Average Weight Of 1300 Grams / Rmt Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing High Height Fully Double Glazed Modular Partition For Office:-For Providing And Fixing High Height Fully Double Glazed Partition For Office Should Be Made Out From Powder Coated Or Color Anodized €Œgilt Edge €Œ Or Equalant Brand Approved By Nau Authority Aluminum Section Structure. The Base Frame Should Be Combination Of G-007 Having Size Of 56 Mm X 40 Mm Average Weight Should Be 452 Grams / Rmt As Well As G-058 Having Size Of 77.8 Mm X 26.9 Mm Average Weight Should Be 498 Grams / Rmt. Both Sides Vertical, Horizontal Divisions Track Should Be G-052 Having Size Of 77.8 Mm X 18 Mm Average Weight Should Be 613 Grams / Rmt. Both Screen Of Partition Should Be 6 Mm Thick Toughened Glass Of Approved Brand Should Be Used With Epdm Gasket Gehc2 And G050 Having Size Of 18 Mm X 15.8 Mm Average Weight Should Be 108Grams / Rmt As Well As G066 Having Size Of 41.2Mm X 11.4 Mm Average Weight Should Be 203 Grams / Rmt. For Three Way / Four Way Partition G046 Having Size Of 80 Mm X 80 Mm Average Weight Should Be 1387Grams / Rmt Should Be Used. For €Œl†Shaped Partition G063 Having Size Of 80 Mm X 80 Mm Average Weight Should Be 1200 Grams / Rmt Should Be Used. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Partly Paneled Partly Glazed / Fully Glazed Modular Door For Office:-For Providing And Fixing Partly Paneled Partly Glazed / Fully Glazed Modular Door Should Be Made Out From Powder Coated Or Color Anodized €Œgilt Edge €Œ Or Equalant Brand Approved By Nau Authority Aluminum Section Structure. The Frame Should Be G-043 Having Size Of 80 Mm X 40 Mm Average Weight Should Be 1295 Grams / Rmt. Door Frame Both Sides Vertical, Horizontal Section Should Be G-062 +S 58 Having Size Of 50Mm X 50 Mm Average Weight Should Be 990 Grams / Rmt. Infill Material For Door Should Be 10 Mm Toughened Glass Of Approved Brand Should Be Used With Epdm Gasket Gehc2 For Fully Glazed Door. For Partly Paneled 18 Mm Thick Particle Board Should Be Used. The Door Should Be Fixed To Frame Using 4 Numbers Of 150 Mm X 25 Mm X 25 Mm X 5 Mm Quality Hinges. Door Should Have Two Nos Of Approved Quality, Size Two Handles And Locking Device And Door Stay. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority, Providing And Laying Decorative Glass Film:-For Providing And Laying Decorative Glass Film The Covering Film Should Be Approved Brand Design And Quality. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Work Top:-For Providing And Fixing Work Top At Low Height Modular Cubicles The Top Should Be Cement Bonded Particle / 30 Mm Thick Marine Grade Play With 1Mm Thick Laminate On Top Surface And 0.8 Mm Thick Laminate On Either Surface With 2Mm Thick Bidding Patti And Powder Coated Or Color Anodized €Œgilt Edge €Œor Equalant Brand Approved By Nau Authority Aluminum Section Code G-2990 Having Size Of 40 Mm X 12 Mm Average Weight Should Be 280 Grams / Rmt. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Computer Key Board Tray With Mouse Holder:-For Providing And Fixing Computer Key Board Tray With Mouse Holder Under Work Top Of Low Height Modular Cubicles The Key Board Tray Should Be Made Out From Powder Coated Metal €Œebco†Computer Key Board Tray With Mouse Holder Kbtm 35 ( Bl ) 350 Mm ( Kbtm-35 ) Or Equalant Brand Approved By Nau Authority Powder Coated With Quality Runners And Required Hardware. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Computer Cpu Stand:-For Providing And Fixing Computer Cpu Stand Under Work Top Of Low Height Modular Cubicles. The Cpu Stand Should Be €Œebco†Brand Model Cpu ( T ) 1 ( Bl0 Telescopic ( Cpus ( T ) ) 1Or Equalant Brand Approved By Nau Authority Powder Coated With Quality Wheels Or Without Wheel But Under Table Mounting Type With Swivel And Pull Out Type Option. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Work Station Pedestal Drawer Unit:-For Providing And Fixing Pedestal Drawer Unit Should Be Made Out From 18 Mm Prelaminated Wood Base Particle Board €Œaction Tesa†Brand / 18 Mm Prelaminated Cement Bonded Particle Board With 2 Mm Edge Beading. Required Number Of Drawer And Shutter Should Be Providing With Quality Runner, Handle And Lock Etc. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing And Fixing Cement Sandwich Panel Partition: - The Panel Should Be Of 50 Mm Thick Cement Sandwich Panels €Œaerocon†/ €Œv- Panel†Approved Brand By Nau Authority Having Unique Tongue And Groove Joining System And Made Out From Two Fiber-Reinforced Cement Sheets Enclosing A Light Weight Core Composed Of Portland Cement, Binders And Mixture Salacious And Micaceous Materials Aggregates. Cold Rolled Formed €Œc&Quot; Channel Having Dimension 32Mm X 51 Mm X 35 Mm X 1.0 Mm Thick Should Be Fixed To Plinth / Floor And Roof Using 100 Mm X 8 Mm Screw With Pvc Wall Plug Reinforcement Having Dimension 125 Mm X 10 Mm As Per Floor Plan .The Average Distance Of Screw Used For Floor And Top Channel Should Be 450 Mm Minimum. The Required Height Panel Will Be Placed In Floor Mounted Channel. For €Œl†Shape, €Œt†Shape €Œc†Shape Partition At Corner Of Two Panel 2Mm Thick 75 Mm X 75 Mm X 75 Mm Inner And 2 Mm Thick 75 Mm X 75 Mm X 125 Mm Outer Corner Should Be Placed At Top And Bottom Using 75 Mm X 10 Mm Nut Bolt With Washer. The Top Of Panels Should Be Covered With &Quot;C&Quot; Channel. The Channel And Panel Should Be Fixed Using Self Tapping Screw Having Size Of 25Mm X 8Mm.Required €Œc&Quot; Channel For Pillars Covered Or Side Wall Or Top Should Be Used With Required Size Screw And Fastener. During Panel Installation All Window, Door And Ventilation Should Be Considered And All Opening Panel Edge Should Be Covered With G.I.&Quot;C&Quot; Channel And 60 Mm X 25 Mm Or Required Size Seasoned Teak Wood Batten Patti. As And Where Required Fixed Type 5 Mm Thick Plain Glass Window Should Be Provided. If Pillar Required It Should Be Of 75 Mm X 75 Mm M.S. Square Pipe With 200 Mm X 200 Mm X 5 Mm Base Plate .The Pillar With Base Plate Should Be Rested On Floor Using 100Mm X 15 Mm Self Expanding Nut Bolt. Steel Structure Coast Will Be Seperetly As Per Approved Rates. After Installation Of Panel All Gap Between Two Panels Should Be Fill Up With Acrylic Putty And €Œroff†Or Equalant Brand And The Partition Should Painted With Exterior Grade Whether Protective Paint At Exterior Side And At Inner Side Distemper Type Paint With Standard Paint Application System. If Required Steel Structure Sliding Type Window And Aluminum Partly Glazed , Fully Glazed , Pvc , Frp , Laminated Flush Door Should Be Installed And Same Will Be Paid Separately As Per Sor Or Approved Rate By This Office. All Work Should Carry Out With Good Finish And In True Line As Directed By Officer In Charge, Providing, Supplying & Installation Of Modular Work Station / Table Shared Type ( Up To 1200Mm X As Required Mm Top ) : - For Providing, Supplying & Installation Of Modular Work Station / Table Shared Type The Double Legs Should Be Color Coated Or Anodizesed Extruded Aluminum Section Having Taper Angle Of 3 Degree For The Leg Width And The Leg Itself Is 9 Degree Angled From True Vertical And The Size 80 Mm X 40 Mm At Top And Reduced Up To 40 Mm 40 Mm At Bottom 700 Mm Height. The Abs Plastic Mounting Cap Should Be Inserted In Legs To Rest The Top Panel. The Legs Should Be Assembled 1200 Mm Wide Color Coated Or Anodizesed Extruded Aluminum Section For Gable Frame Assembling. The Average Leg Frame Should Be At 1000 Mm To 1200 Mm The Two Gable Leg Frame Should Be Assembled Together Using Up To 1200 Mm Wide Color Coated Or Anodizesed Extruded Aluminum Section. The Top Of The Table Should Be 25 Mm Thick Four Side Edge Banded Prelaminated Mdf Or Ply. The Required Divider Will Be Paid Extra. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge. Rates Will Be Paid As Per Table Top Measurement, Providing, Supplying & Installation Of Modular Work Station Partition: - For Providing, Supplying & Installation Of Modular Work Station Partition The Main Section Should Be Color Coated Or Anodizesed Extruded Aluminum Section Having Size Of 28 Mm X 14 Mm , End Section Should Be Color Coated Or Anodizesed Extruded Aluminum Section Having Size Of 28 Mm X 17 Mm With 90Degree Connector And Abs Plastic Cap .The Infill Panel Should Be Soft Board On Both Sides / Prelam Panels Or Glass Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge, Providing Fixing And Supplying Conference Table Made Out From Moisture Resistant Ply As Per Design And Drawing: -For Providing Fixing And Supplying Conference Table ( Straight Line , €U†Shape , €C†Shape , Oval Shape ) Made Out From Moisture Resistant Ply All Panels Used For Conference Table Furniture ( Height 760 Mm To 830 Mm And Top Depth 600 Mm To 680 Mm. ) Should Be 18 Mm Thick Moisture Resistant Grade Isi Mark Silvi / Archid / Amul / Greenlam Or Equal Brand By Nau Authority Ply Board For All Vertical, Horizontal, And Front Panels. All Panels Will Be Assembled Using Required Screws And Marine Hyper Grade €Œfavicol†/ €Œeuro Bond†/ Equalant Brand By Nau Authority Adhesive As Per Guide Line Of Manufacturer. All Vertical And Horizontal Panels And Front Panels Should Be Covered From Both Side Approved Shade 1Mm Thick Laminate Of S.F Grade Veer / Green Lam / Timex / Amul And Equalant Brand By Nau Authority Manufactured By Iso 9000-2015 Company. As Per Design If Required All Peripheral Edge Should Be Thickened Using 50 Mm / 75 Mm / 100Mm Wide And Up To Required Thickness Using M.R. Grade Ply Panels And All Vertical Panel Should Be Doubled Up To 36 Mm . All Open Edge Should Be Covered With 2 Mm Thick Pvc Edge Bending Tape Or Seasoned Teak Wood Matching Polished Moldings. If Required Arrangement For Audio / Electrical Cable Track Should Be Arranged Under The Top And At Top €Œebco†Or Equalant Brand Cable Manager Should Be Provided. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority. Rates Will Be Paid As Per Table Top Measurement, Providing, Supplying & Installation Of Modular Work Station / Table No Shared Type ( Up To 680 Mm X 1200 Mm Top ) : - For Providing, Supplying & Installation Of Modular Work Station / Table Non Shared Type The Four Legs Should Be Color Coated Or Anodizesed Extruded Aluminum Section Having Taper Angle Of 3 Degree For The Leg Width And The Leg Itself Is 9 Degree Angled From True Vertical And The Size 80 Mm X 40 Mm At Top And Reduced Up To 40 Mm 40 Mm At Bottom 700 Mm Height. The Abs Plastic Mounting Cap Should Be Inserted In Legs To Rest The Top Panel. The Legs Should Be Assembled 600 Mm Wide Color Coated Or Anodizesed Extruded Aluminum Section For Gable Frame Assembling. The Two Gable Leg Frame Should Be Assembled Together Using Up To 1200 Mm Wide Color Coated Or Anodizesed Extruded Aluminum Section. The Top Of The Table Should Be 25 Mm Thick Four Side Edge Banded Prelaminated Mdf Or Ply. Entire Work Should Carry Out In True Line, Design And Finish As Directed By Engineer In Charge. Rates Will Be Paid As Per Table Top Measurement, Providing And Fixing Prelaminated 18 Mm Thick Solid Pvc Prelaminated Cabinet, Platform Shutter With Framing: - For Farming Consider Width Of Front, Top, Bottom, Internal Vertical And Horizontal Face Edge Of Cupboard / Platform And 50 Mm Inner Side Of Both Edge Should Be Covered With Solid Pvc Prelaminated Panel Using Required Size Self Drilling Screws In Required Quantity. The Shutter Should Be Made Out Of 18 Mm Thick Solid Pvc Panel And 1.2 Mm Thick Prelaminated Pvc Laminate Having Density 900Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authorities Shutter Should Be Of 18 Mm Thick Prelaminated Pvc Panel €Œpnp†Or Equalant Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. The Size Of Shutter Should Be Measured And Cut Accordingly .All The Edge Of Shutter Should Be Lipped With €Œrehu†/ Equalant Brand Approved By Nau Authority .The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†€Œor Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Prelaminated 18 Mm Thick Solid Pvc Cabinet, Platform Shutter Without Framing ( For Cupboard Platform Carcasses ) : - The Shutter Should Be Of 18 Mm Thick Prelaminated Pvc Panel €Œpnp†Or Equalant Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. The Size Of Shutter Should Be Measured And Cut Accordingly .All The Edge Of Shutter Should Be Lipped With €Œrehu†/ Equalant Brand Approved By Nau Authority .The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†€Œor Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Premium Shade Aluminum Composite Panel Cladded Cabinet, Platform Shutter Without Framing ( For Cupboard Platform Carcasses : - The Shutter Should Be Of 3 Mm Thick Plain Color Acp Panel Manufactured By Iso 9001 Certified Company €Œalex†/ €Œflexi Bond†€Œalstoneâ€Or Equalant Approved Brand Aluminum Composite Panel Premium Shade And 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. For Acp Shutter All Four Edges And Front Should Be Claded With Making Square Or Rectangular Tray Of Acp Having Edge Height Of 18 Mm All Around. 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œâ€Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter Should Be Placed And Fixed To Plain Color Acp Tray Using Dow Corning Silicon Adhesive .The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†€Œ Or Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Plain Color Aluminum Composite Panel Cladded Cabinet, Platform Shutter Without Framing ( For Cupboard Platform Carcasses ) : - The Shutter Should Be Of 3 Mm Thick Plain Color Acp Panel Manufactured By Iso 9001 Certified Company €Œalex†/ €Œflexi Bond†€Œalstoneâ€Or Equalant Approved Brand Aluminum Composite Panel Plain Color And 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. For Acp Shutter All Four Edges And Front Should Be Claded With Making Square Or Rectangular Tray Of Acp Having Edge Height Of 18 Mm All Around. 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œâ€Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter Should Be Placed And Fixed To Plain Color Acp Tray Using Dow Corning Silicon Adhesive .The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†€Œ Or Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Shutter With 1.2 Mm Thick Pvc Laminate With Frame: - - Providing, Supplying & Installation Of Solid Pvc And 1.2 Mm Thick Pvc Laminate Cupboard Shutter With Frame The Frame Should Be Of 18 Mm Thick Solid Pvc Panel Having Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority. For Farming Consider Width Of Front, Top, Bottom, Internal Vertical And Horizontal Face Edge Of Cupboard And 50 Mm Inner Side Of Both Edge Should Be Covered With Solid Pvc Panel Using Required Size Self Drilling Screws In Required Quantity Making Under Cut In Faming Pvc Panel. €Œc†Shaped Channel Of 1.2 Mm ( + / -0.15 Mm ) Thick Pvc Laminate Panel Having Density 900 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand Should Be Used To Cover 18 Mm Pvc Panel Framing Using Solvent Cement Adhesive. The Shutter Should Be Made Out Of 18 Mm Thick Solid Pvc Panel And 1.2 Mm Thick Prelaminated Pvc Laminate Having Density 900Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority. 18 Mm Pvc Panel Should Be Measured And Cut Considering Size Of Door And Cladded With 1.2 Mm Thick Solid Laminate Making Tray To Cover All The Edge Of Shutter. The Shutter Should Be Then Attached To Framing Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†Or Equalant Approved Brand Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge Or Stainless Approved Quality And Brand Steel Hinge Having Size Of 25 Mm X 100 Mm X 25 Mm In Required Quantity With Anticorrosive Screws. 75 Mm / 100Mm / 150Mm / 200Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Required Locking System Should Be Of €Œebco†Or Equal Brand Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Shutter With 1.2 Mm Thick Pvc Laminate To Pvc / Cement Bonded Particle Board Cupboard / Platform Carcasses : - Providing, Supplying & Installation Of Solid Pvc Shutter With 1.2 Mm Pvc Laminate . The Shutter Should Be Made Out Of 18 Mm Thick Solid Pvc Panel And 1.2Mm Thick Pvc Laminate Manufactured By Iso 9000-2015 Company Rajshree / Giza / Poly Wood / Equivalent And Approved Brand By Nau Authority. 18 Mm Thick Pvc Panel Should Be Measured And Cut Considering Size Of Door And Cladded To Front Side With 1.2 Mm Thick Pvc Laminate Making Tray To Cover All The Edge Of Shutter Or Alternatively 2 Mm Thick €Œrehu†Or Equivalent And Approved Brand By Nau Authority 18 Mm Wide Edge Banding Tape Can Be Used . The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†Or Equalant Approved Brand Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge Or Stainless Approved Quality And Brand Steel Hinge Having Size Of 25 Mm X 100 Mm X 25 Mm In Required Quantity With Anticorrosive Screws. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Shutter To Cupboard / Platform Carcasses Without Frame: - Providing, Supplying & Installation Of Solid Pvc Shutter. The Shutter Should Be Made Out Of 15 Mm Thick Solid Pvc Panel And 5 Mm Thick Prelaminated Pvc Panel Having Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority. 15 Mm Pvc Panel Should Be Measured And Cut Considering Size Of Door And Cladded With 5 Mm ( + / -0.15 Mm ) Thick Solid Pvc Prelaminated Panel Making Heat Molded Or Heat Bent Tray To Cover All The Edge Of Shutter. The Shutter Should Be Then Attached To Carcasses Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†Or Equalant Approved Brand Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge Or Stainless Approved Quality And Brand Steel Hinge Having Size Of 25 Mm X 100 Mm X 25 Mm In Required Quantity With Anticorrosive Screws. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Cupboard Shutter / Platform Shutter With Frame: - Providing, Supplying & Installation Of Solid Pvc Cupboard Shutter With Frame The Frame Should Be Of 15 Mm Thick Solid Pvc Panel Having Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority. For Farming Consider Width Of Front, Top, Bottom, Internal Vertical And Horizontal Face Edge Of Cupboard And 50 Mm Inner Side Of Both Edge Should Be Covered With Solid Pvc Panel Using Required Size Self Drilling Screws In Required Quantity Making Under Cut In Faming Pvc Panel. Heat Bent \ Heat Molded €Œc†Shaped Channel Of 5 Mm ( + / -0.15 Mm ) Thick Solid Pvc Prelaminated Panel Having Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority Should Be Used To Cover 15 Mm Pvc Panel Framing Using Solvent Cement Adhesive. The Shutter Should Be Made Out Of 15Mm Thick Solid Pvc Panel And 5 Mm Thick Prelaminated Pvc Panel Having Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equivalent And Approved Brand By Nau Authority. 15 Mm Pvc Panel Should Be Measured And Cut Considering Size Of Door And Cladded With 5 Mm ( + / -0.15 Mm ) Thick Solid Pvc Prelaminated Panel Making Heat Molded Or Heat Bent Tray To Cover All The Edge Of Shutter. The Shutter Should Be Then Attached To Framing Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†Or Equalant Approved Brand Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge Or Stainless Approved Quality And Brand Steel Hinge Having Size Of 25 Mm X 100 Mm X 25 Mm In Required Quantity With Anticorrosive Screws. 75 Mm / 100Mm / 150Mm / 200Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Required Locking System Should Be Of €Œebco†Or Equal Brand Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Premium Shade ( Wood / Marble Finish ) Aluminum Composite Panel Cabinet, Platform Shutter With Framing: - The Framing Of Cabinet, Platform Should Be Seasoned Teak Wood Having Size Of 25 To 40 Mm Thick X 75 Mm Or 40 Mm Thick X 75 Mm Solid Pvc / Wpc Panel Manufactured By Iso 9001 Certified Company €Œgiza†/ €Flexi Bond €Œor Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. The Framing Section Should Be Fixed To Existing Structure Using Self Expanding And Self Drilling Screws Of Required Size And Covered With Acp Panel By Groove Banding Process. The Shutter Should Of 3 Mm Thick Panel Manufactured By Iso 9001 Certified Company €Œalex†/ Flexi Bond†Or Equivalent And Approved Brand By Nau Authority Premium Shade ( Wood / Marble Finish Aluminum Composite Panel Plain Color And 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. For Acp Shutter All Four Edges And Front Should Be Claded With Making Square Or Rectangular Tray Of Acp Having Edge Height Of 18 Mm All Around. 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured €Œgiza†/ €Plasti Wood €Œor Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter Should Be Placed And Fixed To Premium Shade ( Wood / Marble Finish ) Acp Tray Using Dow Corning Silicon Adhesive .The Shutter Should Be Then Attached To Framing Section Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†Or Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Plain Color Aluminum Composite Panel Cladded Cabinet, Platform Shutter With Framing:- The Framing Of Cabinet, Platform Should Be Seasoned Teak Wood Having Size Of 25 To 40 Mm Thick X 75 Mm Or 40 Mm Thick X 75 Mm Solid Pvc / Wpc Panel Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. The Framing Section Should Be Fixed To Existing Structure Using Self Expanding And Self Drilling Screws Of Required Size. The Shutter Should Be Of 3 Mm Thick Plain Color Acp Panel Manufactured By Iso 9001 Certified Company €Œalex†/ €Œflexi Bond†€Œalstoneâ€Or Equalant Approved Brand Aluminum Composite Panel Plain Color And 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter. For Acp Shutter All Four Edges And Front Should Be Claded With Making Square Or Rectangular Tray Of Acp Having Edge Height Of 18 Mm All Around. 15 Mm Thick Solid Pvc Or Wpc Panel Manufactured By €Œgiza†/ €Plasti Wood €Œâ€Œ Or Equivalent And Approved Brand By Nau Authority Having Density 550 Kgs / Cubic Meter Should Be Placed And Fixed To Plain Color Acp Tray Using Dow Corning Silicon Adhesive .The Shutter Should Be Then Attached To Framing Section Using Required Number Of €Œkraft&Quot; / Ebco / €Œhattich†€Œ Or Equivalent And Approved Brand By Nau Authority Required Opening Fashion 0 Crank, 18 Crank Or 8 Crank Spring Hinge. 75 Mm X 8 Mm Stainless Steel Handle Of Approved Brand Should Be Provided To All Shutters. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Membrane Coated Multi Chambered Hollow Pvc Section Cabinet Or Loft Shutter: - For Membrane Coated Multi Chambered Hollow Pvc Section Cabinet Or Loft Shutter All The Profile Should Be Iso 9001 Certified €Œsintex†Or €Œpoly Wood €Œor Equivalent And Approved Brand By Nau Authority Membrane Coated Poly Vinyl Chloride Extruded Section Of Heavy Grade Not Eco Series. Both The Wall Thickness Of Infill Panel Must Be 1.8 Mm Minimum. The Framing Section Should Be Of Same Brand And Having Size Of 65Mm X 24 Mm Section Or 32Mm X 42 Mm Section. The Section Used For Outer Frame Should Be Reinforced With Seasoned Wood Of Required Size. For Assembling Of Outer Frame Solid Heavy Density Polymeric Corner Having Size Of 200 Mm X 85 Mm X 25 Mm Should Be Used At Four Corners. Aluminum &Quot;L&Quot; Section Having Size Of 0.5Mm X 25 Mm X 25Mm Should Be Used To Fixed The Outer Frame To Wall Of The Cabinet Or Loft. The Shutter Frame Should Be Membrane Coated €Œsintex†Or €Œpoly Wood €Œor Equivalent And Approved Brand By Nau Authority Poly Vinyl Chloride Extruded Section Having Size Of 40Mm X 24 Mm Section Code Or 30Mm X 60 Mm Section Code. For Assembling Of Outer Frame Solid Heavy Density Polymeric Corner Having Size Of 200 Mm X 85 Mm X 25 Mm Should Be Used At Four Corner For Each The Infill Panel Should Be 20Mm Thick Membrane Coated Poly Vinyl Chloride Multy Chambered Hollow Plastic Section In One Piece Only €Œsintex†Or €Œpoly Wood €Œor Equivalent And Approved Brand By Nau Authority. To Give Flush Look Of Shutter Instead Of Shutter Framing 20 Mm Wide Beading Cap Can Be Used .As And Where Required 5 Mm Plain Glass Should Be Provided Using 15 Mm X 20 Mm Section .To Fix Hinge At Side Of Shutter Frame And To Handle Or Knob With Accessory Required Reinforcement Should Be 15 Mm X 300 Mm Solid Heavy Density Polymeric Piece. Two Nos Or Required Number Of Hinges Should Be Of 60 Mm X 20 Mm X 25 Mm Stainless Steel With Quality Zinc Plated Screw Having Size Of 19 Mm X 06 Mm In Required Quantity. One Number Of Approved Qualities 75Mm X 6 Mm Stainless Steel Handle And Magnetic Catch Should Be With Each Shutter. Care Should Take While Installing Hardware All Screws Should Be Through In Reinforcement. All Gap And Panel And Chanel Should Be Joined Using &Quot;Thanga Bond†Adhesive Or Equivalent And Approved Brand By Nau Authority. All The Gap Between Shutter And Civil Work Should Furnish Using Approved Grade Silicon Sealant Entire Frame Work Should Be Done In True Line Level And Maintain Esthetic Value As Directed By Officer In Charge, Providing, Supplying & Installation Of Lab Platform Carcasses With Granite Top - For Providing And Fixing Lab Platform Carcasses. The Carcass Of Lab Platform Should Be Made Out Using 20 Mm And 8 Mm Thick Cement Compressed Particle Board Of &Quot;Bison&Quot; Or Equivalent And Approved Brand By Nau Authority .All Top, Side, Bottom And Salving Panel Should Be Of 20 Mm Thick Cement Compressed Particle Board. All Panels Should Be Assembled Using Required Size Anti Corrosive Screw And Adhesive. All Top, Side, Bottom And Salving Panel Should Be Assembled In True Line Level And Right Angle. Backing Panel Should Be 8 Mm Cement Compressed Particle Board. At Front Side Required Size Skirting Should Be Provided. The Front Edge Of All Top, Side, Bottom And Salving Panel Should Be Covered With 5 Thick X 20 Mm Width Seasoned Teak Wood Batten Or 2Mm Thick And 20 Mm Wide Approved Brand Edge Banding Tap. Care Should Be Taken For Vertical Panel Installation It Should Touch To Floor For Better Load Bearing Capacity Of Platform. Required Size Opening For Sink, Key Board And Leg Room Should Be Considered During Fabrication. The Top Of The Platform Should Be 15 Mm Thick Approved Quality And Design Granite Stone. It Should Be Place On Carcasses Using Cement Mortar Or Adhesive. The Front And Side Edge Should Be Rounded And Polish As Directed By Engineer In Charge. The Scarting And Exposed Side Of Platform Should Be Claded With The Material Used For Top Covering Material. Each Side Of All Panel Used For Lab Platform Carcasses Should Be Covered With Approved Brand Liner Grade Laminate . Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge. True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Lab Platform Carcasses With Laminate Top - For Providing And Fixing Lab Platform Carcasses. The Carcass Of Lab Platform Should Be Made Out Using 20 Mm And 8 Mm Thick Cement Compressed Particle Board Of &Quot;Bison&Quot; Or Equivalent And Approved Brand By Nau Authority .All Top, Side, Bottom And Salving Panel Should Be Of 20 Mm Thick Cement Compressed Particle Board. All Panels Should Be Assembled Using Required Size Anti Corrosive Screw And Adhesive. All Top, Side, Bottom And Salving Panel Should Be Assembled In True Line Level And Right Angle. Backing Panel Should Be 8 Mm Cement Compressed Particle Board. At Front Side Required Size Skirting Should Be Provided. The Front Edge Of All Top, Side, Bottom And Salving Panel Should Be Covered With 5 Thick X 20 Mm Width Teak Wood Batten. Care Should Be Taken For Vertical Panel Installation It Should Touch To Floor For Better Load Bearing Capacity Of Platform. Required Size Opening For Sink, Key Board And Leg Room Should Be Considered During Fabrication. The Top Of The Platform Should Be 1.0Mm Thick €Œveerâ€, €Œtimex†Or Approved Quality And Design Laminate. It Should Be Place On Carcasses Using Favicol Brand Marine Grade Adhesive Or Equivalent And Approved Brand By Nau Authority. The Front Edge Should Be Rounded And Polish As Directed By Engineer In. The Scarting And Exposed Side Of Platform Should Be Claded With The Material Used For Top Covering Material. Each Side Of All Panel Used For Lab Platform Carcasses Should Be Covered With Approved Brand Liner Grade Laminate. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing, Supplying & Installation Of Lab Platform Carcasses Using Prelaminated Cement Bonded Practical Board - For Providing And Fixing Lab Platform Carcasses. The Carcass Of Lab Platform Should Be Made Out Using18 Mm And 8 Mm Thick Cement Bonded Prelaminated Particle Board Of &Quot;Bison&Quot; Or Equivalent And Approved Brand By Nau Authority .All Top, Side, Bottom And Salving Panel Should Be Of 18 Mm Thick Cement Compressed Prelaminated Particle Board. All Panels Should Be Assembled Using Required Size Knock Down Type Hardware €Œebco†Or Equalant Approved Brand By Nau Authority Like Nylon Block Connector Fitting, Nylon Right Angle Connector, And Aluminum Right Angle Connector And Anti Corrosive Screw As Well As Adhesive. All Top, Side, Bottom And Salving Panel Should Be Assembled In True Line Level And Right Angle. Backing Panel Should Be 8 Mm Cement Compressed Prelaminated Particle Board. At Front Side Required Size Skirting Should Be Provided. The Front Edge Of All Top, Side, Bottom And Salving Panel Should Be Covered With 5 Thick X 20 Mm Width Teak Wood Batten. Care Should Be Taken For Vertical Panel Installation It Should Touch To Floor For Better Load Bearing Capacity Of Platform. Required Size Opening For Sink, Key Board And Leg Room Should Be Considered During Fabrication. The Top Of The Platform Should Be 1.0Mm Thick €Œveerâ€, €Œtimex†Or Approved Quality And Design Laminate On 8 Mm Thick Cement Bounded Particle Board Fixed To Top Panel . It Should Be Place On Carcasses Using Favicol Brand Marine Grade Adhesive Or Equivalent And Approved Brand By Nau Authority. The Front Edge Should Be Rounded And Polish As Directed By Engineer In. The Scarting And Exposed Side Of Platform Should Be Claded With The Material Used For Top Covering Material.. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Kitchen / Lab Platform / Service Platform Carcasses With Granite Top: -For Providing, Supplying & Installation Of Solid Pvc Kitchen / Lab Platform / Service Platform Carcasses With Granite Top Considering Required Size Of Platform Cabinet All Side, Top, Bottom, Salving And Backing Panel Should Be Cut From Dimensionally Stable 18 Mm +-0.7Mm Thick Having Minimum Density 550 Kgs / Cubic Meter, Screw Withal Strength As Per Is 15931 N 1200 Minimum And Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œor Equalant Approved Brand By Nau Authority. All Side, Top, Bottom, Salving And Backing Panel Should Be Assembled Using Required Size Self Drilling Philips Head Anti Corrosive Screws And Cement Solvent Adhesive As Recommended By Manufacturer Company. All Vertical Panel Distance Should Not Be More Than 700 Mm To Maintain Load Bearing Of Top Of The Platform. Projected Front Edge Of Platform Should Be Doubled By Pesting 50 Mm X 18 Mm Thick Solid / Celuka Board Strip. All Open Edge Should Be Covered Or Lipped By 18 Mm X 1Mm Thick €Œrehu†Or Equalant Brand By Edge Banding Tap Using Adhesive As Recommended By Manufacturer. The Top Of The Platform Should Be 15 Mm Minimum Thick Approved Quality And Design Granite Stone. It Should Be Place On Carcasses Using €Œaredlite†Or Equalant Adhesive. The Front And Side Edge Should Be Rounded And Polish As Directed By Engineer In Charge. The Scarting And Exposed Side Of Platform Should Be Claded With The Material Used For Top Covering Material Entire Work Should Be Furnish As Per Manufacturer Practice In True Line Level And Maintain Aesthetic Value As Well As Strength As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Kitchen / Lab Platform / Service Platform Carcasses With Pvc Laminate Top: -For Providing, Supplying & Installation Of Solid Pvc Kitchen / Lab Platform / Service Platform Carcasses With Pvc Laminate Top Considering Required Size Of Platform Cabinet All Side, Top, Bottom, Salving And Backing Panel Should Be Cut From Dimensionally Stable 18 Mm +-0.7Mm Thick Having Minimum Density 600Kgs / Cubic Meter, Screw Withal Strength As Per Is 15931 N 1200 Minimum And Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œor Equalant Approved Brand By Nau Authority. All Side, Top, Bottom, Salving And Backing Panel Should Be Assembled Using Required Size Self Drilling Philips Head Anti Corrosive Screws And Cement Solvent Adhesive As Recommended By Manufacturer Company. All Vertical Panel Distance Should Not Be More Than 700 Mm To Maintain Load Bearing Of Top Of The Platform. Projected Front Edge Of Platform Should Be Doubled By Pesting 50 Mm X 18 Mm Thick Solid / Celuka Board Strip. All Open Edge Should Be Covered Or Lipped By 18 Mm X 1Mm Thick €Œrehu†Or Equalant Brand By Edge Banding Tap Using Adhesive As Recommended By Manufacturer. The 18 Mm Thick Top Panel Of The Platform Should Be Covered With 5 Mm Thick Prelaminated Pvc Sheet Having Minimum Density 550 Kgs / Cubic Meter, Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œor Equalant Approved Brand By Nau Authority Should Be Pasted Making Groove To Cover Edge Using Cement Solvent . The Scarting And Exposed Side Of Platform Should Be Claded With The Material Used For Top Covering Material Entire Work Should Be Furnish As Per Manufacturer Practice In True Line Level And Maintain Aesthetic Value As Well As Strength As Directed By Officer In Charge., Providing, Supplying & Installation Of Solid Pvc Cupboard Filing Cabinet Carcasses: - For Providing, Supplying & Installation Of Solid Pvc Cupboard Filing Cabinet Carcasses Considering Required Size Of Cabinet Carcass All Side, Top, Bottom, Salving And Backing Panel Should Be Cut From Dimensionally Stable 18 Mm +-0.7Mm Thick Having Minimum Density 600 Kgs / Cubic Meter, Screw Withal Strength As Per Is 15931 N 1200 Minimum And Manufactured By Iso 9001 Certified Company €Œgiza†/ €Plasti Wood €Œor Equalant Approved Brand By Nau Authority. All Side, Top, Bottom, Salving And Backing Panel Should Be Assembled Using Required Size Self Drilling Philips Head Anti Corrosive Screws And Cement Solvent Adhesive As Recommended By Manufacturer Company. All Vertical Panel Distance Should Not Be More Than 700 Mm To Maintain Load Bearing And Stability Of Cabinet. If Required Steel Reinforcement Covered With 5 Mm Thick Heat Bent / Molded €Œc†Channel Should Be Provided. Projected Top Front Edge Of Cabinet And Salving Should Be Doubled By Pesting 50 Mm X 18 Mm Thick Solid / Celuka Board Strip. All Open Edge Should Be Covered Or Lipped By 18 Mm X 1Mm Thick €Œrehu†Or Equalant Brand By Edge Banding Tap Using Adhesive As Recommended By Manufacturer. The Scarting And Exposed Side Of Cabinet Should Be Claded With The Material Used For Shutter / Door Lamination. Entire Work Should Be Furnish As Per Manufacturer Practice In True Line Level And Maintain Aesthetic Value As Well As Strength As Directed By Officer In Charge., Providing, Supplying & Installation Of Filing Cabinet Carcasses Using Cement Bonded Particle Board: - For Providing And Fixing Filing Cabinet Carcasses. The Carcasses Of Cabinet Should Be Made Out Using 20 Mm And 8 Mm Thick Cement Compressed Particle Board Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority .All Top , Side, Bottom And Shelving Panel Should Be Of 20 Mm Thick Cement Compressed Particle Board Assemble Using Required Size Screw And Adhesive. All Top, Side, Bottom And Shelving Panel Should Be Assembled In True Line Level And Right Angle. Backing Panel Should Be 12 Mm Cement Compressed Particle Board Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority. At Front Side Required Size Skirting Should Be Provided. The Front Edge Of All Top, Side, Bottom And Shelving Panel Should Be Covered With 5 Thick X 20 Mm Width Teak Wood Batten Or 2 Mm Thick 20 Mm Wide Pvc Edge Banding Tap . Care Should Be Taken For Vertical Panel Installation It Should Touch To Floor For Better Load Bearing Capacity Of Platform. Each Side Of All Panel Used For Filing Cabinet Carcasses Should Be Each Side Of All Panel Used For Lab Platform Carcasses Should Be Covered With Approved Brand Liner Grade Laminate. All Exposed Side Should Be Covered With Shutter Matching 1 Mm Thick Laminate Using Quality Adhesive. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing, Supplying & Installation Of Filing Cabinet Carcasses Using Cement Bonded Prelaminated Particle Board: - For Providing And Fixing Filing Cabinet Carcasses. The Carcasses Of Cabinet Should Be Made Out Using 18 Mm And 8 Mm Thick Cement Bonded Prelaminated Particle Board Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority .All Top , Side, Bottom And Shelving Panel Should Be Of 18Mm Thick Cement Bonded Prelaminated Particle Board .All Panels Should Be Assembled Using Required Size Knock Down Type Hardware €Œebco†Or Equalant Approved Brand By Nau Authority Like Nylon Block Connector Fitting, Nylon Right Angle Connector, And Aluminum Right Angle Connector And Anti Corrosive Screw As Well As Adhesive. All Top, Side, Bottom And Shelving Panel Should Be Assembled In True Line Level And Right Angle. Backing Panel Should Be 8 Mm Cement Bonded Prelaminated Particle Board Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority. At Front Side Required Size Skirting Should Be Provided. The Front Edge Of All Top, Side, Bottom And Shelving Panel Should Be Covered With 5 Thick X 20 Mm Width Teak Wood Batten Or 2 Mm Thick 20 Mm Wide Pvc Edge Banding Tap . Care Should Be Taken For Vertical Panel Installation It Should Touch To Floor For Better Load Bearing Capacity Of Platform. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing Fixing And Supplying Conference Table Made Out From Moisture Resistant Ply As Per Design And Drawing: -For Providing Fixing And Supplying Conference Table ( Straight Line , €U†Shape , €C†Shape , Oval Shape ) Made Out From Moisture Resistant Ply All Panels Used For Conference Table Furniture ( Height 760 Mm To 830 Mm And Top Depth 600 Mm To 680 Mm. ) Should Be 18 Mm Thick Moisture Resistant Grade Isi Mark Silvi / Archid / Amul / Greenlam Or Equal Brand By Nau Authority Ply Board For All Vertical, Horizontal, And Front Panels. All Panels Will Be Assembled Using Required Screws And Marine Hyper Grade €Œfavicol†/ €Œeuro Bond†/ Equalant Brand By Nau Authority Adhesive As Per Guide Line Of Manufacturer. All Vertical And Horizontal Panels And Front Panels Should Be Covered From Both Side Approved Shade 1Mm Thick Laminate Of S.F Grade Veer / Green Lam / Timex / Amul And Equalant Brand By Nau Authority Manufactured By Iso 9000-2015 Company. As Per Design If Required All Peripheral Edge Should Be Thickened Using 50 Mm / 75 Mm / 100Mm Wide And Up To Required Thickness Using M.R. Grade Ply Panels And All Vertical Panel Should Be Doubled Up To 36 Mm . All Open Edge Should Be Covered With 2 Mm Thick Pvc Edge Bending Tape Or Seasoned Teak Wood Matching Polished Moldings. If Required Arrangement For Audio / Electrical Cable Track Should Be Arranged Under The Top And At Top €Œebco†Or Equalant Brand Cable Manager Should Be Provided. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing Fixing And Supplying Conference Table Made Out From Solid Pvc Ply As Per Design And Drawing: - For Providing Fixing And Supplying Conference Table ( Straight Line , €U†Shape , €C†Shape , Oval Shape ) Made Out From Solid Pvc Ply All Panels Used For Conference Table Furniture ( Height 760 Mm To 830 Mm And Top Depth 530Mm To 900 Mm ) Should Be 18 Mm Thick Solid Pvc / Wood Plastic Composite Panel Minimum Density 600Kgs / Cubic Meter And Outer Layer ( 0.8 Mm To 1.0 Mm ) With Density Not Less Than1400 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Mepac / Flexi Bond / Equalant Approved Brand By Nau Authority For All Vertical ( Should Be Doubled 18 Mm X 18 Mm ) , Horizontal And Front Panels. All Panels Will Be Assembled Using Required Screws And Adhesive As Per Glide Line Of Manufacturer. All Vertical And Horizontal Panels And Front Panels Should Be Covered From All Exposed Side Approved Shade 1.2Mm Thick Pvc Decorative Laminate With Density Not Less Than1400 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority Or 05 Mm Thick Solid Pvc Prelaminated Panel Minimum Density 600Kgs / Cubic Meter. As Per Design Required All Peripheral Edge Should Be Thickened Using 75 Mm / 100Mm Wide And Up To Required Thickness Using Solid Pvc Panels. All Open Edge Should Be Covered With 2 Mm Thick Pvc Edge Bending Tape. All The Panels Used For Conference Table Should Be Cladded On Both Side Using 1.2Mm Thick Pvc Decorative Laminate With Density Not Less Than1400 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority Or 05 Mm Thick Solid Pvc Prelaminated Panel Minimum Density 600Kgs / Cubic Meter If Required Arrangement For Audio / Electrical Cable Track Should Be Arranged Under The Top And At Top €Œebco†Or Equalant Brand By Nau Authority Cable Manager Should Be Provided. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing Fixing And Supplying Office Table Made Out From Moisture Resistant Ply As Per Design And Drawing: - For Providing Fixing And Supplying Office Table Made Out From Moisture Resistant Ply All Panels Used For Table Furniture ( Height 760 Mm To 830 Mm And Top Depth 600 Mm To 900 Mm. Required Drawer Will Be Paid Separately As Per Approved Rates. ) Should Be 18 Mm Thick Moisture Resistant Grade Isi Mark Silvi / Archid / Amul / Greenlam Or Equal Brand By Nau Authority Ply Board For All Vertical, Horizontal, Shutter, Drawer Fascia And Front Panels. All Panels Will Be Assembled Using Required Screws And Marine Hyper Grade €Œfavicol†/ €Œeuro Bond†/ Equalant Brand By Nau Authority Adhesive As Per Glide Line Of Manufacturer. All Vertical And Horizontal Panels And Front Panels Should Be Covered From Exposed Side Approved Shade 1Mm Thick Laminate Of S.F Grade Veer / Green Lam / Timex / Amul Or Equalant Brand By Nau Authority Manufactured By Iso 9000-2015 Company And From Inner Side 0.7 Mm Thick White Or Ivory Shade Liner Grade Laminate Veer / Green Lam / Timex / Amul Or Equalant Brand By Nau Authority Manufactured By Iso 9000-2015 Company. As Per Design If Required All Peripheral Edge Should Be Thickened Using 75 Mm / 100Mm Wide And Up To Required Thickness Using M.R. Grade Ply Panels. All Open Edge Should Be Covered With 2 Mm Thick Pvc Edge Bending Tape Or Seasoned Teak Wood Matching Polished Moldings. Required Locking Device Should Isi Mark €Œebco†/ Equalant Brand By Nau Authority With Duplicate Keys. As Per Design If Required Top Of The Glass Should Be 10Mm Thick And All Edge Of The Glass Top Should Be Rounded And Polished And The Same Will Be Paid As Per Approved Rates. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing Fixing And Supplying Office Table Made Out From Solid Pvc Ply As Per Design And Drawing: - For Providing Fixing And Supplying Office Table Made Out From Solid Pvc Ply All Panels Used For Table Furniture ( Height 760 Mm To 830 Mm And Top Depth 600 Mm To 900 Mm. Required Drawer Will Be Paid Separately As Per Approved Rates. ) Should Be 18 Mm Thick Solid Pvc / Wood Plastic Composite Panel Minimum Density 600Kgs / Cubic Meter R Manufactured By Iso 9000-2015 Company Rajshree / Giza / Mepac / Flexi Bond / Equalant Approved Brand By Nau Authority For All Vertical, Horizontal , Shutter , Drawer Fascia And Front Panels. All Panels Will Be Assembled Using Required Screws And Adhesive As Per Glide Line Of Manufacturer. All Vertical And Horizontal Panels And Front Panels Should Be Covered From Exposed Side Approved Shade 1.2Mm Thick Pvc Decorative Laminate With Density Not Less Than1400 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority Or 05 Mm Thick Solid Pvc Prelaminated Panel Minimum Density 600Kgs / Cubic Meter. As Per Design Required All Peripheral Edge Should Be Thickened Using 75 Mm / 100Mm Wide And Up To Required Thickness Using Solid Pvc Panels. All Open Edge Should Be Covered With 2 Mm Thick Pvc Edge Bending Tape. Required Locking Device Should Isi Mark €Œebco†/ Brand Approved By Nau Authority With Duplicate Keys. As Per Design Required Top Of The Glass Should Be 10Mm Thick And All Edge Of The Glass Top Should Be Rounded And Polished And The Same Will Be Paid As Per Approved Rates. Entire Work Should Be Furnished Maintaining Aesthetic Value As Directed By Authority., Providing Fixing And Supplying 12 Mm Thick Glass Top To Office Table Or As And Where Required: - For Providing Fixing And Supplying 12 Mm Thick Glass Top To Office Table Or As And Where Required The Glass Should Be 12 Mm Thick €Œashahi†/ €Œsain Goban €Œ / Equalant Brand By Nau Authority. The Glass All Edge Should Be Rounded / Sloped As Directed By Authority. The Glass Should Be Rest On Furniture Using Glass Holding Vacuumed Plug / Stainless Steel Studs Having Size Of 100 Mm / 150Mm / 200Mm., Providing, Supplying & Installation Of Computer Table / Computer Table With Cubical Using 18 Mm And 8 Mm Thick Prelaminated Cement Bonded Particle Board: - Providing And Fixing Computer Room Cubicles. The Side Panel, Top Panel And Internal Panel Should Be 18 Mm Thick Prelaminated Cement Bonded Practical Board And Backing Panel Should Be 8 Mm Thick Cement Bonded Prelaminated Practical Board. Cement Compressed Particle Board Should Be Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority The Side Panel Should Be 1200 Mm In Height And 600 Mm In Width. Required Width And 530 Mm Depth Table Top Should Be Attached Between Two Side Panels At The Height Of 765 Mm From Floor Level. The Table Should Be Supported From Bottom Using 530 Mm X 765 Mm Panel Keeping Distance Of 250 Mm Distance From One Of Side Panel. Arrangement Should Be Done Keeping 250 Mm X 765 Mm Salving Panel Between One Side Panel And Support Panel For Cpu Storage Unit. All The Side, Top , Bottom, Backing , Panel Should Be Assembled Using Required Size Knock Down Type Hardware €Œebco†Or Equalant Approved Brand By Nau Authority Like Nylon Block Connector Fitting, Nylon Right Angle Connector, And Aluminum Right Angle Connector And Anti Corrosive Screw As Well As Adhesive. If Required €Œebco†Brand Horizontally And Vertically Adjustable Cpu Stand Should Be Provided Or Equivalent And Approved Brand By Nau Authority .All Visible Side Of Panel Edges Should Be 2 Mm Thick Pvc Edge Banding Tap Using Quality Adhesive. Two Numbers Of Quality Cable Manager One At Top And One At Support Panel For Computer Cable Should Be Arranged. One Powder Coated €Œebco†Or Equivalent And Approved Brand By Nau Authority Brand Computer Key Board With Sliding Channel And Mouse Holder Should Be Placed Below Top Panel .Entre Work Should Be Done In Good Finish, Line And True Level As Directed By Engineer In Charge, Providing Fixing And Supplying 18 Mm Thick Solid Pvc Salving:- For Providing Fixing And Supplying 18 Mm Thick Pvc Salving At Existing Cupboard, Platform The Panel Should Be 18 Mm ( + / - 0.15Mm ) Thick , Density Of 600 Kgs / Cubic Meter In Required Size Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority. The Panel For Salving Should Be Installed Giving 50 Mm Wide Support Of 18 Mm ( + / - 0.15Mm ) Thick , Density Of 600 Kgs / Cubic Meter To All Three Side Of Cupboard Or Platform Using Required Size And Quantity Of Screws With Pvc Reinforcement Then Salving Panel Should Be Rested Using Screws In Required Size And Quantity Of Screws And Solvent Cement Adhesive. The Front Edge Should Be Strengthened Using 18 Mm Thick Mm ( + / - 0.15Mm ) Thick X 50 Mm X Width , Density Of 600 Kgs / Cubic Meter In Required Size Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority Front Edge Of Salving Should Be Covered With 2 Mm Thick Edge Bending Tap Using Company Recommended Practice. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Cement Bonded Particle Board Salving To Existing Platform:- For Providing And Fixing And Fixing Cement Bonded Practical Board Shelving The Board Thickness Should Be 20 / 18 Mm And Its Open Edge Should Be Covered With 20Mm X 5 Mm Wood Batten. The Shelving Board Should Be Painted From Both Sides With Two Coat Of Distemper Paint. Shelving Should Be Rested Horizontally And Vertically Using €Œc†Shape And €Œl†Shape Capping. Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Officer In Charge., Providing And Fixing Drawer To Cabinet, Cupboards, Office Table:-For Providing And Fixing Drawer To Cabinet, Cupboards, Office Table. All For Side Panel For Required Size Drawer Should Be Of Plasti Wood / Giza Brand Or Equivalent And Approved Brand By Nau Authority 18 / 20 Mm Thick Solid Pvc / Wpc Panel Having Minimum Density 500Kgs / Meter Cube And Compressive Strength 15Mp3. The Height Of Four Side Panel Of Drawer Should Be 75Mm / 150Mm / 200Mm / 300Mm.The Bottom / Base Panel Should Be Of 10 Mm Thick Plasti Wood / Giza Brand / Or Equivalent And Approved Brand By Nau Authority 18 / 20 Mm Thick Solid Pvc / Wpc Panel Having Minimum Density 600Kgs / Meter Cube And Compressive Strength 15Mp3 Or 4 Mm Thick Approved Brand Aluminum Composite Panel. All Four Side Panels And Base Panel Should Be Securely Assembled Using Quality, Approved Brand Screw, Adhesive As Per Manufacturing Company Recommended Practices. Two Nos Of Telescopic Runner Should Be Of Ebco, Hattich Or Equivalent And Approved Brand By Nau Authority Should Be Used To Attach Drawer To Cabinet, Cupboards, And Office Table. Entre Work Should Be Done In Good Finish, Line And True Level As Directed By Officer In Charge., Providing, Supplying & Installation Of Computer Table / Computer Table With Cubical Using 18 Mm And 8 Mm Thick Prelaminated Cement Bonded Particle Board: - Providing And Fixing Computer Room Cubicles. The Side Panel, Top Panel And Internal Panel Should Be 18 Mm Thick Prelaminated Cement Bonded Practical Board And Backing Panel Should Be 8 Mm Thick Cement Bonded Prelaminated Practical Board. Cement Compressed Particle Board Should Be Of &Quot;Bison&Quot; Brand Or Equivalent And Approved Brand By Nau Authority The Side Panel Should Be 1200 Mm In Height And 600 Mm In Width. Required Width And 530 Mm Depth Table Top Should Be Attached Between Two Side Panels At The Height Of 765 Mm From Floor Level. The Table Should Be Supported From Bottom Using 530 Mm X 765 Mm Panel Keeping Distance Of 250 Mm Distance From One Of Side Panel. Arrangement Should Be Done Keeping 250 Mm X 765 Mm Salving Panel Between One Side Panel And Support Panel For Cpu Storage Unit. All The Side, Top , Bottom, Backing , Panel Should Be Assembled Using Required Size Knock Down Type Hardware €Œebco†Or Equalant Approved Brand By Nau Authority Like Nylon Block Connector Fitting, Nylon Right Angle Connector, And Aluminum Right Angle Connector And Anti Corrosive Screw As Well As Adhesive. If Required €Œebco†Brand Horizontally And Vertically Adjustable Cpu Stand Should Be Provided Or Equivalent And Approved Brand By Nau Authority .All Visible Side Of Panel Edges Should Be 2 Mm Thick Pvc Edge Banding Tap Using Quality Adhesive. Two Numbers Of Quality Cable Manager One At Top And One At Support Panel For Computer Cable Should Be Arranged. One Powder Coated €Œebco†Or Equivalent And Approved Brand By Nau Authority Brand Computer Key Board With Sliding Channel And Mouse Holder Should Be Placed Below Top Panel .Entre Work Should Be Done In Good Finish, Line And True Level As Directed By Officer In Charge, Providing And Fixing Rigid 50 Mm Diameter P.V.C Drainage Pipeline:-For Providing And Fixing Rigid 50 Mm Diameter P.V.C Drainage Pipeline To Laboratory Platform With All Fixtures & Fasteners, Cost Of Solution. Required Pipe And Fittings Should Be Isi Mark &Quot;Finolex&Quot; / €Œvectus €Œ / Prince Or Equivalent And Approved Brand By Nau Authority With 6 Kg / Cm Square Pressure Bearing Capacity And Required Fittings Like Elbow , &Quot;T&Quot; , Coupler Trap Sealant Etc Of Isi Mark Having Various Size Leak Proof Joints Etc Completed . As Directed By Officer In Charge., Providing And Fixing Rigid 100 Mm Diameter P.V.C Drainage Pipeline:-For Providing And Fixing Rigid 100 Mm Diameter P.V.C Drainage Pipeline To Laboratory Platform With All Fixtures & Fasteners, Cost Of Solution. Required Pipe And Fittings Should Be Isi Mark &Quot;Finolex&Quot; / €Œvectus €Œ / Or Equivalent And Approved Brand By Nau Authority With 6 Kg / Cm Square Pressure Bearing Capacity And Required Fittings Like Elbow , &Quot;T&Quot; , Coupler Trap Sealant Etc Of Isi Mark Having Various Size Leak Proof Joints Etc Completed. As Directed By Officer In Charge., Providing And Supplying & Fixing 610 Mm X 535 Mm Laboratory Ceramic Sink:- For Providing And Supplying & Fixing 610 Mm X 535 Mm Laboratory Ceramic Sink Of Standard Company Make ( In Any Color ) To Laboratory Platform Made Out Of Cement Board / Pvc Board With All Fittings & Fixtures As Well As Required Mortar Or Adhesive ( Excluding Cost Of Pillar Cock Complete As Directed By Engineer In Charge., Providing Fixing And Supplying Solid Wood Plastic Composite 90 Mm X 45 Door Frame ( Chokhat ) :- For Providing Fixing And Supplying 90 Mm X 45 Solid Pvc Door Frame ( Chokhat ) The Chokhat Section Should Be 90 Mm X 45 Mm, Density Of 780 Kgs / Cubic Meter Minimum And Manufactured By Iso 9000-2015 Company Mapc / Giza / Flexi Bond / Jindal Gsl Equalant Approved Brand By Nau Authority. As Per Required Size Both Side And Top Frame Section Should Be Measured Cut And Joined Using Screws And Adhesive As Recommended By Company. The Door Frame Should Be Installed To The Location Using Hook, Self Expanding Screws Hole As Manufacturer Recommendation. All Gap Between Wall And Frame Should Be Filled With Silicon Or Cement Base Join Filler Compound Of Roff Or Caracol Or Brand By Nau Authority. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing Fixing And Supplying Solid Wood Plastic Composite 100 Mm X 50 Door Frame ( Chokhat ) :- For Providing Fixing And Supplying 100 Mm X 50 Mm Solid Pvc Door Frame ( Chokhat ) The Chokhat Section Should Be 100 Mm X 50 Mm, Density Of 780 Kgs / Cubic Meter Minimum And Manufactured By Iso 9000-2015 Company Mapc / Giza / Flexi Bond / Jindal Gsl Equalant Approved Bran By Nau Authority D. As Per Required Size Both Side And Top Frame Section Should Be Measured Cut And Joined Using Screws And Adhesive As Recommended By Company. The Door Frame Should Be Installed To The Location Using†Hook, Self Expanding Screws Hole As Manufacturer Recommendation..All Gaps Between Wall And Frame Should Be Filled With Silicon Or Cement Base Join Filler Compound Of Roff Or Caracol. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing Fixing And Supplying Wood Plastic Composite Solid Section Double Rabbet Door Fram120 Mm X 50 Mm ( Chokhat ) ) :- For Providing Fixing And Supplying 120 Mm X 50Mm Double Rabbet Wpc Door Frame ( Chokhat ) The Chokhat Section Should Be 120 Mm X 50 Mm, Density Of 780 Kgs / Cubic Meter Minimum And Manufactured By Iso 9000-2015 Company Mapc / Giza / Flexi Bond / Jindal Gsl Equalant Approved Brand By Nau Authority. As Per Required Size Both Side And Top Frame Section Should Be Measured Cut And Joined Using Screws And Adhesive As Recommended By Company. The Door Frame Should Be Installed To The Location Using†Hook, Self Expanding Screws Hole As Manufacturer Recommendation..All Gaps Between Wall And Frame Should Be Filled With Silicon Or Cement Base Join Filler Compound Of Roff Or Caraco / Brand By Nau Authority. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing , Supplying & Installation Of Pvc Chokhat :- For Providing And Fixing Chokhat .The Section Used For Chokhat Should Be &Quot; €Œsintex†Or €Œpoly Wood €Œor Equivalent And Approved Brand By Nau Authority Poly Vinyl Chloride Extruded Section Having Size Of 53 Mm X 60 Mm / 42 Mm X 50 Mm. Entire Section Used For Chokhat Should Be Reinforced Using Seasoned Wood. For Assembling Of Chokhat Solid Heavy Density Polymeric Corner Having Size Of 200 Mm X 85 Mm X 25 Mm Should Be Used At Two Corner And Should Be Fasten Using Required Number Of Screws At Side And Top To Fix Hinge At Side Of Chokhat Section And To Handle Or Knob With Accessory Required Reinforcement Should Be 15 Mm X 300 Mm Solid Heavy Density Polymeric Piece. All Gaps Should Be Joined Using &Quot;Thanga Bond†Adhesive Or Equivalent And Approved Brand By Nau Authority And Daw Corning Brand Silicon. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing, Supplying & Installation Of 24 Mm Thick Pvc Laminated Door: - For Providing, Supplying & Installation Of Pvc Laminated Door All The Profile Used For Door Fabrication Should Be €Œsintex†Or €Œpoly Wood €Œor Equivalent And Approved Brand By Nau Authority Heavy Grade Not Economy Series . Both The Wall Thickness Of Infill Panel Must Be 1.8 Mm Minimum .The Outer Frame Of Door Should Be Having Size 24Mm 44Mm / 24 Mm X 60Mm / 24 Mm X 85 Mm / 24 Mm X 110 Mm Section. For Assembling Of Outer Frame Solid Heavy Density Polymeric Corner Having Size Of 200 Mm X 85 Mm X 25 Mm Should Be Used At Four Corners. The Infill Panel Should Be 20Mm Thick Pre Laminated Poly Vinyl Chloride Multi Chambered Hollow Plastic Section In One Piece Only. To Fix Hinge At Side Of Shutter Frame And To Handle Or Knob With Accessory Required Reinforcement Should Be 15 Mm X 300 Mm Solid Heavy Density Polymeric Piece. Three Nos Or Required Number Of Hinges Should Be Of 75 Mm X 19 Mm X 19 Mm Stainless Steel With Quality Zinc Plated Screw Having Size Of 16 Mm X 06 Mm Or Required Size In Required Quantity. Two Number Of Approved Quality 125 Mm X 15 Mm Stainless Steel Handle, Two Nos Of S.S. Aldraf Having Size Of 200 Mm X 10Mm Should Be With All Required Accessory. Care Should Take While Installing Hardware All Screws Should Be Through In Reinforcement. All Gap And Panel And Channel Should Be Joined Using &Quot;Thanga Bond†Adhesive. Or Equivalent And Approved Brand By Nau Authority Entire Work Should Be Done In True Line Level And Maintain Esthetic Value As Directed By Engineer In Charge., Providing And Fixing Solid Core Wooden Flush Door With Both Side Laminate: ( Approved Brand By Nau Authority ) - The Flush Door Should Be 30 Mm Thick. Flush Doors Should Be Of Selected Seasoned Timber, Pressed At High Pressure With Phenol Formaldehyde Resin Under The Cross Bonding Process. Flush Doors Should Be Dimensionally Stable, Termite Resistant, And Moisture-Proof. Flush Door Density Should Be Minimum 600 Kgs / Meter Cube. Flush Door Moisture Content Should Not Be More Then 8To 10 %. Screw Holding Strength Should Be ≫225 Kgs. Nail Holding Strength ≫ 100 Kgs. The Flush Door Should Be Cladded From Both Side Quality 1 Mm Thick Laminate Of Approved Brand Timex / Greenlam / Marino / Veer Or Equalant And Design Using Marine Grade Adhesive. If Required Openings For Vision Panel Or Louvers Should Be Provided. Each Door Should Be Installed Using 2 Nos Of ( 8Mm X 200Mm ) Stainless Steel Aldraf , Stainless Steel Door Stay , Stainless Steel Hinge 4 Nos / Door Having Size Of 150 Mm X 25 Mm X 25 Mm X 3Mm .Stainless Steel Handle Having Size Of 200 Mm X 5 Mm X 3 Mm. All Work Should Carry Out With Good Finish And In True Line As Directed By Engineer In Charge., Providing Fixing And Supplying 30 Mm Thick High Strength Pvc With Iron Reinforcement Both Side Prelaminated Solid Pvc Door Shutter: - For 30 Mm Thick High Strength Pvc With Iron Reinforcement Both Side Prelaminated Solid Pvc Door Shutter 5 Mm ( + / -0.15 Mm ) Thick Solid Pvc Prelaminated Panel And 15 Mm Thick Solid Pvc Panel Should Have Minimum Density 600Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Equalant Approved Brand By Nau Authority. Both Side Of Top Bottom And Lock Rail Should Be 19 Gauges Mild Steel Tube Having Size Of 19 Mm X 19 Mm For Stiles, Top And Bottom Rails. Mild Steel Frame Shall Be Having One Coat Of Steel Primers Of Approved Brand. 20 Mm Thick Multy Chambered Hollow Pvc Panel Having Wall Thickness Of 1 Mm Minimum And Reinforced With Solid Pvc Batten In Required Size Randomly Using Cynoacrylate / Solvent Cement Adhesive. Both Side Of Hollow Pvc Panel Should Be Covered With 5 Mm Thick Pvc Prelaminated Panels Using Cement Solvent Adhesive As Recommended By Manufacturer Company. All The Four Edge Of Door Should Be Covered With 15 Mm Thick And 20 Mm Wide Pvc Batten. Using Pvc Cement Solvent Adhesive. Door Lipped Edge Should Be Covered With Pvc Ink Of Matching Color. 20 Mm Thick Pvc Reinforcement Must Be Provided For Lock Rail At Required Height. The Door Should Be Installed To Frame Using Three Nos Of 100 Mm X 25 Mm X 25 Mm X 3Mm Stainless Steel Hinge Using Manufacturer Specified Screws In Required Quantity. Two Number Of Approved Quality 125 Mm X 15 Mm Stainless Steel Handle, Two Nos Of S.S. Aldraf Having Size Of 200 Mm X 10Mm Should Be With All Required Accessory With Each Door. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing Fixing And Supplying 30 Mm Thick Three Layer Solid Pvc Door: - For Providing Fixing And Supplying 30 Mm Thick Three Layer Solid Pvc Door The Door Panel Should Be 30 Mm Thick Coextruded Three Layered Rigid Pvc Foam Board Having Minimum Density 600Kgs / Cubic Meter And Outer Layer ( 0.8 Mm To 1.0 Mm ) With Density Not Less Than1400 Kgs / Cubic Meter Manufactured By Iso 9000-2015 Company Rajshree / Giza / Mepac / Flexi Bond / Equalant Approved Brand By Nau Authority. . All The Four Edge Of Door Should Be Covered With 2 Mm Thick And 30 Mm Wide Pvc Edge Banding Tape Using Pvc Cement Solvent Adhesive. The Door Should Be Installed To Frame Using Three Nos Of 100 Mm X 25 Mm X 25 Mm X 3Mm Stainless Steel Hinge Using Manufacturer Specified Screws In Required Quantity. Two Number Of Approved Quality 125 Mm X 15 Mm Stainless Steel Handle, Two Nos Of S.S. Aldraf Having Size Of 200 Mm X 10Mm Should Be With All Required Accessory With Each Door. Entire Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge., Providing And Fixing Fully Glazed Color Anodized / Powder Coated Aluminum 2 Track Sliding Window: - Approved Quality ( Jindal / Hindalco / National Or Equivalent And Approved Brand By Nau Authority ) Made From Color Anodized Aluminum Sections ( With Color Anodized Coated ) And Fully Glazed Panels Of 5Mm Thick Plain Glass Or Color Glass Ashai, Sain Goban Or Equivalent And Approved Brand By Nau Authority , Necessary Fixtures & Fastening, Locking Arrangement Etc. Complete At All Levels As Per The Manufacturers Specification Having Two Track Outer Frame Comprising Of Bottom Section 20830 ( 61.85 X 31.75 X 1.5Mm, Wt. 0.909 Kg / Rmt. ) . And Top / Sides -20829 ( 61.85 X 31.75 X 1.5Mm, Wt. 0.784 Kg / Rmt. ) . The Sliding Shutter Frame Shall Be Made Out Of Top Section 20736 ( 40.00 X 18.00 X 1.55Mm, Wt. 0.547 Kg / Rmt. ) . Bottom Section 20750 ( 52.00 X 18.00 X 1.56Mm, Wt. 0.651 Kg / Rmt. ) . Handles / Sides Section 20738 ( 40.00 X 18.00 X 1.55Mm, Wt. 0.547 Kg / Rmt. ) . Inter Lock Section 20737 ( 40.00 X 27.00 X 1.45Mm, Wt. 0.607 Kg / Rmt. ) . Including Wolf, Virgin Transparent Rubber Gasket & Provided With Extruded Re-Presence Weather - Strip Of A Size To Make The Window Whether Tight H.D.P. Ant Ratting Pieces At The Top & Bottom To Control Vibrations Due To Wind Etc Complete, As Directed By Engineer-In-Charge & Architect As Per Detail Drawings., Providing And Fixing Fully Glazed Color Anodized / Powder Coated Aluminum 3 Track Sliding Window: - Of Approved Quality ( Jindal / Hindalco / National Or Equivalent ) Made Or Equivalent And Approved Brand By Nau Authority From Color Anodized Aluminum Sections ( With Color Anodized Coated ) And Fully Glazed Panels Of 5Mm Thick Plain Glass Or Color Glass Ashai, Sain Goban Or Equivalent And Approved Brand By Nau Authority , Necessary Fixtures & Fastening, Locking Arrangement Etc. Complete At All Levels As Per The Manufacturers Specification ( As Per Is 1949 ) Having Three Track Outer Frame Comprising Of Bottom Section 20832 ( 92.00 X 31.75 X 1.5Mm, Wt. 1.248 Kg / Rmt. ) . And Top / Sides -20831 ( 92.00 X 31.75 X 1.5Mm, Wt. 1.060 Kg / Rmt. ) . The Sliding Shutter Frame Shall Be Made Out Of Top Section 20736 ( 40.00 X 18.00 X 1.55Mm, Wt. 0.547 Kg / Rmt. ) . Bottom Section 20750 ( 52.00 X 18.00 X 1.56Mm, Wt. 0.651 Kg / Rmt. ) . Handles / Sides Section 20738 ( 40.00 X 18.00 X 1.55Mm, Wt. 0.547 Kg / Rmt. ) . Inter Lock Section 20737 ( 40.00 X 27.00 X 1.45Mm, Wt. 0.607 Kg / Rmt. ) . Including Woolf, Virgin Transparent Rubber Gasket & Provided With Extruded Re-Presence Weather - Strip Of A Size To Make The Window Whether Tight H.D.P. Ant Ratting Pieces At The Top & Bottom To Control Vibrations Due To Wind Etc Complete, As Directed By Engineer-In-Charge & Architect As Per Detail Drawings., Providing And Fixing Color Anodized Aluminum Sliding Window Section Having Mosquito Net:- For Providing And Fixing Color Anodized Aluminum Section Should Be Of Banco / Jindal / Hindalco Or Equivalent Isi Brand Approved By Nau Authority Anodized Color Window Section. Two Track Bottom Thickness 1.20Mm Of Having Size 31.75Mm X 61.85Mm Of Approx Weight 0.700Kg Rmt And Top Two Track Or Vertical Two Track Thickness 1.30Mm Of Having Size 31.75Mm X 61.85Mm Of Approx Weight 0.655Kg Rmt. Shutter Frame Section Handle Series Minimum Thickness 1.20Mm Of Having Size 18Mm X 40Mm Of Approx Weight 0.430Kg Rmt And Shutter Inter Lock Vertical Series Thickness 1.2Mm Of Having Size 27Mm X 40Mm Of Approx Weight 0.510Kg Rmt And Shutter Top & Bottom Series Thickness 1.20Mm Of Having Size 18Mm X 40Mm Of Approx Weight 0.420Kg Rmt And Sliding Shutter Arrangement Having Good Quality Isi Brand Runner Bearing With Locking Arrangement For Complete Fitting. Two Shutter Of Mosquito Ss 304 Grade Jali Of Wire ( Screen ) ( 20X30 Gauge ) 8% Nickel Of Approx Weight 0.685 Kg / Smt Isi Brand With Complete Fitting Four Edge Side Good Quality Pvc Buffer Should Be Of 10Mmx10mm Size. The Peripheral Gap Should Be Sealed By Water Proof Silicon Seal. Installation Should Be Done By Stainless Steel Screw ( Of Required Size ) And Wall Plug ( Of Required Size ) . All The Work Will Be Carried Out With Good Finishing And Line Level As Directed By Authority, Providing And Fixing Supplying Hydraulic Floor Springs:- For Providing And Fixing Double Action Hydraulic Floor Springs Of Approved Brand ( Ebco / Ozone / Every Day / 5M Or Equivalent And Approved Brand By Nau Authority ) Conforming To Is: 6315 For Aluminum Doors. Rate To Include Cutting Of Floors As Required, Embedding In Floors And Cover Plates, Chipping, Finishing, Repairing Etc Complete As Directed By Engineer In Charge., Providing And Fixing Round / Handle Lock :- Providing & Fixing Godrej Or Equivalent And Approved Brand By Nau Authority Six Lever Lock ( Cylindrical / Round Head ) Including All Necessary Hardware Etc All Complete As Directed By Engineer In Charge, Providing , Fixing And Supplying Fan Hook: - Providing & Fixing Ms Fan Hooks With 16 Mm Diameter Ms Bar Bent To Shape With Hooked Ends In Rcc Slab During Lying Including Painting The Exposed Portion, Providing , Fixing Gi Steel Work For Window Grill And Prefab Structure :- Welded Steel Structure Of G.I.Steel For Prefab And Window Grill Supplying, Erecting And Fixing In Position Prefabricated Structures Using Structural Steel Tube Sections, Plates, Flats, Square Bars, Rods Etc. At All Elevations Using Structural Steel Sections Including Cutting, Welding Or Bolting, Supply Of Bolts / Nuts / Washers Etc., Complete As Per Drawings Including Surface Preparation And Applying One Coat Of Zinc Phosphate Primer Before Erection And Two Coats Of Synthetic Enamel Paint As Per Specification After Erection And All Materials And Labor Complete, Providing , Fixing M.S Steel Work For Window Grill And Prefab Structure :- Welded Steel Structure Of G.I.Steel For Prefab And Window Grill Supplying, Erecting And Fixing In Position Prefabricated Structures Using Structural Steel Tube Sections, Plates, Flats, Square Bars, Rods Etc. At All Elevations Using Structural Steel Sections Including Cutting, Welding Or Bolting, Supply Of Bolts / Nuts / Washers Etc., Complete As Per Drawings Including Surface Preparation And Applying One Coat Of Zinc Phosphate Primer Before Erection And Two Coats Of Synthetic Enamel Paint As Per Specification After Erection And All Materials And Labor Complete, Providing, Supplying & Installation Of Perforated Cutlery Kitchen Basket ( 370 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Perforated Cutlery Kitchen Basket The Kitchen Basket Should Be 201 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be Perforated S.S.201 Grade Sheet. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand Approved By Nau Authority 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Perforated Cutlery Kitchen Basket ( 420 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Perforated Cutlery Kitchen Basket The Kitchen Basket Should Be 201 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be Perforated S.S.201 Grade Sheet. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand Approved By Nau Authority 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Perforated Cutlery Kitchen Basket ( 470 Mm X 520 Mm X 100 Mm ) :- For Providing Fixing Perforated Cutlery Kitchen Basket The Kitchen Basket Should Be 201 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be Perforated S.S.201 Grade Sheet. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand Approved By Nau Authority 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Perforated Cutlery Kitchen Basket ( 520 Mm X 520 Mm X 100 Mm ) :- For Providing Fixing Perforated Cutlery Kitchen Basket The Kitchen Basket Should Be 201 Grade Steel Nickel Chromium Platting €Œever Shine†Equalant Brand Approved By Nau Authority Next Model Having Size Of 521 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be Perforated S.S.201 Grade Sheet. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand Approved By Nau Authority 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Thali / Plate Kitchen Basket ( 370 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Thali / Plate Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X200 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Thali / Plate Kitchen Basket ( 420 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Thali / Plate Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X200 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Thali / Plate Kitchen Basket ( 470 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Thali / Plate Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X200 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Thali / Plate Kitchen Basket ( 520 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Thali / Plate Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520 Mm X 485 Mm X200 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 370 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X200mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 420 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X200mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 470 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X200mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 520 Mm X485 Mm X 200 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520 Mm X 485 Mm X200mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 370 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco €Œor Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 420 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco €Œor Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 470 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco €Œor Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 520 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco €Œor Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 370 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 420 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 470Mm X485 Mm X 100 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Plain Basket Kitchen Basket ( 520Mm X485 Mm X 100 Mm ) :- For Providing Fixing Plain Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer., Providing, Supplying & Installation Of Cup Saucer Basket ( 370 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Cup Saucer Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Cup Saucer Basket ( 420 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Cup Saucer Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Cup Saucer Basket ( 470 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Cup Saucer Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Cup Saucer Basket ( 520 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Cup Saucer Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 370 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 420Mm X485 Mm X 150 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 470Mm X485 Mm X 150 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 520 Mm X485 Mm X 150 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œâ€Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520 Mm X 485 Mm X150 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 370 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 370 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 420Mm X485 Mm X 100 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 420Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 470Mm X485 Mm X 100 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 470 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing, Supplying & Installation Of Partition Basket Kitchen Basket ( 520 Mm X485 Mm X 100 Mm ) :- For Providing Fixing Partition Kitchen Basket The Kitchen Basket Should Be 202 Grade Steel Nickel Chromium Platting €Œever Shine†Next Model Or Equalant Brand And Model Approved By Nau Authority Having Size Of 520 Mm X 485 Mm X100 Mm. The Main Structure Of Basket Should Be 5 Mm Round Steel S.S. 202 Grade Nickel Chromium Plated And Secondary Bottom Structure Should Be S.S.201 Grade 2.7 Mm Round Bar. The Basket Should Be Installed To Existing Stone Kitchen Platform Using Required Sized Seasoned Teak Wood Packing, €Œever Shine†€Œebco†Or Equalant Brand 510 Mm Telescopic Channel, Nylon Plug And Required Size Anti Corrosive Screws. . Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer, Providing , Supplying And Installation 12-16 ( Id -Od ) Water Supply Pipe Line: - Providing And Fixing 12-16 ( Id -Od ) Water Supply Line Using Multi-Layer Composite Pipe Of €Œkitec†/ Vectus Or Equivalent And Approved Brand By Nau Authority With Composite Fittings Like Female Thread Connector , Female Tee, Female Elbow , Male Thread Connector, , Reducing Tee Equal Tee Having Various Diameter For Laboratory And Solar Water Heating System, As Directed By Engineer In Charge., Providing , Supplying And Installation 16-20 ( Id -Od ) Water Supply Pipe Line: - Providing And Fixing 16-20 ( Id -Od ) Water Supply Line Using Multi-Layer Composite Pipe Of €Œkitec†/ Vectus Or Equivalent And Approved Brand By Nau Authority With Composite Fittings Like Female Thread Connector , Female Tee, Female Elbow , Male Thread Connector, , Reducing Tee Equal Tee Having Various Diameter For Laboratory And Solar Water Heating System, As Directed By Engineer In Charge, Providing , Supplying And Installation 20-25 ( Id -Od ) Water Supply Pipe Line: - Providing And Fixing 20-25 ( Id -Od ) Water Supply Line Using Multi-Layer Composite Pipe Of €Œkitec†/ Vectus Or Equivalent And Approved Brand By Nau Authority With Composite Fittings Like Female Thread Connector , Female Tee, Female Elbow , Male Thread Connector, , Reducing Tee Equal Tee Having Various Diameter For Laboratory And Solar Water Heating System, As Directed By Engineer In Charge, Providing , Supplying And Installation 25-32 ( Id -Od ) Water Supply Pipe Line: - Providing And Fixing 25-32 ( Id -Od ) Water Supply Line Using Multi-Layer Composite Pipe Of €Œkitec†/ Vectus Or Equivalent And Approved Brand By Nau Authority With Composite Fittings Like Female Thread Connector , Female Tee, Female Elbow , Male Thread Connector, , Reducing Tee Equal Tee Having Various Diameter For Laboratory And Solar Water Heating System, As Directed By Engineer In Charge, Providing Supplying And Installing Solar Water Heating System:- The System Should Be Mnre ( Ministry Of New And Renewable Energy ) Approved Iso 9001-2000 Certified €Œfarm Sun €Œor Equivalent And Approved Brand By Nau Authority The System Should Be Vacuum Tube Non Pressurized Type Direct Tube Injection Type. The Hot Water Storage Tank Should Be Made Out From 3 Mm Thick Epoxy Coated Galvanized Iron Materials Using Tig Welding Process .The Outer Cladding Material Should Be Pre Painted Galvanized Iron Steel Material. The Insulation Will Be Cfc Free Polyurethane Foam. Required No ( 12 Nos Of Tube / 100 Lit Capacity Having Size Of 47 Mm Outer Diameter, Inner Diameter Of 37Mm And 1800 Mm Length Up To 300 Lpd Capacity And 27Nos / 500 Lpd Having Size Of 70 Mm Outer Diameter, Inner Diameter Of 54 Mm And 2100 Mm Length ) Of Solar Collector Glass Tubes Containing Two Layers And Air Evacuated Having 1.6 Mm Glass Thickness Outer Diameter Of Made Out From Borosilicate 3.3 Glass Material With Absorptive Coating Of Graded Al-N / Al Vacuum ≪5*10⫬⫬^-3 Pa With Strength 0.8 Mpa. Epdm Gasket Having Capacity To With Stand 125 Degree Temperature To Insert Tube In Hot Water Collection Tank Will Be Approved Quality. The Stand Of System Will Be Press Pre Coated Galvanized Iron Steel With Necessary Fittings. For Electrical Back Up Will Be 2 Kwa Immersion Type Inserted In Hot Water Storage Tank. Required No Return Valve And Stop Cock Should Be Part Of System. Water Supply Line And Hot Water Discharge Line Will Be Measured And Paid Separately. Entire Installation Work Should Be Done In True Line Level And Maintain Aesthetic Value As Directed By Engineer In Charge, Providing & Supplying Of Folding Bed :- Folding Bed Should Be Of Supreme Ind. Ltd / Nilkamal Or Any Equivalent Brand & Folding Type.Basic Structure Of Bed Should Be Of M.S. Hollow Round Section With Higher Quality Powder Coating.Top Or Sheet Of Bed Should Be Of 03 Layered Blow Mould Plastic.Size Of Bed Should Be 3.00 Ft ( 0.91Mt ) Width & 6.50 Ft ( 1.98 Mt ) Length. As Directed By Engineer In Charge
|