Quotation are invited for Firefighting Pump Controller Replacement Fps Firefighting Pump Control 1032604721 1 ITEM-00001 REPLACEMENT OF FPS PUMP CONTROLLER ELECTRIC AT HSPL 132SUBSTATION:SAP WORK ORDER: 521945530ISSUE:EXISTING ELECTRIC FIRE PUMP CONTRO LLER IS NOT FUNCTIONING. PRELIMINARYASSESSMENT INDICATES FAILURE OF THE I/O BOARD. THE CONTROLLER IS ANOBSOLETE MODEL, AND SPARE PAR TS ARE NOT READILY AVAILABLE.EXISTING CONTROLLER DETAILS1. MAKE: TORNATECH, CANADA2. MODEL: GPY-400/150/3/50; SERIAL NO:Z40432; 200 9SCOPE OF WORKSUPPLY, INSTALLATION, TESTING, AND COMMISSIONING OF A NEW ELECTRICFIRE PUMP CONTROLLER TO REPLACE THE EXISTING DEFECTI VE CONTROLLER.NEW CONTROLLER SUPPLIED BY VENDOR SHALL BE DEWA-TP APPROVED ANDSHALL MATCH THE EXISTING PUMP MOTOR RATINGS AND SYSTEM OPERATINGREQUIREMENTS.NEW CONTROLLER REQUIRED: #TORNATECH UAE ; MODEL: GPY-400/150/3/50; TYPE: WYE-DELTA OPEN 1 AU TRANSITION;UL FM; DEWA SPEC; 400V ;150 HP ; NEMA TYPE 4; OPTIONS A16D,C01,C10,C14,C15,CX001,CX002,CX019,D11 AND D39; RATED FOR55 DEG CELSIUS#VENDOR SHALL CONDUCT A SITE SURVEY, IF REQUIRED, TO VERIFY DIMENSIONS,CABLE ENTRIES, CONTROLLER COMPATIBILITY, PIPING ARRANGEMENTS, ANDINSTALLATI ON REQUIREMENTS. NO VARIATION ORDER SHALL BE ENTERTAINEDDUE TO INADEQUATE SITE ASSESSMENT.VENDOR SHALL SUBMIT MATERIAL SUBMITTAL AND METHOD STATEMENT FORDEWA APPROVAL PRIOR TO EXECUTION:VENDOR SHALL COMPLETE AND SUBMIT THE DEWA EQUIPMENT CHANGETEMPLATE ALONG WITH ALL REQUIRED TECHNICAL DETAILS FOR SAP ASSETUPDATING.ANY MODIFICATION REQUIRED TO THE EXISTING SENSING LINE PIPING,PRESSURE SENSING ARRANGEMENT, CABLE TERMINATIONS, CONDUIT ENTRIES,MOUNTING ARRANGEMENTS, OR INTERFACING SHALL BE INCLUDED WITHIN THESCOPE.EXISTING CO NTROLLER SHALL BE CAREFULLY DISMANTLED AND REMOVED.VENDOR SHALL INSPECT THE EQUIPMENT REMOVED AND IDENTIFY ANY REUSABLEOR SALVAGEABL E SPARE PARTS.DETAILED LIST OF RECOVERABLE SPARES SHALL BE SUBMITTED TO DEWA.RECOVERABLE ITEMS SHALL BE TRANSPORTED AND HANDED OVER TO DEWACENTRAL STORES FOR MRR PROCESSING.TRANSPORTATION, HANDLING, LOADING, UNLOADING, AND DOCUMENTATIONSHALL BE UNDER VENDOR SCOPE. DISPOSAL/SCRAPPING OF NON-REUSABLE ENCLOSURE AND COMPONENTSSHALL BE VENDOR SCOPE IN ACCORDANCE WITH APPLICABLE REGULATIONS.1 FPS FIREFIGHTING PUMP CONTROLLER REPLACEMENT STANDARD TERMS & CONDITIONS 1) Prices should be DDP delivery duty paid at DEWA stores. 2) Quotation to be submitted only in local currency U.A.E Dirhams 3) DEWA Standard payment terms is 30 days credit from the date of acceptance of material 4) No DEWA staff or his or her relatives up to third degree should have ownership or partnership in your company, and your participation in DEWA tenders / RFQs should not constitute a Conflict or perceived Conflict of Interest. Supplier Registration: https://srm.dewa.gov.ae/irj/portal/anonymous/regis Tender Link : https://srm.dewa.gov.ae/sap/opu/odata/sap/ZSRM_RFX_REG_BID_SRV/AttachmentSet(2332602395)/$value
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 118600980
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.