1) Laying A Thick Polyurethane Surface. Min. 13 Mm (6,446.48 M2 Track + Semi-Circle Behind The Goals, Inrun To The Long Jump) With Line Painting. The Track Consists Of A 6-Lane Circular Track With A Length Of 400 M And A 6-Lane Straight Track. The Inner Radius Of The Curve Is 36.5 M. The Radius Is Measured To The Outer Edge Of The Inner Curb - I.E. The Left Edge Of The Track. The Straight Track For The 100 M And 110 M Hurdles Runs Has A Common Section With The Circular Track. The Total Length Of The Straight Track Is 130M. The Surface Should Have Functional Characteristics That Fall Within The Ranges Described Below:1. Thickness: Min 13 Mm2. Tensile Strength: 0.50 – 0.99 (Mpa)3. Tensile Elongation: 40 – 64 (%)4. Friction Coefficient: 50 – 65 (Trrl)5. Vertical Deformation 23 Degrees C: 1.7 – 2.2 (Mm)6. Shock Absorption At 23 Degrees C: 35 – 40 (%)2) Delivery And Assembly Of Double-Row Cabins For 14 Players. Two-Row Cabin For Reserve Players With A Platform - Solid Polycarbonate Cover, With A Powder-Coated Steel Supporting Structure, Covered With Solid Polycarbonate Plates, 3 Mm Thick. The Cabin Is Equipped With A Cover For The Front Roof Profile, Made Of Foam Covered With Pvc Material, With An Inscription. The Steel Cabin Platform, Protected Against Corrosion By Hot-Dip Galvanizing, Is Finished With Artificial Grass, Aluminum Checkered Sheet And Decorative Aluminum Angle, Aluminum Finishing Of The Elements, Plastic Seats With Backrest - 2 Pcs.3) Ball Catchers 7 M High, 50 M Long, Mounted On Steel Structures, External With Nets - 2 Pcs. Main Elements Ball Catchers Are Steel Poles Made Of Closed Tubular Elements. Protected Against Corrosion By Powder Coating. The Filling Of The Ball Traps Are Polypropylene Nets With A Mesh Size Of 8X8 Cm And A Thickness Of 5Mm. The Nets Are Stretched On Steel Cables Fastened Between The Poles. It Is Recommended To Use A Mesh With A Thickness Of Not Less Than 5 Mm To Ensure Its Adequate Strength. It Must Withstand Not Only The Impact Of The Ball, But Also The Possible Impact Of A Player Running Into The Ball Catcher. The Barrier Posts Should Be Placed In Concrete Foundations With A Minimum Volume Of 0.07 M3, After Cutting Out The Bituminous Mass In The Place Of Foundation. The Depth Of The Fence Depends On The Ground Frost Zone In Accordance With The Pn-81/B-03020 Standard, But Due To Statics, To A Depth Of Not Less Than 1.0 M Below The Ground Level. Installation Of Ball Catchers According To The Drawings Of The Land Development Design And The Architectural And Construction Design. 4) Delivery And Assembly Of The Electronic Scoreboard, Dimensions 300 X 150 X 7 Cm (+/- 10%) According To The Opz Scoreboard - Annex No. 7 - Detailed Design. A Detailed Description Of The Subject Of The Order (Annex No. 7 To The Swz) Is Specified In The Design Documentation Attached To This Swz And Sst, Bill Of Quantities And Important Provisions Of The Contract.
Contact Information
Address
Gmina Pruszcz,Pruszcz,86-120,Kujawsko-Pomorskie,Pl618 - Świecki
Contact No.
0525624323
Email
zp@pruszcz.pl
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 111832831
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.