Control Precicontrol Tumor Marker. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: Set Precicontrol Tumor Marker (Set Of Control Serums) Designed To Control The Quality Of Elecsys Tests By The Immunochemical Method On Elecsys And Cobas E Analyzers. Control Material Precicontrol Tumor Marker Is A Lyophilized Control Serum Based On Serum Human Blood With A Concentration Of 2 Clinically Significant Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunestes. Reagents - Working Solutions (Man). To Prepare The Control Material, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of The Components In Dissolved Control Serum: At -20 ° C (± 5 ° C) 1 Month Or At 2-8 ° C 2 Weeks, On Board The Analyzers At 20-25 ° C To 5 Hours. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Isds. The Reagents For The Cobas Pro/Pure Analyzer .. Purpose Of The Precicontrol Isd Control Materials Set Is Used To Control The Quality Of The Corresponding Elecsys Immunitest Tests On Cobas Pro Immunochemical Analyzers. The Theoretical Substantiation Precicontrol Isd Is A Lyophilized Control Material Based On A Human Blood In 3 Ranges Of Concentrations. Control Materials Are Used To Monitor The Accuracy And Precision Tests Of Elecsys Cyclosporine, Elecsys Tacrolimus And Elecsys Sirolimus. Reagents - Working Solutions ▪ Pc Isd 1: 1 Bottle, For Preparing 3.0 Ml Of Control Blood ▪ Pc Isd 2: 1 Bottle, For Preparing 3.0 Ml Of Control Blood ▪ Pc Isd 3: 1 Bottle, For Cooking 3.0 Ml Of Control Blood. Storage And Stability Are Stored At 2 8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of Dissolved Control Materials: At –20 ° C (± 5 ° C) 28 Days (Only Single Freezing Is Allowed) At 2 8 ° C 7 Days At 20,25 ° C 5 Days. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Multi Marker. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: The Precicontrol Multimarker Set Is Designed To Control Quality Listed Immunestes On Elecsys And Cobas E Analyzers. The Precicontrol Multimarker Set Contains A Lyophilized Control Serum Based On A Blood Sewer Matrix In Two Concentration Ranges. Controls Are Used For Monitoring The Accuracy And Reproduction Of Elecsys Immunestes. Reagents - Working Solutions: ▪ Pc Mm1: 3 Bottles, Each 2.0 Ml Of Control Serum ▪ Pc Mm2: 3 Bottles, Each In 2.0 Ml Of Control Serum. To Prepare The Control Material, Add Distilled Water. Storage And Stability Store At 2-8 ° C. Liophilized Control Serum Is Stable To The Specified Expiration Date. The Stability Of All Components In The Dissolved Control Serum: At - 20 ° C (± 5 ° C) 31 Days Or At 2-8 ° C 72 Hours, On Board The Analyzers At 20-25 ° C Up To 5 Hours. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Precicontrol Anti-Hcv Control. Reagents For The Cobas Pro/Pure Analyzer .. Purpose: Precicontrol Anti -Hcv Control Material Is Used To Control The Quality Of The Elecsys Anti -Hcv Ii Immunothelates On Cobas E Immunochemical Analyzers. Precicontrol Anti -Hcv Is A Ready -To -Use Serum Based On A Human Blood Serum In A Negative And Positive Concentration Range. Control Materials Are Used To Monitor Accuracy Elecsys Anti -Hcv Ii Immunestet. Reagents - Working Solutions: ▪ Pc A -Hcv1: 8 Bottles, 1.3 Ml Of Control Serum In Each. Human Blood Serum Negative In Antibodies To The Hepatitis C Virus; Conservice. The Target Range For The Threshold Value Index: 0-0.3 ▪ Pc A -Hcv2: 8 Bottles, 1.3 Ml Of Control Serum In Each Antibodies To The Hepatitis C Virus (Human) In A Human Blood Serum; Conservice. The Target Value For The Threshold Index: Anti -Hcv Ii: Approximately 4. Control Materials Are Supplied Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2-8 ° C. Stability: In An Unexpected Form P. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Cardiac Ii. Reagents For The Cobas Pro/Pure Analyzer .. Purpose: A Set Of Control Materials Precicontrol Cardiac Ii Is Used For Quality Control Of Relevant Immunestes On Immunochemical Analyzers Cobas E. Precicontrol Cardiac Ii Is A Lyophilized Control Serum Based On Blood Serum In 2 Concentration Ranges. Control Materials Are Used To Control The Accuracy And Precision Of The Elecsys Ck -Mb, Ck -Mb Stat, Digitoxin, Digoxin, Myoglobin, Myoglobin Stat, Probnp Ii Stat And Gdf -11. Reagents - Working Solutions: ▪ Pc Cardii1: 2 Bottles, Each For 2.0 Ml Of Control Serum ▪ Pc Cardii2: 2 Bottles, Each For 2.0 Ml Of Control Serum. To Prepare Controls, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of The Components In Dissolved Control Serum: At –20 ° C (± 5 ° C) 3 Months, At 2-8 ° C 3 Days, On Board The Analyzers At 20-25 ° C To 3 Hours. In The Case Of The Technical Specifications Of Replacing The Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Thyroab. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: A Set Of Control Materials Precicontrol Thyroab Is Used For Elecsys Anti -Tshr, Anti -Tpo And Anti -Tg Immunitrus On Immunochemical Analyzers Elecsys And Cobas E. Precicontrol Thyroab Is A Lyophilized Control Serum Based On A Blood Sewer Matrix In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of The Elecsys Anti -Tshr, Anti -Tpo And Anti -Tg Immunestes. Reagents - Working Solutions: ▪ Pc Thyro1: 2 Bottles, For The Preparation Of 2.0 Ml Of Control Serum Each ▪ Pc Thyro2: 2 Bottles, For The Preparation Of 2.0 Ml Of Control Serum Each. To Prepare The Control Material, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of All Components In The Dissolved Control Serum: At -20 ° C (± 5 ° C) 1 Month Or At 2-8 ° C 3 Days, On Board The Analyzers At 20-25 ° C Until 5 Hours. In The Case Of Non -Compliance Of The Product Specification, Replacing The Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Universal. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: A Set Of Control Materials Precicontrol Universal Is Used For Elecsys Immunit Test Control On Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Universal Is A Lyophilized Control Serum Based On Blood Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunestes. Reagents - Working Solutions: ▪ Pc U1: 2 Bottles, For 2 X 3.0 Ml Of Control Serum (Person) ▪ Pc U2: 2 Bottles, For 2 X 3.0 Ml Of Control Serum (Humans). To Prepare Control Materials, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of All Components In Dissolved Control Serum: At -20 ° C (± 5 ° C) 1 Month, At 2-8 ° C 3 Days, On Board The Analyzers At 20-25 ° C Until 5 Hours .. In Case Of No Technical Specifications For The Replacement Of The Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Troponin. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: Control Material Precicontrol Troponin Is Used To Control The Qualities Of The Elecsys Troponin T Hs, Elecsys Troponin T Hs Stat, Elecsys Troponin I And Elecsys Troponin I Stat On Immunochemical Analyzers Cobas Pro. Precicontrol Troponin Is A Lyophilized Human Blood Serum With Added Toponin T And I In 2 Ranges Of Concentrations. Control Materials Are Used To Monitor The Accuracy And Precision Of The Elecsys Immunestes Troponin T Hs, Elecsys Troponin T Hs Stat, Elecsys Troponin I And Elecsys Troponin I Stat. Reagents - Working Solutions: ▪ Pc Tn1: 2 Bottles, Each For 2.0 Ml Of Control Serum ▪ Pc Tn2: 2 Bottles, Each For 2.0 Ml Of Control Serum. Troponin T (Recombinant, Human) In 2 Concentration Ranges (About 30 Ng/L Or Pg/Ml And About 2500 Ng/L Or Pg/Ml) And Troponin I (Recombinant, Human) In 2 Ranges) Concentrations (About 0.75 Μg/L Or Ng/Ml And About 18 Μg/L Or Ng/Ml) In The Matrix Of Human Serum. To Prepare Controls, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. Stability Of Dissolved Control Serum: At –20 ° C (± 5 ° C) 3 Months, At 2-8 ° C 4 Days, On Board The Analyzers At 20-25 ° C To 5 Hours. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Vitamin D Total Ii. The Reagents For The Cobas Pro/Pure Analyzer .. Purpose: A Set Of Control Materials Precicontrol Vitamin D Total Iii Is Used To Control The Quality Of The Elecsys Vitamin D Total Iii Immunochemical Analyzers. Precicontrol Vitamin D Total Iii Is A Lyophilized Blood Test Based On Blood Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Vitamin D Total Iii Immunestet. Reagents - Working Solutions: ▪ Pc Vitdt1: 3 Bottles, Each For Preparing 1.0 Ml Of Control Serum. Human Blood Serum; Conservice. The Target Value Is About 20 Ng/Ml (50 Nmol/L) ▪ Pc Vitdt2: 3 Bottles, Each For The Preparation Of 1.0 Ml Of Control Serum. Human Blood Serum; Conservice. The Target Value Is About 40 Ng/Ml (100 Nmol/L). To Prepare Controls, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. Stability Of Dissolved Control Serum: At -20 ° C (± 5 ° C) 31 Days, At 2-8 ° C 72 Hours, On Board The Analyzers At 20-25 ° C To 5 Hours. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Precicontrol Varia Control. Reagents For The Analyzer Cobas Pro/Pure .. Purpose: A Set Of Control Materials Precicontrol Varia Is Used For Quality Control Of Appropriate Elecsys Immunestes On Elecsys And Cobas E Immunochemical Analyzers. Precicontrol Varia Is A Lyophilized Control Serum Based On Blood Serum In Two Concentration Ranges. Control Materials Are Used To Monitor The Accuracy And Precision Of Elecsys Immunestes. Reagents - Working Solutions: ▪ Pc V1: 2 Bottles, Each For 3.0 Ml Of Control Serum ▪ Pc V2: 2 Bottles, Each For 3.0 Ml Of Control Serum. To Prepare The Control Material, Add Distilled Water. Storage And Stability: Store At 2-8 ° C. Liophilized Control Serum Is Stable Until The Specified Expiration Date. The Stability Of The Components In Dissolved Control Serum: At -20 ° C (± 5 ° C) 31 Days Or At 2-8 ° C 72 Hours, On Board The Analyzers At 20-25 ° C Until 5 Hours. In The Case Of The Technical Specifications Of The Replacement Of The Goods Within 3 Days After The Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base., Control Precicontrol Hbsag Ii. Reagents For The Cobas Pro/Pure Analyzer .. Purpose: A Set Of Control Materials Precicontrol Hbsag Ii Is Used For Elecsys Hbsag Ii And Elecsys Hbsag Ii Auto Confirm Immunochemical Analyzers Elecsys Elecsys E. Precicontrol Hbsag Ii Is A Ready -To -Use Control Serum Based On Blood Serum In Negative And In A Positive Concentration Range. Control Materials Are Used To Monitor The Accuracy Of The Elecsys Hbsag Ii And Elecsys Hbsag Ii Auto Confirm. Reagents - Working Solutions: ▪ Pc Hbsagii1: 8 Bottles, 1.3 Ml Of Control Serum In Each. Human Blood Serum With A Negative Test Result On Hbsag; Conservice. The Target Range For The Index Of The Threshold Value: 0.0-0.80. ▪ Pc Hbsagii2: 8 Bottles, 1.3 Ml Of Control Serum In Each Hbsag (Person) Is About 0.2 Iu/Ml In Human Blood Serum; Conservice. The Target Range For The Index Of The Threshold Value: 2.6-5.0. Control Materials Are Delivered Ready For Use In Bottles Compatible With The System. Storage And Stability: Store At 2-8 ° C. Stability: In Unnecessed Form At 2-8 ° C Until The Expiration Date Is Expired, After Opening At 2-8 ° C 8 Weeks, On Board The Analyzers At 20-25 ° C To 5 Hours. In The Case Of Non-Compliance Of The Goods Of The Technical Specification, Replacing Goods Within 3 Days After Notification. Before Supplying The Reagent, Update The Analyzer Reagents Base.
|