Tender For Running Contract For Deposited Works Under Eudc, Bareilly - The Work Of Safe Carriage Of The Foll ... in India
Tender Notice
TenderID
94537509
Tender Brief
Tender For Running Contract For Deposited Works Under Eudc, Bareilly - The Work Of Safe Carriage Of The Following Material From Cb Ganj Store Center To Work Siteunder The Jurisdiction Of Lt/11 Kv Vertical Under Eudc, Bareilly . Approx. Distance Upto 50 Km
Tender For Running Contract For Deposited Works Under Eudc, Bareilly - The work of safe carriage of the following material from CB Ganj store center to work siteunder the jurisdiction of LT/11 KV Vertical under EUDC, Bareilly . Approx. distance upto 50 Km. Including safe loading and unloading. 2 PCC Pole 8.5 meter long. 3 PCC Pole 11 meter long. 4 STP 9 Mtr Long 5 STP 11 Mtr Long 6 Line material i.e., cross arm/ pin insulator/stay/earthing rod/Ms Channel/MS Angle/ Disc Fitting/Disc Insulators etc 7 11 KV XLPE Cable Size 3x70sqmm 8 11 KV XLPE Cable Size 3x120sqmm 9 11 KV XLPE Cable Size 3x185sqmm 10 11 KV XLPE Cable Size 3x300sqmm 11 33 KV XLPE Cable Size 3x120sqmm 12 33 KV XLPE Cable Size 3x185sqmm 13 33 KV XLPE Cable Size 3x300sqmm 14 LT XLPE (1X240 sqmm) 15 LT XLPE (1X400 sqmm) 16 LT XLPE (1X630 sqmm) 17 LT XLPE (1X1000 sqmm) 18 LT XLPE (3.5X70 sqmm) 19 LT XLPE (3.5X120 sqmm) 20 LT XLPE (3.5X150 sqmm) 21 LT XLPE (3.5X240 sqmm) 22 LT XLPE (3.5X300 sqmm) 23 LT XLPE (3.5X400 sqmm) 24 LT XLPE (3.5X630 sqmm) 25 LT XLPE (3.5X1000 sqmm) 26 ACSR Weasel Conductor 27 ACSR Rabbit Conductor 28 ACSR Raccon Conductor 29 ACSR Dog Conductor 30 3 Phase Arial Bunched Conductor 31 1 Phase Arial Bunched Conductor 32 Distribution Box 1 Phase 33 Distribution Box 3 Phase 34 11 KVCable Box Size 3x70sqmm 35 11 KV Cable Box Size 3x120sqmm 36 11 KV Cable Box Size 3x185sqmm 37 11 KV Cable Box Size 3x300sqmm 38 33 KV Cable Box Size 3x120sqmm 39 33 KV Cable Box Size 3x185sqmm 40 33 KV Cable Box Size 3x300sqmm 41 Straight Through 42 11/0.4 KV 3 Phase 25 KVA T/F 43 11/0.4 KV 3 Phase 63 KVA T/F 44 11/0.4 KV 3 Phase 100 KVA T/F 45 11/0.4 KV 3 Phase 250 KVA T/F 46 11/0.4 KV 3 Phase 400 KVA T/F 47 11 KV Pilfer proof Metering cubical and CT PT Unit 48 33 KV Pilfer proof Metering cubical and CT PT Unit 49 Erection of new PCC Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms 50 PCC Pole 8.5 Mtr Long Single Pole 51 PCC Pole 8.5 Mtr Long Double Pole 52 PCC Pole 11 Mtr Long Single Pole 53 PCC Pole 11 Mtr Long Double Pole 54 ST Pole 9 Mtr Long Single Pole. 55 ST Pole 9 Mtr Long Double Pole. 56 ST Pole 11 Mtr Long Single Pole. 57 ST Pole 11 Mtr Long Double Pole. 58 ST Pole 11 Mtr Long Tri Pole. 59 ST Pole 11 Mtr Long Four Pole. 60 Grouting with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms 61 PCC Pole 8.5 Mtr Long Single Pole 62 PCC Pole 8.5 Mtr Long Double Pole 63 PCC Pole 11 Mtr Long Single Pole 64 PCC Pole 11 Mtr Long Double Pole 65 ST Pole 9 Mtr Long Single Pole. 66 ST Pole 9 Mtr Long Double Pole. 67 ST Pole 11 Mtr Long Single Pole. 68 ST Pole 11 Mtr Long Double Pole. 69 ST Pole 11 Mtr Long Tri Pole. 70 ST Pole 11 Mtr Long Four Pole. 71 Dismantling of PCC/ST Pole due to line shifting/damaged complete in all respect 72 PCC Pole 8.5 Mtr Long Single Pole 73 PCC Pole 8.5 Mtr Long Double Pole 74 PCC Pole 11 Mtr Long Single Pole 75 PCC Pole 11 Mtr Long Double Pole 76 ST Pole 9 Mtr Long Single Pole. 77 ST Pole 9 Mtr Long Double Pole. 78 ST Pole 11 Mtr Long Single Pole. 79 ST Pole 11 Mtr Long Double Pole. 80 ST Pole 11 Mtr Long Tri Pole. 81 ST Pole 11 Mtr Long Four Pole. 82 The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms 83 Dismantling of Old and damaged conductor complete in all respect 84 Dismantling of Existing Distribution Transformer for increasing capacity/Shifting complete in all respect 85 11/0.4 KV 3 Phase 25 KVA T/F 86 11/0.4 KV 3 Phase 63 KVA T/F 87 11/0.4 KV 3 Phase 100 KVA T/F 88 11/0.4 KV 3 Phase 250 KVA T/F 89 11/0.4 KV 3 Phase 400 KVA T/F 90 Laying, Stringing & Sagging of Following Conductor complete in all respect 91 ACSR Weasel Conductor 92 ACSR Rabbit Conductor 93 ACSR Raccon Conductor 94 ACSR Dog Conductor 95 3 Phase Arial Bunched Conductor 96 1 Phase Arial Bunched Conductor 97 Erection andfixing of New LTCable 98 LT XLPE (1X240 sqmm) 99 LT XLPE (1X400 sqmm) 100 LT XLPE (1X630 sqmm) 101 LT XLPE (1X1000 sqmm) 102 LT XLPE (3.5X70 sqmm) 103 LT XLPE (3.5X120 sqmm) 104 LT XLPE (3.5X150 sqmm) 105 LT XLPE (3.5X240 sqmm) 106 LT XLPE (3.5X300 sqmm) 107 LT XLPE (3.5X400 sqmm) 108 LT XLPE (3.5X630 sqmm) 109 LT XLPE (3.5X1000 sqmm) 110 After Mounting of CT PT unit on double pole, laying of 50 Mtr 11 KV 3cx70 sq mm cable in single circuit on river sand formDouble Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits 111 After Mounting of CT PT unit on double pole, laying of 50 Mtr 33 KV 3cx120 sq mm cable in single circuit on river sand formDouble Pole to metering room complete in all respect. Alongwith filling of 04 nos cable jointing kits 112 Under ground laying of Following cable in Single circuit on river sand to Double pole situated at both sides of road complete in all respect. Minimum depth should be 0.75 Mtr and cable should be covered by bricks from three sides. Along with filling of 04 nos cable jointing kits 113 11 KV XLPE Cable Size 3x70 sqmm 114 11 KV XLPE Cable Size 3x120 sqmm 115 11 KV XLPE Cable Size 3x185 sqmm 116 11 KV XLPE Cable Size 3x300 sqmm 117 33 KV XLPE Cable Size 3x120 sqmm 118 33 KV XLPE Cable Size 3x185 sqmm 119 33 KV XLPE Cable Size 3x300 sqmm 120 Under ground laying of Following cable in Single circuit by drill method to Double pole situated at both sides of NH/SH/Railway Crossing complete in all respect.Alongwith filling of 04 nos cable jointing kits 121 11 KV XLPE Cable Size 3x70 sqmm 122 11 KV XLPE Cable Size 3x120 sqmm 123 11 KV XLPE Cable Size 3x185 sqmm 124 11 KV XLPE Cable Size 3x300 sqmm 125 33 KV XLPE Cable Size 3x120 sqmm 126 33 KV XLPE Cable Size 3x185 sqmm 127 33 KV XLPE Cable Size 3x300 sqmm 128 Hoisting of Following size 11 KV & 33 KV XLPE Cableon double pole with GI pipe of size 6 " dia 4 Mtr long including the jumpering complete with clamps , nut and bolts 129 11 KV XLPE Cable Size 3x70 sqmm 130 11 KV XLPE Cable Size 3x120 sqmm 131 11 KV XLPE Cable Size 3x185 sqmm 132 11 KV XLPE Cable Size 3x300 sqmm 133 33 KV XLPE Cable Size 3x120 sqmm 134 33 KV XLPE Cable Size 3x185 sqmm 135 33 KV XLPE Cable Size 3x300 sqmm 136 Supply & Laying of G.I. Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (GI pipe would be Provided by contractor at his own cost) 137 Supply & Laying of HDPE Pipe at various places i.e road crossing & Hoisting etc. complete in all respect (HDPE pipe would be Provided by contractor at his own cost). 138 Chemical earthing of T/F& Fencingincluding all materials (chemical, gi pipe, gi strip, nut bolt, etc) 139 Earthing of distribution T/Ffor body & neutral upto water level with GI Pipe of 1.5" Dia. Including GI strip size 35x6 mm. (all material will be supplied by Contractor). 140 Construction of T/F plinth 1.5x1.5x2 m3 for mounting 250/400 KVA T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4" thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect All manpower, material and T&P provided by the contractor to complete the work. 141 Cage fencing of 250/400 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wire mesh) made of 10 No gauge in suitable size angle iron frame of size 7.5"(L)x5"(W)x8"(H) by strengthening of wire mesh 20x3 mm M.S. flat horizontally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All manpower, material and T&P provided by the contractor to complete the fabrication, transportation and installation. 142 The work of digging of pits, erection of Stay Clamp, Insulator etc. 143 Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. 144 Installation of 11 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 145 Installation of 33 KV Pilfer Proof Metering Cubicle in metering room complete in all respect 146 Mounting of Following Capacity Transformers as per norms complete in all respect 147 25 KVA T/F 148 63 KVA T/F 149 100 KVA T/F 150 250 KVA T/F 151 400 KVA T/F 152 Fixing of Distribution Box complete in all respect 153 Guarding at road crossing complete in all respect 154 Errection & Fixing of Cable box 155 11 KVCable Box Size 3x70sqmm 156 11 KV Cable Box Size 3x120sqmm 157 11 KV Cable Box Size 3x185sqmm 158 11 KV Cable Box Size 3x300sqmm 159 33 KV Cable Box Size 3x120sqmm 160 33 KV Cable Box Size 3x185sqmm 161 33 KV Cable Box Size 3x300sqmm 162 Straight Through 11 KVCable Box Size 3x70sqmm,3X120sqmm,3x185sqmm) 163 Straight Through 33 KVCable Box Size 3x70sqmm,3X120sqmm,3x185sqmm) 164 Supply & Fixing of Following Items to complete the work (If Not available in stores) 165 LT Clamps as per RESSPO Norms for PCC/ST pole 166 Nut & Bolt off size 167 F Clampas per RESSPO Norms 168 Shackle Insulatoras per RESSPO Norms 169 X-Arm Holding Clampas per RESSPO Norms 170 Stay Clampsas per RESSPO Norms 171 11 KV Composite Polymer Disc insulatoras per RESSPO Norms 172 Top Channel of size 100x50x2240 mmas per RESSPO Norms 173 T off Channelas per RESSPO Norms 174 11 KV Polymer Pin Insulator as per RESSPO norms 175 Safe back carriage of Distribution Transformer from work siteto C.B. Ganj store Bareilly approx. distance upto 50 Km including safe loading & unloading. 176 11/0.4 KV 3 Phase 25 KVA T/F 177 11/0.4 KV 3 Phase 63 KVA T/F 178 11/0.4 KV 3 Phase 100 KVA T/F 179 11/0.4 KV 3 Phase 250 KVA T/F 180 11/0.4 KV 3 Phase 400 KVA T/F
Contact Information
Contact Person
SE EUDC
Address
35-B RAMPUR GARDEN BAREILLY
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 94537509
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.