Tender For Annual Supply And Installation Of Electric Material To Umarga Municipal Council As Per Pwd Electric Csr 2023-24 For Fy 2025-26- WIRING (WG)-1.1 Concealing of Conduits (WG-MA/CC) 1-1-1 Supplying & erecting rigid steel conduit 16 SWG 20 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WGMA/ CC. 1-1-2 Supplying & laying rigid steel conduit 16 SWG 20mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WGMA/ CC. 1-1-3 Supplying & erecting rigid steel conduit 16 SWG 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WGMA/ CC. 1-1-4 Supplying & laying rigid steel conduit 16 SWG 25mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WGMA/ CC. 1-1-5 Supplying & erecting rigid steel conduit 16 SWG 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WGMA/ CC. 1-1-6 Supplying & laying rigid steel conduit 16 SWG 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WGMA/ CC. 1-1-7 Supplying & erecting HMS PVC conduit 20mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 1-1-8 Supplying & laying HMS PVC conduit 20mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 1-1-9 Supplying & erecting HMS PVC conduit 25mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 1-1-10 Supplying & laying HMS PVC conduit 25mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 1-1-11 Supplying & erecting HMS PVC conduit 32mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. 1-1-12 Supplying & laying HMS PVC conduit 32mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification no. WG-MA/CC. 1-1-13 Concealing of provided G.I. pipe/H.G. screwed conduit/PVC pipe in wall/floor/false ceiling complete as per specification no. WG-PW/CW Note:- Add Rs 3/- per metre for erecting conduit on stone wall. 1.2 PVC Flexible/Rigid Conduits/Casing-n-Capping/Under Floor Trunking/Raceways and Box System (WG-MA/CON) 1 Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit 2 Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit 2-3 Supplying and erecting HMS PVC conduit 20mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. 2-4 Supplying and erecting HMS PVC conduit 25mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. 2-5 Supplying and erecting HMS PVC conduit 32mm dia. with PVC accessories on wall/ceiling as per specification no. WG-MA/CON. 2-6 Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20mm with accessories on wall/ceiling as per specification no. WG-MA/CON. 2-7 Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification no. WG-MA/CON. 2-8 Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32mm with accessories on wall/ceiling as per specification no. WG-MA/CON. 2-9 Supplying and erecting PVC trunking (PVC casing-n-capping) of size 40mm with accessories on wall/ceiling as per specification no. WG-MA/CON. 10 Supplying and erecting PVC box trunking of size 50x16/20mm. with accessories on wall/ceiling as per specification no. WG-MA/BOX. 11 Supplying and erecting PVC box trunking of size 50x50mm with accessories on wall/ceiling as per specification no. WG-MA/BOX. 12 Supplying and erecting PVC box trunking of size 75x50mm with accessories on wall/ceiling as per specification no. WG-MA/BOX. 13 Supplying and erecting PVC box trunking of size 75x75mm with accessories on wall/ceiling as per specification no. WG-MA/BOX. 14 Supplying and erecting PVC box trunking of size 100x50mm with accessories on wall/ceiling as per specification no. WG-MA/BOX . 15 Supplying and erecting PVC slotted box trunking of size 25x25mm with accessories on wall/ceiling as per specification no. WG-MA/SLBOX. 16 Supplying and erecting PVC slotted box trunking of size 45x30mm with accessories on wall/ceiling as per specification no. WG-MA/SLBOX. 17 Supplying and erecting PVC slotted box trunking of size 60x45mm with accessories on wall/ceiling as per specification no. WG-MA/SLBOX. 18 Supplying and erecting PVC slotted box trunking of size 75x75mm with accessories on wall/ceiling as per specification no. WG-MA/SLBOX. 19 Supplying and erecting PVC slotted box trunking of size 100x100mm with accessories on wall/ceiling as per specification no. WG-MA/SLBOX. 20 Supplying & erecting GI flexible conduit 25mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete 1-2-21 Supplying & erecting GI flexible conduit 40mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete 1-2-22 Supplying & erecting GI flexible conduit 50mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete Note: Add Rs 3/- per metre for erecting conduit on stone wall. 1.3 Bunch of Wires (WG-MA/BW) 1-3-1 Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-2 Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW 1-3-3 Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW 1-3-4 Supplying & erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-5 Supplying & erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-6 Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-7 Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-8 Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-9 Supplying & erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-10 Supplying & erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-11 Supplying & erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-12 Supplying & erecting mains with 4x35 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW 1-3-13 Supplying and erecting PVC insulated PVC round sheathed FR 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 1-3-14 Supplying and erecting PVC insulated PVC round sheathed FR 1.5 sq.mm (30 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 1-3-15 Supplying and erecting PVC insulated PVC round sheathed FR 2.5 sq.mm (50 no. x 0.25mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 1-3-16 Supplying and erecting PVC insulated PVC round sheathed FR 4 sq.mm (56 no. x 0.30mm dia.) 3 core flexible multi stranded copper industrial cable for voltage grade up to 1.1 kV 1.4 Mains on GI Bare Wire (WG-MA/GB) 1-4-1 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1.1kV grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-2 Supplying and erecting mains with WP 2 x 4 sq. mm. 1.1 kV grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-3 Supplying and erecting mains with WP 2 x 6 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-4 Supplying and erecting mains with WP 3 x 4 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-5 Supplying and erecting mains with WP 3 x 6 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-6 Supplying and erecting mains with WP 4 x 4 sq. mm. 1.1kV. grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1-4-7 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1.1 kV grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire no. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 1.5 Wiring Accessories 1-5-1 Supplying and erecting one/two way piano type switch 6A/bell push erected on filled polypropylene board or double polished wooden board/ folded or screwed board with top of either wooden/ 3mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. 1-5-2 Supplying and erecting shockproof piano type switch 250V, 16A, erected on filled polypropylene board or polished double wooden/ folded or screwed board with top of either wooden/ 3mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. 1-5-3 Supplying and erecting shockproof 3 pin plug socket 6A with porcelain base/flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/ 3mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. 1-5-4 Supplying and erecting shockproof 3 pin plug socket 16A with porcelain base/ flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. 1-5-5 Supplying and erecting ceiling rose/ batten holder/ slanting holder/ hanging cord switch/ hanging bell push/ pendant holder bakelite base 6A erected on filled polypropylene board or polished double wooden block/ PVC junction box. 1-5-6 Supplying and erecting adaptor for lamp holder 230V A.C. supply. 1-5-7 Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6A erected on M.S Box made of 16 SWG sheet duly painted and covered with bakelite hylam sheet of 3mm thickness connected with earth terminals and leads duly concealed 1-5-8 Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6 A combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads 1-5-9 Supplying and erecting flush, shock proof plug socket 6 pin 6A and 16A with switch 16A combined unit erected in recess in 16 gauge M.S sheet box duly painted and connected with earth terminal and leads 1-5-10 Supplying and erecting flush type, shockproof plug socket 6 pin 6A and 16A with switch 16A combined unit erected on filled polypropylene board or double wooden block / 3mm thick hylam sheet / 4mm thick plywood pasted with 1.5mm thick sunmica with S M screws and duly connected. 1-5-11 Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board. 1-5-12 Supplying and erecting shockproof bell push on filled polypropylene board or sunmica covered wooden block with 2 core 0.5 sq.mm (TRS type) PVC insulated copper wire of 5m length connected to the point. 1-5-13 Supplying and erecting recess type 3 pin plug socket 6A with piano switch 6A combined unit erected on M.S box made up of 16 gauge sheet and covered with sunmica and with connecting leads 1-5-14 Supplying 6A 3 pin plug top bakelite type of 230V A.C. supply. 1-5-15 Supplying 16A 3 pin plug top bakelite type of 230V A.C. supply. Note:- Accessories erected on provided board, Rs 8/- per accessory shall be deducted for board. 1.6 Modular switches and Accessories 1-6-1 Supplying and erecting modular type switch 6A/10A on provided plate and box with wiring connections complete. 1-6-2 Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. 1-6-3 Supplying and erecting modular type bell-push 6A/10A on provided plate and box with wiring connections complete. 1-6-4 Supplying and erecting modular type bell-push with indicator 2 modules 6A/10A on provided plate and box with wiring connections complete. 1-6-5 Supplying and erecting modular type two way switch 6A/10A (2 module) on provided plate and box with wiring connections complete. 1-6-6 Supplying and erecting modular type switch 16/20 A with indicator on provided plate and box with wiring connections complete. 1-6-7 Supplying and erecting modular type switch one way 16/20 A on provided plate and box with wiring connections complete with neon indicator. 1-6-8 Supplying and erecting modular type D.P. switch 32A with indicator on provided plate and box with wiring connections complete. 1-6-9 Supplying and erecting modular type 32A, DP key tag switch with key tag on provided plate and box with wiring connections complete. 1-6-10 Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. 1-6-11 Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. 1-6-12 Supplying and erecting modular type indicator lamp on provided plate and box with wiring connections complete. 1-6-13 Supplying and erecting modular type 6/16A fuse unit on provided plate and box with wiring connections complete. 1-6-14 Supplying and erecting modular type T.V. socket single outlet on provided plate and box with wiring connections complete. 1-6-15 Supplying and erecting modular type telephone socket one gang with safety shutter on provided plate and box with wiring connections complete. 1-6-16 Supplying and erecting modular type telephone socket two gang with safety shutter on provided plate and box with wiring connections complete. 1-6-17 Supplying and erecting modular type computer Jack RJ 45 with safety shutter, on provided plate and box with wiring connections complete. 1-6-18 Supplying and erecting modular type bell indicator on provided plate and box with wiring connections complete. 1-6-19 Supplying and erecting modular type buzzer 220/250V on provided plate and box with wiring connections complete. 1-6-20 Supplying and erecting modular type (one module) electronic dimmer 400/450W on provided plate and box with wiring connections complete. 1-6-21 Supplying and erecting modular type (two module) electronic dimmer 600/650W on provided plate and box with wiring connections complete. 1-6-22 Supplying and erecting modular type (two module) electronic dimmer 1000W on provided plate and box with wiring connections complete. 1-6-23 Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete. 1-6-24 Supplying and erecting modular type blanking plate one module, on provided plate & box. 1-6-25 Supplying and erecting modular type blanking plate two module, on provided plate & box. 1-6-26 Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete. 1-6-27 Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module complete. 1-6-28 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module complete. 1-6-29 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete. 1-6-30 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module complete. 1-6-31 Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. 1-6-32 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module complete. 1-6-33 Supplying and erecting PVC Surface modular switch box with double mounting plate for 16/18 module complete. 1-6-34 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-35 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-36 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-37 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-38 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-39 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-40 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-41 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16/18 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-42 Supplying and erecting white footlight with 4 modules concealed modular box and LED lights with cover complete on wall /flush to wall with necessary chiselling in wall and finishing with cement and mortar / POP as per required and duly connected. 1-6-43 Supplying and erecting 16/20/25A starter (modular range) 2 module for AC unit on provided box complete & duly concealed with necessary material and connected. 1-6-44 Supplying and erecting 6 to 32A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. 1-6-45 Supplying and erecting 16 to 32A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. 1-6-46 Supplying and erecting PVC Surface modular double mounting plate 1 module complete. 1-6-47 Supplying and erecting PVC Surface modular double mounting plate 2 module complete. 1-6-48 Supplying and erecting PVC Surface modular double mounting plate 3 module complete. 1-6-49 Supplying and erecting PVC Surface modular double mounting plate 4 module complete. 1-6-50 Supplying and erecting PVC Surface modular double mounting plate 6 module complete. 1-6-51 Supplying and erecting PVC Surface modular double mounting plate 8 module complete. 1-6-52 Supplying and erecting PVC Surface modular double mounting plate 12 module complete. 1-6-53 Supplying and erecting PVC Surface modular double mounting plate 16/18 module complete. 1-6-54 Supplying and erecting modular safety power strip with one modular switch 16A and three sockets each 6A combination with overload and surge protection unit on double mounting plate complete. 1-6-55 Supplying and erecting modular switch with LED indicator available to connect in a switch board to glow LED when connected load is off, on provided double mounting plate complete. 1-6-56 Supplying and erecting modular type USB Charger socket of 1 module with nominal output voltage of 5V DC ±5% and nominal output current of 5V, 2-3A, on provided plate and box with wiring connections complete. 1-6-57 Supplying and erecting modular pop up Box 8 module with provided AV/ HDMI , RJ 45,6 A electrical sockets and switch on provided table . 1-6-58 Supplying power strip with one switch 6A and 4 sockets each 6A, 230 V, minimum cord length 1.5 meter, combination with surge and spike protection unit complete. 1.7 Point Wiring (WG-PW) 1-7-1 Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire,flush type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-2 Point wiring for independent plug in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire,flush type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-3 Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW 1-7-4 Point wiring for independent plug in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire,flush type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-5 Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW 1-7-6 Point wiring for ceiling fan concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW 1-7-7 Point wiring for independent plug, concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WGPW/ SW 1-7-8 Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type light/bell point wiring and terminating on modular accessories in box for point wiring for light/fan/bell as per specification no. WG-PW/CW 1-7-9 Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box for point wiring r specification no. WG-PW/CW 1-7-10 Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes and terminating on modular accessories in box for point wiring for independent plug as per specification No WG-PW/SW 1-7-11 Point wiring for light/bell/exhaust fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-12 Point wiring for ceiling fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-13 Point wiring for independent plug in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E ) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-14 Point wiring for light/bell hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW 1-7-15 Point wiring for ceiling fan hybrid type (surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm HMS PVC conduit / casing n caping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-HW 1-7-16 Point wiring in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch,earthing and required accessories as per specification no. WG-PW/SW 1-7-17 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm FRLSH grade copper wire, flush type switch,earthing and required accessories as per specification no. WG-PW/SW 1-7-18 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-19 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-20 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW 1-7-21 Secondary point wiring for additional light/bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires with required accessories as per specification no. WG-PW/CW 1-7-22 Secondary point wiring for additional light/bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification no. WG-PW/SW 1-7-23 (New) Secondary point wiring for additional light/bell point in min 20mm PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification no. WG-PW/SW 1-7-24 Wiring for plug on board with flush Switch socket, copper wiring and earthing as per specification no. WG-PW/SW 1-7-25 Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WGPW/ CW 1-7-26 Concealing of provided M.S./ PVC switch box in wall with finishing as per specification no. WG-PW/CW 1-7-27 Refilling the holes for dismantled point wiring with cement mortar & finishing. 1.8 Dismantling (WG-DM) 1-8-1 Dismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc. complete as per specification no. WG-DM/PW 1-8-2 Dismantling the existing aluminium/copper mains, sub-mains wiring upto 10 sq.mm. along with accessories etc. complete as per specification no. DM/PW 2.1 Indoor LED Fittings (FG-IDF/LED) 2-1-1 Supplying and erecting decorative pre-wired box type fitting / batten suitable for 4 feet, T8 LED tube light (excluding tube light). 2-1-2 Supplying and erecting LED square / circular Max. 7W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-3 Supplying and erecting LED square / circular Max. 11 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-4 Supplying and erecting LED square / circular Max. 14 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-5 Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-6 Supplying and erecting LED square / circular Max. 25 W down lighter / Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-7 Supplying and erecting LED Panel Light (600mm X 600mm) Max. 30 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-8 Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-9 Supplying and erecting rectangular shaped LED Panel Light (1200mm X 300mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 2 years warranty as per specification No. FG-IDF/LED. 2-1-10 Supplying and erecting LED Strip light Max. 45 W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1 year warranty as per specification No. FG-IDF/LED. 2-1-11 Supplying and erecting LED Strip light Max. 95 W IP20 class having minimum lumens output of 1600 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1 year warranty as per specification No. FG-IDF/LED. 2-1-12 Supplying LED concealed type foot / step light with aluminium body for indoor / outdoor application suitable for 4W - 6W LED including driver and erecting by making necessary arrangement / recess in wall to make it flush with surface with minimum 1 year warranty as per specification No. FG-IDF/LED. 2-1-13 Making suitable size recess in any type of false ceiling for erection of flush type down lighter and finishing the background to match the original surface upto 20W as per specification No. FG-IDF/LED. 2-1-14 Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm / 1200x300mm and finishing the background to match the original ceiling surface as per specification No. FGIDF/ LED. 2-1-15 Supplying and erecting Bulk Head LED fitting Max. 10W with high transitivity diffuser with system lumens output of Min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50, IP66, IK09 rated including driver IP66, IK09 rated on provided PVC Block / wooden board with minimum 2 years warranty per specification No. FG-IDF/LED. 2-1-16 Supplying and erecting anodized aluminium mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-17 Supplying and erecting CRCA powder coated mirror light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, IP 20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-18 Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-19 Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-20 Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 50W with high transitivity diffuser with system lumens output of Min. 6000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, rated including driver with end caps on provided PVC Block / wooded board with minimum years warranty as per specification No. FG-IDF/LED. 2-1-21 Supplying & erecting inverter LED batten 10W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mA Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 Hrs with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20 % having useful life of minimum 25000 Hrs with over heating protection with minimum 2 years warranty as per specification No. FG-IDF/LED. 2-1-22 Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mA Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 Hrs with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20 % having useful life of minimum 25000 Hrs with over heat protection with minimum 2 years as per specification No. FG-IDF/LED. 2-1-23 Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 X 20W UV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S. / steel body suitable to work on 230V, AC supply having top mounting arrangement with SS chain complete and 3 core flexible wire upto 1 mtr with minimum 1 year warranty as per specification No. FG-IDF/LED. 2-1-24 Erection of departmentally supplied 4ft/2ft LED fitting on PVC block connected with necessary leads complete as per specification No. FG-IDF/LED. 2-1-25 Erection of departmentally supplied surface / recess type decorative fitting with LED on PVC block connected with necessary leads as per specification No. FG-IDF/LED. Note:- 1) Driver and luminaire shall be of same make. 2) All required test reports as per IS of all luminaires shall be from accredited NABL laboratory. 3) Manufacturer Logo shall be embossed on all pressure die cast Luminaires and logo shall not be screen-print / sticker type. 4) All luminaires shall conform to respective IS. 2.2 Accessories for Indoor Fittings (FG-AS) 2-2-1 Supplying and erecting bakelite call bell with 6 cm / buzzer with double coil suitable for 230V complete erected on PVC block. 2-2-2 Supplying and erecting gong with double coil suitable for 230V A.C. supply complete erected on polished wooden block. 2-2-3 Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block / sunmica block of suitable size. 2-2-4 Supplying and erecting luminous / modular type call bell indicator with plastic body, heavy duty coil and indicator lamp working on 230V A.C. supply with resetting arrangement complete erected on double wooden / sunmica board. 2-2-5 Supplying and erecting electronic type cordless call bell erected on T.W. board having portable bell push working on 9V D.C. battery and (effective range upto 45 meter) bell on 250 V A.C. supply. 2-2-6 Supplying and erecting electronic type driver for indoor LED 5W - 9W fixtures suitable to operate on 230V A.C. 50 Hz having p.f.>0.95 and THD<10% as per specification No. FG-AS. 2-2-7 Supplying and erecting electronic type driver for indoor LED 10W - 18W fixtures suitable to operate on 230V A.C. 50 Hz having p.f.>0.95 and THD<10% as per specification No. FG-AS. 2-2-8 Supplying and erecting electronic type driver for indoor LED 19W - 24W fixtures suitable to operate on 230V A.C. 50 Hz having p.f.>0.95 and THD<10% as per specification No. FG-AS. 2-2-9 Supplying and erecting electronic type driver for indoor LED 25W - 40W fixtures suitable to operate on 230V A.C. 50 Hz having p.f.>0.95 and THD<10% as per specification No. FG-AS. 2.3 Outdoor Fittings (FG-ODF) 2-3-1 Supplying and erecting integrated LED street light fitting 18 - 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. 2-3-2 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. 2-3-3 Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. 2-3-4 Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. 2-3-5 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. 2-3-6 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. 2-3-7 Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. 2-3-8 Supplying and erecting integrated LED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/ SL. 2-3-9 Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minium 2 Years warranty as per specification No. FG-ODF/SL. 2-3-10 Supplying and erecting integrated LED street light fitting 130-140W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 15600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. 2-3-11 Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140- 270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. 2-3-12 Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-13 Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-14 Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-15 Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-16 Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-17 Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-18 Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FGODF/ FL. 2-3-19 Supplying and erecting integrated LED Bollard Cylindrical / Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with minimum 2 Year warranty as per specification No FG-ODF/BL. 2-3-20 Supplying and erecting integrated LED Bollard Cylindrical / Cubical shaped 800mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser, having system lumens output of Min. 800 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 25,000 Hrs. at L50B50, including driver complete with minimum 2 Year warranty as per specification No FG-ODF/BL. 2-3-21 Supplying and erecting integrated LED Post Top 45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser, having system lumens output of Min.4500 Lumens, min. efficacy of 105 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs at L50B50 , including driver complete with minimum 2 Year warranty as per specification No FG-ODF/PT. 2-3-22 Supplying and erecting integrated LED round burial light 6W IP65 & IK10 class having pressure die-cast housing, having system lumens output of Min. 500 Lumens, min. efficacy of 85 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 100-240V, inbuilt surge protection of 2 kV, Life class of 50,000 Hrs at L50B50 , slat spray tested for 500 Hrs. including making of recess of appropriate size for flushing into surface with minimum 2 Year warranty as per specification No FG-ODF/PT. 2-3-23 Supplying and erecting Concealed type foot/step light Max. 5W having IP67, IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs at L70B50, including driver by making necessary arrangement / recess in wall to make it flush with surface with minimum 2 Year warranty. 2-3-24 Erecting the departmentally supplied WP LED street light / flood light fitting upto 80W. 2-3-25 Erecting the departmentally supplied LED street light / flood light fitting above 80 to 150W. 2-3-26 Erecting departmentally supplied LED street light/ flood light Fitting above 150 to 400W . 2.4 Decorative Outdoor Fittings (FG-ODF) 2-4-1 Supplying and erecting Gate / garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT. 2-4-2 Supplying and erecting Gate / garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT. 2-4-3 Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG-ODF/PTL. 2-4-4 Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FGODF/ PTL. 2-4-5 Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL. 2.5 Highbay LED Fittings (FG-ODF/LED) 2-5-1 Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/LED. 2-5-2 Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50 , including driver complete with 2 Year warranty as per specification No. FG-ODF/LED. 2-5-3 Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs at L50B50 , including driver complete with 2 Year warranty as per specification No. FG-ODF/LED. 2.6 Accessories for Outdoor Fittings (FG-BKT) 2-6-1 Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. 2-6-2 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. 2-6-3 Supplying and erecting street light Wall bracket made from 25 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FGBKT/ WB. 2-6-4 Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FGBKT/ WB. 2-6-5 Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/SLB 2-6-6 Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/SLB 2-6-7 Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m long “B” grade G.I. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/SLB 2-6-8 Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m long “B” grade G.I. pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/SLB 2-6-9 Supplying and erecting Street light bracket for erection of side entry fitting on pole with 25 mm. dia. ‘B’ grade G.I. pipe of required length complete as per specification no. FG-BKT/SLB 2-6-10 Supplying and erecting Street light bracket for erection of side entry fitting on pole with 40 mm. dia. ‘B’ grade G.I. pipe of required length complete as per specification no. FG-BKT/SLB 2-6-11 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2-6-12 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 26W-45W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2-6-13 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 46W-75W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2-6-14 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 76W-100W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2-6-15 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 101W-150W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2-6-16 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 151W-200W suitable to operate on 230V A.C. 50 Hz. having p.f>0.95 and THD<10% as per specification no. FG-ODF/AS. 2.7 Lamps and Tubes for Indoor & Outdoor (FG-LP) 2-7-1 Supplying & erecting 0.5W, 230V integral type LED Lamp suitable for B-22/E- 27 base as per specification no. FG-LP. 2-7-2 Supplying and erecting LED Pigmy /candle lamp miniature type coloured/ white up to 4 watt suitable for B-22/E-27 base as per specification no. FG-LP. 2-7-3 Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22/E- 27 base as per specification no. FG-LP. 2-7-4 Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B- 22/E-27 base as per specification no. FG-LP. 2-7-5 Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B- 22/E-27 base as per specification no. FG-LP. 2-7-6 Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22/E- 27 base as per specification no. FG-LP. 2-7-7 Supplying & erecting 18W, 230V integral type LED Lamp suitable for B-22/E- 27 base as per specification no. FG-LP. 2-7-8 Supplying & erecting ready to use Retrofit T8 LED, 18 / 20 watt tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary as per specification No. FG-LP/RET. 2.8 Aviation Light Fitting (FG-AV) 2-8-1 Supplying & erecting aviation obstruction light minimum up to 48 watt consisting of yellow painted die-cast aluminium alloy housing with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete as per specification No. FG-AV. 2.9 Fans (FG-FN) 2-9-1 Supplying and erecting regular/ standard model ceiling fan of 600mm. sweep complete erected in position as per specification no. FG-FN/CF. 2-9-2 Supplying and erecting regular/ standard model ceiling fan of 900 /1050 mm. sweep complete erected in position as per specification no. FG-FN/CF. 2-9-3 Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF. 2-9-4 Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard with regulator and moisture proof treatment to winding and with ‘E’ class insulation. 2-9-5 Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. 2-9-6 Providing and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. 2-9-7 Supplying Pedestal fan 400 mm. 230 Volts 50 cycles oscillating type complete with guard and regulator 3 mtrs. of flexible wire and hand shield type 3 pin plug top. 2-9-8 Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation. 2-9-9 Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. 2-9-10 Supplying Table fan of A.C. 230 V. 50 cycles 400 mm. oscillating type complete with 2 mtrs. of 3 core flexible wire and Hand shield type 3 pin plug top. 2-9-11 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 250 mm. /300 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. 2-9-12 Supplying and erecting cabin fan of A.C. 230 V. 50 cycles 400 mm. sweep complete with necessary brackets for fixing cabin fans, wire etc. 2-9-13 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. 2-9-14 Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF 2-9-15 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as per specification no. FGFN/ EXF 2-9-16 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF 2-9-17 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF 2-9-18 Supplying and erecting exhaust fan heavy duty 440 V A.C. 50 cycles 900 RPM 375/380 mm complete erected in position as per specification no. FG-FN/EXF 2-9-19 Supplying and erecting Energy Saving Ceiling fan of 3 star rating as per BEE 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 2-9-20 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 600 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8, PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF. 2-9-21 (New) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 900 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8, PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF. 2-9-22 (New) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF 2-9-23 (New) Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1400 mm, Max. Energy Consumption of 28W having service ratio (CMM/W) of Min. 8, PF>0.9, THD<10% with IR remote control, Temperature Rise of Max. 40 deg.C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF. Note:- Item No. 2-9-20 to 2-9-23 Reduce rate by 10% for BLDC fan without IR remote control. 2.10 Accessories for Fans (FG-FAS) 2-10-1 Supplying and erecting condenser 2.5 micro farad for ceiling fan 2-10-2 Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 2-10-3 Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 2-10-4 Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. 2-10-5 Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab. 2-10-6 Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. 2-10-7 Erection of departmentally supplied ceiling fan with necessary materials complete. 2-10-8 Erection of departmentally supplied exhaust fan with necessary materials complete. 2-10-9 Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete erected on provided switch board. 2-10-10 Providing recess in brick wall suitable for erection of exhaust fan up to 450 mm sweep complete with grouting of nut, bolts, plaster in hand colour washing to match the colour of the wall for the wall thickness of 150 mm. 2-10-11 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. 2-10-12 Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 375 mm. 2-10-13 Providing recess in stone wall suitable for erection of exhaust fan up to 450mm sweep complete with grouting of nut, bolts, plastering and colour washing to 2-10-14 Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC. 2-10-15 Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FG-FAS/MSC. 2-10-16 Supplying & erecting 22 SWG G.I sheet metal cawl sector shaped with 25 x 25 x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FG-FAS/MSC. 2-10-17 Supplying & erecting 20 SWG G.I sheet metal cawl rectangular / round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 300 mm as per specification no FGFAS/ MSC. 2-10-18 Supplying & erecting 20 SWG G.I sheet metal cawl rectangular /round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 400 mm as per specification no FGFAS/ MSC. 2-10-19 Supplying & erecting 20 SWG G.I sheet metal cawl rectangular /round shaped with 25 x 25x 3 (mm) angle iron frame, metal mesh to avoid birds entry with necessary material, suitable for exhaust fan of 450 mm as per specification no FGFAS/ MSC. 2.11 Dismantling 2-11-1 Dismantling of existing fluorescent fittings of any type & size. 2-11-2 Dismantling the existing W.T. fluorescent fitting / S.V./ M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete. 2-11-3 Dismantling the existing W.T. fluorescent fitting/ S.V./ M.V. / M.H. lamp /LED fitting from pole with brackets complete. 2-11-4 Dismantling the existing ceiling fan /exhaust fan / cabin fan / bracket fan complete with accessories, G.I. down rod, frame etc. and making the site clear. Note:- 1) Above rates are inclusive of transportation to the sub-divisional store or as directed by sectional officer. 2) All fans & fittings shall be marked with sr. no. & date of erection. 3.1 Water Heaters (AP-WH) 3-1-1 Supplying and erecting storage type water heater 15 litres capacity having standing loss < 0.381 kWh/24hour/45°C ,high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water& corrosion protection, with minimum 3 safety protections (i.e. thermostat &thermal cutout,multi function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 3-1-2 Supplying and erecting storage type water heater 25 litres capacity having standing loss < 0.465kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank, heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 3-1-3 Supplying and erecting storage type water heater 35 litres capacity having standing loss < 0.531 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat & thermal function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 3-1-4 Supplying and erecting storage type water heater 50 litres capacity having standing loss < 0.614 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat &thermal function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 3-1-5 Supplying and erecting storage type water heater 100 litres capacity having standing loss < 0.796 kWh/24hour/45°C, high impact resistance engineering plastic body with anti corrosive high grade steel inner tank heating element having hard water & corrosion protection, with minimum 3 safety protections (i.e. thermostat &thermal function valve) complete with 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as per specification no. AP-WH/STWH 3-1-6 Supplying and erecting midget type 3.0 litres instant type water heater of rustproof & shockproof ABS plastic body, high grade SS inner tank & 3kW heating element with corrosion & hard water protection, with minimum 3 safety protections (i.e. thermostat & thermal function valve) complete with 6.5 bar pressure withstanding capacity 230/250V, 50Hz, A.C. supply with inlet and outlet, with 3 core PVC flexible copper wire leads duly tested and marking sr. no. and date of erection complete. 3-1-7 Supplying and erecting chromium plated heavy duty brass stop cock for inlet pipe of water heater (15 mm. dia). 3-1-8 Supplying & erecting 15 mm brass non return valve for inlet pipe of storage water heater. 3-1-9 Supplying & erecting dead weight pressure releasing valve for storage water heater with necessary materials complete. 3-1-10 Supplying & erecting vacuum relief valve for storage water heater with necessary materials complete. 3-1-11 Providing fibre reinforced pvc flexible pipe upto 1m length with brass locking nuts and washers and clips at both ends suitable for hot water and cold water both (1 set of 2 nos) complete. 3-1-12 Supplying and erecting ISI mark heating element 2 / 3 kW suitable for water heater/ midget of any make any capacity. 3-1-13 Supplying and erecting ISI mark thermostat suitable for water heater / midget of any make, any capacity. 3-1-14 Erecting departmentally supplied water heater of 15 / 25 ltr capacity with wall fasteners, inlet & outlet pipes, NRV, etc. and marking sr no. and date of erection. 3-1-15 Erecting departmentally supplied water heater of 35/ 50 / 100 ltr capacity with wall fasteners, inlet & outlet pipes, NRV, etc. and marking sr. no. and date of erection. 3-1-16 Dismantling unserviceable storage type water heater from site to workshop and back after duly repaired and re-erecting the repaired storage water heater in position with necessary material complete with To & Fro transportation. 3.2 Air Conditioners (AP-AC) 3-2-1 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1convertible mode for compressor, room air conditioning unit 0.7TR to 0.9TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. APAC/ WAC 3-2-2 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. APAC/ WAC 3-2-3 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC 3-2-4 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC 3-2-5 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.5 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-6 Supplying, installing, testing & commissioning window type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.00TR capacity having ISEER minimum 3.1 to maximum 3.29 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC 3-2-7 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 0.7TR to 0.9TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-8 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-9 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-10 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-11 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-12 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-13 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/SAC 3-2-14 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 2.1TR to 2.3TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-15 Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega spilt) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/SAC 3-2-16 Supplying, installing, testing & commissioning split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega spilt) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC 3-2-17 Supplying, installing, testing & commissioning cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room air conditioning unit 1.3TR to 1.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser, dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-18 Supplying, installing, testing & commissioning cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 1.8TR to 2.1TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condensor,dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-19 Supplying, installing, testing & commissioning cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 2.5TR to 2.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser, dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-20 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 2.8TR to 3.3TR capacity with refrigerant R32/R410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega spilt) mounting type complete with temperature display on indoor unit, dust filter, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-21 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 3.4TR to 3.9TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega spilt) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-22 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega spilt) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. AP-AC/ WAC 3-2-23 Supplying ,installing , testing and commissioning tower type room AC unit of 2.5TR to 2.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/410A & copper condenser coil with anticorrosive fins copper condenser , hydrophilic evaporator fins powder coated outer body ,with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe. 3-2-24 Supplying ,installing , testing and commissioning tower type room AC unit of 3.5TR to 3.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator fins powder coated outer body, with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe. 3-2-25 Supplying, installing, testing and commissioning tower type room AC unit of 4.0TR to 4.9TR capacity suitable to operate on 415V, 50 Hz, A.C. supply having 1 no AHU and 1 no cabinet type floor mounting type condensing unit with refrigerant R32/R410A & copper condenser coil with anticorrosive fins copper condenser, hydrophilic evaporator Fins Powder coated outer body, with scroll/rotary compressor connected with provided refrigerant pipes, electric cables and drain pipe. 3-2-26 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete as per specification no. AP/AC-CP 3-2-27 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete as per specification no. AP/AC-CP 3-2-28 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete as per specification no. AP/AC-CP 3-2-29 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 32mm complete as per specification no. AP/AC-CP 3-2-30 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 35mm complete as per specification no. AP/AC-CP 3-2-31 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 42mm complete as per specification no. AP/AC-CP 3-2-32 supplying floor mounted de-humidifier of ABS engineering plastic body 320 to 360W, 220-240V, 50 Hz, A.C. supply of 16 to 22 liter/day (300°C-80%- 90%RH) capacity having rotary compressor consisting with refrigerant R410A/R134A running temperature capacity 50°C-350°C, tank capacity 3-4.5litre, noise level below 40dBA with digital display, programmable timer, humidity display, humidity setting arrangement, air flow 150 to 200cu.m/hr and suitable for cover 70-100cu.m area. 3-2-33 Supplying floor mounted de-humidifier of ABS engineering plastic body 470 to 530W, 220-240V, 50 Hz , A.C. supply of 30 to 35 liter/day (300°C-80%- 90%RH) capacity having rotary compressor consisting with refrigerant R410A/R134A running temperature capacity 500C-3500C, tank capacity 3.7- 6.5litre, noise level 45-49dBA with digital display, programmable timer, humidity display, humidity setting arrangement, air flow 190 to 220 cu.m/hr and suitable for cover 101-115 cu.m area. 3-2-34 Supplying floor mounted de-humidifier of ABS engineering plastic body 740W, 220-240V, 50 Hz A.C. supply of 50 litre/day (300°C-80%RH) capacity having rotary compressor consisting with refrigerant R410A/R134A running temperature capacity 50°C-350°C, tank capacity 8 liter, noise level 47dBA with digital display, programmable timer, humidity display, humidity setting arrangement, air flow 310 cu.m/hr and suitable for cover 150cu.m area. 3-2-35 Supplying, installing, testing & commissioning portable type room air conditioner having ISEER minimum 3.33 suitable to operate on 250V, 50 Hz, A.C. supply minimum 1TR capacity complete with refrigerant R32/R410A at position with drain pipe arrangement with small bucket of size minimum 1litre with necessary wheel base for movement. 3-2-36 Providing modifications to the existing window for erection of window room air conditioner in position with good quality teak wood as per requirement and filling the gaps to maintain air tightness. 3-2-37 Providing and pasting superior quality sun control film on glass to achieve better cooling effect having 1.5/2mm thickness, ultra violet transmittance less than 2% and solar heat rejection 78%. Note:- (New) 1) For copper pipe nitrile rubber insulation refer to chapter 4. 2) For drain piping refer rates of PVC pipes from chapter no. 1. 3) Rates of Split type Air Conditioning Units (Item No. 3-2-7 to 3-2-14) are inclusive of suitable size Copper Pipe, Nitrile insulation and 3 Core flexible PVC wire upto 3 meters length. 3.3 Water Coolers & Refrigerators (AP-WC) 3-3-1 Supplying single door refrigerator domestic type of 170 to 195 litres storage capacity, minimum 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50 cycles complete with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection. 3-3-2 Supplying single door refrigerator domestic type of 200 to 230 litres storage capacity, minimum 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50 cycles complete with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection. 3-3-3 Supplying double door refrigerator domestic type of 300 to 360 litres storage capacity, minimum 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50 cycles complete with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection. 3-3-4 Supplying double door refrigerator domestic type of minimum litres storage capacity, minimum 415 litter 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50 cycles complete with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection. 3-3-5 Supplying Deep Freezer commercial type of make 200 litres storage capacity, with double door suitable for operation on 230/250 V 50 cycles complete with compressor automatic temperature control with minimum temperature range -18°C to -22°C ,Manual Defrost Type, with refrigerant R290/R404a marking sr. no. and date of erection. 3-3-6 Supplying Deep Freezer commercial type of make 400 litres storage capacity, with double door suitable for operation on 230/250 V 50 cycles complete with compressor automatic temperature control with minimum temperature range -18°C to -22°C ,Manual Defrost Type, with refrigerant R290/R404a marking sr. no. and date of erection. 3-3-7 Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 20 litres per hour and storage capacity 20 litres with partially stainless steel body As per specification No. APWCR/ WC 3-3-8 Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50 cycles nominal cooling capacity of 40 litres per hour and storage capacity 80 litres with partially stainless steel body As per specification No. APWCR/ WC 3-3-9 Supplying, erecting, testing and commissioning self contained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC 3-3-10 Supplying, erecting, testing and commissioning self contained water cooler 230/250 Volts 50 cycles nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification No. AP-WCR/WC 3.4 Air-Coolers (AP-ACR/DAC) 3-4-1 Supplying 230/250 Volts, 50Hz, evaporative air cooler (desert cooler) having normal cooling capacity of 50 cu.m per minute, with 12" exhaust, min 40 to 55 litres water capacity tank with galvanised steel sheet with Grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25 mm, Filter pads shall be made of wood wool or any other substitute placed in noncorrosive wire mesh and tightened at places with side panels, noise level should not be more than 65 dBA at 1 m distance, 3 core copper cable minimum 2 m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthing complete as per specification No. AP-ACR/DAC 3-4-2 Supplying evaporative air cooler (desert cooler) with galvanised steel sheet with Grade 350 minimum, leak or drip free, front grill shall be made of noncorrosive material, circular opening shall be more than fan sweep but not exceeding more than 25 mm, Filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65 dBA at 1 m distance, A three-corecable minimum 2 m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling operate on 230/250 Volts,50Hz,normal cooling capacity of 60 to 70 cu.m per minute, with 12" exhaust ,min 68 litres water capacity tank complete as per specification No. AP-ACR/DAC 3-4-3 Supplying evaporative air cooler (desert cooler) with galvanised steel sheet with Grade 350 minimum, leak or drip free, front grill shall be made of noncorrosive material, circular opening shall be more than fan sweep but not exceeding more than 25 mm, Filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65 dBA at 1 m distance, A three-corecable minimum 2 m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling operate on 230/250 Volts,50Hz,normal cooling capacity of 80 cu.m per minute, with 12" exhaust ,min 75 to 80 litres water capacity tank complete as per specification No. AP-ACR/DAC 3-4-4 Supplying evaporative air cooler (desert cooler) duct type with galvanised steel sheet with Grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25 mm, Filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65 dBA at 1 m distance, A three-corecable minimum 2 m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling operate on 230/250 Volts,50Hz,normal cooling capacity of 100 cu.m per minute, with 15" exhaust ,min 75 to 80 litres water capacity tank complete as per specification No. AP-ACR/DAC 3-4-5 Supplying evaporative air cooler (desert cooler) duct type with galvanised steel sheet with Grade 350 minimum, leak or drip free, front grill shall be made of non-corrosive material, circular opening shall be more than fan sweep but not exceeding more than 25 mm, Filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels, noise level should not be more than 65 dBA at 1 m distance, A three-corecable minimum 2 m length & metal casing of the electrical components, metal frame or chassis of cooler cabinet and all exposed metallic parts, shall be provided with proper earthling operate on 230/250 Volts, 50Hz, normal cooling capacity of 120 cu.m per minute, with 17" exhaust ,min 75 to 80 litres water capacity tank complete as per specification No. AP-ACR/DAC 3.5 Water Purifiers (AP-WPF) 3-5-1 Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230 V single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200) 3-5-2 Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity, choke made of copper wire, two indicator lamps, dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230 V single phase AC supply with UV fail & filter change indication system. Note:- Add Rs.2000/- for sample water testing charges including transportation, sample collecting and report within two days. 3.6 Inverter (AP-INV) 3-6-1 Supplying, installing, testing and commissioning of 700 VA digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries) 3-6-2 Supplying, installing, testing and commissioning of 800 VA to 900 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries) 3-6-3 Supplying, installing, testing and commissioning of 1400 VA to 1600 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries) 3-6-4 Supplying, installing, testing and commissioning of 2500 VA Digital pure sine wave inverter based on Insulated Gate Bipolar Transistor (IGBT) technology single phase 230V,50 Hz complete as per specification no. AP-INV (Without batteries) Note : Backup time in hours and battery capacities in ampere hour (Ah) shall be specifically mentioned and suitable item from 3.8 shall be incorporated as per requirement. 3.7 Online Uninterruptible Power Supply (UPS) (AP-UPS) 3-7-1 Supplying, erecting, testing & commissioning of 1 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf , single phase input & 1 phase output complete with all protections as per specification no. APUPS (Without batteries) 3-7-2 Supplying, erecting, testing & commissioning of 2 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. APUPS( Without batteries) 3-7-3 Supplying, erecting, testing & commissioning of 3 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf ,single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (Without batteries) 3-7-4 Supplying, erecting, testing & commissioning of 6 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,single phase input & 1 phase output complete with all protections as per specification no. APUPS (Without batteries) 3-7-5 Supplying, erecting, testing & commissioning of 10 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,single phase input & 1 phase output complete with all protections as per specification no. APUPS (Without batteries) 3-7-6 Supplying, erecting, testing & commissioning of 10 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input & 1 phase output complete with all protections as per specification no. APUPS( Without batteries) 3-7-7 Supplying, erecting, testing & commissioning of 10 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input & 3 phase output complete with all protections as per specification no. APUPS( Without batteries) 3-7-8 Supplying,erecting, testing & commisioning of 20 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input &3 phase output complete with all protections as per specification no. AP-UPS (Without batteries) Note : Backup time in hours and battery capacities in ampere hour (Ah) shall specifically mentioned and suitable item from 3.8 shall be incorporated per requirement. 3.8 Batteries for Inverter & UPS 3-8-1 Supplying and erecting 12 V/80Ah to 88 Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-2 Supplying and erecting 12 V/100Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-3 Supplying and erecting 12 V/130Ah to 135Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-4 Supplying and erecting 12 V/150Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-5 Supplying and erecting 12 V/180Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-6 Supplying and erecting 12 V/200Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete 3-8-7 Supplying and erecting 12 V/7Ah -7.5Ah SMF battery with battery terminal wire, duly charged complete with 12 months warranty complete 3-8-8 Supplying and erecting 12 V/17Ah -18Ah SMF battery with battery terminal wire, duly charged complete with 12 months warranty complete 3-8-9 Supplying and erecting 12 V/26Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete 3-8-10 Supplying and erecting 12 V/42Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete 3-8-11 Supplying and erecting 12 V/65Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete 3-8-12 Supplying and erecting 12 V/100Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete. Note : Item no. 3.8.7 to 3.8.12 shall be used for UPS and Lift ARD (Auto Rescue Device) system. 3.9 Voltage Stabilizers 3-9-1 Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V 1% rated for 0.5 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 6/16 A plug top complete with overload & short circuit protection 3-9-2 Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270V and output voltage 200 to 250V rated for, 1 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16A plug top 3-9-3 Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V 1% rated for 3 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 plug top complete with overload & short circuit protection 3-9-4 Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 4 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection 3-9-5 Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 5 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection Note : All the appliances shall be marked with sr no and date of erection with enamel paint/permanent marker after Installation. 3.10 Accessories for AC & Water cooler 3-10-1 Providing servicing of 1/1.5/2/3 TR capacity split/window air conditioning unit complete with all necessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit and submitting report to Engineer incharge. 3-10-2 Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and plastic material. 3-10-3 Providing annual comprehensive maintenance contract for 1.5 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 3-10-4 Providing annual comprehensive maintenance contract for 2 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 3-10-5 Providing annual comprehensive maintenance contract for 3TR to 4.5 TR split/tower/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material 3-10-6 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 3-10-7 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1.5 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 3-10-8 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 3-10-9 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2.5 TR to 4.5 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 3-10-10 Providing flushing out cooling coil and condensor coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure in an approved manner. 3-10-11 Providing brazing pipes and checking leakages in the split/ window unit duly with dry nitrogen pressure in an approved manner. 3-10-12 Providing replacement of unserviceable starting relay for AC unit. 3-10-13 Providing replacement of unserviceable starting capacitor for A/C unit. 3-10-14 Providing replacement of unserviceable running capacitor for A/C unit. 3-10-15 Providing replacement of unserviceable fan motor capacitor for A/C unit. 3-10-16 Providing replacement of unserviceable PCB for A/C unit upto 3 TR capacity. 3-10-17 Providing repair of of faulty PCB for air conditioning unit upto 3 TR capacity. 3-10-18 Supplying and installing of new fan motor for condensor for air conditioning unit 3-10-19 Supplying and installing of new fan motor for indoor unit of air conditioner up to 3 TR suitable to operate on 230V to 250V AC or 280V to 340V DC supply having 4 to 8 poles as per requirement. 3-10-20 Supplying and installing new fan blade outdoor unit for air conditioning unit. 3-10-21 Providing replacement of blower of indoor unit for air conditioning unit. 3-10-22 Providing replacement of remote of indoor unit for air conditioning unit. 3-10-23 Providing vaccumising the airconditioner system and charging with R-22 refrigerant for air conditioning unit. 3-10-24 Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit. 3-10-25 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1TR window/split air conditioning unit. 3-10-26 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1.5TR window/split air conditioning unit. 3-10-27 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 2TR window/split air conditioning unit. 3-10-28 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 3TR window/split air conditioning unit. 3-10-29 Providing replacement of existing unserviceable compressor of 40 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerant with guarantee for one year. 3-10-30 Providing replacement of existing unserviceable compressor of 60 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerant with guarantee for one year. 3-10-31 Providing replacement of existing unserviceable compressor of 150 litre cooling capacity water cooler by new one of same capacity alongwith suitable refrigerant with guarantee for one year. 3-10-32 Providing replacement of existing unserviceable condensor coil of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 3-10-33 Providing replacement of existing unserviceable SS water tap of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and alongwith guarantee one year with suitable refrigerant. 3-10-34 Providing replacement of existing unserviceable relay 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 3-10-35 Providing replacement of existing unserviceable thermostat of 40/80/ litre cooling capacity water cooler by new one of same capacity, testing the satisfaction of site engineer for cooling and alongwith guarantee for one year with suitable refrigerant. 3-10-36 Supplying and erecting candle filter with filter pot for water cooler. 3-10-37 Supplying and erecting connector pipe for candle filter of water cooler. 3-10-38 Providing replacement of base tray of water cooler of any capacity. 3.11 VRV/VRF Air conditioning 3-11-1 Supplying, erecting, testing and commissioning of 6HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-2 Supplying, erecting, testing and commissioning of 7HP to 8HP, VRF/VRV conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-3 Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-4 Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-5 Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-6 Supplying, erecting, testing and commissioning of 16HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-7 Supplying, erecting, testing and commissioning of 18HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-8 Supplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-9 Supplying, erecting, testing and commissioning of 22HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-10 Supplying, erecting, testing and commissioning of 24HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-11 Supplying, erecting, testing and commissioning of 26HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-12 Supplying, erecting, testing and commissioning of 28HP, VRF/VRV air conditioning system out door unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 3-11-13 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 3-11-14 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type room/indoor unit (IDU) of nominal cooling capacity 1.0TR (358 cfm) to 1.25TR (417 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area. Unit shall be of decorative slim dimension suitable indoor wall mounting. The indoor unit shall also have an electronic control console. The unit shall be suitable for wall mounting and provided with suitable mounting brackets with any additional refrigerant and oil charge as per requirement during installation complete. 3-11-15 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 3-11-16 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 3-11-17 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indoor unit (IDU) compact/standard size of nominal cooling capacity 0.6TR ( 420 cfm )/0.8TR ( 441 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-18 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR (512 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-19 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 1.5TR (512 cfm) to 1.8TR (618 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-20 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-21 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-22 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-23 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.3TR (1165 cfm) to 4.0TR (1218 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-24 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 4.1TR (1218 cfm) to 5.0TR (1624 cfm)of suitable cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-25 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 0.6TR (420 cfm) to 0.8TR ( 441 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-26 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.0TR ( 441 cfm ) to 1.3TR ( 512 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-27 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.4TR ( 512 cfm ) to 1.7TR ( 618 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-28 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.8TR (565 cfm ) to 2.0TR (618 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-29 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.1TR (671 cfm ) to 2.7TR (918 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-30 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.8TR (1130 cfm) to 3.7TR ( 1377 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-31 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 2 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.8TR (1377 cfm ) to 4.7TR (1624 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-32 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 0.6TR (420 cfm) / 0.8TR (441 cfm having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-33 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.0TR (441 cfm) to 1.3TR (512 cfm to 530 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-34 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.4TR (512 cfm) to 2.0TR (618 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation.. 3-11-35 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 1 way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 1.8TR (575 cfm) to 2.7TR (953 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for costal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 3-11-36 Supply, installation, testing and commissioning of VRF/VRF based concealed split ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 0.8TR (280 cfm) to 1.1TR (400 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area. Unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-37 Supply, installation, testing and commissioning of VRF/VRF based concealed split ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 1.2TR(400 cfm) to 1.7TR (600 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area. Unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete . 3-11-38 Supply, installation, testing and commissioning of VRF/VRF based concealed split ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 1.8TR (600 cfm) to 2.0TR (800 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area. Unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-39 Supply, installation, testing and commissioning of VRF/VRF based floor/ceiling suspended dual mount type, room/indoor unit (IDU) having nominal cooling capacity of 0.8TR(280 cfm) to 1.1TR (400 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU should have anti-corrosive coating suitable for costal area. unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-40 Supply, installation, testing and commissioning of VRF/VRF based floor/ceiling suspended dual mount type, room/indoor unit (IDU) having nominal cooling capacity of 1.2TR (400 cfm) to 1.5TR(600 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU should have anti-corrosive coating suitable for costal area. unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-41 Supply, installation, testing and commissioning of VRF/VRF based floor/ceiling suspended dual mount type, room/indoor unit (IDU) having nominal cooling capacity of 1.2TR (600 cfm) to 1.5TR (800 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU should have anti-corrosive coating suitable for costal area. unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-42 Supply, installation, testing and commissioning of VRF/VRF based floor/ceiling suspended dual mount type, room/indoor unit (IDU) having nominal cooling capacity of 2.1TR (800 cfm) to 2.6TR (1000 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU should have anti-corrosive coating suitable for costal area. unit shall be of decorative slim dimension suitable for ceiling suspended having an electronic control console with providing any additional refrigerant and oil charge as per requirement during installation complete. 3-11-43 Supply, installation, testing and commissioning of VRF/VRF based floor/ceiling suspended dual mount type, room/indoor unit (IDU) having nominal cooling capacity of 3.2TR (1200cfm) to 3.6TR(1400 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU should have anti-corrosive coating suitable for costal area. unit shall be of decorative slim dimension suitable for ceiling suspended having an elect 3-11-44 Supply, installation, testing and commissioning of VRV/VRF based floor mount type vertical, room/indoor unit (IDU) having nominal cooling capacity of 2.2TR (420 cfm) to 2.3TR (560 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area with decorative slim dimension with an electronic control console, additional refrigerant and oil charge as per requirement during installation complete. 3-11-45 Supply, installation, testing and commissioning of VRV/VRF based floor mount type vertical, room/indoor unit (IDU) having nominal cooling capacity of 2.8TR (1000 cfm) to 3.2TR (1200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area with decorative slim dimension with an electronic control console, additional refrigerant and oil charge as per requirement during installation complete. 3-11-46 Supply, installation, testing and commissioning of VRV/VRF based floor mount type vertical, room/indoor unit (IDU) having nominal cooling capacity of 4.0TR (1400 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area with decorative slim dimension with an electronic control console, additional refrigerant and oil charge as per requirement during installation complete. 3-11-47 Supply, installation, testing and commissioning of VRV/VRF based floor mount type vertical, room/indoor unit (IDU) having nominal cooling capacity of 5.0TR (1624 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for costal area with decorative slim dimension with an electronic control console, additional refrigerant and oil charge as per requirement during installation complete. 3-11-48 Supply, installation, testing and commissioning of VRV / VRF based floor mount type package, room/indoor unit (IDU) having nominal cooling capacity of 8.0TR (3200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, corded remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area with decorative slim dimension suitable floor mounting arrangement, an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-49 Supply, installation, testing and commissioning of VRV / VRF based floor mount type package, room/indoor unit (IDU) having nominal cooling capacity of 10.0TR (4000 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, corded remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area with decorative slim dimension suitable floor mounting arrangement, an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-50 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 0.8TR (280 cfm) to 1.5TR (600 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-51 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 2.1TR (800 cfm) to 2.4TR (960 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-52 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 2.5TR (980 cfm ) to 3.0TR (1200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-53 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static indoor unit (IDU) having nominal cooling capacity 3.1TR ( 1240 cfm )to 4.0TR ( 1600 cfm ) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area, with suitable ceiling suspension arrangement, with an electronic control console and any additional refrigerant and oil charge as per requirement during installation connected with the system complete. 3-11-54 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 4.1TR (1640 cfm) to 5.0TR (2000 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-55 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 5.1TR (2040 cfm) to 6.0TR 2400 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-56 Supply, installation, testing and commissioning of VRV / VRF based ductable type, high static room/indoor unit (IDU) having nominal cooling capacity of 8.0TR (3200 cfm) having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area and decorative slim dimension suitable for ceiling suspended arrangement with an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. 3-11-57 Supply, installation, testing and commissioning of VRV/VRF based ceiling suspended 4.0TR treated fresh air (TFA) (3310 cfm) room/IDU with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for costal area with decorative slim dimension suitable ceiling suspended arrangement and an electronic control console with any additional refrigerant and oil charge as per requirement during installation complete. 3-11-58 Supply, installation, testing and commissioning of VRV/VRF based ceiling suspended 6.5TR treated fresh air (TFA) (5380 cfm) room/IDU with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power having anti-corrosive coating suitable for costal area with decorative slim dimension suitable ceiling suspended arrangement and an electronic control console with any additional refrigerant and oil charge as per requirement during installation complete. 3-11-59 Supply, installation, testing and commissioning of VRV / VRF based ceiling suspended 8.0TR (6600 cfm) to 10.0TR (8200 cfm) Treated Fresh Air (TFA) (5380 cfm) room/IDU with evaporator fan with motor, copper tube, aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, cordless remote control with necessary controls and electrical terminal to receive power . having anti-corrosive coating suitable for costal area with decorative slim dimension suitable ceiling suspended arrangement and an electronic control console with any additional refrigerant and oil charge as per requirement during installation complete. 3-11-60 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 300cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete. 3-11-61 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000cfm capacity with maintaining the static pressure minimum 20mm suitable to operate on 1ph, 230 V, 50Hz, A.C. supply complete. 3-11-62 Supplying and erecting circular flexible/rigid PVC pipe duct of size 40mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 3-11-63 Supplying and erecting circular flexible/rigid PVC pipe duct of size 50mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 3-11-64 Supplying and erecting circular flexible/rigid PVC pipe duct of size 80mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete . 3-11-65 Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers, filters at position complete. 3-11-66 Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 3-11-67 Supplying and erecting circular flexible/rigid PVC pipe duct of size 200mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 3-11-68 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 40mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete . 3-11-69 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 50mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete. 3-11-70 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 80mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete. 3-11-71 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 100mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete. 3-11-72 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 150mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete. 3-11-73 Supplying and erecting an air flow regulating valves/dampers in provided flexible or rigid duct/pipe of 200mm size with an alteration for existing flexible PVC pipe duct and necessary joints, sealing, couplings at position complete. 3-11-74 Supply, installation, testing and commissioning air curtain of 3feet width having air throw velocity of 12 to 14m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9feet, working on 1 phase, 230V, 50Hz, A.C. supply. 3-11-75 Supply, installation, testing and commissioning air curtain of 4feet width having air throw velocity of 21m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9feet, working on 1 phase, 230V, 50Hz, A.C. supply. 3-11-76 Supply, installation, testing and commissioning air curtain of 6feet width having air throw velocity of 21 m/sec, low noise level up to 38 to 46dBA suitable for door height upto 9feet, working on 1 phase, 230V, 50Hz, A.C. supply. 3-11-77 Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 3-11-78 Supply, installation, testing and commissioning wireless remote control having colour LCD panel, real time clock, temperature limitation (16 to 30° C, functions like filter clean reminder timer suitable to communicate with wired controller complete. 3-11-79 Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. 3-11-80 Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. 3-11-81 Supply, installation, testing and commissioning of volume control box with collar for control damper of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. 3-11-82 Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit/dampers/ducting of suitable size with fire resist flexible double canvas sleeve complete. 3-11-83 Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC- 2007. 3-11-84 Providing and applying of acoustic insulation for air ducts with 25mm thick, 48kg/cu.m fiber glass faced with RP tissue and covered with 26SWG perforated aluminium sheets complete. 3-11-85 Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. 3-11-86 Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnut complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. 3-11-87 Supplying and installing of collar damper of galvanised iron material of upto 120microns for anti corrosive resistance for supply air grill of suitable size 3-11-88 Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45°. 3-11-89 Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-90 Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-91 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-92 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiation with OEM standards of VRV/VRF air conditioning system complete. 3-11-93 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-94 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-95 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-96 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3-11-97 supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 3.12 Dismantling 3-12-1 Dismantling the existing electric geyser or storage type water heater of any size along with plumbing connections and making the site clear. 3-12-2 Dismantling the existing window type air conditioner of any type and capacity safely without any damages and making the site clear. 3-12-3 Dismantling the existing split type air conditioner of any type and capacity safely without any damages and making the site clear. Note : The rates for item no 3.12.1 to 3.12.3 are inclusive of dismantling and handing over to section office inclusive of transportation upto 25 km between site and section office. 4.1 Solar hot water system (ESD-SHWS) 4.2 Pipes for solar hot water system (ESD-HWP) 4.3 Solar Batteries (ESD-SOL/BAT) 4.4 Rooftop off grid solar systems (ESD-RT-OFG) 4.5 Rooftop ON grid solar systems (ESD-RT-ONG) 4.6 Heat Pump (ESD-HP) 4.7 Electric Vehicle charger (ESD-EVC) 4.8 Miscellaneous 4.9 Dismantling 4-9-1 Dismantling the existing solar water heating system upto 500 LPD capacity along with piping etc. from roof top and bringing down to ground. 5.1 Change Over Switch, SDF (SW-SWR) 5.2 Mini Feeder Pillar (SW-MFP)/ Street Light Control Panel (SWSTCP) 5.3 LT - MCBs/ MCB Change Over Switch (SW-MCB) 5.4 LT - MCBDBs (SW-MCBDB) 5.5 LT - MCCBs (SW-MCCB) 5.6 RCCB / RCBO (SW-RCCB/RCBO) 5.7 MCCB Panel Boards and Accessories (SW- MCCBPB 5.8 LT - Air Circuit Breakers (SW-ACB) 5.9 HT SF6 Load Break Switch /VCB/RMU (SW-HTS) 5.10 Accessories 10-1 Supplying and erecting HC pattern porcelain fuse bridges with base & HC type fuse links 240V, 16A erected on polished wooden block. 10-2 Supplying and erecting HC pattern porcelain fuse bridges with base & HC type fuse links 240V, 32A erected on polished wooden block. 5-10-3 Supplying & erecting fuse bridge with base 16A erected on provided switch board complete. 5-10-4 Supplying & erecting fuse bridges with base HC type fuse links 240V, 63A erected on polished wooden block. 5-10-5 Supplying & erecting fuse bridges with base HC type fuse links 415V, 100A erected on polished wooden block. 5-10-6 Supplying & erecting fuse bridges with base HC type fuse links 415V, 200A erected on polished wooden block. 5-10-7 Supplying & erecting fuse bridges with base HC type fuse links 415V, 300A erected on polished wooden block. 5-10-8 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 32A without fuse. 5-10-9 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 63A without fuse. 5-10-10 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse up to 100A without fuse. 5-10-11 Supplying & erecting HRC fuse cartridge 415V, 32A 5-10-12 Supplying & erecting HRC fuse cartridge 415V, 63A 5-10-13 Supplying & erecting HRC fuse cartridge 415V, 100A 5-10-14 Supplying & erecting HRC fuse cartridge 415V, 200A 5-10-15 Supplying & erecting HRC fuse cartridge 415V, 300A 5-10-16 Supplying & erecting HRC fuse cartridge 415V, 400A 5-10-17 Supplying & erecting 415V, 16A porcelain base neutral link complete erected in provided M.S. box. 5-10-18 Supplying & erecting 415V, 32A porcelain base neutral link complete erected in provided M.S. box. 5-10-19 Supplying & erecting 415V, 63A porcelain base neutral link complete erected in provided M.S. box. 5-10-20 Supplying & erecting 415V, 100A porcelain base neutral link complete erected in provided M.S. box. 5-10-21 Supplying & erecting 415V, 200A porcelain base neutral link complete erected in provided M.S. box. 5-10-22 Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A 5-10-23 Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 200/300A 5-10-24 Supplying & erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 400A 5-10-25 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 32A 5-10-26 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 63A 5-10-27 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 100A 5-10-28 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 160A 5-10-29 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 200A 5-10-30 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 250A 5-10-31 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 315A 5-10-32 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 400A 5-10-33 Supplying and erecting DIN Type HRC Fuse cartridge 500V, 630A 5-10-34 Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, upto 160A 5-10-35 Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, above 160A- 250A 5-10-36 Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, above 250A- 400A 5-10-37 Supplying and erecting Fuse Base for DIN type HRC Fuse cartridge 500V, above 400A- 630A 5.11 Accessories for MCCB's 5-11-1 Supplying and erecting terminal spreaders suitable for 3 pole, upto 100A MCCB (set of 6) 5-11-2 Supplying and erecting terminal spreaders suitable for 3 pole, upto 250A MCCB (set of 6) 5-11-3 Supplying and erecting terminal spreaders suitable for 3 pole, upto 400A MCCB (set of 6) 5-11-4 Supplying and erecting terminal spreaders suitable for 3 pole, upto 630A MCCB (set of 6) 5-11-5 Supplying and erecting terminal spreaders suitable for 3 pole, upto 800A MCCB (set of 6) 5-11-6 Supplying and erecting terminal spreaders suitable for 4 pole, upto 100A MCCB (Set of 8) 5-11-7 Supplying and erecting terminal spreaders suitable for 4 pole, upto 250A MCCB (Set of 8) 5-11-8 Supplying and erecting terminal spreaders suitable for 4 pole, upto 400A MCCB (Set of 8) 5-11-9 Supplying and erecting terminal spreaders suitable for 4 pole, upto 630A MCCB (Set of 8) 11-10 Supplying and erecting terminal spreaders suitable for 4 pole, upto 800A MCCB (Set of 8) 11-11 Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for upto 200A MCCB with inbuilt CTs. 11-12 Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for above 200A upto 400A MCCB with inbuilt CTs. 11-13 Supplying and erecting earth fault module for MCCB with adjustable earth fault sensitivity selection 10% to 50% of nominal current (In) and adjustable time delay 100/200 millisecond suitable for above 400A upto 800A MCCB excluding CTs. 11-14 Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for upto 250A MCCB. 11-15 Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 250A upto 630A MCCB. 11-16 Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for above 630A upto 800A MCCB. 11-17 Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for upto 100A MCCB. 11-18 Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for 125A to 200A MCCB. 11-19 New) Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for 250A to 315A/320A MCCB. 11-20 New) Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for 400A to 630A MCCB. 11-21 New) Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for 800A MCCB. 5.12 Dismantling 5-12-1 Dismantling the existing switchgears, DB, and bus bar of any size complete with/without board or angle iron frame 5-12-2 Making the site clear of dismantled DB and switchgears by refilling the holes with cement mortar & finishing in an approved manner. 5-12-3 Dismantling existing OCB, ACB, LBS, VCB complete from existing panel board in an approved manner. 5-12-4 Dismantling any type of unserviceable feeder pillar, switchgear panel, capacitor panel, metering panel, bus-bar panel, electronic equipment panel, etc. and making the site as required, approx. size (upto 150 cm x 70 cm x 45 cm ) - Small Cupboard 5-12-5 Dismantling any type of unserviceable feeder pillar, switchgear panel, capacitor panel, metering panel, bus-bar panel, electronic equipment panel, etc. and making the site as required, approx. size (upto 200cm. x 90 cm x 45 cm and above) - Big Cupboard Chapter 6 : CONTROL PANEL (CP) 6.2 Bus bars (CP-BB) 6.3 Sandwich Busbar Trunking System (CP-BBT) 6.4 Air Insulated Busbar Trunking System (CP-BBT) 6.5 Measuring Instruments (CP-MI) 6.6 H. T. Metering (CP-HT) 6.7 Accessories 6-7-1 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box/panel and duly connecting with necessary PVC wire leads and lugs. 6-7-2 Supplying, erecting, testing & commisioning LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. 6-7-3 Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. 6-7-4 Supplying, erecting, testing & commisioning 525 V 3 phase, 50 Hz., APP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of all polypropylene condensers (APP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee. 6-7-5 Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. 6-7-6 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. 6.8 Surge Protective Devices (CP-SPD) 6-8-1 Supplying, erecting & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-2 Supplying, erecting & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 100 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-3 Supplying, erecting & marking of surge arrestor / surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-4 Supplying, erecting & marking of surge arrestor/ surge protection device at the main distribution board after the incoming breaker of type 1+2 tested for Imax 50 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-5 Supplying, erecting & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-6 Supplying, erecting & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 40 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-7 Supplying, erecting & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 15 kA for single phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD 6-8-8 Supplying, erecting & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested for Imax 15 kA for three phase and neutral with compliance to IEC 61643-11 as per specification no. CP-SPD Note:- The above items shall be used only in erectings where sensitive instruments are used and installations that are prone to surges. 6.9 Energy Devices (APFC Panel) (CP-ED/APFC) 6-9-1 New) Supplying, erecting, testing & commisioning 10 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 1,1,2,2,4 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC 6-9-2 New) Supplying, erecting, testing & commisioning 15 kVAr, 440V, 3 phase, 50 Hz, APFC panel with contactor logic with intelligent microprocessor relay, consisting of 1,2,2,2,4,4 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard per specification no. CP-ED/APFC. 6-9-3 (New) Supplying, erecting, testing & commisioning 25 kVAr, 440 V, 3 phase, 50 Hz., APFC panel with contactor logic with intelligent microprocessor relay, consisting of 1,2,2,5,5,5,5 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard per specification no. CP-ED/APFC. 6-9-4 Supplying, erecting, testing & commisioning 30 kVAr, 440 V, 3 phase, 50 Hz., APFC panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,5,10 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-5 Supplying, erecting, testing & commisioning 40 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,5,10,10 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-6 Supplying, erecting, testing & commisioning 50 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,3,5,5,7,10,15 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-7 Supplying, erecting, testing & commisioning 75 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,10,10.20,20 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-8 Supplying, erecting, testing & commisioning 100 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,10,20.20,20,20 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-9 Supplying, erecting, testing & commisioning 125 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,10,20,20,20,20,20 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-10 Supplying, erecting, testing & commisioning 150 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,10,10,15,20,30,50 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-11 Supplying, erecting, testing & commisioning 175 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,5,10,10,15,25,50,50 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-12 Supplying, erecting, testing & commisioning 200 kVAr, 440V 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 2,3,5,10,10,20,25,25,50,50 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-13 Supplying, erecting, testing & commisioning 250 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with contactor logic with intelligent microprocessor relay, consisting of 3,5,5,7,10,20,20,25,25,30,50,50 or suitable steps of APP/MPP type capacitor units with detuned (harmonic filter) reactors of suitable rating, APFC panel shall be compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-14 (New) Supplying, erecting, testing & commisioning 10 kVAr, 440 V, 3 phase, 50 Hz., APFC Panel with derated power contactor of suitable rating for capacitor switching Application for each step controlled by microprocessor based APFC relay consisting of 1,1,2,2,4 or suitable steps of MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with detuned aluminium wound reactor of 7/ 14% for each step, APFC Panel shall suitable rating MCCB as incomer and each branch/step shall have separate isolation with MCCB/MCB of Suitable rating for protection, compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-15 (New) Supplying, erecting, testing & commisioning 15 kVAr, 440V, 3 phase, 50 Hz., APFC Panel with derated power contactor of suitable rating for capacitor switching Application for each step controlled by microprocessor based APFC relay consisting of 1,2,2,2,4,4 or suitable steps of MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with detuned aluminium wound reactor of 7/ 14% for each step, APFC Panel shall suitable rating MCCB as incomer and each branch/step shall have separate isolation with MCCB/MCB of Suitable rating for protection, compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. 6-9-16 (New) Supplying, erecting, testing & commisioning 25 kVAr, 3 phase, 50 Hz., APFC Panel with derated power contactor of suitable rating for capacitor switching Application for each step controlled by microprocessor based APFC relay consisting of 1,2,2,5,5,5,5 or suitable steps of MPP /APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with detuned aluminium wound reactor of 7/ 14% for each step, APFC Panel shall suitable rating MCCB as incomer and each branch/step shall have separate isolation with MCCB/MCB of Suitable rating for protection, compliance to IEC 61439 and power quality IEC 61921 standard as per specification no. CP-ED/APFC. Chapter 7 : CABLES (CB) 7.1 LT Cables (Aluminum) (CB-LT/AL) 7.2 LT Cables (Copper) (CB-LT/CU) etc
|