Tender For Work Of Augmentation Of Uwss Todaraisingh, District Tonk Including 5 Years O And M Under Cm Budget Announcement. - Water Supply Scheme for Augmentation of UWSS Todaraisingh, District Tonk including 05 Years O&M after 01 year Defect Liability Period under Modified Budget Announcement (2024-25) Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 2 100 mm 3 150 mm 4 200 mm 5 250 mm 6 350 mm 7 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. HDPE PE-100PN-6 8 90 mm dia 9 110 mm dia 10 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M. HDPE PE-100PN-6 11 125 mm dia 12 140 mm dia 13 160 mm dia 14 Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethyleneincluding preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge.Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface. 15 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 16 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 17 MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) 18 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 19 25.0 Sq.mm, 3.5 core 20 35.0 Sq.mm, 3.5 core 21 Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: - 22 a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type). 23 k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 22 M 24 200KL capacity 25 300KL capacity (2 nos) 26 Laying and Jointing PVC Pipe. Heading 27 Laying and Jointing PVC Pipe. Heading 28 Laying and Jointing PVC Pipe. Heading 29 500 KL capacity 30 Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work. 31 100 mm 32 150 mm 33 200 mm 34 250 mm 35 350 mm 36 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 37 In All Typeof Soil 38 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: 39 Ordinary rock 40 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 41 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. (M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 42 Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coilincluding excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work, but excluding the cost of pipe line. 43 Providing, installation, testing and commissioningof Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class F insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 44 75 KW 45 Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at synchronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 46 Discharge 20 to 30 LPS and head 71 to 80 M 47 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 48 50 mm 49 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 50 150 mm dia 51 200 mm dia 52 400 mm dia 53 Providing,lowering,aligning,fixinginpositioninpipelineatworksite,DID/F Resilientseated(softseated)SluiceValves(GateValves),Vacuumtight(bubble tight), straight and pocket less body passage of approved make of following class & diacompleteconfirmingtoBS-EN-1171/AWWAC-509andoffollowing specifications:Body & bonnet ofDuctile castiron ofgrade GGG40/GGG50as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2 1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to facedimensionsasperBS5163-89/IS14846/2000(amendeduptodate)/Din 3202F4,Stem/spindleofSSAISI316/410Electrostaticepoxypowder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thicknessof250micronsinsideandoutside,DrilledasperIS1538.Nut-Bolt confirmingtoIS:1363andIS:1367 (Galvanisedsteel)Insertionrubberofblack EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves includingall jointing& jointingmaterial, labour,testingandcommissioningalong withpipelineasperTechnicalSpecificationsandasperdirectionofEngineer-in- charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 54 100 mm dia 55 125 mm dia 56 150 mm dia 57 200 mm dia 58 250 mm dia 59 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 60 100 mm dia 61 150 mm dia 62 200 mm dia 63 250 mm dia 64 350 mm dia 65 200 mm dia 66 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR O ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel)Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 67 150 mm dia 68 Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 69 150mm dia 70 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 71 100 mm dia. 72 125 mm dia. 73 150 mm dia. 74 200 mm dia. 75 250 mm dia. 76 350 mm dia. 77 400 mm dia. 78 Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint(FabricatedSteel) asperISspecifications complete of the following sizes including alljointingmaterial, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. 79 100 mm dia. 80 150 mm dia. 81 200 mm dia. 82 250 mm dia. 83 Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx. 84 Type I ( 72.3 Sqm) 85 Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonry in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done. 86 Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints. 87 Providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre center to center with 0.40 metre embedded in M15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects including all material, labour. 88 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. For in-campus Valve Chambers 89 Sluice valve chamber of size1.13m x0.85m x1.225mfor pipe size-upto100mm 90 Sluice valve chamber of size1.17m x0.95m x1.37mfor pipe size-from 125-to-150mm 91 Sluice valve chamber of size1.26m x1.185m x1.76mfor pipe size-from 200-to-300mm 92 For Class-AA loading 93 Sluice valve chamber of size 1.39m x1.43m x2.245m for pipe size-from 350-to-450mm 94 For in-campus Valve Chambers 95 Sluice valve chamber of size1.39m x1.43m x2.125mfor pipe size-from 350-to-450mm 96 Construction of RCC Air valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. For Class-A loading 97 Air valve chamber of size0.9m x1m x1.71mfor air valve size-from 50 mm-to-80mm 98 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. 99 Air valve pillarfor airvalves size of 80mmdia 100 SITC ofUltrasonic Level Transmitter suitable for measuring water levelin reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %,as per detailed Technical specification, scope of work and direction of Engineer in charge. 101 Measuring range 0.0 to 6.0 mtr 102 SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 103 EFM100 mm 104 EFM 150 mm 105 Design, construction,testing and commissioning ofRapid Gravity Filter Treatment Plant including all relevant civil, electrical , mechanical ,instrumentation, automization and SCADA works, chemical building and stores along with ancillary civil works as defined in scope of work, technical specification and provisions of CPHEEO manuals for the following capacity . 106 Cost of 200 KLH 107 Add per KLH above 200 KLH and upto 500 KLH 108 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer 109 Rubble stone masonry in cement mortar. 110 Steel work in all type sections up to a height of 5 metre above plinth level (Riveted work where rivet are required to be cut shall be measured and paid separately) 111 Excluding dismembering 112 Extra for cutting rivets in built up steel sections. 113 SITC of Soft Starters with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. 114 37 KW 115 75KW 116 Design, Manufacture, Supply, Installation, Testing and Commissioning of Indoor type PLC Panel of size approx. 800 mm X 500 mm X 2000mm (LBH) , Fabricated out of min. 2 mm thick CRCA sheet complete with latest configuration, necessary programming software for PLC & SCADA and comprising of all accessories not limited to the following: DI 46 No.DO 42 No. AI 10 No. AO 4 No. MCB 16A DP 2 No. MCB 6A DP 6 No.SMPS 100-240VAC/ 4.5A / 24 VDC 1 No. Selector Switch (Auto/Manual) & Local / Remote 2 No. Control Relays 1 Lot Annunciator with 24 Windows NO to NC Type Microprocessor Based, Window Size 75*42mm, 110VAC, with 1 No. Electronic Hooter 1 No. Control Transformer 200VA 1 No.Emergency STOP Push Button 1 No. Panel Cooling Fan & Filter 2 No.Panel Light with Door Switch, 7W 1 No.Control Indication Lamp for 24VDC, 220VAC 3 No.Push Button 3 No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc 1 Lot Panel Hardware, lugs, terminations, ferruls, name plate Ect. 1 Lot UTILITY SOCKET 16A, 3 PIN 2 No.HMI Display 10 Inch, Colour 1 No. Isolators Dual Output, 24VDC 1 Lot 117 Cost for Basic Service Charges, Administration and Management, Running of Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 5 years after defect liability period of one year DLP (except power feeder, IEC & miscellaneous provision) for Water Supply project. 118 1st year 119 2nd year 120 3rd year 121 4th year 122 5th year
|