Tender For Addn / Altn To Fms Bldg At Af Stn Halwara; 1 Taking down chowkhats or frame with shutter without taking off shutter from the frame areanot exc 1.5 Sqm each, complete all as specified and directed. 2 All as per item No 1 but area exc 1.5 Sqm but not exc 4 Sqm each. 3 Taking down shutters of any descriptionof sizeexc 1 sqm but not exc 2 sqm each leaf, complete all as specified and directed. 4 S&F Powder Coating aluminium frame for doors, windows,(minimum thickness of powder coating 50 micron) ventilators with one or more rebates including joining cleat for fixing etc, complete all as specified and directed. 5 S&FPowder coated aluminium door shutters, aluminium sectionweighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, handles 2 Nos ineach door,tower bolt, hinges, anodised aluminium snap beading screws (minimum thickness of powder coating 50 micron), complete all as specified and directed. 6 S & FPowder coatingaluminium window and ventilator shutters,side hung/fixed type without sash bars,aluminium sectionweighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, anodised aluminium snap beading screwsanodised aluminium fittings such as peg stay, Tower bolt 150mm long 1 No. hinge type B-21 100 mm long 2 Nos, suitable handle 1 No(minimum thickness of powder coating 50 micron), complete all as specified and directed. 7 S&F Powder coating aluminium grills of any pattern/design, weight not less than 1.5kg per square meter complete all as specified and as directed. 8 S&F 5.5 mm thick sheet glass selected quality plain/ tinted in squares exc 0.5 sqm each pane and fixed, complete all as specified and directed. 9 S&F 4.8mm thick sheet glass selected quality plain/ tinted in squares n.exc 0.5 sqm each pane and fixed, complete all as specified and directed. 10 Demolition of brick work as in walls/parapet walls removing grass fungus weed, roots of trees completely, grown on roof/wall surfaces, complete all as specified and directed. 11 M&L for brick works with sub class "B" bricks straight or curved on plan exc 6m mean radius, built in cement mortar 1:6, complete all as specified and directed. 12 Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed. 13 M&L for rendering15mm thickin cement mortar 1:4 mixed with water proofing compound @ 3% by weight of cement on brick/concrete surfaces, finished fair and even without using extra cement, complete all as specified and directed.Note: WPC shall be measured and paid seperately. 14 M&L for 15 mm thick rendering in cement mortar 1: 6 on brick/concrete surfaces,finished even and smooth without using extra cement, complete all as specified and directed. 15 M&L for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe-290 (Gde E-165), complete all as specified and directed. 16 S&F 2mm thick Fiber glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc, complete all as specified and directed 17 M&L in replacement bird proof nylon net fixing with 4mm dia GI wire 600mm X 600mm mesh made up intomatteresses ,cages and lapped wire and laid in positionwith suitable arrangement etc complete in side of hangers and as approved by GE, complete all as specified and directed.Note :-The pattern and size of nylon rope/net will be approved by GE. 18 Dismantling brick tiles or terracing tiles, single layer on roof complete all as specified and directed. 19 Demolition of Concrete of any description and in anypositionnot otherwise specifically provided for roof complete all as specified and directed. 20 M&L for Roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, etc and brushing neat cement slurry @ 3.00 Kg/Sqm complete all as specified and directed. 21 M&L foravg 50mm thick cementconcrete type B-1, 1:2:4 (20mm graded aggregate) PCC padding to be provided to maintain slope of roof complete all as specified and directed. 22 M&L for screeding 10mm thick on fair faces of concrete surfaces in cement mortar 1:4 with waterproofing compound as per manufacturer"s instructions, finished even and fair as in roof shall be complete all as specified and directed.. Note : water proofing compound will measured and paid separately under respective item 23 Supply only intergal waterproofing compound complete all as specified and directed. 24 M&L for preparation of roof top surfaces, providingand applying single component elastic cold applied polyurethene modified acrylicroofing system ,co elastic technology (CET) based on modified polyurethene and fully fibrereinforced , having Sun Reflectivity index (SR) of 106 on top of concrete roof surfaces. All cracks upto 3 mm at corner joints, channel and parapets should be treated with crack seal . Applying three coatsincluding one coatof primer of STP Ltd"s, Shali Urethne BTD/Sika"s Sikalastic 560/Asian Paint"s smart care damp proof ultra having coverage @ min 0.75kg/m2and dilution upto 10% andlaying reinforced fibre net and applying two coats of STP Ltd"s, Shali Urethne BTD/Sika"s Sikalastic 560/Asian Paint"s smart care damp proof ultra@totalconsupmtion 2 kg/m2intwo coats for maintainingminimum dry filmthickness 1.5mm and elongation at breakof free film of approx 350%. The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge/as per manufacture"s instructions.Note : (i) 6 Hrs interval between two coat will be mantain.(ii) . All auxilary and accessories involved during applacation should be supplied by single manufacturer as a part of system.(iii) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators duly approved by GE in writing.(iv)5% amount of the total amount of water proofing treatment shall be retained as a guarantee and shall be released after 10 years. However contractor may deposit the FDR of same amount in favour of GE. If contractor fail to rectify the defect pointed out during this period in writing, the defect shall be got rectified at contractor" risk and cost and the payment shall be made from the amount kept reserved or by encashing the FDR deposited by the contractor as guarantee. The contractor"s quoted rates for this item shall deemed to be inclusive of this aspect 25 M&L PCC (1:2:4) type B-1 using 20 mm graded stone aggregates providing ,cement concrete in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. 26 S&F in repair 110mm dia bore PVC (SWR) pipe single socketed in any length with rubber ring jointes fixed to walls complete all as specified and directed. 27 S&F 110 mm dia bore PVC (SWR) bends complete all as specified and directed. 28 Demolition of cement concrete (unreinforced) in ground floors and paving’s n exc 15cm thickness below or above ground leveland removing the same out side MoD land complete all as specified and directed. 29 Excavating in trenches n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on planand getting out in soft loose soil complete all as specified and directed. 30 Rough excavation n. exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. 31 Rough excavation . exc 1.5 m deep but n exc 3m and getting out in soft/loose soil complete all as specified and directed. 32 Removing surplus soil to a distance exc 500m but not exc. 1.5 Km and depositing where directed at a level not. exc 1.5m above the starting point complete all as specified and directed. 33 M&L for hardcore of broken stone or boulders of gauge n exc 63 mm mixed with atleast 30% stone dust of size less than 75 micron deposited , spread and levelled in layersn exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. 34 M&L 75mm thick cement concrete type D-2, (1:4:8) (using 40 mm graded stone aggregates) laid in base of the foundations complete all as specified and directed. 35 M&L for priming surfaces and applying normal treatment(for moderate condition) using bitumen primer@0.30kg/sqm applied hot complete all as specified and directed 36 M&Lfor applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg/sqm including cleaning of surfaces complete all as specified and directed 37 M&L for water proofing work with APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick, reinforced with polyster non woven fabric (weight not less than 150gms/sqm laid on primed surface by torched application complete all as specied and directed.NOTE: (i) The water proofing treatment shall be got carried out by the manufacturer or their authorisedapplicators duly approved by GE in writing(ii) 5% amount of the total amount of water proofing treatment shall be retained as agurantee ( on account of any defect raised/noticed during a period of ten years) and shall be released after 10 years of completion work. however contactor may deposit the FDR of same amount in favour of GE.if contractor fail to rectify the defect pointed out during this period ,the defect shall be got rectified at contractor risk and cost and the payment shall be made from the amount kept reserve or by encashing the FDR deposited by the contractor as gurantee. The contractor quoted rates for this item shall deemed to be inclusive of this aspect. 38 M&L for 75mm thick cement concrete type B-0, (1:2:4),( using 12.5 mm graded stone aggregates),laid in plinth level even and smooth concrete surface without using extra cement complete all as specified and directed. 39 Dewatering/desludging of drains, septic tanks, soakage wells etc using Sewage waste collection Truck/Vehicleincluding cleaning of all sludge, silt residue of both organic and inorganic nature by mechanical scrappers etc/mechanical means only and disposal off the same out side the defence areawithout causing any nuisence to Air Force community/civil public andin confirmity with the regulations of local authorities, with out any extra cost to Govt, complete all as specified and directed.Note :- 1. For measurement of cubic content of sludge please refer PS Clause No 24.1.2. Work shall be carried out in foul conditions.After dewatering, sewage systems shall be allowed to dry . 3. Sewage/ sullage shall be removed in closed container mounted on vehicle.4. Work shall be carried out as and when required.5. Work will done only when one supervisor is present at site who will be responsible for ensuring safety of the labours engaged. 6.All safety device/measures to the workmen shall be provided by the contractor before execution of work. 40 M&L 75 mm thick PCC 1:3:6 type C1 (using 20mm graded stone agg) as in surface channels and drains including smooth finish complete all as specified and directed. 41 M&L for brick work with sub class B bricks in one brick thick honey comb walling ,builtin cement mortar 1:6 complete all as specified and directed. 42 M&L for sand filling under floors or in foundation complete all as specified and directed. 43 M&L for loose filling with broken bricks of gauge 80 to 150 mm in sokage pits , sokage well etc complete all as specified and directed. 44 M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required, incl cranking bending, spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 45 M&L formwork for flat suspended slabs such as roof slabs , floor slabs ,landing and similar work n exc 200 mmthick (horizantal and sloping ) complete all as specified and directed. 46 M&L for RCC M-25 design mix using 20mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 47 M&L for preparation of new plastered surfaces of wall and applying two coats of exterior acrylic emulsionpaint over a coat of primer in camouflage pattern, using minimum 3 different approved tint/ colour complete all as specified and directed. 48 M&L for preparation of newplastered surfaces of wall and applying three coats ofwhite wash complete all as specified and as directed. 49 M&L prepration of new plaster surface on any description,concrete,brick ,stone etc exceeding 10 cm in width or girth applying two coat of black japan paint complete all as specified and directed. 50 M&L prepration of old painted surface of any description wood, steel ,iron ,concrete,brick ,stone etc exceeding 10 cm in width or girth applying two coat of acid resistant paint complete all as specified and directed. 51 M&L for preparation of old plastered surfaces of wall and applying two coats ofdistemper oil emulsioncomplete all as specified and as directed. 52 Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness including cover fillets of any description complete all as specified and directed. 53 S&F 4mm thick designer fiber cement ceiling tile of size 595mm*595mm in ceiling fixed with screw,u angle ,Tee and all other accessories which willrequired to fixing the ceiling as per manufacturers instructions,complete all as specified and as directed 54 S&F 5mm thick any colour/ designPVC hollow block wall panelling along with pvc angle ,corner, strips etc required as per site complete all as specified and directed. 55 Dismantling floor hearth or wall tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 56 M&L for 25mm thick PCC type B-0 using 12.5mm graded crushed stone aggregate as in sub base finished even and fair surfaces without using extra cement complete all as specified and directed. 57 M&L for 15mm thick screed bed or bedding layer of mortarfor laying floor finished in cement mortar 1: 6 complete all as specified and directed.. 58 M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 rough finished surfaces complete all as specified and directed. 59 M&L for 9 to 10mm thick Vitrified ceramic tiles light shade mat finish (Square/Rectangular) polished, area of each tiles n. exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles complete all as specified and directed. 60 All as per Sl item Ser No.59 above but as in skirting, dados/Vertical surfaces etc. 61 S&F Aluminium (Die cast) body Door closer hydraulicaly regulated ,designation No 3, uiversal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixing complete all as specified and directed. 62 S&F Harrison rails, mild steel ,chromium plated with fixing brackets , stop ,rollers etc complete all as specified and directed.
|