Tender For Renovation Up gradation Works In Tdc; 1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. 2 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 4 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) 6 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specification. 7 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) 10 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 11 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 12 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 13 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 14 12 mm cement plaster: 1:4 (1 cement : 4 fine sand) 15 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) 16 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 17 Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work 18 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 19 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 20 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 21 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. 22 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 23 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal ofunserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 24 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 25 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 26 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) 27 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC15) 28 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides 29 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight notless than 12.50 kg/ sqm) 30 Panelling 31 Providing, Fixing and Installation of Solid Double Skin Clean Room Wall cladding panels 80mm thick, Powder Coated (60-80 microns) Galvanized Iron sheet (hot dipped with zinc coating of 120gsm) on both side with Infill material as PIR (Density 40 kg/m3) with all required accessories like C Type Floor Track, Top Channels, male female channel etc with installation as per Thrislington Standards. Both side PCGI of size 0.6mm thick 32 One side SS-304 0.8mm/ One Side PCGI 0.6mm 33 Providing, Fixing and Installation of Solid Double Skin Clean Room Wall cladding panels 50mm thick, Powder Coated (60-80 microns) Galvanized Iron sheet (hot dipped with zinc coating of 120gsm) on both side with Infill material as PIR (Density 40 kg/m3) with all required accessories like C Type Floor Track, Top Channels, male female channel etc with installation as per Thrislington Standards.Both side PCGI of size 0.6mm thick 34 Providing, Fixing and Installation of Solid Double Skin Clean Room walkable ceiling panels80mm thick, Powder Coated (60-80 microns) Galvanized Iron sheet (hot dipped with zinc coating of 120 gsm) on both side with Infill material as PIR (Density 40 kg/m3) with all required accessories like Channels, male female etc including all trusses hanging arrangement as per load requirement with installation as per Thrislington Standards. Both side PCGI of size 0.6mm thick 35 COVING 36 Providing, Fixing and Installation of Aluminium Coving R-50 with Aluminum Backing (Powder Coated) 37 2D & 3 DCorners (Powder Coated) 38 Aluminium Coving R-50 with Aluminum Backing (Metallic Coated) 39 2D Corners (Metallic Coated) 40 3D Corners (Metallic Coated) 41 DOOR Providing, Fixing and Installation of Single DoorScientific Metal Doors designed to fit flush into the wall panel or brick wall. Doors are fabricated from GI sheet duly powder coated (thick 70- 80 micron with approved colour). Leaf having sheet thickness of 0.8mm and the frame of 1.2mm. Infill material will be Paper core with provisions for double glazing toughened glass 400*600mm and hardware"s like door closure (SS ball bearing hinges, SS D handle 250mm with Push plate, Dead lock both side key operated) Aaditya Make or equivalent, Drop Sael and Door Seal D type, SS kick plate 300mm height and concealed tower bolt for the double door etc. 42 Single Leaf Door of size 750 x2100mm 43 Single Leaf Door of size900 x 2100 mm 44 Single Leaf Door of size900 x 2200 mm 45 Single Leaf Door of size 900 x 1950 mm 46 Single Leaf Door of size 1000 x 2100 mm 47 Single Leaf Door of size 1000 x 2200 mm 48 Single Leaf Door of size 1000 x 2050 mm 49 Single Leaf Door of size 1200 x 2600 mm with DOP 50 Single Leaf Door of size 900 x 2600 mm with DOP 51 Double Leaf Door of size 1500 x 2100 mm 52 Single Door 750*2100 Emergency Exit Door with Panic Bar withhardware"s like door closure, SS304 ball bearing hinges, panic bar, Drop Seal, Door seal SS304 kick plate 300mm height etc 53 Single Leaf Door of size 900 x 2600mm with DOP 54 VIEW PENELDouble glazed view panels in wall partitions with flush design fixed with 5mm thick toughened glass, fixed with DA Tape and gap filling, finished with black silicon sealant. Size - 1000*1000mm 55 Hardware for DoorsReturn Air RiserProviding & fixing GI return air riser inside 80 mm thk wall panels. RA duct will extend 150 mm above walk on ceiling with a flanged connection to main Duct by others. Riser will be provided with SS-304 1.2mm thk Perforated Grill.Solid Area will be considered in wall panel area.(With Filter and Damper) 56 Both side PCGI of size 0.6mm thick 57 one side SS-304 0.8mm/ One Side PCGI 0.6mm 58 Double glazed Vision Panel (With SS Capping) 59 Providing, Fixing and Installation of Double Glaze Vision Panelwith 2 x 6 mm thick Clear Toughened glass with 20mm black border with all accessories like double adhesive tape, silicon sealant and silica gel with 0.8 mm GI powder coated inner channel with installation as per Thrislington Standards.(Max. Jamb 80mm) Size 1000 x 1000 mm 60 Cutouts 61 Wall Cutouts for Electrical Fittings (Factory Made) 62 Ceiling Cutouts for Electrical Fittings (Factory Made) 63 Pass Box Cutouts (Factory Made) 64 25mm Dia. MS conduit pipe 65 L Flushing PCGI (50X360MM) 66 L Flushing SS304 (50X360MM) 67 TRUSSES FOR HANGINGARRANGEMENTS T-type MS truss with threaded rod hanger 68 Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed steel conduit, with pianotype switch, phenolic laminated sheet, suitable size MS box andearthing the point with 1.5 sq.mm FRLS PVC insulated copperconductor single core cable etc. as required. Group B 69 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit asrequired. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 70 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mmFRLS PVC insulated copper conductor single core cable for loopearthing as required. 71 Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 A TP&N 72 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB 73 315 A, 35 KA,TPMCCB 74 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing andcommissioning etc.as required.For 4 way, Double door TPN MCBDB 75 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.25 A 76 63 A 77 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,suspended from the ceiling with M.S. suspenders including bolts& nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness 78 600 mm width X 75 mm depth X 2.0 mm thickness 79 Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness 80 600 mm width X 75 mm depth X 2.0 mm thickness 81 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 62.5 mm depth X 2.0 mm thickness 82 600 mm width X 75 mm depth X 2.0 mm thickness 83 Supply, installation, testing and commissioning of followingsizes of cu/ GIstrip/wireclampedto walls,cable trays,busducts, cables, in recess (including cost of digging & backfilling) or on surfaceetc for equipment/ System / Lightning protectionearthing completeas required including interconnectionbetween lengthatjoints, allfixing accessoriessaddles, clamps, test joints etc.andother fixing hardware material as required for proper installation.25 x 5 mm strip of Copper 84 Earthing with copper earth plate 600 mm X 600 mm X 3 mmthick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 85 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 86 Supplying and making end termination with brass compression gland and copperlugs for following size of PVC insulated PVC sheathed/XLPE copper conducter cable of 1.1 kV grade as required. 4 C x 10 sq.mm 87 Main LT Panel a)Main Incomer - 01 No. (b)MCCB 630A 4P 55KA TMR with O/L & S/C Prot -1 (c)Spreader Links - 02 Nos. (d)Rotary Handle - 1 No.(e)Digital MFM Meter - 1 No. (f)Phase Indicating Lamps, LED Type - R-Y-B - 3 Nos. (g)MCB 6A SP 10 kA `C" Curve - 3 Nos. (h)600/ 5A, CL-1.0, 15 VA, Tap Wound CT for Metering - 3 No. (i)CT Shorting Link - 4 Nos (j)Neutral Link - 01 No.(k)Outgoing Feeder (l)MCCB 400A for G.F. Distribution Panel -1(m)MCCB 400A 4P 36KA TMR with O/L & S/C Prot -1 No.n)Spreader Links - 02 Nos.(o)Rotary Handle - 1 No. (p)MCCB 125A 4P for F.F. Distribution Panel - 1 No.(q)MCCB 125A 4P 36KA TMR with O/L & S/C Prot -1 No.(r)Spreader Links - 02 Nos.(s)Rotary Handle - 1 No.(t)MCCB 63A 4P for Clean Room - 1 No.(u)MCCB 63A 4P36 kA TMR with O/L & S/C Prot.- 1 No.(v)Spreader Links - 02 Nos.(x)Rotary Handle - 1 No.(y)MCCB 100A 4P for Spare - 1 No.(z)MCCB 100A 4P 36KA TMR with O/L & S/C Prot -1 (aa)Spreader Links - 02 Nos.(ab)Rotary Handle - 1 No. (ac)MCB 63A 4P for Spare - 3 No.(ad)MCB 63A 4P 10kA `C" Curve- 3 Nos. (ae)MCB 32A 4P for Spare - 3 No.(af)MCB 63A 4P 10kA `C" Curve- 3 Nos.(ag)Aluminium Main Busbar, Dropper and Input & Outpur Links with Heat Shrink Sleeve(ah)Busbar will be electrolytic E-91 High Grade with current rating of 0.8 sqmm :- 800A including earthing & neutral busbar with heat shrink colour coated sleeve - 01 No.(ai)Busbar will be electrolytic E-91 High Grade with current rating of 0.8 sqmm :- 800A including earthing & neutral busbar with heat shrink colour coated sleeve - 01 No.(aj)Hardware (ak)GI Nut, Bolt, Plain and spring washer, DMC Busbar supports etc. - 1 No. (al) MS Enclosure - W-2100MM H-1775MM D-500MM (am)Panel will be fabricated with CRCA sheet 2/1.6mm duly powder coated with RAL 7035 siemens grey paint free standing indoor floor mounting type compartmentalized dust & vermin proof including gland plates, MS channels, MS Partitions, self adhesive rubber gaskets, door hinges, lifting hooks, panels locks with open/ close sticker, rubber grommets, danger plates, insciption name plates and wires for door earthing with thimbles - 01 No. (an)Power & Control Wiring(ao)Power & Control wire including timble, ferrules, tie PVC/ MCB, channels and end plates etc. - 01 No. 88 PDB Panel (Ground Floor) (a)Main Incomer - 01 No. (b)MCCB 400A 4P 36kA TMR with O/L & S/C Prot -1 No. (c)Spreader Links - 02 Nos.(d)Rotary Handle - 1 No.(e)Digital Amp Meter 0-400 A with ASS 1 No.(f)Digital Volt Meter 0-500 A with VSS 1 No. (g)Phase Indicating Lamps, LED Type - R-Y-B - 3 Nos. (h)MCB 6A SP 10 kA `C" Curve - 3 Nos.(i)400/ 5A, CL-1.0, 15 VA, Tap Wound CT for Metering - 3 No.(j)CT Shorting Link - 4 Nos(k)Neutral Link - 01 No.(l) Outgoing Feeder (m)MCCB 125A 4P for Chiller Plant and Brine Plant 50 HP -2 Nos. (n) MCCB 1254P 36 kA TMR with O/L & S/C prot. - 2 Nos. (o) Spreader Links - 04 Nos. (p) Rotary Handle - 2 No.(q) MCB 40A 4P for for Distribution Pump, cooling Tower, Centrifuge, 250 ltr, reactor, 250 ltr blender, AHU 1, AH-4 and AHU-6 - 8 Nos (r) MCCB 40A 4P 10KA `C" Curve - 08 Nos (s) MCB 25A 4P forVaccum Pump, Tray Dryer 24 Tray, VTD 24 TRAY, WH sampling booth and - 5 Nos. (t) MCB 25A 4P 10KA `C" Curve - 5 Nos. (u) MCB 32A 4P forAHU 2, 3 & 5 -3Nos.(v) MCB 32A 4P 10KA `C" Curve - 3 Nos.(x) MCB 63A 4P for Lighting & Spare - 4 No. (y) MCB 63A 4P 10 kA `C" Curve- 4 Nos. (z) MCB 32A 4P for Lighting & Spare - 4 No. (aa) MCB 32A 4P 10kA `C" Curve- 4 Nos.(ab) Aluminium Main Busbar, Dropper and Input & Outpur Links with Heat Shrink Sleeve - 01 No. (ac) Busbar will be electrolytic E-91 High Grade with current rating of 0.8 sqmm :- 500A including earthing & neutral busbar with heat shrink colour coated sleeve - 01 No. (ad) Hardware (ae) GI Nut, Bolt, Plain and spring washer, DMC Busbar supports etc. - 1 No.(af) MS Enclosure - W-2100MM H-1675MM D-500MM (ag) Panel will be fabricated with CRCA sheet 2/1.6sqmm duly powder coated with RAL 7035 siemens grey paint free standing indoor floor mounting type compartmentalized dust & vermin proof including gland plates, MS channels, MS Partitions, self adhesive rubber gaskets, door hinges, lifting hooks, panels locks with open/ close sticker, rubber grommets, danger plates, insciption name plates and wires for door earthing with thimbles. (ah) Power & Control WiringPower & Control wire including timble, ferrules, tie PVC/ MCB, channels and end plates etc. - 01 No. (ai) Power & Control wire including timble, ferrules, tie PVC/ MCB, channels and end plates etc. - 01 No. 89 PDD Panel (First Floor) (a) Main Incomer - 01 No. (b) MCCB 125A 4P 36kA TMR with O/L & S/C Prot -1 No. (c) Spreader Links - 02 Nos. (d) Rotary Handle - 1 No. (e) Digital Amp Meter 0-125 A with ASS 1 No. (f) Digital Volt Meter 0-500 A with VSS 1 No. (g) Phase Indicating Lamps, LED Type - R-Y-B - 3 Nos. (h) MCB 6A SP 10 kA `C" Curve - 3 Nos. (i) 150/ 5A, CL-1.0, 15 VA, Tap Wound CT for Metering - 3 No. (j) CT Shorting Link - 4 Nos (k) Neutral Link - 01 No. (l) Outgoing Feeder (m) MCCB 63A 4P for 20 KW- 01 No. (n) MCCB 63A4P 36 kA TMR with O/L & S/C prot. - 1 No. (o) Spreader Links - 02 Nos. (p) Rotary Handle - 1 No. (q) MCB 63A 4P forLighting & Spare - 2 Nos (r) MCB 63A 4P 10KA `C" Curve - 02 Nos (s) MCB 32A 4P for Lighting & Spare - 2 No. (t) MCB 32A 4P 10 kA `C" Curve- 2 Nos. (u) MCB 20A 4P for Fume Hood -5Nos. (v)MCB 20A 4P 10KA `C" Curve - 5 Nos.(x) Aluminium Main Busbar, Dropper and Input & Outpur Links with Heat Shrink Sleeve- 01 No. (y) Busbar will be electrolytic E-91 High Grade with current rating of 0.8 sqmm :- 500A including earthing & neutral busbar with heat shrink colour coated sleeve - 01 No. (z) Hardware (aa) GI Nut, Bolt, Plain and spring washer, DMC Busbar supports etc. - 1 No. (ab) MS Enclosure - W-1200MM H-1575MM D-300MM (ac) Panel will be fabricated with CRCA sheet 2/1.6sqmm duly powder coated with RAL 7035 siemens grey paint free standing indoor floor mounting type compartmentalized dust & vermin proof including gland plates, MS channels, MS Partitions, self adhesive rubber gaskets, door hinges, lifting hooks, panels locks with open/ close sticker, rubber grommets, danger plates, insciption name plates and wires for door earthing with thimbles. (ad) Power & Control Wiring (ae) Power & Control wire including timble, ferrules, tie PVC/ MCB, channels and end plates etc. - 01 No 90 3 HP DOL Starter for Fume Hood - 01 No. a) MCB 20A TP 10 kA `C" Curve - 01 No. (b)12A TP AC 3 duty power contactor - 01 No. (c)Aux. Contact Block 1 No. + 1 NC - 01 No. (d)MCB 6 A SP 10kA `C" Curve - 01 No.(e)ON/OFF/TRIP indicating lamp - 03 Nos. (f)Start/ Stop push button - 02 Nos. (g)A/M Selector switch - 1 No.(h)O/L Rely 3.5 - 5A - 1 No. (i)Single Phase Preventer - 01 No. (j)Power & Control terminal block - 01 No. (k) MS Enclosure - W-500MM H-500mm D-300MM (l) Panel will be fabricated with CRCA sheet 2/1.6sqmm duly powder coated with RAL 7035 siemens grey paint free standing indoor floor mounting typecompartmentalized dust & vermin proof including gland plates, MS channels, MS Partitions, self adhesive rubber gaskets, door hinges, lifting hooks, panels locks with open/ close sticker, rubber grommets, danger plates, insciption name plates and wires for door earthing with thimbles. - 01 No. (m) Power & Control Wiring(n) Power & Control wire including timble, ferrules, tie PVC/ MCB, channels and end plates etc. - 01 No. 91 (o) Flame Proof Push Button ON/ OFF indicator, RPM indicator & PH Meter 92 (p) Flame Proof Light (600mm x 300mm) with gland, rotary switch & power plug 93 (q)Light 600 mm x 600 mm 94 (r)Light 300 mm x 300 mm 95 (23) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.4 x 1.5 sq. mm 96 4 x 2.5 sq. mm 97 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (Flame Proof) 16A Switch & Socket (Flame Proof) 98 32A Switch & Socket (Flame Proof) 99 RTD Sensor 100 Socket Box with SS Plate 101 INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Makes : Cerberus Pro by Seimen/ Ansul / Bosch / Notifier.1 Loop Panel. 102 Supply and Installation of smoke detector. 103 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 104 Supply and Installation of Heat Detectors 105 Supplying, installation, testing & commissioning of addressable fire control module complete as required.Makes : Cerberus Pro by Seimen/ Ansul / Bosch / Notifier. 106 Supply and Installation of MCP 107 Supply and Installation of hooters with flashers 108 CABLING & WIRING Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. Makes :lap/ Finolex/ RR Kabel 109 Supply and Installation of Fire Extinguishers ABC 6 Kgs. 110 Supply and Installation of Fire Extinguishers CO2 4.5 kg 111 Supply and Installation of Fire Extinguisher Foam Type 9 ltrs 112 Supply and Installation of Fire Extinguishers Modular type 5 Kg clean Agent Gas
|