Procurement Of Equipments Machinery Under Development Grant At Medical Unit, Main Campus Shalimar, Skuast-K. , 15 Kw High Frequency Fixed X-Ray Machine (300 Ma) , High Frequency X-Ray Machine Suitable For General Radiography X-Ray Generator: ? High Frequency X-Ray Generator Having Frequency Of 100 Khz Or More Should Be Provided. ? Power Output Of Generator Should Be Not More Than 15 Kw. ? Radiography Kv Range Should Be : 40 To 125 Kv With 1 Kv Step ? Ma Range (Rad): 50- 300 Ma Or More In 9 Stations Or More ? Ma Stations : 50,63,80,100,125,160 For Small Focus & 200 & 300 Large Focal ? Mas Range ( Rad) 1 To 300 Mas In 30 Steps Or More ? Exposure Time (Rad.) 3.3 Ms To 6 Sec. ? Machine Must Give 300 Ma At 50 Kv Of 0.1 Sec. ? Generator Should Offer 3 Point Technique & User Should Have Ma, Kv & Mas. Parameters Selection Range. , Control : A Very Compact Feather Touch Control Panel Having Following Function & Indications Should Be Provided. The Panel Can Be Supplied In Floor Mount With Spill Proof Design. Following Feature Should Be Available On The Control Panel: ? Machine On/Off Switch. ? 12 Cm Lcd Digital Display Of Kv, Ma & Mas. ? Kv, Ma & Mas Increase And Decrease Switches. ? Ready & X-Ray On Switch. ? Bucky Selection Switch. ? Tube Focal Spot Selection Is Automatic. Depending On Applied Ma. ? Collimator Lamp On /Off Switch At Control Panel & Collimator. ? Self-Diagnostic Programme With Indicators For :- Earth Fault Error, Filament Error, Inverter Error, Rotor Error ,Tube Head Thermal Overload. ? Anatomically Programming Radiography (I.E. Apr) Should Be Provided In Which Kv, Ma & Mas Are Automatically Selected Depending Upon The Physically Of The Patient And Part Of The Body To Be X-Rayed. ? Anatomical Programming Of Minimum 220 Programmes Should Be Provided. Apr Program For Baby, Small, Medium, Large & Extra Large Patient. X-Ray Tube : ( Make & Model Of Tube Should Be Mention) ? One No. Dual Focus Rotating Anode X-Ray Tube Thermally Protected. ? Small Focus Is 1.0 Mm & Large Focus Is 2.0 Mm ? Anode Heat Storage Capacity Of Tube Should Be 150 Khu ? One Pair Of 6 Meter H.V Cable. ? One No. Double Slot Manual Collimator With Auto Shut Off Facility Should Be Provided. , Hv Tank : ? A Very Compact H.V Tank Filled With High Dielectric Transformer Oil Should Be Provided. The H.V Tank Should Contain H.V Transformers Filament, Transformers, H.V Rectifies & H.V Cable Receptacles. Tube Stand : ? Floor To Ceiling Stand With Counter Balanced Tube Head (Rotatable ± 90 °) 180° Rotatable Mounted On Floor Ceiling Rails For Convenient Movement Should Be Provided. Table : ? Manual Multi Position Table Should Be Provided. ? Table Height Is 860 Mm, Table Width Is 830 Mm & Length 1970 Mm. ? Tilting Angle -15°, 0° , 30° , 60° & 90° ? The Table Should Consist Of Motorized Reciprocating Bucky With Imported Grid Of Size 17¼” X 18¾” & Of Ratio 8:1-85 Lines/Inch. ? The Bucky Should Cover The Entire Length Of The Table And Should Be Locked At Any Desired Position By An Electromagnetic Lock. ? The Table Should Be Made Of Low Radiation Absorption, Waterproof Material. ? Table Accessories Like Stainless Steel Cassettes Tray Should Be Provided. ? Bucky Should Accept Cassettes Up To 14”X 17” Power Requirement : The Unit Should Be Operable On 3 Phase, 440 Volts Ac, 50 Hz 15 Amps With Line –Resist Less Than 0.4 Ohms. Line Regulation ± 10%. , Approvals: 1. The Quoted Model Should Be Approved By Aerb & Bis. 2. Company Should Have Iso 9001:2015, Iso 13485:2016, En Iso 14971:2012 And Icmed 13485 Certificate. Also Have Md 9 License To Manufacture Medical Devices From Cdsco Of Quoted Model. 3. Quoted X-Ray Tube Should Be Registered With Quoted X-Ray Machine Model. 4. X-Ray Manufacturer Is Registered In Msme & Nsic. 5. Manufacturer Didn’T Have Blacklisted /Debar From Any State Govt/ Psu/Central Govt Institute In Past Ten Years. No Stay Order And Pending Debar Case Is Pending In Indian Penal Court. 6. Manufacturer Is Having 100 Nos. Installation Of X-Ray Machines In Govt. Sector In Last One Year. 7. X-Ray Manufacturer Is Having Testing & Calibration Lab With Nabl Approved And Compliance With Iso/Iec 17025:2017 Standard. , Flat Panel Detector 1. The Detector Should Be Both Wired And Wireless For Data Communication. 2. The Detector Should Be A Flat Panel Detector With Cesium Iodide Scintillator 3. The Size Of The Detector Should Be 35 Cm X 43Cm (14”X17”) Or More 4. Should Have Spatial Resolution Of 3 Lines Pair / Millimeter Or Better 5. Pixel Pitch Should Be 150 Micron Or Less 6. Detector Quantum Efficiency (Dqe) Should Be 70% Or More @ Zero Lines Pairs (Near Zero) & Mtf Minimum 80% At 1 Cyc 7. The Active-Matrix Size Should Be 2.3K X2.3K Or More 8. Should Have A Minimum Grey Scale Of 16 Bits/ Pixel 9. Detectors Should Be Supplied With Two External Batteries And The Supplied Charger Should Be Able To Charge Two Batteries At A Time. Detector With Inbuilt Battery Should Not Be Quoted. 10. The Detector Should Be Able To Work Without The Battery Also Under Wired Mode. 11. Detector Should Be Light Weight (< 3Kg) 12. Detector Should Have Software Which Corrects The Effect Of Scatter Radiation On Acquired Image By Processing, Without The Need Of Physical Grid. It Should Be Quoted As Optional. 13. Withstand Load: Point Load – 100 Kg Or More, Surface Load – 300 Kg Or More 14. Detector Should Be Ce Or Usfda Approved , Acquisition Workstation: 1. Should Have A High Resolution Tft/Lcd Monitor Of Minimum 17” Size Or More 2. The Console Or Acquisition Workstation Pc To Be Supplied Should Be Of Latest Generation With At Least 4Gb Ram. 3. Operating Console Should Have Facility For Patient Identity Entry, Viewing And Processing Images. , Dry Imager System 1. The System Must Have A Laser Printer Without Need Of Any Wet Chemistry. 2. It Must Be Dicom Compatible Allowing Multiple Modalities To Be Connected At A Time. 3. The System Must Be Able To Print At Least 70 Films/ Hr. Of The 14" X 17" Size. 4. The Imager Must Have Spatial Resolution Of 500 Dpi Minimum. 5. The System Must Have Contrast Resolution Of 12 Bits/ Pixel Or More. 6. The Imager Should Be Equipped With 2 Tray On Line. 7. Time Required For Startup Approx. 15 Minutes Under 25 O C Room Temperature Conditions. Approx. 10 Minutes Under 25O C Room Temperature Conditions In Power Saving Mode , Fully Digital, Whole Body Color Doppler Ultrasound Machinewith Touch Penal Facility , Should Be Top Of The Line And State Of The Art Fully Digital Portable Ultrasound Machine With Provision For Doppler Examinations • It Should Be Suitable For Abdominal, Obstetrics, Gynecological, Cardiac Vascular, Thoracic, Transcranial, • Musculoskeletal, Urological, Small Parts, For Adults Andpediatric Patient. • Multiple Preloaded As Well As User Configurable Application Presets Should Be Available. • The System Should Have Advanced Measurement, Manual And Automatic For All Applications. • The System Should An Integrated High Resolution Tft / Lcd Of Minimum 21” (Flicker Free Images) Or More. • System Should Have Multi Gesture Touch Panel Of > 13 Inches • The System Should Have Image Storage Space 500Gb Or More • The System Should Have Minimum 200000 Or More Digital Processing Channels And 256 Or More Grey Shades. • The System Should Have Scanning Depth To Be 30 Cm Or More. • The System To Have A Dynamic Range Of 250 Decibels Or More. • System Should Support Transducer Technologies Like Phased Array, Convex, Linear, Endocavity, Micro Convex And 4D Volume Etc. • All Transducers Should Be Lightweight Digital Phased Array Broadband Type Transducers. • System Should Have 3 Active Port And Should Have Electronic Switching Ability Between The Transducers Without The Need Of Manual Disconnection • ?Should Be Supplied With Threetransducers (One Each): 1. Convex Electronic Phased Array Transducer: 2-6 (+/-1) Mhz For Abdominal Imaging. 2. Linear Transducer: 6-15 (+/-2) Mhz For Vascular And Small Part Imaging. 3. Tv/Tr Probe 4 -10 Mhz For Ob/ Gyn, Transvaginal And Transrectal 4. Adult Cardiac Probe 1-4 Mhz For Cardiac Applications , • System Should Have Online Scan Assistant • System Should Have Dicom 3.) Connectivity • System Should Have Capability Of Real Time Automatic Doppler Calculations • Convex. Tv/Tr And Linear Transducers Shall Have Detachable Reusable Biopsy Guides For Different Gauge Needles • The System Should Have A Frame Rate Of At Least 1500 Frames Per Seconds (Fps) In B Mode And More Than 600 Fps In Color Mode. • System Should Have Line Density More Than 900 • System Should Have Li Rad Option Inbuilt In The System • System Should Have B- Flow • System Should Have Strain Elastography • System Should Have Lgc • System Should Be Upgradable To Auto Ef And Stress Echo • System Should Dynamic Tissue Optimization • System Should Be Upgradable To Real Time 3D/ 4D Imaging • Should Have Capability To Scan Large Organ ( Upto 60 Cm) In A Stretch • System Should Have Cross Beam Imaging For Better Organ Visualization • Should Have Tvi, Amm And Imt For Cardiac Scanning • System Should Onboard Tutor For Learning And Enhancing The Technical Skill For Patient Scanning ??Scan Coach. • The System Should Have An Ergonomic Full Alphanumeric Soft Keys Keyboard With Easy Access Scans Control And Trackball Or Touchpad. , • The Systems Should Have Cine Loop Review Facility Of Not Less Than 400 Sec/300000 Inages. • The System Should Have The Facility Of Digital Storage And Retrieval Of B/W And Colour Image Data. • System Should Have Ai Enabled Auto Labelling Feature For Ruq • Provision For Usb Port And Lan Transfer Of Data Should Also Be Present. • The System Shall Support The All Dicom Functionality, Storage, Print, And Work List, Also Ready To Connect Topacs. • The System Should Have More Than 500 User Defined Presets • Imaging Modes Of Real Time 2D, Colour, Pulsed Wave, Continuous Wave And Power (Energy) Doppler, Anatomical M-Mode Should Be Available. • The System Should Have Boot Up Time Not More Than 2 Min • The System Should Have Doppler Velocity Range From 0.1 Cm / Sec – 1000 Cm/ Sec • Controls For 2D Mode: Total Gain, Depth, Tcg, Dynamic Range, Acoustic Power Output. • Controls For Colour Doppler: Prf, Colour Gain, Position And Size Of Roi, Steering Of Roi, Colour Maps And Colour Invert. • Measurements For 2D Mode: Multiple Distances, Area And Volume. • Measurement For Doppler Modes: Stenosis Quantification In Area Percentage, Diameter, Psv, Edv, Means, Pi, Ri, Acceleration Time And Index. Automatic And Manual Measurements And Display Of Pulsed Doppler Calculations Should Be Possible. • ?Unit Should Function With 200-240 V, 50 Hz Ac, 5-Amp Power Outlet Power Requirement To Be Specified • System Should Have Both Triplex And Duplex Display And A Wide Range Of Probes, Increases System Versatility And Adaptability To Our Clinical Needs. • , System Should Be Upgradable To Enhanced Needle Tracking,Panoramic Imaging And 3D Software In Future. • System Should Have Capability To Compare The Current Exam To The Previous Exam • System Should Have Continuous Optimization The Images When Scanning Different Tissues • System Should Have Onboard Contextual Reference Tool • System Should Have Lateral Gain Compensator • System Should Have Probe Check And E-Delivery Features • The Unit Should Beunited States Food And Drug Administration (Usfda) Approved. • System Should Have Capability Of Probe Check Built In The Machine • System Should Have Capability For Voice Comment Recording During Scanning • System Should Be Able To Connect With End Firing Linear Probe With Frequency 5- 10 Mhz • Additional Items Required 1. 3Kva Online Ups With 3Hr Backup 2. Color Printer 3. Thermal Printer 4. Isolation Transformer 5. Automatic Servo Stabilizer ? The Whole System Supplied Should Carry 3 Years Warranty. ? No Deviation On Specifications Will Be Acceptable. ? Compliance Sheet To Be Attached To The Tender Without Any Deviation. ? Configuration List To Be Attached Properly Mentioning Make And Model Of The Equipment. ? Brochures And All Required Certificates To Be Attached In The Tender. ? Proven Service Center In The Valley From More Than 5 Years. , 1. Note:- The Rates Quoted By The Bidder/S Shall Be Final And Inclusive Of Taxes, Carriages Of All Materials (Mechanical/Manual) And All Extra Charges Till The Installation, Testing Of Equipment/S Is Complete In All Respects.
|