Uric Acid - Reagent For Clinical Diagnosis, Final And Direct, Finally And Direct Colorimetric Method. Complete Set For Automation For Determining Uric Acid In Serum Or Plasma, Reagent Ready For Use. Presentation: Kit With Volume Not Less Than 250 Ml To Perform At Least 250 Tests. Accompanied By Standard, Calibrators And Other Inputs Necessary For Its Operation. The Reagent Set Should Be From The Same Manufacturer As The Multicolibrator And Biochemistry Controls. Note: The Reagent Must Necessarily Be Compatible With Bs 380 Mindray Equipment, Will Not Be Replaced Reagent That Is Not Compatible With This Equipment. Albumin - Reagent For Clinical Diagnosis, Final Spot Color Method, Complete Set For Quantitative Albumin Analysis Type And Other Human Liquids, Reagent Ready For Use. Accompanied By Standard, Alt/Gpt - Reagent For Clinical Diagnosis, Final Point Color Kinetic Method, Complete Automotive Set Of Quantitative Analysis Of Alt/Tgp, Reacted Reagent For Use. Presentation: Volume With Not Less Than 120 Ml To Perform At Least 120 Tests. Accompanied By Standard, Amylase - Reagent For Clinical Diagnosis, Determination In Serum, Plasma, Urine And Human Liquids, Type Of Quantitative Amylase Analysis, Ast/Got - Reagent For Clinical Diagnosis, Type Of Quantitative Ast/Top Analysis, Calibrators And Other Inputs Necessary For Its Operation. The Reagent Set Should Be From The Same Manufacturer As The Multicolibrator And Biochemistry Controls.Obs: The Reagent Must Necessarily Be Compatible With Bs 380 Mindray Equipment, 03/20/2025, Bilirubin - Clinical Diagnostic Reagent, Type For Automation, Type Of Analysis: Quantitative Direct And Total Bilirubin, Method: Final Point Color, With Additional Characteristics: With Additional Characteristics: With Diluent, Standard, Calibrators And Other Inputs Needed For Its Operation. The Reagent Set Should Be From The Same Manufacturer As The Multicolibrator And Biochemistry Controls. Reagent Ready For Use. Presentation: Kit With Volume Not Less Than 100 Ml To Perform At Least 100 Tests. Note: The Reagent Must Necessarily Be Compatible With Bs 380 Mindray Equipment, Will Not Be Replaced Reagents That Are Not Compatible With This Equipment. Test Corresponds To Kit., Calcium - Reagent For Clinical Diagnosis, Type Of Analysis: Calcium Quantitative, Method: Final Point Colorimetric. Presentation: Kit With Volume Not Less Than 200 Ml To Perform At Least 200 Tests. Accompanied By Standard, Calibrator - Reagent For Clinical Diagnosis, Type: For Biochemistry Automation, Analysis Type: Multiparametric Calibrator, Presentation: Lyophilized, Additional Feature: Minimum Of 25 Analytics. Note: The Reagent Must Necessarily Be Compatible With Bs 380 Mindray Equipment, Will Not Be Accepted In A Substitute Reagent That Is Not Compatible With This Equipment. After Reconstitution Should Have 5 Ml., Ck Mb - Reagent For Clinical Diagnosis, Type Of Quantitative Analysis Of Ck -M, Final Point Color Kinetic Method. Presentation: Kit With Volume Not Less Than 100 Ml To Perform At Least 100 Tests. Accompanied By Standard, Ck Nac - Reagent For Clinical Diagnosis, Type Of Analysis: Quantitative Ck -Nac
|