Lot 1 - Disciplinator - Gradile In Modulated Tubular Metal Structure Every 2, 00M, Measuring 100M Block, 1, 30M High, With Support Bases, Painted In Silver Gray. Front By 8, 00M Deep And 2, 20M Average Height From Floor To Floor And 6, 00M Right Foot; - Panel At The Bottom And On The Sides Of The Night & Day Canvas In Black; - Front And Side Closure In Plywood Painted With Latex Pva Ink In The Color To Be Indicated Later; - A 1, 40M Wide Access Ladder; - House Mix In Grid Q30, Measuring 3.00M By 3.00 With A 0, 50M High Floor, Covered With Night & Day Flexible Pvc Laminate Or Similar Translucent And Closing On The Sides With Night & Day Flexible Pvc Laminate Or Similar, Isolation Throughout The Perimeter With Modulated Fences Measuring 4.00M Per 4, 00M - Performed In A 12Mm Thick Tubular Tubular Structure Measuring 36, 00M Long By 2, 50M High Or Similar Painted On Both Sides With Pva Latex Paint In Gray. - Stage Floor And Practicable In Plywood With 12 Mm Thick And Covered With 4Mm Graphite Gray Carpet. - Aluminum Trelibox Testing Measuring 11, 00M By 1, 50M; - Grounding According To Abnt Technical Standards, Lot 2 - Type Iii Stage - Aluminum Trelibox Metal Structure Stage, Covered With Night & Day Flexible Pvc Laminate Or Similar In White Measuring 9, 00M From 6, 20M Of Average Floor To Floor And 4, 40M Wide; - House Mix Measuring 3.00 - Production Area Measuring 9, 00M Long By 10.00M Wide With Metal Structure And 2 -Plywood Closure, Painted With Latex Pva Paint In The Color To Be Indicated Later; - Tapume Executed In Tubular Structure With Plywood Closing With 12Mm Thick Measuring 24, 50M High Or Similar Painted On Both Sides With Pva Latex Paint In Gray; - Stage Floor And Practicable In Plywood With 12 Mm Thick And Covered With Graphite Gray Carpet With 4 Mm. - Aluminum Trelibox Testing Measuring 8, 50M By 1.00M; Grounding According To Abnt Technical Standards, Lot 2 - Type Iv Stage - Stage In Aluminum Trelibox Metal Structure, Covered With Night & Day Flexible Pvc Laminate Or Similar In White Measuring 6, 00M Deep And 1, 10M Medium To Floor To Floor And 4, 00M - Stage Floor And Practicable With 12 Mm Thick And Spoiled With Graphite Gray Carpet With 4 Mm. - Aluminum Trelibox Testing Measuring 5, 30M X 1.00M; - Grounding According To Abnt Technical Standards, Lot 3 - 500M² Aluminum Trelibox Structure, Right Foot Of 4.00 To 5.00M High, Side Columns Every 10.00M; Fixed To The Ground By Metal Shoes Or Fixation Rods. - Vinyl Canvas Coverage With White Blackout; Fixed To The Structure With A Duly Tensioned Fitting System. Grounding According To The Technical Standards Of Abnt., 19/03/2025
|