Cardiac Stents And Consumables, On Consignment Basis , Group –A1 Consumables & Accessories, Etc , Puncture Needle For Vascular Access • 18G • 6-7.5 Cm Long • 0.038 Inch Guide Wire Compatible • Should Be Supplied Individually Packed • Needle Should Have Protected Plastic Tube Covering , Puncture Needle Dedicated For Radial Artery Access • 20-22G • 3-5 Cm Long • 0.021 Or 0.025 Inch Guide Wire Compatible • Should Be Supplied Individually Packed • Needle Should Have Protected Plastic Tube Covering , Doppler Puncture Needle (With Facility Of Detecting Doppler Signals Of Vascular Structures) , Special Puncture Needle With Facility Of Detecting Ultrasound Images Of Vascular Structures) , Introducer Sheath For Adults (Size 4Fr.-9Fr.) (Standard Length) • Sizes 4French/5 French /6 French /7 French /8 French /9 French. • 10-11 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Introducer Sheath With Puncture Needle For Adults (Size 4Fr.-9Fr.) (Standard Length) • Sizes 4French/5 French /6 French /7 French /8 French /9 French. • 10-11 Cm Long • Pack Must Include 18 G, 6-7.5 Cm Long Puncture Needle • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Introducer Sheath For Adults (Size 10Fr.-11Fr.) (Standard Length) • 10Fr.& 11 Fr. • 10-11 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Introducer Sheath For Adults (Size 12Fr. And Higher) (Standard Length) • 12Fr/13 Fr./14 Fr. And Higher • 10-11 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 5Fr.-9Fr.) • Sizes 5 French /6 French /7 French /8 French /9 French. • Sheath Should Be Between 20-30 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Long Introducer Sheath (20-30 Cm Long) (Size 10Fr.-11Fr.) • 10 French & 11 French • Sheath Should Be Between 20-30 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Patient Transfer And Or Table Super Absorbent Sheet Having Loading Capacity Upto 150 Kg Size 210X80cm • Composite Of Air Formed Nonwoven And Cross-Linked Acrylate Copolymer. • Hotmelt Adhesive Based Hydrocarbons, Styrene, Rubber Copolymer And Resin. • Loading Capacity Of 150Kg • Dimension Of 210Cm X 80Cm Absorption Capacity Of 1.5 Ltr , Extra Thin Floor Cover Made With Clean, Extremely Absorbent Cellulose-Based Material Having Thermo-Mechanic Fibre Connectors Without Adhesive And Binding Agents For Freely And Swiftly Absorption Of Fluid, Non-Slip Backside, Retains 1.5 To 1.7 Ltr Of Fluids • Supercore Having Cellulose And Sodiumpolycarylate Bonded With Thermo-Mechanic Fibre Connectors Without Any Adhesive And Binding Agents • Pp-Nonwoven Hydrophiliated Surface And Rear Side • Quick Absorption Facility With Long-Term Binding Of Large Quantities Of Liquid Upto 1.7 Ltr • Extra Thin And Individual Cuttable • Easy In Use On Floors, Tables And Beds In Operating Theatres During Medical Examinations • Facility To Absorb Fluids From Both Sides • Non-Slip Proof Backside Having Size Of 116Cm X 76Cm , Breathable Fluid And Germ Impermeable, Skin Friendly Having Smooth Surface Transfer And Repositioning Sheet Retains Upto 1.9 Ltr Of Fluids And Upto 100Kg Weight Capacity • Odourless, Insoluble Fluid And Germ Impermeable Skin Friendly • Supercore® Technolgoy Composite Of 76% Cellulose And 24% Sodiumpolyacrrylate For Impressive Absorbency And Excellent Fluid Dispersion Than Conventional Airlaids • Having Weight Of Ca. 295G • Having Loading Capacity Upto 100Kg With Dimension Of 80 X 210Cm Having Absorption Capacity Of 2900 Ml/Pc Or 1800Ml/M2 , Radiation Protection Body Contoured Endoskeleton With 0.5Mm Lead Equivalence. Bilayer For Protection, With Mantis Arms, Proprietary Illiac Crest Belt For Efficient Weight Redistribution Ensuring No Weight On The Shoulders And Spine • Bilayer With Mantis Arms, Iliac Crest Belt For Efficient Weight Redistribution To Ensure No Weight On Shoulder And Spine • Made With Highest Quality Core Material Product In Lead And Non-Lead Materials • Having Durable And Flexible Endoskeleton • Having Comfort And Adjustable Belt With Memory Foam Interior And Spacer Mesh To Help Regulate Users Temperature • Available In 0.5Mm Lead Equivalence Available In Small, Medium, Large And X-Large Stocked , Group –A2 , Long Introducer Sheath (20-30 Cm Long) (Size 12Fr. And Higher) • 12Fr./13 Fr./14 Fr. And Higher • Sheath Should Be Between 20-30 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Long Introducer Sheath (30-50 Cm Long) (Size 5Fr.-9Fr.) • Sizes 5 French /6 French /7 French /8 French /9 French. • Between 30-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Long Introducer Sheath (30-50 Cm Long) (Size 10 Fr.-11Fr.) • Sizes Of 10 French & 11 French • Between 30-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Long Introducer Sheath (30-50 Cm Long) (Size 12 Fr. And Higher) • Sizes Of 12 French/13 French/ 14 French And Higher • Between 30-50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Extra Long Introducer Sheath (> 50 Cm) (Size 5Fr.-9Fr.) • 5 French /6 French /7 French /8 French /9 French. • More Than 50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible With Haemostatic Valve To Prevent Back Leak And Airaspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Extra Long Introducer Sheath (> 50 Cm) (Size 10 Fr.-11Fr.) • Sizes Of 10Fr.& 11 Fr. • More Than 50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Extra Long Introducer Sheath (> 50 Cm) (Size 12Fr.And Higher) • Sizes Of 12Fr./13 Fr./14 Fr. And Higher • More Than 50 Cm Long • 0.035 Or 0.038 Inch Guide Wire Compatible With Haemostatic Valve To Prevent Back Leak And Airaspiration • Integral Side Port With Attached 3-Way Stopcock • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • With Smooth And Resistance Free Insertion , Introducer Sheath Dedicated For Trans Radial Access • Sizes From 4French/5French/ 6 French/7 French • Between 7-11 Cm Long • 0.021 Or 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • With Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • Should Have Smooth And Resistance Free Insertion , Long Introducer Sheath Dedicated For Transradial Access • Sizes From 4French/5French/ 6 French/7 French • Between 16-24 Cm Long • 0.021 Or 0.025 Inch Guide Wire Compatible • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • With Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • Should Have Smooth And Resistance Free Insertion , Transradial Introducer Kit • Includes 21 G Puncture Needle • 0.021 Inch Introducer Guide Wire • Introducer Sheath Sizes From 4French/5French/ 6 French/7 French • Sheath Size Between 10-24 Cm Long , Group - A3 , Ptfe Coated Diagnostic Guide Wire - (Regular Length, Regular Stiffness) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Between 145-180 Cm Long • Should Be Available As Straight & J-Shaped Tip • Should Be Available In Variable Lengths Of Flexible/Floppy End • Should Be Available In Variable J Tip Sizes • Should Be Available In Fixed As Well As Movable Core , Ptfe Coated Diagnostic Guide Wire - (Exchange Length, Regular Stiffness) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be 240-300 Cm Long • Should Be Available As Straight Or J-Shaped Tip • Should Be Available In Fixed As Well As Movable Core , Ptfe Coated Diagnostic 0.032 Inch Guide Wire - (Regular Length, Extrastiff Shaft Strength) -Amplatz Type • Should Be Available In 0.032 Inches Size • Should Be Between 145-180 Cm Long • Should Be Available As Straight & J-Shaped Tip , Ptfe Coated Diagnostic 0.032 Inch Guide Wire - (Regular Length, Extrastiff Shaft Strength) -Amplatz Type • Should Be Available In 0.032 Inches Size • Should Be Between 240-300 Cm Long • Should Be Available As Straight & J-Shaped Tip , Ptfe Coated Diagnostic Guide Wire - (Regular Length, Extrastiff Shaft Strength) -Amplatz Type • Should Be Available In 0.035 Inches Size And Higher • Should Be Between 145-180 Cm Long • Should Be Available As Straight & J-Shaped Tip , Ptfe Coated Diagnostic Guide Wire - Exchange Length, Extrastiff Shaft Strength) -Amplatz Type • Should Be Available In 0.035 Inches Size And Higher • Should Be Between 240-300 Cm Long • Should Be Available As Straight & J-Shaped Tip , Ptfe Coated Diagnostic Guide Wire - Regular Length,Ultra Stiff Shaft Strength) -Amplatz Super Stiff Type • Should Be Available In 0.032, 0.35, 0.038 Inches Size • Should Be Between 145-180 Cm Long • Should Be Available As Straight Or J-Shaped Tip; Should Have Extra Ordinary Or Exceptional Shaft Strength , Ptfe Coated Diagnostic Guide Wire - Exchange Length,Ultra Stiff Shaft Strength) -Amplatz Super Stiff Type • Should Be Available In 0.032, 0.035 And 0.038 Inches Size • Should Be Between 240-300 Cm Long • Should Have Extra Ordinary Or Exceptional Shaft Strength , Pigtail Catheter • 4French/5French/6French/7French/8French Size • Should Be Available In Various Lengths , Angled Pigtail Catheter • 4French/5French/6French/7French/8French Size • Should Be Available In Various Lengths , Group-A4 , Pigtail Catheter With Marker • 4French/5French/6French/7French/8French Size • Should Be Available In Various Lengths , Judkins Catheter • 4French/5French/6French/7French/8French Size Left And Right Judkins Catheters In Various Standard Curves And Lengths. , Multipurpose Catheter • 4French/5French/6French/7French/8French Size Multipurpose Catheter In Various Standard Curves And Lengths. , Amplatz Catheter- 4French/5French/6French/7French/8French Amplatz Left (Al) And Amplatz Right (Ar) Catheter In Various Standard Curves And Lengths , Internal Mammary Catheter – • 4French/5French/6French/7French/8French In Various Standard Curves And Lengths , By- Pass Graft Catheters- • 4French/5French/6French/7French/8French In Various Standard Curves And Lengths. , Transradial Diagnostic Coronary Catheters - • 4French/5French/6French/7French Diagnostic Coronary Catheters Of Various Curves And Lengths Dedicated For Trans Radial Coronary Angiography , Nih Catheter- • 4French/5French/6French/7French/8French In Various Standard Curves And Lengths. , Cournard Catheter- • 4French/5French/6French/7French/8French In Various Standard Curves And Lengths. , Thermo Dilution Catheter • Should Be Compatible With The Available System , Group –B1 , Ptca Inflation Device • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Luminescent Analog Pressure Gauge (Up To 30 Atm) • Ergomatric And User Friendly Hand Held Design , Tuohy Borst (Haemostatic Y-Connector) For Ptca- Rotating Mechanism • Should Accommodate Virtually All Interventional Devices • Large Thumb Wheel For Easy Maneuverability • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End , Tuohy Borst (Haemostatic Y-Connector) For Ptca- Push Mechanism • Should Accommodate Virtually All Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End • Should Have Bleed Back Safety Mechanism • Stepwise Control For Open, Semi-Open And Closed Position , Tuohy Borst- Double (Haemostatic Y-Connector) For Bifurcation Ptca • Two Ports For Insertion Of Interventional Devices • Luer Connector At The Guiding Catheter End • Rotating Adapter At The Guiding Catheter End , Large Bore Tuohy Borst (Haemostatic Y-Connector) , Ptca Guide Wire Torquer • Should Hold Guide Wires From 0.009-0.018 Inches • Ergomatric And User Friendly Design , Ptca Guide Wire Insertion Needle • 20 G Size • 10 -12 Cm Long • Should Hold Up To 0.018 Inch Guide Wire , Ptca Guide Wire Accessory Kit Containing • Haemostatic Y Connector • Ptca Guide Wire Torquer • Ptca Guide Wire Insertion Needle , Ptca Inflation Device With Accessory Kit Containing • Ptca Inflation Device • Haemostatic Y Connector • Ptca Guide Wire Torquer • Ptca Guide Wire Insertion Needle , Control Syringes For Ptca • Clear, Glass-Like Plastic Syringe • Markings Up To 10 Or 12 Ml • Palm And Finger Assisted Easy Maneuverability • Plunger Should Have Resistance Free Movement • Should Have A Stopper With 0.5 Ml Reserve , Group -B2 , Connector Tubing (Connecting Between Touhy Borst And Manifold) • Should Be Between 20- 50 Cm • Should Have Large I.D For Easy Flow Of Contrast • Should Take High Pressure • Should Be Flexible • Should Have Male And Female Hubs , Manifold For Ptca With Two Side Ports • Large I.D For Easy Flow Of Contrast • Smooth Resistance Free Unidirection Handle/Knob , Manifold For Ptca With Three Side Ports • Large I.D For Easy Flow Of Contrast • Smooth Resistance Free Unidirection Handle/Knob , Manifold With Attached Tubings • Two Side Port Manifold • One Connector Tubing For Connecting Manifold To Tuohyborst • One Luer Lock Control Syringe (10 Or 12 Ml) For Contrast Injection • One Large Bore Tubing (With Flow Regulating Knob) For Withdrawing Contrast • One Three Way Stop-Cock , Ptca Kit: Should Contain The Following Items • One Tuohyborst (Haemostatic Y- Connector) • One Two Side-Port Manifold • One Connector Tubing For Connecting Manifold To Tuohyborst • One Luer Lock Control Syringe Having Markings Up To 10 Or 12 Ml For Contrast Injection • One Ptca Guide Wire Insertion Needle • One Ptca Guide Wire Torquer • One Large Bore Contrast Tubing (With Flow Regulating Knob) For Attachment Between Contrast Bottleand Manifold Side Port • One Pressure Monitoring Line (150 Cm) • One Three Way Stop-Cock , Femoral Compression Devices- Disc/Dome Based Compression , Domes Of Femoral Compression Device , Ptca Guiding Catheter- • Sizes Of 5Fr, 6Fr, 7Fr And 8Fr. • All Possible Shapes Including Catheters: Judkins/Femoral Left And Right, Extra Back Up Support,Amplatz, Voda, Multipurpose, Hockey Stick, Transradial Interventions, Bypass-Graft/Limainterventions And Others • Should Also Have Availability Of Smaller Length Catheters (90 Cm) • Should Also Have Availability Of Catheters With Side Holes • Should Also Have Short Tip Catheter , Large Lumen (I.D) Ptca Guiding Cathete (6 French Size) • Must Have I.D Of More Than 0.070 Inch • Should Have All Possible Shapes Including Catheters: Judkins/Femoral Left And Right, Extra Back Upsupport, Amplatz, Voda, Multipurpose, Hockey Stick, Transradial Interventions, Bypassgraft/Lima Interventions, Short Tip Catheters And Others , Large Lumen (I.D) Ptca Guiding Cathete (7 French Size) - • Must Have I.D Of More Than 0.080 Inch • Should Have All Possible Shapes Including Catheters: Judkins/Femoral Left And Right, Extra Back Upsupport, Amplatz, Voda, Multipurpose, Hockey Stick, Transradial Interventions, Bypassgraft/Lima Interventions, Short Tip Catheters And Others , Guide Extension Catheter With The Working Length Of 150 Cm And Guide Extension Segment Upto 40Cm With 1X1 Stainless Steel Wire Braiding With Hydrophilic Coating And Compatible With 6F/7F And 8F Femoral Guide Catheter , Group -B3 , Ptca Guiding Catheter For Dca , Ptca Guide Wire -Regular Length, Regular Shaft Support And Floppy Tip , Ptca Guide Wire -Regular Length, Extra- Support Shaft And Floppy Tip , Ptca Guide Wire - Exchange Length , Ptca Guide Wire- Hydrophilic Coated, Regular Length , Ptca Guide Wire- Hydrophilic Coated, Exchange Length , Special Ptca Guide Wires With Elastinite Core And Stainless Steel , Shaft Support • Both Regular And Exchange Length Wires • Should Have Wires With Varying Degree Of Shaft Support , Special Ptca Guide Wire With Dual Coating • Should Have Distal Hydrophilic Coating And Proximal Hydrophobic Coating • Should Have Wires With Variable Tip Stiffness And Variable Shaft Support , Special Ptca Guide Wire With Multiple Markers For Measuring The Length Of Stenotic Segment , Ptca Guide Wires For Chronic Total Occlusion (Cto) , Group -B4 , Special Non-Tapering Ptca Guide Wires For Cto With Platinum Iridiumdistal Spring Coil • Wires Available In Variable Distal Tip Stiffness, Measured In Terms Of Grams , Special Tapering Ptca Guide Wires For Cto With Platinum Iridiumdistal Spring Coil • Wires Available In Variable Distal Tip Stiffness, Measured In Terms Of Grams , Special Tapering Ptca Guide Wires For Cto Withhydrocoathydrophiliccoating • Wires Available In Variable Distal Tip Stiffness , • Special Hydrophilic Ptca Guide Wires For Cto With Super Elasticalloy (Ni-Ti) Core Polyurethrane Hydrophilic Distal Coating , Special Ptca Guide Wires For Cto, Dedicated For Retrogradeapproach , Extension (Doc) Wire For Approved Regular Length Ptca Guide Wires , Penetration Catheters For Cto Having Rotational Bluntpenetration , Penetration Devices For Cto By Blunt Dissection Using Acuating Jaws , Ptca Guide Wire With Bidirectional Deflectable Distal Tip , Ptca Catheter With Deflectable Distal End • Should Guide The Direction Of Ptca Guide Wire , Cto Reentry System With 2 Over The Wire Lumens And 2 Hubs, 3 Exit Ports For 360 Degree Functionality For Sgr Technique 18G • Over The Wire Dual Wire Lumen Micro Catheter • 1.5F Lesion Entry Profile* • Two Separate Otw Lumens And Three Exit Ports 360 Degree Guidewire Redirection Option , Dual Lumen Device For Simultaneous Haematoma Aspiration And Redirection Of Guidewire In True Lumen In Complex Cto Cases, 360 Degree Access • 2.3Fx3.3F Distal Shaft Profile And 2.6Fx3.4F Proximal Shaft Profile • 0.014” Guidewire Compatibility • Usable Length Of 140Cm Additional Exit Port In The Tip Lumen Of The Exit Port Of The Stylet Lumen , Trapping Device For Wire Trapping Used With Otw Devices With Lowest Shaft Profile Of 2F • Single Use Device Consisting Of Hub, Shaft And Balloon • Highly Compatible Small Shaft Profile Of 2F • Designed To Trap The Guidewire At Low Inflation Pressure Depth Marker For 90Cm Guide Catheter , Intra Coronary Guide Extension Catehter • Flex Zone And Unique 3 Zone Transition For Smooth Trackability • Highest Coiling Density For Extra Pushability • 25Cm Rapid Exchange Section • Two Exit Markers At 95Cm And 105Cm Working Length Of 150Cm , Group -B5 , Ptca Balloon (Non-Compliant) - • Quote Both Monorail (Rapid Exchange) And Otw Balloons • Available In All Sizes From 2- 4.0 Mm, Variable Lengths • Should Have A Very High Rated Burst Pressure , Special Large Ptca Balloons Of More Than 4 Mm • Variable Lengths , Special Ptca Balloon Catheter With Low Crossing Profile • Must Have Crossing Balloon Profile Of Less Than 0.025 Inches , Special Ptca Balloon Catheter Of Less Than 1.5 Mm • Should Be Available In Variable Balloon Lengths , Special Otw Ptca Balloon For Septal Ablation For Hocm , High Pressure Cto Non Compliant With Low Crossing Profile (Diameter 0.85Mm) Assorted Sizes) • Xr (Excellent Rewrap) Balloon Material With Ultrathin Marker Bands • Hydro-X Hydrophilic Coating (Distal Tip To Exit Port) • Invio Coating On Guidewire Lumen • Sub-Zero Flex Tip Tapered Tip With Zero Guidewire Transition For Smooth Lesion • 0.85Mm Diameter • P-Tech Hypotube With Excellent Transitional Balance, Pushability And Exceptional Kink Resistance • Crossing Profile Of 0.0313 Inches And Tip Entry Profile 0.0208 Inches Available In Sizes 1.5 – 5.00 Mm Diameter With Length Of 10,12,15, 20 & 30Mm , Group -B6 , Ptca Balloon For Retrograde Approach Of Cto • Should Be Available In Both Regular And Long Lengths For Retrograde Approach , Non Compliant Speciality Balloon Having The Catheter Length Of 140 Cm Or More. Tip Entry Profile Of 0.019 Inch Or Less And Mid- Balloon Profile Of 0.036 Inch Or Less With 3/4 Stainless Steel Cutting Blades Having A Functional Height Of 0.005 Inch. Available In A Working Length Of 6, 10 & 15Mm And Balloon Having A Working Range Between 6 To 12 Atm. , Scoring Balloon Catheter For Ptca , Dual Wire Ptca Dilatation Catheter , Drug Eluting Ptca Balloon Using Matrix Technology , Ptca Bifurcation Balloon , Stainless Steel Coronary Stents, Premounted On Balloon – , Stainless Steel Coronary Stents, Premounted On Balloon – , Stainless Steel Coronary Stents, Premounted On Balloon – , Cobalt Chromium Balloon Coronary Stents, Premounted Onballoon – , Group -B6- A , Coronary Stents : Non-Medicated Coronary Stent Balloonmounted , Non-Medicated Stent On Stainless Steel Platform Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Uniform Ultrathin Struts ( Up To 60 Microns) Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61 To 80 Microns) Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Struts Thickness ( > 80 Microns) Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform For Coronary Artery Diameters All Sizes Including 4.5Mm Or More. Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform For Coronary Artery Disease All Lengths Including 8Mm Or Less. , Group -B6- B -Coronary Stents : Non-Medicated Coronary Stent , Balloonmounted , Non-Medicated Stent On Stainless Steel Platform , Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Uniform Ultrathin Struts ( Up To 60 Microns) , Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61 To 80 Microns , Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform With Struts Thickness ( > 80 Microns) , Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform For Coronary Artery Diameters All Sizes Including 4.5Mm Or More. , Balloonmounted , Non-Medicated Stent On Non-Stainless Steel Platform For Coronary Artery Disease All Lengths Including 8Mm Or Less. , Group -B6- B.Coronary Stents : Medicated Coronary Stent -Sirolimus Eluting , Balloon Mounted, Sirolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodurable Polymer On A Non-Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Cocr Platform With Hybrid Stent Design And Uniform Thin Struts Upto 65 Micron, And Diameter From 2.25 To 4Mm Of Varying Lengths From 10 To 40 Mm. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Thin Struts (61-80 Microns) , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Thin Struts (61 -80 Microns) And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns) And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) Of Varying Lengths Including Stent Length Of 8Mm Or Less. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns)Of Varying Lengths Including Stent Length Of 8Mm Or Less , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length Of 8Mm Or Less , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns) Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted , Polymer Free, Sirolimus Eluting Stent , Group -B6- C - Coronary Stents : Medicated Coronary Stent -Drug Eluting , Balloon Mounted, Sirolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodurable Polymer On A Non-Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Stainless Steel Platform. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Cocr Platform With Hybrid Stent Design And Uniform Thin Struts Upto 65 Micron, And Diameter From 2.25 To 4Mm Of Varying Lengths From 10 To 40 Mm. , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Thin Struts (61-80 Microns) , Balloon Mounted, Sirolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Thin Struts (61 -80 Microns) And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.0Mm To 4.00 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns) And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.25Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) Of Varying Lengths Including Stent Length Of 8Mm Or Less. , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns)Of Varying Lengths Including Stent Length Of 8Mm Or Less , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length Of 8Mm Or Less , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (Upto 60 Microns) Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Ultrathin Struts (61-80 Microns) Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted, Sirolimus Eluting Stenton Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length Of 48Mm Or More , Balloon Mounted , Polymer Free, Sirolimus Eluting Stent , Group -B6- D Coronary Stents : Medicated Coronary Stent -Drug Eluting , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodurable Polymer On Stainless Steel Platform. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodurable Polymer On Non-Stainless Steel Platform. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodurable Polymer On Non-Stainless Steel Platform And Diameters Of 2.25Mm Or Less To 4.00Mm Or More Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodegradable Polymer On Non Stainless Steel Platform. , Balloon Mounted, Everolimus Eluting Stent With Biodegradable Polymer On Cocr Platform With Hybrid Stent Design And Uniform Ultrathin Struts ( Upto 63 Micron) And Diameters Of 2.25 To 4.00Mm. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Uniform Thin Struts (61-80 Microns) , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform With Struts Thickness Greater Than 80 Microns. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Ultra Thin Struts ( Upto 60 Microns) And Diameters Of 2.0Mm To 4.0Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61-80 Microns) And Diameters Of 2.0Mm To 4.0Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.0Mm To 4.0Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Ultra Thin Struts ( Upto 60 Microns) And Diameters Of 2.25 Mm To 4.5Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61-80 Microns) And Diameters Of 2.25 Mm To 4.5Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Diameters Of 2.25 Mm To 4.5Mm Of Varying Lengths. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Ultra Thin Struts ( Upto 60 Microns) Of Varying Lengths Including Stent Length 8Mm Or Less. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61-80 Microns) Of Varying Lengths Including Stent Length 8Mm Or Less. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length 8Mm Or Less. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Ultra Thin Struts ( Upto 60 Microns) Of Varying Lengths Including Stent Length 48Mm Or More. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Thin Struts ( 61-80 Microns) Of Varying Lengths Including Stent Length 48Mm Or More. , Balloon Mounted, Everolimus/Zotarolimus Eluting Stent On Non-Stainless Steel Platform With Uniform Strut Thickness Greater Than 80 Microns And Of Varying Lengths Including Stent Length 48Mm Or More. , Balloon Mounted , Polymer Free, Everolimus/Zotarolimus Eluting Stent , Usfda Approved Platinum Chromium Everolimus Eluting Des With Abluminally Coated Bioabsorbable Polymer Having A Thickness Not More Than 5?M And A Bi Segment Shaft With A Midshaft Segment Made Of Lasercut Hypotube With The Length >10Cm And Minimum Of About 500 Lasercuts. Should Be Available In Diameters From 2.25 To 5.00Mm And Lengths Of 8,12,16,20,24,28,32,38 And 48Mm And The Total Stent Thickness < 90?M. , Usfda Approved Platinum Chromium Everolimus Eluting Des Specifically Designed For Left Main And Large Proximal Vessels With Abluminally Coated Bioabsorbable Polymer Having A Thickness Not More Than 5?M And A Bi Segment Shaft With A Midshaft Segment Made Of Hypotube With Lasercuts And A 12 Peak Design. Should Be Available In Diameters From 3.50 To 5.00Mm And Lengths Of 8,12,16,20,24,28 And 32 Mm Withthe Overexpansion Capability Of Minimum 6.00 Mm. Total Stent Thickness Should Be < 95?M , Usfda Approved Platinum Chromium Everolimus Eluting Des With Permanent Polymer Having A Thickness Not More Than 5?M And A Bi Segment Shaft With A Midshaft Segment Made Of Lasercut Hypotube With The Length Of 10Cm And About 300 Lasercuts. Should Be Available In Diameters From 2.25 To 4.00Mm And Lengths Of 8,12,16,20,24,28,32 And 38 Mm. , Sirolimus Coated Drug Eluting Coronary Stent. Hybrid Cell Design, Cobalt-Chromium Platform With Biodegradable Polymer, Small Strut Thickness Of 50 ?M 5F Guide Catheter Compatible, With Variable Diameter And Length Available Upto =48Mm , Everolimus Coated Drug Eluting Coronary Stent. Hybrid Cell Design, Cobalt-Chromium Platform With Biodegradable Polymer, Small Strut Thickness Of 50 ?M 5F Guide Catheter Compatible, With Variable Diameter And Length Available Upto =48Mm , Sirolimus Coated Drug Eluting Tapered Coronary Stent With 0.5 Mm Difference Of Diameter Between Proximal And Distal End.Cobalt Chromium Platform With Biodegradable Polymer, Small Strut Thickness, Different Diameter Of Upto 4.5Mm (Proximal End ) And Length Available Upto = , Group -B6- E. Medicated Coronary Stent -Paclitaxel Eluting , Balloon Mounted, Paclitaxel Eluting Stent With Biodurable Polymer On Stainless Steel Platform. , Balloon Mounted, Paclitaxel Eluting Stent With Biodurable Polymer On Non-Stainless Steel Platform. , Balloon Mounted, Paclitaxel Eluting Stent With Biodegradable Polymer On Stainless Steel Platform. , Balloon Mounted, Paclitaxel Eluting Stent With Biodegradable Polymer On Non-Stainless Steel Platform. , Balloon Mounted, Paclitaxel Eluting Stent On Non-Stainless Steel Platform And Diameters Of 2.0Mm To 4.0Mm Of Varying Lengths. , Balloon Mounted, Paclitaxel Eluting Stent On Non-Stainless Steel Platform And Diameters Of 2.25 Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Paclitaxel Eluting Stent On Non-Stainless Steel Platform Of Varying Lengths Including Stent Length Of 8Mm Or Less. , Balloon Mounted, Paclitaxel Eluting Stent On Non-Stainless Steel Platform Of Varying Lengths Including Stent Length Of 48Mm Or More. , Group -B6- F Coronary Stents : Medicated Coronary Stent -Newer Limus Analogue ( Other Than Sirolimus, Everolimus, Zotarolimus) , Balloon Mounted, Newer Limus Analogue With Biodurable Polymer On Stainless Steel Platform. , Balloon Mounted, Newer Limus Analogue With With Biodurable Polymer On Non-Stainless Steel Platform. , Balloon Mounted, Newer Limus Analogue With With Biodegradable Polymer On Stainless Steel Platform. , Balloon Mounted, Newer Limus Analogue With With Biodegradable Polymer On Non-Stainless Steel Platform. , Balloon Mounted, Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform And Diameters Of 2.0Mm To 4.0Mm Of Varying Lengths. , Balloon Mounted, Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform And Diameters Of 2.25 Mm To 4.5 Mm Of Varying Lengths. , Balloon Mounted, Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform Of Varying Lengths Including Stent Length Of 8Mm Or Less. , Balloon Mounted, Newer Limus Analogue Eluting Stent On Non-Stainless Steel Platform Of Varying Lengths Including Stent Length Of 48Mm Or More. , Balloon Mounted ,Newer Limus Analogue With Abluminal Drug Coating. , Group -B6- G Other Coronary Stents , Self - Expanding Drug Eluting Coronary Stent Dedicated For Bifurcation Lesion. , Self - Expanding Drug Eluting Coronary Stent Dedicated For Side Branch Access. , Balloon Mounted Drug Eluting , Tapered Coronary Stents. , Balloon Mounted Coronary Stents Covered With Flexible Mesh Sleeve. , Self Expanding Drug Eluting Coronary Stents. , Balloon Mounted, Dual Drug Coated Drug Eluting Stents. , Bioresorbable Coronary Vascular Scaffold. , Coronary Stent Graft/Coronary Covered Stent With Sandwich Design Of Variable Diameters And Lengths. , Coronary Stent Graft/Coronary Covered Stent Of Variable Diameters And Lengths, With Single Stent Design And 5 French Guide Catheter Compatibility. , Biodurable Polymers Includesibs( Poly Styrene-B-Isobutylene -B Styrene), Pbma( Poly-N-Butyl Methacrylate,Peva ( Polyethelene Covinyl Acetate), Pvdf-Hfp(Poly Vinlidine Fluoride Hexafluropropylene,0 Pc( Phosphoryicholine) Siloxane Copolymer And Any Other Commercially Approved Biodurable Polymer. , Paclitaxel Coated Semi- Compliant Drug Coated Balloon Having A Drug Load Of Less Than 3 ?G/Mm2 And A Balanced Hydrophilic Hydrophobic Excipient With A Bi Segment Inner Lumen Shaft And A Hydrophilic Coating On The Shaft. Available In The Diameters Of 2.00 To 4.00 Mm And Lengths Of 12Mm, 15Mm, 20Mm & 30Mm. Working Range Of 6 To 14 Atm For Sizes Upto 3.0Mm & 6 To 12 Atm For 3.50 Mm & 4.00 Mm. , Biolimus Aa Drug Eluting Stent System • Hybrid Cobalt Chromium Stent • Abluminal Biodegradable Polymer With Biolimus A9 Eluting Stents • Mid-Section S-Shape Connectors • Thin Strut Cobalt Chromium • 1.37Mm Large Cell Opening For Easy Side Branch Access • Excellent Trackability And Pushability Together With Low Tip Entry Profile Available In Sizes Of 2.25, 2.50, 2.75, 3.00, 3.50 & 4.00Mm Dia With Stent Length Of 9, 14, 19, 24, 29, 33 & 36Mm , Polymer And Carrier Free Drug Coated Stent With Biolimus A9 (Ba9) & Microstructured Abluminal Surface, Having Lower Peak Force For Better Tracebility, Higher Pushability & Large Cell Opening Diameter • Polymer Free And Carrier Free Drug Coated Stent • Biolimus A9 (Ba9) And Micro Structured Abluminal Surface • Lower Peak Force For Better Traceability • Higher Pushability Of 49 Pft To Increase The Efficiency Of The Force • Large Cell Opening Diameter 1.702Mm To Provides Better Access To Side Branch For Subsequent Stents Available In Sizes Of 2.25, 2.50, 2.75, 3.00, 3.50 & 4.00Mm Dia With Stent Length Of 8, 11, 14, 18, 24, 28, 33 & 36Mm , Sirolimus Eluting Coronary Side Branch Stent System.Sizes Available 2.5Mm X 2.5Mm,3.0Mm X 2.5Mm,3.5Mm X 2.5Mm, 3.5Mm X 3.00Mm 4.0Mm X 3.5Mm Lengths 16Mm, 19Mm, 24Mm, & 29Mm , Group-B10 , Rotalink Plus (Advancer And Burr) , Rotational Atherectomy Guide Wires , Rotaglide Lubricant , Ivus Catheter • Should Be Compatible With Available Machine Of Make Boston Scientific , Catheter For Virtual Histology • Should Be Compatible With Available Machine , Catheter For Optical Coherence Refractometry • Should Be Compatible With Available Machine , Drug Delivery/Infusion Catheter , Coronary Probing Catheter , Coronary Perfusion Catheter , Coronary Trapeer Catheter , Group--B11 , Special Micro -Catheter For Cto Retrograde Approach , Thrombectomy Catheters With Manual Suction During Ptca , Thrombectomy Catheters With Distal Balloon Occlusion Andautomated Suction During Ptca , Thrombectomy Catheters With Motorized Cutting And Suction During Ptca , Doppler Wire For Ptca , Presssure Wire For Ptca , Group-B12 , Embolic Protection Devices Based On Filter Technology/Mechanism , Embolic Protection Devices With Distal Balloon Occlusive Technology , Embolic Protection Devices With Proximal Balloon Occlusive Technology , Arterial Puncture Closure Devices - Collagen Plug Based , Arterial Puncture Closure Devices - Suture Based , Disposable Femoral Compression Devices- Balloon Based Compression , Compression Devices For Radial Artery- Balloon Based Compression , Compression Devices For Radial Artery- Strap Based Compression , Ptca Guide Wire Re-Entry Catheter For Cto , Coronary Micro Catheter- , Group –C (Drugs Used In Cath Lab During Coronay Interventios) , Injection Nikorandil (2 Mg) , Injection Bivaluridin , Injection Tirofiban , Injection Eptifibatide , Injection Abciximab , Group– D1 , Puncture Needle For Vascular Access For Paediatric / Neonatal Use • 20-22G • 3-5 Cm Long • 0.021 Or 0.025 Inch Guide Wire Compatible • Should Be Supplied Individually Packed • Needle Should Have Protected Plastic Tube Covering , Intravenous Cannula ‘Medicut’ Type For Vascular Access • Available In 16, 18, 20, 22 G • Supplied With An Attached Luer-Lock 2 Ml Syringe • Individually Packed With Easy Peel Off , Intravenous Cannula For Vascular Access • Available In 16, 18, 20, 22 G • 20 G Should Allow The Passage Of 0.025 Hydrophilic Guide Wire • Individually Packed With Easy Peel Off , Intravenous Cannula For Vascular Access In Neonates • Available In 24, 26 G • Individually Packed With Easy Peel Off , Introducer Sheaths For Pediatric Use (Size 4-6Fr.) With Straight Introducer Wire • Sizes 4French/5French/6 French • Between 5.5-7.5 Cm Long • 0.021 Inch Straight Introducer Guide Wire • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • With Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • Should Have Smooth And Resistance Free Insertion , Introducer Sheaths For Pediatric Use (Size 4-6Fr.) With J Tip Introducer Wire • Sizes 4French/5French/6 French • Between 5.5-7.5 Cm Long • With 0.021 Inch Introducer Guide Wire With J Tip On One End And Straight Tip On The Other End (Bothends Should Be Soft) • With Haemostatic Valve To Prevent Back Leak And Air Aspiration • Should Have Integral Side Port With Attached 3-Way Stopcock • With Suture Eye For Securing Sheath • Kink Resistant • With A Dilator-Hub Lock Mechanism To Prevent Its Back-Out During Insertion • Should Have Smooth And Resistance Free Insertion , Introducer Sheath Of 3 French (Fr.) Size (For Neonatal/ Pediatric Use) , Pigtail Catheter (Pediatric) - • 4French/5French/6French Size • Smaller Length For Neonatal And Pediatric Use • Must Be Fda Approved , Judkins Catheter (Pediatric) - • 4F/5F/6F Size Left And Right Judkins Catheters In Various Standard Curves And Lengths. • Must Be Fda Approved , Special Judkins Coronary Catheter With 2.5 Cm Curve (Pediatric) • 4F/5F/6F , Group-D2 , Multiprpose Catheter (Pediatric) • 4F/5F/6F In Various Standard Curves And Lengths , 3- French’ Diagnostic Catheters For Neonatal Use • Pigtail, Judkins, Multipurpose, Cobra And Other Diagnostic Catheters Of 3 Fr. Size • Varying Lengths And Shapes , Special Swan Ganz Catheter With: • 4F Catheter Should Allow The Passage Of At Least 0.021 Inch, 5F – 0.025 Inch, 6F – 0.035 Inch And 7F,8F – 0.038 Inch Hydrophilic Guide Wire • Must Be Available In 4F, 5F, 6F And 7F And 8 Fr. Sizes • Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter • 10 Cm Marking Along Catheter Body To Confirm Insertion Depth , Balloon Tipped Angiography Catheter , Berman Cathter • Must Be Available In 4F, 5F, 6F And 7F Sizes • Should Have 6 - 8 Holes Proximal To The Balloon For Dye Injection • Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter • 10 Cm Marking Along Catheter Body To Confirm Insertion Depth , Reverse Berman Catheter • Should Be Available In 4F, 5F, 6F & 7F Sizes • Catheter Should Be Tapered At Tip To Ensure Uniform Diameter Of The Whole Catheter • Should Have Holes Proximal To The Balloon For Dye Injection • Should Have A Hole At The Proximal Tip To Allow The Passage Over The Wire , Mullins Sheath Without Side Arm • Should Be Available In 6 Fr./7 Fr./ 8Fr. Sizes • Thick And Stiff Dilator For Guiding Septal Puncture , Mullins Sheath With Side Arm • Should Be Available In 6 Fr./7 Fr./ 8Fr. Sizes , Group-D3 , Ptmc Balloon ‘Inoue Type’ With Accessories , Ptmc Balloon Of ‘Inoue Type’ Without Accessories , Ptmc Balloon ‘Inoue Type’ With Accessories , Ptmc Balloon Of ‘Inoue Type’ Without Accessories- , Ptmc Balloon ‘Inoue Type’ With Accessories – , Ptmc Balloon ‘Inoue Type’ Without Accessories – , Transseptal Puncture Needle • Infants, Pediatric And Adult Sizes • Tapering Tip • Standard Curve • Hub With Angle Indicator , Group-D4 , Asd Closure Devices With Delivery System - • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes (6 Mm – 40 Mm) , Asd Closure Device Without Delivery System , Delivery Sheath For Asd Closure Device- Compatible With The Device Approved In Item No. 27.01 , Preloaded Asd Closure Devices - • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Preloaded Device With Delivery Cable , Asd Closure Devices With Delivery System – • Device Made Of Biologically Inert Material • Available In All The Sizes , Asd Closure Device Without Delivery System , Delivery Sheath For Asd Closure Device- Compatible With The Device Approved In Item No At . 27.04 , Asd Closure Device With Delivery System – • Device Made Of Biologically Inert Material • Available In All The Sizes , Asd Closure Device Without Delivery System – , Delivery Sheath For Asd Closure Device– Compatible With The Device Approved In Item No. At 27.08 , Fenestrated Asd Closure Devices , Group-D5 , Vsd Closure Devices With Delivery System - • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes , Vsd Closure Devices Without Delivery System , Delivery Sheath For Vsd Closure Device - Compatible With The Device Approved In Item No.At 28.01 , Vsd Closure Devices With Delivery System - • Device Made Of Biologically Inert Material • Available In All The Sizes , Vsd Closure Devices Without Delivery System - , Delivery Sheath For Vsd Closure Device- Ce Marked Compatible With The Device Approved In Item No.At28.04 , Vsd Closure Device With Delivery System – • Device Made Of Biologically Inert Material • Available In All The Sizes , Vsd Closure Device Without Delivery System – Delivery Sheath For Vsd Closure Device– Compatible With The Device Approved In Item No. At 28.07 , Pda Closure Devices With Delivery System - • Approved For Pediatric/Adult Use • Device Made Of Biologically Inert Material • Self-Centering, Detachable Device With Delivery Cable • Available In All The Sizes , Group -D6 , Pda Closure Devices Without Delivery System , Delivery Sheath For Pda Closure Device - Compatible With The Device Approved In Item No.29.01 , Pda Closure Devices Without Delivery System - • Device Made Of Biologically Inert Material • Available In All The Sizes , Pda Closure Device Without Delivery System – , Delivery Sheath For Pda Closure Device – Compatible With The Device Approved In Item No.At 29.04 , Pda Closure Device With Delivery System – Device Made Of Biologically Inert Material • Available In All The Sizes , Pda Closure Device Without Delivery System – , Delivery Sheath For Pda Closure Device- Compatible With The Device Approved In Item No. At 29.07 , Group-D7 , Pfo Closure Device With Delivery System – Approved For Pediatric /Adult Usedevice Made Of Biologically Inert Material • Available In All The Sizes , Pfo Closure Devices Without Delivery System , Delivery Sheath For Pfo Closure Device – Compatible With The Device Approved In Item No. At 30.01 , Pfo Closure Devices With Delivery System - • Device Made Of Biologically Inert Material • Available In All The Sizes , Pfo Closure Devices Without Delivery System - , Delivery Sheath For Pfo Closure Device- Compatible With The Device Approved In Item No. At 30.04 , Pfo Closure Device With Delivery System – • Device Made Of Biologically Inert Material • Available In All The Sizes , Pfo Closure Device Without Delivery System , Delivery Sheath For Pfo Closure Device– Compatible With The Device Approved In Item No. At 30.07 , Sizing Balloon For Device Closure – Circular Shape , Sizing Balloon For Device Closure – Oval Shaped , Sizing Plate For Device Closure , Group-D8 , Delivery Cables For Asd/Vsd/Pda Devices , Retrievers For Asd/Vsd/Pda Devices , Sheath For Retrival Of Devices , Wire 0.018” Regular Length, Regular Shaft Stiffness • Floppy Tip • Straight / J Shaped Tip • 140-180 Cm Long , Wire 0.018” Regular Length, Extra- Stiff Shaft • Floppy Tip • Straight / J Shaped Tip • 140-180 Cm Long , Wire 0.018” Exchange Length, Regular Shaft Stiffness • Floppy Tip • Straight / J Shaped Tip • 240-300 Cm Long , Wire 0.018” Exchange Length, Extra- Stiff Shaft • Floppy Tip • Straight / J Shaped Tip • 240-300 Cm Long , Valvoplasty Balloon Catheters • Varying Sizes And Diameters • Approved For Pediatric/Adult Use , Special Balloon Catheter Compatible With 4 French Sheath • Compatible With 0.018 Inch Guide Wire • Varying Length And Diameter , Special Pediatric Valvoplasty Balloon Catheters Compatible With 4 French Sheath • Compatible With 0.025 Inch Guide Wire • Varying Length And Diameter , Group-D9 , Valvoplasty Balloon Catheters (Sizes 10 – 22 Mm) • Approved For Pediatric/Adult Use • Varying Length And Diameter • Nominal Pressure < 4 Atm , Balloon Catheters (Sizes 10 – 22 Mm) • Approved For Pediatric/Adult Use • Varying Length And Diameter • Nominal Pressure > 8 Atm , Balloon In Balloon Catheter • Quote In All Sizes , Fogarty Embolectomy Catheter • 4Fr/5Fr/6 Fr Sizes • Metal Rod At Tip Of The Catheter To Enable Angulations Up To 60 Degrees , Atrial Septostomy Catheter • 4Fr/5Fr/6Fr Sizes , Detachable Balloon , Vascular Plugs- Fda Approved , Vascular Plugs- Ce Marked , Vascular Plugs- Approved By Dcgi , Radiofrequency Perforation Accessories • Compatible With Beyliss System , Group-D10 , Pda Coils Made Of Steel • 0.035, 0.038 Inches • Sizes Ranging From 2 X 2 To 15 X 15 , Pda Coils Made Of Nitinol • 0.035, 0.038 Inches • Sizes Ranging From 2 X 2 To 15 X 15 , Pda Coils Made Of Platinum • 0.035, 0.038 Inches • Sizes Ranging From 2 X 2 To 15 X 15 , 0.052 Inch Pda Coils Made Of Nitinol • Sizes Ranging From 2 X 2 To 15 X 15 , 0.052 Inch Pda Coils Made Of Platinum • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils (0.018 Inch) • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils (0.035 Inch) • Sizes Ranging From 2 X 2 To 15 X 15 , Embolisation Coils (0.052 Inch) • Sizes Ranging From 2 X 2 To 15 X 15 , Park Blade Septectomy Catheter , Group-D11 , Balloon Expandable Pulmonary Artery And Aortic Stents – Approved For Pediatric/Adult Use • Available In Various Sizes , Self Expanding Pulmonary Artery And Aortic Stents- • Approved For Pediatric/Adult Use • Available In Various Sizes , Hydrophilic Diagnostic Guide Wire - Radifocus (Regular Length, Regular Stiffness) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be Between 120-150 Cm Long , Hydrophilic Diagnostic Guide Wire -‘Radifocus’ (Exchange Length, Regular Stiffness) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be 260 Cm Long , Hydrophilic Diagnostic Guide Wire - Radifocus (Regular Length, Extra-Stiff) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip O Should Be Between 120-150 Cm Long , Hydrophilic Diagnostic Guide Wire - Radifocus (Exchange Length, Extra-Stiff) • Must Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Have Superelastic Alloy Core • Should Have Super Flexible Wire Tip • Should Be Available In Straight And Angled Tip • Should Be 260 Cm Long , Exchange Length 0.035 Inch Guidewire Dedicated For Vsd Device Closure– Noodle Type , Special Introducer Sheath For Transseptal Puncture • Should Include A Dilator And Sheath • Dilator Should Provide Smooth Transition With Septal Puncture Needle • Should Be Available In Varying Sizes • Radio-Opaque Tip Marker For Precise Visualization Of Sheath • Should Be Kink And Collapse Resistant • Should Be Flexible , Special Long Sheath With Side Arm Having Hausdorf-Lock Curve For Asd Device Closure • Variable Lengths And Sizes , Special Long Sheaths With Side Arm Having Mullins Curve, Balkans Curve, 180 Curve And Other Curves • Variable Lengths And Sizes , Ptca Inflation Device- (Maximum Pressure Upto 10 Atm) • Luminescent Analog Pressure Gauge With Maximum Pressure Up To 10 Atm • Efficient Locking System To Maintain High Pressure • Rapid Inflation And Deflation • Clear Barrel For Easy Visualization Of De-Bubbling • Ergomatric And User Friendly Hand Held Design , Group E -12 , Disposable Radiation Protection Pad -Radial Single Layer, Sterilized Packed, Non-Vinyl, Lead (Pb)-Free And Light Weight Absorbable Radial Drape For Protection From Scattered Radiation During Interventional Procedures Like Radial Angioplasty, Peripheral & Ir Etc. Should Have Barc Test Certificate, And Lead Equivalency Must Be At Least 0.125Mmpb And Attenuation Shield Size: 406Mmx305mm Mandatory Document Need To Be Submitted: • Third-Party Environmental Safety Document. • Clinical Proof Of Attenuation. Disposable Radiation Protection Pad -Femoral And Subclavian Single Layer, Sterilized Packed, Non-Vinyl, Lead (Pb) -Free And Light Weight Absorbable Femoral Drape For Protection From Scattered Radiation During Interventional Procedures Like Ep Ablation, Cto Etc. Should Have Barc Test Certificate, And Lead Equivalency Must Be At Least 0.125Mmpb And Attenuation Shield Size: 406Mmx305mm Mandatory Document Need To Be Submitted: • Third-Party Environmental Safety Document. • Clinical Proof Of Attenuation. No Brainer Cap Non-Lead Single Layer Head Cover, Non-Vinyl, Lead (Pb) -Free X-Ray Attenuation, Light Weight Surgical Cap For Radiation Safety In All Fluoro Labs And Must Be Fit All Head Sizes. Should Have A Lead Equivalency Must Be At Least 0.125Mmpb. Weight Should Not Be More Than 95Grams And Attenuation Shield Size: 559Mmx76mm Mandatory Document Need To Be Submitted: • Third-Party Environmental Safety Document. • Clinical Proof Of Attenuation , Group -F1 , Hydrophilic Dignostic Guide Wire - (Regular Length, Regular Stiffness) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • Should Be Between 120-180 Cm Long • Short Floppy Tip 3-8 Cm Long , Hydrophilic Diagnostic Guide Wire - (Exchange Length, Regular Stiffness) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • Should Be 260 Cm Long • Short Floppy Tip 3-8 Cm Long , Hydrophilic Diagnostic Guide Wire - (Exchange Length, Regular Stiffness) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • Should Be 300 Cm Long • Short Floppy Tip 3-5 Cm Long , Hydrophilic Diagnostic Guide Wire - (Regular Length, Extra-Stiff) - • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • Should Be Between 120-180 Cm Long • Short Floppy Tip 3-8 Cm Long , Hydrophilic Diagnostic Guide Wire - (Exchange Length, Extra-Stiff) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • 3-5 Cm Long Tip • Should Be 260 Cm Long , Hydrophilic Diagnostic Guide Wire - (Exchange Length, Extra-Stiff) • Should Be Available In 0.025, 0.032, 0.035 And 0.038 Inches Size • Should Be Available In Straight And Angled Tip • 3-5 Cm Long Tip • Should Be 300 Cm Long , Ptfe Coated Extrastiff Shaft Strength Wire- Backup Meier( Regular Length) • Extremely Stiff Stainless Steel Shaft Core • Flexible Short Length ‘J’ Shaped Tip Which Should Be Highly Radio-Opaque . • 0.035 Inches • 185 Cm Long , Ptfe Coated Extra Stiff Shaft Strength Exchange Wire- Backup Meier (Exchange Length) • Extremely Stiff Stainless Steel Shaft Core • Flexible Short Length ‘C’ Shaped Tip Which Should Be Highly Radio-Opaque . • 0.035 Inches • 300 Cm Long , Nitinol 0.014 Inch Guidewire (Exchange Length)Straight And Angled • With Hydrophilic Coating • 260-300 Cm Long • With And Without Flexible Tip , Nitinol 0.018 Inch Guidewire (Exchange Length) • Straight And Angled • With Hydrophilic Coating • 260-300 Cm Long • With And Without Flexible Tip , Group -F 2 , Heavy Duty Nitinol Alloy Extra Support Wire ( Regular Length) • 0.014 Inches • Nitinol Alloy • With Angled Tip-3-5 Cm Long • Tip With Platinum/Platinum Alloy For Optimum Visualisation • With Tfe Coating • 180 Cm Long , Heavy Duty Nitinol Alloy Extra Support Wire (Exchange Length) • 0.014 Inches • Nitinol Alloy • With Angled Tip-3-5 Cm Long • Tip With Platinum/Platinum Alloy For Optimum Visualisation • With Tfe Coating • 270-300 Cm Long , Heavy Duty Nitinol Extra Support Wire( Regular Length) • 0.018 Inches • Nitinol Alloy • With Angled Tip-3-5 Cm Long • Tip With Platinum/Platinum Alloy For Optimum Visualization • With Tfe Coating • 180 Cm Long , Heavy Duty Nitinol Extra Support Wire (Exchange Length) • 0.018 Inches • Nitinol Alloy • With Angled Tip: 3-5 Cm Long • Tip With Platinum/Platinum Alloy For Optimum Visualisation • With Tfe Coating • 270-300 Cm Long , Steerable High Support .014 Inch Guidewire • Ptfe/Duraglide Coated • Distal Radiopaque Tip 3 Cm Long • Straight And J Curve • 180Cm Long , Steerable High Support .014 Inch Guide Wire ( Exchange) • Ptfe/Duraglide Coated • Distal Radiopaque Tip 3 Cm Long • Straight And J Curve • 260-300Cm Long , Cobra Catheter • 4French/5French/6French • 65-125 Cm Long • 021-038 Compatible • In Various Standard Curves . , Sos Omni Catheter • 035-038 Compatible • 80 Cm Long , Tapered Straight Catheter • 4French/5French/6French • 70,100 Cm Long • .035 Inch Compatible , Picard Catheter • 4French/5French/6French • 035-038 Compatible • In Various Standard Lengths. , Group -F3 , Renal Double Curve Catheter • In Various Standard Lengths And Curves , Head Hunter Catheter • In Various Standard Lengths And Curves • 035-038 Compatible • 100Cm Long , Simmons/ Sidewinder Catheter • In Various Standard Lengths And Curves • 035-038 Compatible • 100Cm Long , Pre -Shaped Catheter For Uterine Artery Embolisation • In Various Standard Lengths And Curves , Vertebral Catheter • In Various Standard Lengths And Curves , Coeliac Axis Catheter • In Various Standard Lengths And Curves , Shepherd’S Hook Catheter • In Various Standard Lengths And Curves , Micro Catheters (Coiled Stainless Steel Construction) • In Various Standard Lengths And Curves • 2-3.8F Size • .010-.022 Inch Wire Compatible • With Radioopaque Marker At Tip , Micro Catheters (Braided Nitinol Construction) • In Various Standard Lengths And Curves • 2-3.8F Size • .010-.022 Inch Wire Compatible • With Radioopaque Marker At Tip , Straight Introducer Sheath (Standard Length) With Hydro Philic Introducer Guide Wire • Sizes From 4French/5French/ 6 French/7 French/8Frenc/9French • Between 7-11 Cm Long • With 0.035 Or 0.038 Inch Hydrophilic Mini Guide Wire • With Plastic Cannula For Arterial Puncture , Group -F4 , Straight Long Introducer Sheath With Hydrophilic Introducer Guide Wire • Sizes From 4French/5French/ 6 French/7 French/8Frenc/9French • 16 Cm Long • With 0.035 Or 0.038 Inch Hydrophilic Guide Wire • With Plastic Cannula For Arterial Puncture , Straight Reinforced Sheath With Hydrophilic Coating • Sizes From 6French /7French /8Frenc/9French/10French/11French • Between 7-11 Cm Long • With 0.035 Or 0.038 Inch Guide Wire Compatible • With Radio-Opaque Tip , Group -F5 , Guiding Catheter For Peripheral Vascular Use – – Should Be Braided With Low Friction Inner Layer - Should Have Atraumatic Soft Tip - Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature, Including Renal Double Curve, Cobra, Multi-Purpose And Other Shapes - Should Have Od Of 6F-8F Available - Should Have The Largest Id For Each Od - Should Have Lengths Ranging From 55-90 Cm , Guiding Catheter For Peripheral Vascular Use – – Should Be Braided With Low Friction Inner Layer - Should Have Hydrophilic Coating - Should Have Atraumatic Soft Tip - Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature. - Should Have Od Of 6F-10F Available - Should Have The Largest Id For Each Od - Should Have Lengths Ranging From 55-125 Cm , Guiding Catheter For Peripheral Vascular Use – – Should Be Braided With Low Friction Inner Layer - Should Have Hydrophilic Coating - Should Have Atraumatic Soft Tip - Should Be Available In Various Tip Shapes And Curves For Access To Different Parts Of The Peripheral Vasculature. - Should Have Od Of 5F Available With The Largest Od - Should Have A Minimum Length Of 55 Cm Or More , Long Sheath For Peripheral Vascular Access– - Should Be Kink Resistant With A Reinforcement Mechanism - Should Be Low Friction With Inner Coating To Allow Catheter Manipulation - Should Have Distal Radio-Opaque Tip For Enhanced Visibility On Fluoroscopy - Should Have Smooth Transition From Dilator To Sheath - Should Have A Proximal Hemostasis Valve/Provision For Tuohyborst Valve - Should Be Color Coded For Size Identification - Should Be Available In Various Sizes Of Inner Diameters And Various Lengths And Have The Largest Id Available , Long Sheath For Carotid Access – - Should Be Kink Resistant With A Reinforcement Mechanism - Should Be Low Friction With Inner Coating To Allow Catheter Manipulation - Should Have Distal Radio-Opaque Tip For Enhanced Visibility On Fluoroscopy - Should Have Smooth Transition From Dilator To Sheath - Should Have A Proximal Hemostasis Valve/Provision For Tuohyborst Valve - Should Be Color Coded For Size Identification - Should Be Available In 4F-8F Size With The Largest Id - Should Have A Minimum Length Of 90 Cm Or More , Long Sheath For Contra-Lateral Iliac/Femoral Access – - Should Be Kink Resistant With A Reinforcement Mechanism - Should Be Low Friction With Inner Coating To Allow Catheter Manipulation - Should Have Distal Radio-Opaque Tip For Enhanced Visibility On Fluoroscopy - Should Have Smooth Transition From Dilator To Sheath - Should Have A Proximal Hemostasis Valve/Provision For Tuohyborst Valve - Should Be Color Coded For Size Identification - Should Be Available In 4F-9F Size With The Largest Id - Should Have Lengths Ranging From 40- 110 Cm , Group -F6 , Long Sheath For Renal Access – - Should Be Kink Resistant - Should Be Low Friction With Inner Coating To Allow Catheter Manipulation - Should Have Distal Radio-Opaque Tip For Enhanced Visibility On Fluoroscopy - Should Have Smooth Transition From Dilator To Sheath - Should Have A Proximal Hemostasis Valve/Provision For Tuohyborst Valve - Should Be Color Coded For Size Identification - Should Be Available In 5F-7F Size With The Largest Id - Should Be At Least 55 Cm Long , High Pressure Angioplasty Balloon For Peripheral Vascular Use – - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In Various Outer Diameters And Balloon Lengths And Various Shaft Lengths , High Pressure Angioplasty Balloon For Peripheral Vascular Use – - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In Various Outer Diameters And Balloon Lengths , High Pressure Angioplasty Balloon For Peripheral Vascular Use – - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In Various Outer Diameters And Balloon Lengths - Should Be Available In Various Shaft Lengths , High Pressure Angioplasty Balloon For Peripheral Vascular Use – - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In 4-10 Mm (In 1 Mm Increments) And 12 Mm Diameters And 2-10 Cm Balloon Length - Should Have A Shaft Size Of 75-135 Cm , High Pressure Angioplasty Balloon For Peripheral Vascular Use– - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In 4-12 Mm Diameter And 2-10 Cm Balloon Length - Should Have A Shaft Size Of 75-135 Cm , High Pressure Angioplasty Balloon For Peripheral Vascular Use– - Should Have Rated Burst Pressure > 14 Atmosphere - Should Have Hydrophilic Coating - Should Be Available In 4-12 Mm Diameter And 2-10 Cm Balloon Length - Should Have A Shaft Size Of 75-135 Cm , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Have A Burst Pressure Of At Least 10 Atmosphere (At Least 6 Atmosphere For Larger Balloons) - Should Have Hydrophilic Coating - Should Be Available In Various Sizes Of Od And Balloon Lengths - Should Be Available In Various Shaft Lengths , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Be Non-Compliant Or Semi-Compliant - Should Have Hydrophilic Coating - Should Be Available In All Ods Of 3-10 Mm And 12 Mm And Balloon Length Of 2-10 Cm. - Should Have Burst Pressure Of At Least 10 Atmosphere (The 12 Mm Od Balloon Should Have A Burst Pressureof At Least 6 Atmosphere) - Should Pass Through A Maximum 6F Sheath (The 12 Mm Od Balloon Should Pass Through A Maximum 7Fsheath) - Should Have A Shaft Length 80-135 Cm , Group -F7 , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Have A Burst Pressure Of At Least 10 Atmosphere (At Least 6 Atmosphere For Larger Balloons) - Should Have Hydrophilic Coating - Should Be Available In Various Sizes Of Od And Balloon Lengths - Should Be Available In Various Shaft Lengths , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Be Non-Compliant Or Semi-Compliant - Should Have Hydrophilic Coating - Should Be Available In Od Of 3-10 Mm And 12 Mm And Balloon Length Of 2-10 Cm. - Should Have Burst Pressure Of At Least 10 Atmosphere (The 12 Mm Od Balloon Should Have A Burst Pressureof At Least 6 Atmosphere) - Should Pass Through A Maximum 6F Sheath (The 12 Mm Od Balloon Should Pass Through A Maximum 7Fsheath) - Should Have A Shaft Length 80-135 Cm , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Have A Burst Pressure Of At Least 10 Atmosphere (At Least 6 Atmosphere For Larger Balloons) - Should Have Hydrophilic Coating - Should Be Available In Various Sizes Of Od And Balloon Lengths - Should Be Available In Various Shaft Lengths , Peripheral Balloon Catheter – - Should Be 0.035” Compatible - Should Be Over The Wire - Should Be Non-Compliant Or Semi-Compliant - Should Have Hydrophilic Coating - Should Be Available In All Ods Of 3-10 Mm And 12 Mm And Balloon Length Of 2-10 Cm. - Should Have Burst Pressure Of At Least 10 Atmosphere (The 12 Mm Od Balloon Should Have A Burst Pressureof At Least 6 Atmosphere) - Should Pass Through A Maximum 6F Sheath (The 12 Mm Od Balloon Should Pass Through A Maximum 7Fsheath) - Should Have A Shaft Length 80-135 Cm , Peripheral Balloon Catheter With Large Diameter - Should Be 035” Compatible - Should Be Over The Wire - Should Have Hydrophilic Coating - Should Have Od Of 14 Mm And More - Various Lengths Of The Balloon Should Be Available - Should Be Mounted On Various Shaft Lengths , Peripheral Balloon Catheter With Large Diameter – - Should Be 035” Compatible - Should Be Over The Wire - Should Have Hydrophilic Coating - Should An Od Of At Least 14 Mm - Various Lengths Of The Balloon Should Be Available - Should Be Mounted On Various Shaft Lengths , Peripheral Balloon Catheter With Large Diameter – - Should Be 035” Compatible - Should Be Over The Wire - Should Have Hydrophilic Coating - Should An Od Of At Least 14 Mm - Various Lengths Of The Balloon Should Be Available - Should Be Mounted On Various Shaft Lengths , Peripheral Balloon Catheter – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Have Hydrophilic Coating - Should Be Available In Various Balloon Diameters - Should Be Available In Various Lengths Of The Balloon - Should Be Available In Various Shaft Lengths , Group -F9 , Peripheral Compliant Balloon With Large Diameter – - Should Be .035” Compatible - Should Have Od Ranging From 10-46 Mm - Should Have Shaft Length >90 Cm - Should Have Shaft Of Not More Than 8F Size - Should Pass Through A 12F Sheath , Peripheral Stent Balloon Mounted – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Made Of Stainless Steel Alloy - Should Have Balloon Od In The Range Of 4-7 Mm - Should Have Balloon/Stent Lengths In The Range Of 12-25 Mm - Should Have Shaft Lengths Of 80-150 Cm , Peripheral Stent Balloon Expandable – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Made Of Stainless Steel Alloy - Should Have Balloon Od In The Range Of 4-7 Mm - Should Have Balloon/Stent Lengths In The Range Of 12-25 Mm - Should Have Shaft Lengths Of 80-150 Cm , Group -F10 , Peripheral Stent Balloon Expandable - - Should Be .014/.018” Compatible - Should Be For Rapid Exchange - Should Be Made Of Stainless Steel Alloy - Should Have Balloon Od In The Range Of 4-7 Mm - Should Have Balloon/Stent Lengths In The Range Of 12-25 Mm - Should Have Shaft Lengths Of 80-150 Cm , Peripheral Stent Balloon Expandable – - Should Be 035” Compatible - Should Be Made Of Stainless Steel Or Cobalt Chromium - Should Be Quoted Either In Open Cell Or Closed Cell Design - Should Be Available In Various Balloon Ods - Should Have Various Balloon/Stent Lengths Available - Should Have A Shaft Length Of 75-135 Cm , Peripheral Stent Balloon Mounted – - Should Be 035” Compatible - Should Be Made Of Stainless Steel Or Cobalt Chromium - Should Be Quoted Either In Open Cell Or Closed Cell Design - Should Be Available In Various Balloon Ods - Should Have Various Balloon/Stent Lengths Available - Should Have A Shaft Length Of 75-135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel Or Cobalt Chromium - Should Be Quoted Either In Open Cell Or Closed Cell Design - Should Be Available In Various Balloon Ods - Should Have Various Balloon/Stent Lengths Available - Should Have A Shaft Length Of 75-135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Have A Tandem Architecture Design - Should Have All Balloon Ods From 5-10 Mm In 1 Mm Increments - Should Have Available Various Balloon/Stent Lengths Of 20 To 55Mm - Should Have A Shaft Length Of 75 -135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Have A Tandem Architecture Design - Should Have All Balloon Ods From 5-10 Mm In 1 Mm Increments - Should Have Available Various Balloon/Stent Lengths From 20 To 55 Mm - Should Have A Shaft Length Of 75 -135 Cm , Peripheral Stent Balloon Expandable - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Have A Tandem Architecture Design - Should Have All Balloon Ods From 5-10 Mm In 1 Mm Increments - Should Have Available Various Balloon/Stent Lengths From 20 To 55 Mm - Should Have A Shaft Length Of 75 -135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Be Laser Cut Slotted Tube With Closed Cell Design - Should Have Balloon Ods From 5-25 Mm, Bare Or Balloon Mounted - Should Have Available Various Balloon Stent/Lengths From 2-6 Cm - Should Have A Shaft Length Of Up To 135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Be Laser Cut Slotted Tube With Closed Cell Design - Should Have Balloon Ods From 5-25 Mm, Bare Or Balloon Mounted - Should Have Available Various Balloon Stent/Lengths From 2-6 Cm - Should Have A Shaft Length Of Up To 135 Cm , Peripheral Stent Balloon Expandable – - Should Be .035” Compatible - Should Be Made Of Stainless Steel - Should Be Laser Cut Slotted Tube With Closed Cell Design - Should Have Balloon Ods From 5-25 Mm, Bare Or Balloon Mounted - Should Have Available Various Balloon Stent/Lengths From 2-6 Cm - Should Have A Shaft Length Of Up To 135 Cm , Group- F11 , Self-Expanding Peripheral Stent – - Should Be .014/018” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Have The Least Lesion Crossing Profile For All Stent Diameters - Should Be Available In Various Stent Diameters Of 6-10 Mm - Should Be Available In Various Stent Lengths From 20-40 Mm - Should Have A Shaft Length Of At Least 110 Cm , Self-Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Have The Least Lesion Crossing Profile For All Stent Diameters - Should Be Available In Various Stent Diameters Of 6-10 Mm - Should Be Available In Various Stent Lengths From 20-40 Mm - Should Have A Shaft Length Of At Least 110 Cm , Self-Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Have The Least Lesion Crossing Profile For All Stent Diameters - Should Be Available In Various Stent Diameters Of 6-10 Mm - Should Be Available In Various Stent Lengths From 20-40 Mm - Should Have A Shaft Length Of At Least 110 Cm , Self-Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Laser Cut Open Cell Nitinol Tube - Should Have A Low Lesion Crossing Profile - Should Be Available In All Stent Diameters Of 6-10 Mm - Should Be Available In Stent Lengths Of 2-6 Cm - Should Be On A Shaft Length Of 110-140 Cm , Self-Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Laser Cut Open Cell Nitinol Tube - Should Have A Low Lesion Crossing Profile - Should Be Available In All Stent Diameters Of 6-10 Mm - Should Be Available In Stent Lengths Of 2-6 Cm - Should Be On A Shaft Length Of 110-140 Cm , Self-Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Over The Wire - Should Be Laser Cut Open Cell Nitinol Tube - Should Have A Low Lesion Crossing Profile - Should Be Available In All Stent Diameters Of 6-10 Mm - Should Be Available In Stent Lengths Of 2-6 Cm - Should Be On A Shaft Length Of 110-140 Cm , Self Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Of Rapid Exchange Type - Should Be Made Of Nitinol - Should Be Available In Stent Lengths Of 3-4 Cm - Should Have A Minimum Shaft Length Of 110 Cm , Self Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Of Rapid Exchange Type - Should Be Made Of Nitinol - Should Be Available In Stent Lengths Of 3-4 Cm - Should Have A Minimum Shaft Length Of 110 Cm , Self Expanding Peripheral Stent – - Should Be .014/.018” Compatible - Should Be Of Rapid Exchange Type - Should Be Made Of Nitinol - Should Be Available In Stent Lengths Of 3-4 Cm - Should Have A Minimum Shaft Length Of 110 Cm , Self-Expanding Peripheral Stent – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Be Available In Various Outer Diameters - Should Be Of Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm , Group -F12 , Self-Expanding Peripheral Stent – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Be Available In Various Outer Diameters - Should Be Of Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm , Self-Expanding Peripheral Stent – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol - Should Be Available In Various Outer Diameters - Should Be Of Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm , Self-Expanding Peripheral Stent – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Laser Cut From Single Nitinol Tube With No Welds - Should Be Available In Outer Diameters Of 5-14 Mm - Should Be Available In Stent Lengths Of 2-15 Cm - Should Be On A Shaft Length Of 80-140 Cm - Should Be Available In Various Lengths Of 20-100 Mm , Peripheral Bio-Degradable Or Absorbable Metal Stent - Should Be Balloon Mounted Or Self-Expanding Type - Should Be Available In Outer Diameters Of 4-8 Mm - Should Be Available In Various Lengths Of 20-100 Mm , Group -F13 , Dedicated Peripheral Vascular Bifurcation Stent - Should Be Balloon Mounted - Should Be Available In Different Diameters And Lengths Of The Stent , Self Expanding Peripheral Covered Stents – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Fabric Coating - Should Be Available In Various Outer Diameters - Should Be Available In Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm. , Self Expanding Peripheral Covered Stents – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Fabric Coating - Should Be Available In Various Outer Diameters - Should Be Available In Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm , Self Expanding Peripheral Covered Stents – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Fabric Coating - Should Be Available In Various Outer Diameters - Should Be Available In Various Stent Lengths - Should Be On A Shaft Length Of 80-140 Cm. , Self Expanding Peripheral Covered Stents – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Ptfe Coating On The Inner Lumen - Should Be Available In Outer Diameters Of 5-13 Mm - Should Be Avaiable In Stent Lengths Of 2-15 Cm - Should Be On A Shaft Length Of 75-140 Cm. , Self Expanding Peripheral Covered Stents – - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Ptfe Coating On The Inner Lumen - Should Be Available In Outer Diameters Of 5-13 Mm - Should Be Avaiable In Stent Lengths Of 2-15 Cm - Should Be On A Shaft Length Of 75-140 Cm. , Self Expanding Peripheral Covered Stents - Should Be .035” Compatible - Should Be Over The Wire - Should Be Made Of Nitinol With Ptfe Coating On The Inner Lumen - Should Be Available In Outer Diameters Of 5-13 Mm - Should Be Avaiable In Stent Lengths Of 2-15 Cm - Should Be On A Shaft Length Of 75-140 Cm. , Covered Stent For Transjugular Intrahepatic Porto-Systemic Shunt - Should Be .035/038” Compatible - Should Be Made Of Nitinol With Fabric Coating - Should Be With Or Without A Distal Uncovered Portion - Should Be Available In Various Outer Diameters And Stent Lengths - Should Be Compatible With The Quoted Tips Set , Covered Stent For Transjugular Intrahepatic Porto-Systemic Shunt - Should Be .035/038” Compatible - Should Be Made Of Nitinol With Ptfe Coating On Inner Lumen - Should Be With A Distal At Least 2 Cm Uncovered Portion - Should Be Available In All Outer Diameters Of 8,10,12 Mm - Should Be Available In All Stent Lengths Of 4,5,6,7,8 Cm - The Delivery System Should Be At Least 75 Cm Long - Should Be Compatible With The Quoted Tips Set , Embolisation Coils - Should Be .014/018” Compatible - Should Be Made Of Platinum With Synthetic Fibres - Should Be Non Tapering/Straight - Should Be Mr Compatible - Should Be Available In Any Or More Of The Following Diameters: 2-10 Mm - Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated , Group- F14 , Embolisation Coils -Should Be .014/018” Compatible - Should Be Made Of Platinum With Synthetic Fibres - Should Be Mr Compatible - Should Taper From A Larger To A Smaller End - Should Be Available In Any Or More Of The Following Diameters: 3-10 Mm - The Diameter To Tapered End For Tapering Type Coils Should Be Stated - Should Be Of Various Lengths; The Length Of The Coil At Each Diameter Should Be Stated , Embolisation Coils - Should Be .035/038” Compatible - Should Be Non Tapering/Straight - Should Be Made Of Platinum With Synthetic Fibres - Should Be Mr Compatible - Should Be Available In The Following Sizes: Diameter 3-15 Mm And Length 2-15 Cm , Embolisation Coils - Should Be .035/038” Compatible - Should Be Made Of Platinum With Synthetic Fibres - Should Be Mr Compatible - Should Be Tapering From A Larger To A Smaller End - Should Be Available In Following Sizes: Diameter 5-10 Mm And Length 2-15 Cm - The Diameter To Tapered End For Tapering Type Coils Should Be Mentioned , Embolisation Coils - Should Be .035/038/052” Compatible - Should Be Non Tapering/Straight - Should Be Made Of Stainless Steel With Synthetic Fibres - Should Be Available In The Following Sizes: Diameter 3-15 Mm And Length 2-15 Cm , Coil Pusher Wire For 0.014/0.018” Coils, Compatible With The Quoted Microcatheters , Polyvinyl Alcohol Particles For Peripheral Vascular Embolization - Should Be Of Non-Uniform Size - Should Undergo Rapid Clumping In The Vessels - Should Cause Non-Uniform Vessel Occlusion - Should Be Available In A Broad Range Of Sizes (90 Microns- 1400 Microns) , Microspheres For Peripheral Vascular Embolization - Should Be Hydrophilic - Should Be Micro-Porous And Uniform Sized Spheres - Should Be Non-Aggregating - Should Be Deformable For Ease Of Passage Through Smaller Vessels - The Size Of Spheres Should Range From40-1200 Micrometers , Gelfoam Sheet For Vascular Embolization , Non-Adhesive Liquid Polymer For Controlled Embolization - Should Be Ethylene Vinyl Copolymer In Dimethylsulfoxide Solution - Should Be Supplied In Various Concentrations For Use Depending On Lesion Morphology , Adhesive Liquid Polymer For Vascular Embolization - Should Be N-Butyl Cyanoacrylate , Group -F15 , Tantalum Powder -Should Be Useful For Improved Visualization During N-Butyl Cyanoacrylate Embolization - Should Be Supplied As Finely Ground Powder , Lipiodol - The Material Should Be Iodised Oil, Containing Ethyl Esters Of Iodized Fatty Acids Of Poppy Seed Oil - The Iodine Content Should Be A Minimum Of 480 Mg/Ml - Should Useful As Opacifying Agent For N-Butyl Cyanoacrylate On Fluoroscopy And An Organic Diluent For Thisagent - Should Be Supplied In 10 Ml Ampoules , Sclerosant For Intravenous Embolization - The Compound Should Be Sodium Tetradecyl Sulfate - Should Be Available In Various Concentrations For Use Depending On Lesion Type , Sclerosant For Intravenous Embolization - The Compound Should Be Aetoxisclerol - Should Be Available In Various Concentrations For Use Depending On Lesion Type , Medical Grade Ethanolamine Oleate For Vascular Embolization , Detachable Balloon For Embolization - Detachable Balloons With Radioopaque Marker With And Without Self-Sealing Valve - 0.1 Cc – 3 Cc Or More In Capacity - Please Specify The Make And Capacity Of The Balloons (Latex/Silicon). - The Catheter Shaft Should Be Of At Least 120 Cm In Length , Transjugular Liver Biopsy Set - Should Include Angled Tip Needle Advanced Through Percutaneously Introduced Liver Access Set - Should Have A Firing Spring Mechanism - Needle Gauge Should Be Available In 18 And 19G And Needle Length Should Be 45-60 Cm - The Needle Throw Distance Should Be Not More Than 2 Cm - Should Include The Check-Flo Valve Adapter, Stiffening Cannula Curved And Straight Catheter And Introducer Sheath (Upto 7F Size) , Transjugular Intrahepatic Porto-Systemic Shunt Access Set - Should Include A Micropuncture Introducer Set -Should Include An Introducer Sheath That Should Be No More Than 10F Size, At Least 38 Cm Long And 035/038”Compatible - The Sheath Should Provide Maximum Flexibility Without Getting Kinked - The Sheath Should Have Proximal Check Flo Mechanism - The Sheath Should Have Distal Radiopaque Tip To Indicate Sheath Tip On Fluoroscopy - The Set Should Also Include A Needle Of 16G And At Least 50 Cm Long With Angled Tip To Facilitate Directiontowards Portal Vein - There Should Be A Curved/Angled Catheter, A Straight Catheter And A Centimeter Sizing Catheter Incorporated In The Set For The Various Steps Of The Procedure , Transjugular Liver Access Set (10F) For Various Diagnostic And Interventional Liver Procedures - Should Include A 10F And At Least 38 Cm Long Introducer Sheath - Should Include A Stiffening Cannula Of At Least 14 Gauge And Length Of At Least 51 Cm - Should Include A Trochar With Stylet That Is 035/038” Compatible And At Least 60 Cm Long , Transjugular Liver Access Set (7-9F) For Various Diagnostic And Interventional Liver Procedures - Should Include A 7F Or 9F Introducer Sheath That Is At Least 38 Cm Long - Should Include Needle With Angled Tip That Is 16F (For 9F) And 18G (For 7F) Sheath - Should Be 035/038” Compatible - The Needle Shoud Be At Least 50 Cm Long , Group -F16 , Ivc Filter - For Optimal Filtration Of Ivc Diameter Of Upto 40 Mm - Made Of Either Nitinol Or Stainless Steel - Catheter Carrier System Inner Diameter Should Be Of Maximum 12F - It Should Be Possible To Insert From Either Jugular Or Femoral Access - Should Be For Permanent Use , Ivc Filter - For Optimal Filtration Of Ivc Diameter Of Upto 28 Mm - Made Of Nitinol And Filter Length To Be Upto 38 Mm - Catheter Carrier System Inner Diameter Should Be Of Maximum 7F Size - It Should Be For Permanent Use - It Should Be Possible To Place The Filter From Femoral/Jugular/Antecubital Access , Ivc Filter - For Optimal Filtration Of Ivc Diameter Of Upto 28 Mm - Made Of Nitinol And Filter Length To Be Upto 55 Mm - Catheter Carrier System Inner Diameter Should Be Of Maximum 10 F Size - It Should Be For Optional (Permanent Or Retrievable) Use - It Should Be Possible To Place The Filter From Femoral/Jugular/Antecubital Access , Ivc Filter - For Optimal Filtration Of Ivc Diameter Of Upto 30 Mm - Made Of Conichrome Material And Filter Length Not More Than 50 Mm - Should Be Able To Be Placed Either Through Jugular Or Femoral Approach - Should Be For Optional (Permanent Or Temporary) Use , Percutaneous Mechanical Thrombectomy Catheter - Should Allow Treatment Of Fresh And Older Thrombotic Occlusions Of Peripheral Arteries - Should Combines Mechanical Fragmentation And Aspiration Alongwith Transport Of Debris Outside Thevascular System - Should Be Available In Both Antegrade Or Cross-Over Configurations - For Antegrade Access – Maximum Shaft Size Should Be 6F - For Cross-Over Access – Maximum Shaft Size Should Be 8F , Urokinase For Intra-Arterial Thrombolysis , Tissue Plasminogen Activator For Intra-Arterial Thrombolysis , Infusion Catheter - Should Have Multiple Side Ports - Should Provide An Infusion Length Of 5-15 Cm - Should Have A Catheter Tip Occluder - Should Have Attachment For Tuohy-Borst Side Arm Adapter - Should Have A Maximum Od Of 5F - Should Be Compatible With 035/038” Wire - Should Have A Shaft Length Of 60-100 Cm , Distal Embolic Protection Device - Should Be On A .014” Wire - Should Be Made Of Nitinol Material - Should Not Occlude Flow While In Placement - Should Completely Cover The Vessel Circumference At The Desired Placement Site To Afford Complete Protection - Should Have The Least Lesion Crossing Profile - Should Be Available In Various Sizes For Adapting To The Vessel Size , Distal Embolic Protection Device - Should Be On A .014” Wire - Should Be Made Of Nitinol Material - Should Not Occlude Flow While In Placement - Should Be Rapid Exchange Type - Should Allow Use Of A Separate .014/018” Wire For Initial Crossing Of The Lesion - Should Be Compatible With A 6F Guiding Catheter (0.066” Id) - Should Allow Longitudinal Wire Movement With Filter Remaining In Place - Should Be Available In 3-7 Mm Sizes , Group -F17 , Endovascular Stent Graft Device For Treatment Of Thoracic Aortic Aneurysms And Dissections - Device Should Be With Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Beeither Tapered Or Non-Tapered. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 26-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Upto 24F Shaft Size. - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ctangiography , Endovascular Stent Graft Device For Treatment Of Thoracic Aortic Aneurysms And Dissections - Device Should Be Without Proximal Barbs, Without Distal Bare Spring Configuration, And Should Be Eithertapered Or Non-Tapered. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 26-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Upto 24F Shaft Size. - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography , Endovascular Stent Graft Device For Treatment Of Thoracic Aortic Aneurysms And Dissection - Device Should Be Without Proximal Barbs, With Distal And/Or Proximal Bare Spring Configurations, Andshould Be Non-Tapered. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 26-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Up To 24F Shaft Size. - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography , Endovascular Stent Graft Device For Treatment Of Thoracic Aortic Aneurysms And Dissection - Device Should Be Without Proximal Barbs, With Distal And/Or Proximal Bare Spring Configurations, Andshould Be Tapered. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Upto 24F Shaft Size. - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography , Endovascular Stent Graft Device For Treatment Of Abdominal Aortic Aneurysms - Device Should Be With Or Without Proximal Barbs, With Or Without Distal Bare Spring Configuration, Andshould Be Either Tapered Or Non-Tapered. - Devices With Or Without Transrenal Or Suprarenal Fixation Should Be Quoted. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Aupto 24F Shaft Size. - The Limb Extensions Of The Main Device For Abdominal Aortic Applications Should Be Available In 12-22 Mmdiameter, With Or Without Flared Ends And Upto 12 Cm In Length - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ctangiography , Endovascular Stent Graft Device For Treatment Of Abdominal Aortic Aneurysms - Device Should Be With Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Beeither Tapered Or Non-Tapered. - Devices With Transrenal Or Suprarenal Fixation Should Be Quoted. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Aupto 24F Shaft Size. - The Limb Extensions Of The Main Device For Abdominal Aortic Applications Should Be Available In 12-22 Mmdiameter, With Or Without Flared Ends And Upto 12 Cm In Length - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ctangiography , Endovascular Stent Graft Device For Treatment Of Abdominal Aortic Aneurysms - Device Should Be Without Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Beeither Tapered Or Non-Tapered. - Devices With Transrenal Or Suprarenal Fixation Should Be Quoted. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Aupto 24F Shaft Size. - The Limb Extensions Of The Main Device For Abdominal Aortic Applications Should Be Available In 12-22 Mmdiameter, With Or Without Flared Ends And Upto 12 Cm In Length -The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ct Angiography , Endovascular Stent Graft Device For Treatment Of Abdominal Aortic Aneurysms - Device Should Be Without Proximal Barbs, With Or Without Distal Bare Spring Configuration, And Should Beeither Tapered Or Non-Tapered. - Devices Without Transrenal Fixation Should Be Quoted. - The Aortic Device Should Be Available In Any One Or More Of The Following Sizes: Od 12-44 Mm; Length 4-24 Cm. The Device Should Be Able To Be Advanced On Aupto 24F Shaft Size. - The Limb Extensions Of The Main Device For Abdominal Aortic Applications Should Be Available In 12-22 Mmdiameter, With Or Without Flared Ends And Upto 12 Cm In Length - The Manufacturer Should Agree To Supply The Size Customized To The Patient’S Anatomy Based On Ctangiography Covered Stent-Graft (Extender Or Iliac Or Contralateral Limb) In Diameters Ranging From 12-22 Mm And Lengths Ranging From 30-110 Mm For Over-The-Wire Delivery , Peripheral Vascular Catheter For Excision Of Artheroma- Should Have High Rotation Speed Of The Cutting Mechanism Without Causing Any Trauma To The Vessel – , Group -G1 , Permanent Pacemakers With All Leads And Accessories • Ssir, • All Single Chamber Modes And Basic Pacing Programmable Parameters. • Must Have Ventricular Capture Management • The Size Of Lead Must Be 7 F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Life Term Replacement Warranty • Direct Presence Of Parent Company In India (Not Only Through The Distributors) And Company Mustprovide Its Trained Technical Person For Each Implantation When Ever Required And For Follow Upprogramming When It Is Required. • Company Must Provide At Least One Programmer Exclusively To The Cardiology Department. • Company Must Quote Only The Latest Model Of Devices Commercially Available Department. , Group -H1 -Temporary Pacing Leads , Temporary Pacing Leads (Fda Approved) , Temporary Pacing Leads (Ce Approved) , Temporary Pacing Leads (Dcgi Approved) , Temporary Pacing Lead: Woven Interweaved, Braided , Temporary Pacing Leads: Balloon Floatable , Bipolar Catheter With Central Lumen038 Wire Compatible, Variable Length. , Screw - In Bipolar Temporary Pacing Lead = 65 Cm , Temporary Lead For Internal Cardio Version , Group -H1 -A Long Sheaths /Introducers , Long Sheaths /Introducers-Prefaced Valved Long Sheaths For Rfa With Mullins Curve, Multipurpose Curve, Other Curves, 7F To 9F, At Least 80- Cm Long, 0.038 Wire Compatible , Long Sheaths /Introducers-Bidirectonal, Steerable Long Sheaths With Variablereach, Autolock , Long Sheaths /Introducers-Brite Tip Intervention Sheath With Tip Visualization, Kink Resistant, Cold Shape Able With Silicon Coating , Long Sheaths /Introducers-Introducer Sheaths For Electrophysiology, With Various Swartz Curves Sl 0-4, Sr 0-4, 8F, 8.5F,9F , Long Sheaths /Introducers-Long Sheaths (Peel Away, Slit Table, With Breakable Valve) For Special Applications Like Coronary Sinus Intubation, Lateral Vein. Special Curves Like Renal, Hook Shape Etc , Long Sheaths /Introducers-Peel Away Introducer Sheaths With Break Away Hemostatic Valves For Pacing Leads, 5F-12F, 10 Cm – 30 Cm, Optional Infusion Side Port, Radio Opaque Edistal Tip And Multiple Curves , Long Sheaths /Introducers-Multiport Catheter Introducer Sheaths , Long Sheaths /Introducers-Pacing Lead Stabilizers , Long Sheaths /Introducers-3-D Braided Steerable Guiding Introducer Sheath, Supporting Transseptal Crossing, Atrial Ablation Procedures, With One Device Delivery System Having All 8 Steering Curves (Sl And Sr), Can Accommodate Multiple Sheath Sizes , Group -H2 (Diagnostic Ep Catheters) The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve,Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Used Like 6F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steelelectrodes/Platinum Electrodes Are Specified First. All Cables Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. Must Be Compatible To St Jude Ensite Precision , Quadripolar 6, Any , Quadripolar 5-7, Mullins , Quadripolar 5-7, Josephson , Quadripolar 5-7, His Bundle , Quadripolar 5-7 4-2, Mullins , Quadripolar 6, Mullins , Tripolar 5-7, Any , Tripolar 6, Josephson , Hexapolar 6, Any , Decapolar 5-7, Any , Decapolar 6, Any , Decapolar 5-7, Any, 2-5-2 , Decapolar 5-7, Any, 2-2-2 , Decapolar 5-7, Any, 2-2-2-10-2-2-2-10-2 , Ep Cathters For Pediatric Ep Work -Quadripolar 4 2-5-2- , Ep Cathters For Pediatric Ep Work -Quadripolar 4 , Ep Cathters For Pediatric Ep Work -Decapolar 4 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) - , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar 6 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar 5-7 2-5 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar 5 -7 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar5 -7 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Hexapolar 6 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Decapolar 6 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Decapolar 5 -7 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Decapolar 5 -7 , Woven Ep Diagnostic Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Decapolar 5 -7 , Woven Pediatric Ep Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) - , Woven Pediatric Ep Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar 4 , Woven Pediatric Ep Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Quadripolar 4 , Woven Pediatric Ep Catheters (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) -Decapolar 4 , Group –H3 [Special Catheters For Af, Flutter, Etc(Quote All Diameters, French Size, Different Electrodes Like Platinum Or Stainless Steel)] , Deflect Decaduapolar (20 Poles) For A Flutter----All Diameters , Deflectable Decapolar (10)(Pulm. Vein)---All Diameters , Deflectable Decaduapolar (20) (Pulm. Vein)—All Diameters , 2F Multipolar (> Ten Electrodes) For Mapping Through Coronary Vasculature , Basket Catheter With Accessory , Crista Catheter With Accessories , Other Special Ep Catheters , Pacing Catheter With Angiographic Capability • Variable Sizes • Bipolar Or Quadripolar With Appropriate Cable • Cvp Monitoring & Angiographic Facility , Paediatric Use: All The Above Catheters, Sheaths, Etc, For Paediatric Use - Implying Smaller French Size Like 4F,5F, With Certification For Use In Children , Group -H4 (Ablation Catheters) - (All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, Eg.) (All Items Differing In Make/Prices Need To Be Mentioned Separately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum Or Stainless Steel Etc) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters/ Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables /Accessories Separately. , Regular 4Mm All , Regular 8Mm , Regular 3.5Mm All , Regular 8Mm , Regular 4Mm , Cool Tip (Closed) Any , Irrigated Tip (Open) Any , Others Any , Bidirectional Any , Omnidirexnl Any , Group -H5 (Catheters, Cables, Accessories, For Carto System And Thermocool Infusion Pump) , Navistar Catheters Regular , Navistar Catheter Irrigated Tip , Location Patch Carto System (Refstar) , Connecting Cables For All Catheters , Access/Tubings For Cool Flow Pump And Any Other Accessories , Group -H5-A Catheters, Cables, Accessories For Endocardial Solutions (Esi) Accessories , Navex Patches , Balloon Array , Other Accessories (Quote Each Separately) , Catheters/Accessories For Loca Lisa , Reusable Defibrillation/Transcutaneous Pacing Patches (Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6) , Disposable Defibrillation/Transcutaneous Pacing Patches (Suitable For Equipment In Cath Lab, Ct2, Ct3, Ct6) , Defibrillation/Transcutaneous Pacing Patches For Use In Infants And Children , Cryo Catheters (And Accessories) For Ablation Of Arrhythmias In Children And Adults , Intra Cardiac Ultrasound/Echo Catheter For Guiding Rfa Compatible With The Existing Echo Machine At Neigrihms (Quote All Prices Of The Catheters And Accessories) , Disposable Electrocautery Patches For Rfa (Suitable For Stockert And Ept 1000 Ablators) Reusable Electrocautery Patches For Rfa (Suitable For Stockert And Ept 1000 Ablators) Electrocautery Pencils For Use In Dissection , Electrocautery Pencils For Use In Dissection , Group -H6 (Pacemaker Lead Extraction Systems -Mention Each System Price And Also Individual Accessories) , Laser Guided Lead Extraction System With Accessories (Fda/Ce Certified) , Rf Guided Lead Extraction System With Accessories (Fda/Ce Certified) , Other Extraction Systems (Fda/Ce Approved) , Accessories For Lead Extraction Like Locking Stylet, Other Accessories , Intracardiac Echocardiographic (Ice) Catheter , Lead Locking Device For Lead Extraction With Sizing From 0.38Mm To 0.58Mm Compatible With Any Make &All Range Of Leads, With Radiopaque Marker At The Tip, And A Proximal Connector And Mandrel To Deploy The Device. , Mechanical Dilator Sheath, With Bi-Directional Rotating 574 Degree, While Extending The Blade Just 0.02 Inches, With Flexible Shaft And A Static Outer Shaft. , Otherspecific Items For Advanced Cardiac Procedure , Balloon - Expanding Type Of Tavi (Transcatheter Aortic Valve Implantation) With All Standard Accessories For Implantation Different Sizes.Available Sizes:20Mm,21.5Mm,23Mm,24.5Mm,26Mm,27.5Mm,29Mm,30.5Mm,32Mm , Sirolimus Eluting Bioresorbable Coronary Vascular Scaffold System Having Various Diamter And Length Of Upto 40Mm , Coronary Intravascular Lithotripsy Catheter System With Foot Peddel . Sizes Available 2.5Mm, 2.75 Mm ,3.0Mm,3.5Mm& 4.0Mmand Length 12Mm , Ptca Balloon (Semi-Compliant) - • Monorail (Rapid Exchange) And Over-The-Wire (Otw) Balloons • Available In All Sizes And Lengths
|