Tender For Annual Rate Contract For Maintenance Of Various Civil Repair In Municipal Area Buildings. - Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm 2 Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and upto 40 mm 3 Dismantling old plaster or skirting raking out joints and cleaning thesurface for plaster including disposal of rubbish to the dumpingground within 50 metres lead. 4 Dismantling Stone MasonryRubble stone masonry in cement mortar. 5 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m 6 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stoneaggregate 20 mm nominal size). 7 Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:4 (1 cement : 4 coarse sand) 8 Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:4 (1 cement : 4 coarse sand)Extra for random rubble masonry with hard stone in superstructure above plinth level and upto two stories. Extra for coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto two stories. 9 Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete. 10 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 11 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. 12 Random rubble masonry with hard stone in foundation and plinth : Cement mortar 1:4 (1 cement : 4 coarse sand) 13 Brick masonry work with First class FPS bricks (min. 10.5 Mpa) in cement mortar with mechanical mixer in substructure/ super structure at all levels complete as per clause 1300 and 2200 of MoRT&H specification including all material, labour, scaffolding etc but excluding pointing and plastering.In cement mortar 1:4 (1 cement : 4 coarse sand) 14 Cement plastering including T&P, scaffolding, material and completelabour, including cost of water, curing, racking of joints etc. with 12mm cement plaster of mix : including Providing /mixing of syntheticfibers compulsorily complying with IS 16481:2022 of 06 mm/12 mmlength to be mixed @ 0.25% by weight of Cement i.e. 125 gms per50 kg Cement up to 900 gms per cum of Concrete/ mortar1:6 (1 cement : 6 fine/ coarse sand) 15 Extra for plastering exterior walls of height more than 10 m fromground level for every additional height of 3 m or part there of 16 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over andincluding base coat of water proofing cement paint applied @ 2.20kg/ 10 sqm) 17 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shadeNew work (two or more coats) over and including priming coat withcement primer. 18 Repairs to plaster of thickness 12mm to 20mm in patches of area2.5 sq. metres and under including cutting the patch in propershape, raking out joints and preparing and plastering the surface ofthe walls complete including disposal of rubbish to the dumpingground within 50metres lead :With cement mortar 1:4 (1 cement : 4 fine sand) 19 Removing white or colour wash by scrapping and sand papering andpreparing the surface smooth including necessary repairs toscratches etc. complete 20 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade : Old work (one or more coats) 21 Kota stone slab flooring 25mm thick over 20 mm (average) thick Area of each slab 2001 to 5000 sqcm base laid over and jointed with grey cement slurry mixed withpigment to match the shade of the slab including rubbing andpolishing completewith base of cement mortar 1 : 4 (1 cement : 4coarse sand) : 22 Chequered precast cement concrete tiles 22 mm thick in footpath &courtyard jointed with neat cement slurry mixed with pigment tomatch the shade of tiles includingrubbing and cleaning etc.complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4coarse sand). Light shade using white cement. 23 Pre-laminated particle board with decorative lamination on bothsides. 24 Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with PVC/ neoprene gasket etc. completeas per the architectural drawings and the directions of engineer-in charge . (Cost of aluminium snap beading shall be paid in basicitem) :With floatglass panes of 5.50 mm thickness 25 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to thealuminium window by Aluminium beading 20x3mm with suitablescrews at not exceeding 150mm distance at all heights with all leadand lift with scaffolding. 26 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) 27 Providing and fixing 1st quality standard white, grey, ivory, fume redbrown, light green, light blue and other light shades glazed tilesconfirming to IS : 13753 & IS :15622 of size 200mm x 300mm inwalls, floors, steps, pillars etc. laid on a bed of neat cement slurryfinished with flush pointing in the white cement mixed with pigmentto match the shade of the tile complete (excluding the cost ofcement plaster on walls and pillar). 28 Providing and fixing 1st quality MAT finished ceramic tile size300x300mm confirmingto IS : 13755 and IS : 15622 colour such aswhite, grey, ivory, fume red brown, light green, light blue and otherlight shades in floors, steps, pillars etc. laid on a bed of neat cementslurryinished with flush pointing in the white cement mixed withpigment to match the shade of the tile complete (including the costof cement mortar bed 1:4). 29 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures completeincluding cutting and making good the walls and floors whereverrequired :White Vitreous china Orissa pattern W.C. pan of size 580x440mmwith integral type foot rests. 30 Providing and fixing white vitreous china pedestal type water closet european type) with seat and lid, 10 litre low level white vitreouschina flushing cistern & C.P. flush bend with fittings & C.I. brackets,40mm flush bend, overflow arrangement with specials of standardmake and mosquito proof coupling of approved municipal designcomplete including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. 31 Providing, lowering, laying in trenches, aligning, fixing in position andjointing socketed rubber gasket type ISI marked uPVC pipes ofClass III (6 Kg/sqcm) suitable for potable water with rubber ringjoints (as per IS 4985-2000) of following outer dia with allaccessories (excluding specials) complete including all material,labour, hydraulic testing and commissioning as per TechnicalSpecifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 110 mm dia 32 Providing and placing on terrace (at all floor levels) polyethylenewater storage tank ISI : 12701 marked with cover and suitablelocking arrangement and making necessary holes for inlet, outletand overflow pipes butwithout fittings and the base support for tank 33 Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing900/1400 RPM single phaseExhaustfanconforming to IS:2312 ISI marked in existing opening includingmaking connections testing etc. as required. All as per pre approvedby Engineer in-charge.For additional technical parameters ofproducts/ work, refer Annexure "A" attached with this BSR .380 mm sweep(900/1400 RPM) 34 Construction of brick masonry cylindrical road side inspectionchamber of 450mm dia (internal) with 230mm thick wall of brickmasonry (75 class designation brick) in cement mortar 1:4 (1 cement: 4 coarse sand), wall 230mm thick, filling of Jhiri, 20mm thick insideand outside plastering with CM (1:3), inside plaster finished withneat coat of cement, with cast in situ PCC M10 grade foundation of1010 mm dia and 100 mm thickness, 75mm thick PCC M15 flooring,precast SFRC/RCC circular 450mm dia MD manhole frame andcover (as per IS 12592 amended upto date) embedded in 200mmthick PCC M20 grade concrete, including providing and fixing 2 Nos110mm OD, 0.5m long PVC-U pipe pieces of stiffness class SN 8 asper IS 15328 and plugging the same, testing for water tightness etc.complete as per approved drawing and/or directed by Engineer.Note:Excavation of earth work and road cutting will be measuredand paid separately BM Road side inspection chamber of 600mm depth 35 Providing and fixing of 60mm thick precast cement concreteinterlocking paver block casted with rubber moulds in approvedreflective colour and design having minimum compressive strengthof 300 kg/ sq cm. The CC paving blocks be laid on average 50mmthick bed of coarse sand and the joint is to be filled with fine sand.Laying procedure on compacted sub-base as defined.Complete jobis to be executed as per the instruction of Engineer in-charge. Therates to be inclusive of all lead & Lifts etc. complete as perspecifications. 36 Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. 37 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm). 38 Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. 39 P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufacture) with water absorption less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grouting the joints with white cement and matching pigment etc complete. Size 600 mm X 600 mm 40 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure "A" attached with this BSR Short point (up to 3 mtr.) 41 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure "A" attached with this BSRMedium point (up to 6 mtr.) 42 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure "A" attached with this BSRLong point (up to 10 mtr..) 43 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure "A" attached with this BSR On board 44 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure "A" attached with this BSRShort point (up to 3 mtr.) 45 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure "A" attached with this BSRMedium point (up to 6 mtr.) 46 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure "A" attached with this BSR Long point (up to 10 mtr..) 47 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable sizeof modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter-56 related item & For additional technical parameters of product / work refer Annexure "A" attached with this BSR 48 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure "A" attached with this BSR 1 x 1.5 sq.mm 49 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure "A" attached with this BSR 1 x 2.5 sq.mm 50 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer incharge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 51 Double pole MCB(With B/C curve tripping Characteristics) 6 A to 32 A rating 52 Providing & Fixing of of 3/5 pin 6 amp. flush type non modular socket made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 53 Providing & Fixing of 3/6 pin 16 amp flush type non modular socket made out from Industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 54 Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 55 Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 56 Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure"A" attached with this BSR . With regulator 57 Providing & Fixing of BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondarysupport safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 1400 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 58 Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 59 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word+C29 Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer incharge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 60 Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set as per PWD specification for electrical Works, made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 61 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR Glazed door (single phase) IK-09 and IP-43 with Metal end box 4 Way (4+2)
|