Supply Services Of Removal Of Leaks In Pipelines Under The Water Supply Department In Financial Year 2025-26 For Municipal Council Tuljapur Tq Tuljapur Dist Dharashiv. , Excavation For Foundation / Pipe Trenches In Soft Rock And Old Cement And Lime Masonry Foundation Asphalt Road ?? Including Removing The Excavated Material Upto A Distance Of 50 M Beyond The Area And Lifts As Below, Stacking As Directed By Engineer-In-Charge, Normal Dewatering, Preparing The Bed For Foundation And Excluding Backfilling, Etc. Complete. (Bd-A 4/259) Lift 0 To 1.5 Mmjp Csr 23-24 Page No;- 37 It.No.05 Rate As Per M J Pc S Radd 2% For Municipal Area Lift??0??To , Excavation For Foundation / Pipe Trenches In Hard Murum Including Removing The Excavated Material Upto A Distance Of 50 M And Lifts As Below, Stacking And Spreading As Directed By Engineer-In-Charge, Normal Dewatering, Preparing The Bed For Foundation And Excluding Backfilling, Etc. Complete.??(Bd-A-2/259) Lift 0 To 1.5 Mmjp Csr 23-24 Page No;- 37 It.No.02 Rate As Per M J Pc S R Add 2% For Municipal Area , Providing And Supplying In Standard Lengthsh.D. Polyethelene Pipes, Confirming To Is 4984 /14151 / 12786 / 13488 With Nesessary Jointing Material Like Mechanical Connector I. E. Thread / Insert Joint / Quick Release Coupler Joint /Compression Fitting Joint Or Flanged Joint Excluding Coupler/ Specials, Including Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Conveyance To The Departmental Stores & Stacking The Same In Closed Shade Duly Protecting From Sunrays & Rains, Excluding Gst Levied By Gi & Gom In All Respect Etc. Complete.As Per Is:4984-2016(Hdpe Pipes Upto 110Mm Dia. Shall Be Pe-100 Mjp Csr 23-24 Page No;- 124, It.No.01 Pe -100 6Kg/Sq.Cm 75Mm Add 2% For Municipal Area , 90Mm , 110 Mm , 125Mm , 140Mm , 160Mm , 180Mm , 200Mm , 250Mm , Lowering, Laying And Jointing H. D. P. E./M. D. P. E. Pipes In Proper Position Including All Specials By Compression Fitting/Electrofusion And Butt Fusion Jointing Procedure As Per Relevant Is Code Complete With All Materials For Jointing Procedure Like Electrofusion Machine. Electric Heater/Butt Fusion Welding Machine With Hydraulic Jack, Top Loading Clamp Etc. And All Labors As Directed By Engineer In Charge As Per Is-7634 Part Ii Mjp Csr 23-24 Page No;- 125, It.No.02 Add 2% For Municipal Area , 75Mm , 90Mm , 110 Mm , 125Mm , 140Mm , 160Mm , 180Mm , 200Mm , 250Mm , Providing And Laying In Situ Following Grades Of Cement Concrete Of Trap / Granite Quartzite / Gneiss Metal` Including Dewatering. Form Work Compaction, Curing, Finishing Etc. Complete.Spec. No. - Bd E /I Page No. 287 And B-7, Page No. 38 Mjp Csr 23-24 Page No;- 47, It.No.01 B) M-150 Add 2% For Municipal Area , Providing Double Flange Sluice Valve Confirming For Is- 14846 Including Worn Gear Arrangements As Per Test Pressure , Stainless Steel Spindle, Caps, Including Inspection Charges, Transportation Up To Departmental Store, Unloading, Stacking Excluding Gst Levied By Goi & Gom In All Respect Etc. Complete. Mjp Csr 23-24 Page No;- 145, It.No.02 Sluice??Valves??-??Pn??-1??(Without??By??Pass) Add 2% For Municipal Area , 80Mm , 100 Mm , 125 Mm , 150 Mm , 200 Mm , 250 Mm , 300 Mm , Supply Of C. I. Mechanical Compression Flanged / Socket Tailpiece (Popularly Known As I Tm Flanged / Socket Tailpiece) Suitable For Making Flanged Connection With The Plain Barrel Of C. I. Spun Pipes ( As Per - Is - 1536 /2001) And D. I. Pipes ( As Per Is: 8329 / 2000).The Tailpiec To Be Supplied Complete With Sealing Rubber Gasket Of S.B.R, C.I. Follower??Glands And M.S. Nut Bolts.The Whole Assembly Should Be Mechanically And Hydraulically Tested To The Provisions As Laid Down In Is:1538 /1993. The Rates Are Inclusive Of Cost Of Material, Freight Charges, Loading, Transportation And Unloading At Departemental Store, Excluding Gst Levied By Gol And Gom??In??All??Respect,??Etc.??Complete??As??Directed. Mjp Csr 23-24 Page No -161 I No-1 Add 2% For Municipal Area , 80Mm , 100 Mm , 125 Mm , 150 Mm , 200 Mm , 250 Mm , 300 Mm , Supply Of Ci Mechanical Joint All Socket Tees As Dimensionally Described In Table -18 Of Is -13382/1992 Complete With Sealing Rubber Gasket Of S.B.R. (Dimensionally Described In Is- 12820/1989) With Cast Iron Follower Gland And Mild Steel Nut Bolts Coated Or Otherwise??Protected??From??Rusting??And??Suitable??For??C.??I.??Pipes.Mjp Csr 23-24 Page No -163 I No-7 Add 2% For Municipal Area , 80X80x80mm , 100Mmx10mmx80mm , 100Mmx100mmx100mm , 150Mmx150mmx80mm , 150Mmx150mmx100mm , 150Mmx150mmx150mm , 200Mmx200mmx80mm , 200Mmx200mmx100mm , 200Mmx200mmx150mm , 200Mmx200mmx200mm , 250Mmx250mmx80mm , 250Mmx250mmx100mm , 250Mmx250mmx150mm , 250Mmx250mmx200mm , Providing And Supplying D.I. Fittings With Isi Mark Mechanical Joint Confirming To Tables 12 To Table 31 Of Is 9523/2000 Upto Latest Amendments Including Cost Of Sbr/ Edpm Gaskets, Nuts, Bolts, Washers And Ductile Iron Follower Glands.Should Be With Internally Ordinary Portland Cement Mortor Lined And Externally Metallic Zinc Coating/Zinc Rich Paint With Finishing Layer Of Black Bitumen Coating Including Transportation And Excluding All Statutary Duties And Taxes Such As Gst Levied By Gol??And??Gom??In??All??Respect??Etc.??Complete.Mjp Csr 23-24 Page No -103 I No-1Add 2% For Municipal Area , 80Mm Dia , 100Mmm Dia , 150Mm Dia , 200Mm Dia , 250Mmdia , 300Mm Dia , 350Mm Dia , Refilling The Trenches With Available Excavated Stuff With Soft Material First Over Pipeline And Then Hard Material In 15 Cm Layers With All Leads And Lifts Including Consolidation, Surcharging, Etc. Complete.Mjp Csr 23-24Page No;- 40, It.No.15 Add 2% For Municipal Area , Providing, Double Flanged Short Body Patterntypemanually Operatedbutterfly Valvehavingbody,Discandendcoverin Graded Cast Iron To Is-210 Gr.Cf 200 Generallyconfirmingtois-13095-1991, Synthetic Rubber Faced Ring Secured On Disc By Retainingringwithstainlesssteelscrew Stub Shaft Of Stainless Steel Riding In Teflon Bearing Including Inspection Charges, Transportation Up Todepartmental Store, Unloading, Stacking Excludinggstleviedbygoi&Gominall Respectetc.Excludingc.C.Foundation /Structural Steel Support. Mjp Csr 23-24Page No;- 147, It.No.03 Butterflyvalve-Pn-1(Withbypass Arrangement) Add 2% For Municipal Area , 80Mm Dia , 100Mmm Dia , 125Mm Dia , 150Mm Dia , 200Mm Dia , 250Mmdia , 300Mm Dia , 350Mm Dia , 400Mm Dia , Lowering, Laying And Jointing In Position Followingc.I.D/Freflexvalves,Butterfly Valves And Sluice Valves Including Cost Of All Labour Jointing Material, Including Nut Bolts And Giving Satisfactory Hydraulic Testing Etc. Complete. (Rate For All Class Of Valves.) Mjp Csr 23-24Page No;- 147, It.No.04Add 2% For Municipal Area , 80Mm Dia , 100Mmm Dia , 125Mm Dia , 150Mm Dia , 200Mm Dia , 250Mmdia , 300Mm Dia , 350Mm Dia , 400Mm Dia , Providingd.I.Pipes(Pushonjointspressure Pipesofd.I.Offollowingclassanddiameters Confirming To The I. S. Specification Inclusive Cost Ofjointingmaterials(Rubbergasketofepdm Quality ) Excluding Gst Levied By Goi & Gom In All Respect Including Third Party Inspection Charges Of Tpi Agency Approved By Mjp Including Transit Insurance, Railwayfreight, Unloading Fromrailway Wagon, Loading Into Truck, Transportation To Departmental Store, Unloading, Stacking Etc. Completed As Directed By Engineer In Charges (Is 1536/2001 For Pipes And Is158/1969Andis12820/1989Orlatestedi- Tion/Revision Withamendmentsforrubber Gaskets. Mjp Csr 23-24Page No;- 69, It.No.03 (Is:8329-2000 Latest Version) D.I. K-7 , 100Mm , 150Mm , 200Mm , 250Mm , 300Mm , 350 Mm , 400 Mm , 450 Mm , Valve Chamber With Precast Rcc Covers Providing And Constructing B.B. Masonry Valve Chamber With 15 Cm Thick 1:2:4 Proportion Pcc Bedding, Excluding Excavation, B.B. Masonry In Cm 1:5 Proportion Precast Rcc Frame And Cover, Etc. Complete As Directed By Engineer-Incharge.. As Above Of 60 X 45 Cm Internal Size And Depth Upto 0.9 M With Precast R.C.C. Slab Cover. Mjp Csr 21/22 Page No;- 285, It.No.01 Add 2% For Municipal Area , Supply Ofc.I.Mechanicalcompressioncollarcoupling Suitable For C. I. Spun Pipes ( As Per - Is - 1536 /2001) And Complete With Sealing Rubber Gasket Of Sbr,.C.I. Follower Glands And M.S. Nut Bolts.The Whole Assembly Should Be Mechanically And Hydraulically Tested To The Provisions As Laid Down In Is:1538 /1993. , 80Mm Dia , 100Mmm Dia , 125Mm Dia , 150Mm Dia , 200Mm Dia , 250Mmdia , 300Mm Dia , 350Mm Dia , 400Mm Dia , 450Mm Dia , Note:- Rate Should Be Quoted With Inclusive Ofall Taxes And Frieght Charges For All Items. If The Rate Is Not Quoted For Any Oneof The Item Then The Bid Will Rejected.
|