Medical Equipments, Pharmaceuticals And Personal Care Products – Procurement Of Medical Aids, Medical Consumables For Interventional Cardiology - Stents And Distal Protection. Coronary Stent With A Sinusoidal Configuration And Permanent Polymer Coated With A Cytostatic From The Limus Family (Des), The Stent Has A Platinum-Iridium Core For Enhanced Visualization With An Outer Coating Of Cobalt-Chromium, Platinum-Iridium Markers, With A Minimum Stent Diameter Range Of 2.25Mm - 4.0Mm And A Minimum Length Range Of 8Mm - 38Mm,Coronary Stent With A Permanent Polymer Coated With A Cytostatic From The Limus Family (Des), The Stent Has A Platinum-Iridium Core For Enhanced Visualization With An Outer Coating Of Cobalt-Chromium, Platinum-Iridium Markers, With A Minimum Stent Diameter Range Of 2.0-5.00Mm With The Possibility Of Over-Expansion Up To 6.00Mm (For Diameters 4.5-5.0Mm), And A Minimum Length Range Of 8Mm-38Mm.,Coronary Stent Made Of Platinum Chromium Alloy, Nonlinear Link Design With Open Cells, Coated With A Permanent Polymer And The Cytostatic Everolimus (Des), Diameter Range From 2.25 To 4Mm And Length From 8Mm To At Least 38Mm, Compatible With A 5F Guiding Catheter For All Sizes,Coronary Stent Made Of Platinum Chromium Alloy, Thin Profile, Nonlinear Link Design With Open Cells, Abluminally Coated With A Bioresorbable Polymer And The Cytostatic Everolimus (Des), Diameter Range From 2.25 To 5 Mm And Length From 8 To 48Mm, Compatible With A 5F Guiding Catheter For All Sizes,Self-Expanding Cobalt-Chromium Stent For Carotid Arteries - 0.014” Guidewire, Compatible With 5F Introducer Sheath, Straight I Tapered-Closed Cell Design, Diameter Range From 6-10Mm And Length Range From 30-50Mm.,Coronary Stent Made Of Cobalt-Chromium Alloy, Open Cell Design With A Biodegradable Polymer, Coated With The Immunosuppressive Drug Sirolimus, Strut Thickness Of 60 Μm With Probio Coating (Amorphous Silicon-Carbide), Diameter Range From 2.25 - 4Mm And Length Range From 9 - 40Mm. Must Have Ce Certification For Patients At High Risk Of Bleeding.,Peripheral Balloon-Expandable Stent, Made Of Cobalt-Chromium, Otw System, Compatible With 6 Fr Introducer, Strut Thickness Of 110 Micrometers (For Stents With 5-7 Mm Diameter), With Probio Coating, With 2 Markers, On Catheter Carrier 90, 135, And 170 Cm, And Stent Length From 18-78 Mm, Diameter Range From 5-10 Mm.,Coronary Stent Made Of Cobalt-Chromium Alloy, Nonlinear Multi-Link Cell Design, Coated With A Permanent Polymer And The Cytostatic Drug Everolimus (Des), Minimum Diameter Range From 2 To 4 Mm And Length From 8 To At Least 38 Mm, Compatible With A 5F Guiding Catheter For All Sizes.,Coronary Stent Made Of Cobalt-Chromium Alloy, Multi-Link - Nonlinear Link Design For Large Diameter Coronary Arteries, Coated With A Permanent Polymer And The Cytostatic Drug Everolimus (Des), Low Stent Crossing Profile ≤ 0.039 (For A 3Mm Diameter Stent), Diameter Range From 2.25 To 4Mm And Length From 8 To 38Mm, With The Ability For Expansion Up To 5.5Mm For Diameters 3.5 And 4.0Mm Without Shor,Peripheral Nitinol Stent System, Self-Expanding, With A Woven Mesh Design, Flexible And Resistant To Collapse, Intended For Interventions In The Femoral And Popliteal Arteries, With A Diameter Range From 4.5 To 7.5 Mm And Stent Length From 20 To 200 Mm, Compatible With A 6F Introducer.,Self-Expanding Carotid Stent System Made Of Nitinol Alloy With A Closed-Cell Design, Rx System, With A Straight Or Tapered Diameter Range From 6.0 To 10.0Mm And Lengths From 20 To 40Mm, Compatible With A 6 French Guiding Introducer.,D
|