Supply Of Cath Lab Consumables For The Period From 01.04.2025 To 31.03.2026-1 DES, EVEROLIMUS,FDA APPROVED PLATINUM CHROMIUM PLATFORM 2 DES, EVEROLIMUS,FDA APPROVED PLATINUM CHROMIUM PLATFORM POLY-VINYLIDENE FLUORIDE-HEXAFLUOROPROPYLENE ( PVDF-HFP)POLYMER 3 DES, EVEROLIMUS, FDA APPROVED PLATINUM CHROMIUM PLATFORM, BIOABSORBABLE POLYMER PLGA 4 DES, EVEROLIMUS, FDA APPROVED COBALT CHROMIUM PLATFORM Stent length up 12 mmto 38mm 5 DES, EVEROLIMUS HYPOTUBE BALLOON TECHNOLOGY, FDA APPROVED COBALT CHROMIUM PLATFORM Stent length up to 48mm 6 DES, EVEROLIMUS, FDA APPROVED CTO STENT COBALT CHROMIUM PLATFORM, FLUOROPOLYMER ,2.25MM-4.25MM DIAMETER 7 DES, EVEROLIMUS, ONLY DCGI COBALT CHROMIUM PLATFORM, 50 MICRON STRUT THICKNESS 8 DES, EVEROLIMUS, ONLY DCGI COBALT CHROMIUM PLATFORM with 55 micron strut 9 DES, EVEROLIMUS, ONLY DCGI COBALT CHROMIUM PLATFORM 10 DES, BIOLIMUS, FDA APPROVEDCOBALT CHROMIUM PLATFORM 11 DES, BIOLIMUS, CE APPROVEDCOBALT CHROMIUM PLATFORM 12 DES, BIOLIMUS, ONLY DCGI APPROVED COBALT CHROMIUM PLATFORM,50 micron strut 13 DES, ZOTAROLIMUS, FDA APPROVED COBALT CHROMIUM PLATFORM ,POLYMER TYPE -BIOLINX 14 DES, ZOTAROLIMUS, CE APPROVED COBALT CHROMIUM PLATFORM POLYMER TYPE -PHOSPHORYLCHOLINE 15 DES, ZOTAROLIMUS, ONLY DCGI COBALT CHROMIUM PLATFORM HYDROPHILIC POLYMER 16 DES, ZOTAROLIMUS ELUTING CORONARY STENT SYSTEM WITH CORE WIRE AND CONTINUOUS SINSOID TECHNOLOGY, COBALT ALLOY, PLATINUM IRIDIUM CORE, 17 DES, SIROLIMUS, CE APPROVEDCOBALT CHROMIUM PLATFORM 18 DES, SIROLIMUS, ONLY DCGI APPROVED COBALT CHROMIUM PLATFORM 45 micron 19 DES, SIROLIMUS, FDA APPROVED STAINLESS STEEL PLATFORM 20 DES, SIROLIMUS, CE APPROVED STAINLESS STEEL PLATFORM 21 DES, SIROLIMUS, ONLY DCGI APPROVED STAINLESS STEEL PLATFORM 50 micron strut thicknes 22 DES, DUAL DRUG ELUTING DUAL DRUG ELUTING POLYMER FREE STENT 23 BMS, FDA APPROVED COBALT CHROMIUM PLATFORM 24 BMS, CE APPROVED COBALT CHROMIUM PLATFORM 25 BMS, ONLY DCGI APPROVED COBALT CHROMIUM PLATFORM 26 Bifurcation stent Self expanding, Nitinol 27 Bifurcation stent Balloon expandable, Platinum Chromium 28 Bifurcation stent Sirolimus Eluting, Cobalt chromium 29 Bifurcation stent Paclitaxel Eluting, Cobalt chromium 30 Tapered stent 31 serolimus eluting stent with 65 micron strunt thickness with hybrid design with proximal main branch segment and distal taperd side branch segment 32 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM, (Any diameter / any length) 33 Sirolimus Eluting Coronary Stent System with an ultra-thin 65 μm strut thickness , Delivery System with Monolithic Design. Monolithic Distal Shaft Design has the best-in-class acute performance, pushability and trackability,Elongated distal tip of 7.5mm ensures lower entry profile and high success for device crossing in complex anatomies. with optimal side branch support. SIZE: 2,2.25,2.5,2.75,3,3.5,4,4. Diamter:8,13,16,19,24,29,32,37,40,44,48 34 Coronary Self Apposing stent 35 Multilink cobalt chromium 36 Meshed stent 37 PTFE covered stent Stainless steel, Rapid exchange type, Sizes 2.8, 3.5, 4, 4.5, 4.8mm, usable length 143cm, crimped stent profile 0.068inch 38 Biodegradable vascular scaffold (BVS) Everolimus eluting 39 Biodegradable vascular scaffold (BVS) Sirolimus eluting 40 Stainless Steel Abluminally coated Sirolimus Eluting Coronary Stent with microporous surface & low biodegradable polymer with temperature controlled packing and temperature monitoring device--CE Approved 41 Polymer free Dual Drug sirolimus and Probucol eluting Stent technology with Microporous surface Abluminal coating and Shellac resin with diameters 2mm-4mm and length 8mm-48mm- DCGI Approve 42 Cobalt Chromium Abluminally coated Sirolimus Eluting Coronary Stent with microporous surface & low biodegradable polymer –CE Approved 43 Stainless Steel Abluminally coated Sirolimus Eluting Coronary Stent with microporous surface & low biodegradable polymer --CE Approved 44 DES, SIROLIMUS, CE APPROVED STAINLESS STEEL PLATFORM, PBMA / PEVA double layer polymer coating for optimal drug release control. Flexible stent design.90 days drug releasing.Largeopencells for side branch access 45 DES, EVEROLIMUS, CE/FDA/DCGI APPROVED COBALT CHROMIUM PLATFORM VARIOUS SIZE AND LENGTH, BIODEGRADABLE POLYMER STRUT THICKNESS 56-60MICRONS with cumilative drug realese technology diameters:8,12,16,20,24,28,32,36,40,44,48, length: 2,2.25,2.5,2.75,3,3.5,4,4.5 ,,del system 140 cm 46 DES, SIROLIMUS CE/ FDA/ DCGI APPROVED COBALT CHROMIUM PLATFORM SIZE AND LENGTH, BIODEGRADABLE POLYMER STRUT THICKNESS 56-60 MICRONS diameters:8,12,16,20,24,28,32,36, 40,44,48, length: 2,2.25,2.5,2.75,3,3.5,4,4.5 ,,del system 140 cm with laser cut technology seamless tubing in a serpentine patern 47 DES, SIROLIMUS CE/ FDA/ DCGI APPROVED COBALT CHROMIUM PLATFORM SIZE AND LENGTH, BIODEGRADABLE POLYMER STRUT THICKNESS 56-60MICRONSwith cumilative drug realese technology diameters:8,12,16,20,24,28,32,36,40,44,48, length: 2,2.25,2.5,2.75,3,3.5,4,4.5 ,,del system 140 cm with laser cut technology seamless tubing in a serpentine patern 48 DES, SIROLIMUS CE/ FDA/ DCGI APPROVED COBALT CHROMIUM PLATFORM SIZE AND LENGTH, BIODEGRADABLE POLYMER STRUT THICKNESS 56-60MICRONS with S-link technology for trackability diameters:8,12,16,20,24,28,32,36,40,44,48, length: 2,2.25,2.5,2.75,3,3.5,4,4.5 ,,del system 140 cm with laser cut technology seamless tubing in a serpentine patern 49 DUAL DRUG SIROLIMUS COATED STENT Unique fusion coating both stent and balloon is drug coated. ( thus faster re endothelializaton) Edge coating : 0.5mm of proximal and distal ends of balloon is also coated Sizes : 2.25-4mm Lennth: 8-40mm 50 SIROLIMUS ELUTING CORONARY STENT SYSTEM, Drug-Sirolimus Polymer -Biodegradable and Biocompatible Stent Diameter 2.25(mm) Stent Lenth 8 to 48 (mm) available 51 EVEROLIMUS ELUTING CORONARY STENT SYSTEM, Drug -Everolimus,Polymer -Biodegradable and Biocompatible Stent Diameter 2.25(mm) Stent Lenth 8 to 48 (mm) available 52 DCGI Approved DES, Everolimus stent systum with cobalt cromium 65 micron strut thickness size: 2.25,2.5,2.75,3,3.5,4,4.5 length: 8 to 47 mm 53 DES serolimus eluting cobalt cromium stent system strut thickness of 0.07mm with a hybrid design of closed and open cells with unique hypotube for pushability .size:2.5,2.75,3,3.25,4, length:8,13,18,23,28,33,38 54 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 5 mm 55 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 4.5 mm 56 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 4 mm 57 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 3.5 mm 58 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 3.25mm 59 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 3mm 60 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 2.75mm 61 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 2.5 mm 62 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 2 .25mm 63 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM Diameter 2 mm 64 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM, Short stent, Length 8mm 65 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM, Intermediate Length, upto 48 mm 66 DES, SIROLIMUS, COBALT CHROMIUM PLATFORM, Long stent with Length more than 48 mm 67 DES, sirolimus 3.9nano gram/stent length, cobalt chromiumL605 stent with 80 micron strent thickness with open cell structur for side branch re crossing 68 DES, sirolimus 3.9nano gram/stent length, cobalt chromiumL605 stent with 80 micron strent thickness with open cell structur for side branch re crossing ,coating albuminal and gradient ,hydro philic distal shaft coating 69 DES , EVOROLIMUS L 605 COBALT CHROMIUM, BIODEGRADABLE DCGI APPROVED STENT WITH OPEN AND CLOSED STENT DESIGN ,65 MICRONS THICKNESS , HYDROPHILIC COATED DELIVERY SYSTEM , COATING THICKNESS 60MICRONS, SIZE 2.25 -4 mm diameter ,length -10 ,13,15,18,20,24,28,32,36,40,42, 44 mm 70 DES, SIROLIMUS L 605 COBALT CHROMIUM, BIODEGRADABLE DCGI APPROVED STENT WITH OPEN AND CLOSED STENT DESIGN ,65 MICRONS THICKNESS , HYDROPHILIC COATED DELIVERY SYSTEM , COATING THICKNESS 60MICRONS, SIZE 2.25 -4 mm diameter ,length -10 ,13,15,18,20,24,28,32,36,40mm 71 Covered stent 72 Semi compliant balloon Baloon size: 1.2mm– 5 mm / Length: 6 mm -42 mm,(FDA/CE APPROVED) 73 OTW Compliant Balloon Balloon size: 1.2mm – 5 mm / Length: 6 mm -30mm,(FDA/CE APPROVED) 74 1.25-2.5mm Semicompliant OTW Balloon for CART technique Balloon Length: 10-20 mm / Shaft Length: 135,148cm, entry profile - 0.43 mm (FDA/CE APPROVED) 75 Rapid Exchange Noncompliant Balloon Balloon size: 1.2mm– 5 mm / Length: 6 mm -42 mm (FDA/CE APPROVED) 76 Rapid Exchange Semicompliant Balloon Balloon size: 1.2mm – 5 mm / Length: 6 mm -42 mm (FDA/CE APPROVED) 77 OTW Noncompliant Balloon Balloon size: 1.2mm – 5 mm / Length: 6 mm -30 mm (FDA/CE APPROVED) 78 OTW Semicompliant Balloon Balloon size: 1.2mm – 5 mm / Length: 6 mm -30 mm (FDA/CE APPROVED) 79 1.25-2.5mm Semicompliant CTO Balloon Balloon Length: 10-20 mm / Shaft Length: 148cm,(FDA/CE APPROVED) 80 1.25-2.5mm Non-compliant CTO Balloon Balloon Length: 10-20 mm / Shaft Length: 148cm,(FDA/CE APPROVED) 81 US FDA Approved Rapid exchange 1.2-2 mm Semicompliant CTO Balloon ,Balloon Length:6-30mm / Shaft Length: 145cm,(FDA/CE APPROVED) 82 Rapid Exchange Compliant/ Noncompliant balloon, Balloon diameters-4-6mm, lengths-15,20mm, Catheter length-150cm, nominal pressure-6atm (FDA/CE APPROVED) 83 Rapid Exchange Compliant/ Noncompliant balloon, Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-142cm, nominal pressure-6-14atm(FDA/CE APPROVED) 84 Monorail Compliant/ Noncompliant balloon,Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-140/135cm, nominal pressure-6atm (FDA/CE APPROVED) 85 OTW Compliant/ Noncompliant balloon ,Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-140/135cm, nominal pressure-6atm (FDA/CE APPROVED) 86 Monorail compliant/Noncompliant balloon,Balloon diameters-2- 6mm, Lengths- 6- 30mm, catheter length- 143cm, nominal pressure-12atm(FDA/CE APPROVED) 87 OTW compliant/Noncompliant balloon,Balloon diameters-2- 6mm, Lengths- 6- 30mm, catheter length- 142cm, nominal pressure-12atm (FDA/CE APPROVED) 88 NC balloon twin layered for very high pressure dilatation,Balloon diameters-2- 6mm, Lengths- 6- 30mm, catheter length- 142cm(FDA/CE APPROVED) 89 Semicompliant/ Noncompliant balloon with tip entry profile 0.019”,Balloon lengths-8-38mm, balloon diameters-2-4.5mm, 0.014” compatible(FDA/CE APPROVED) 90 US-FDA approved for CTO indication, Semi &Non compliant Balloon dilatation catheter ,Balloon lengths-8-38mm, balloon diameters-2-4.5mm, 0.014” compatible (FDA/CE APPROVED) 91 US-FDA approved for CTO indication, Semi &Non compliant Balloon dilatation catheter ,avrage burst pressur of 18 atmosphere and 143cm length (FDA/CE APPROVED) 92 US-FDA approved for CTO indication, Semi &Non compliant Balloon dilatation catheter ,size:1.5,2,2.5mm, length:6,8,12,15(FDA/CE APPROVED) 93 FDA Approved Semi compliant Balloon dilatation catheter with Crossflex Technology, Laser Bond technology,size: 1.2,1.5,2,2.5MM, LENGTH :6,8,12,15 (FDA/CE APPROVED) 94 FDA Approved Non compliant Balloon dilatation catheter with Crossflex Technology, Laser Bond technology, size;2,2.5,2.75,3,3.5,4,4.5mm,length;6,8,12,15MM(FDA/CE APPROVED) 95 Rapid Exchange Semicompliant Nylon Semi-compliant balloon with 0.017 " tip entry profile, 135 mm effective length | Balloon size: 1.5mm – 4 mm / Length: 9 mm -30 mm (FDA/CE APPROVED) 96 Rapid Exchange Pebax Noncompliant balloon Balloon with patented Hydrophilic coating on distal shaft with 0.017" tip entry profile ,Balloon diameters 2.25 - 4.0 mm , lengths 6.0 - 30 mm, effective Catheter length-142cm, nominal pressure-6atm (FDA/CE APPROVED) 97 Rapid Exchange Semicompliant CTO balloon with 0.016 " tip entry profile, Average burst pressure of 24 atmospheres and 140 mm length with Slider Hydro coating | Balloon size: 1.0mm – 4 mm / Length: 5 mm -30 mm (FDA/CE APPROVED) 98 Rapid Exchange Pebax Noncompliant balloon Balloon with patented Slider Hydroo coating with 0.017" tip entry profile and Rated burst pressure of 22 atm. and mean burst pressure of 30 atm. | Balloon diameters 2.0 - 5.0 mm , lengths 8.0 - 18mm, effective working length length-140cm.(FDA/CE APPROVED) 99 Sirolimus eluting balloon nanolutepropritorynano carrier drug eluting tecnology drug:1.27μ/mm2of sirolimus Drun release within 60 secs.14 to 28 days drun bio availability in target tissue ,size: 2mm -4mm length:40mm to 100mm (FDA/CE APPROVED) 100 POST DILATATION CATHETER, Proximal Shaft -1.95F,Distal Shaft -2.7F,Usable Length -140 cm (FDA/CE APPROVED) 101 PTCA PRE-DILATATION CATHETER,Proximal Shaft -1.8F, DistalShaft -2.7F ,Usable Length -140 cm (FDA/CE APPROVED) 102 semi compliant XD shaft ,Hydro X coating Z tip from 1mm to 4mm size :1,1.25,1.5,2,2.25,2.5,2.75,3,3.25,3.5,4, length:8,10,12,15,20 (FDA/CE APPROVED) 103 Non Compliant PTCA Balloon catheter with crossing profile of 0.0360.NP is 12,RBP 20 atm Hydro X(distal tip to guide wire exit port) invio coating (guide wire lumen) size:1.75,2,2.25,2.5,2.75,3,3.25,3.5,3.75,4,4.5,5 ,length: 8,10,12,15,18 (FDA/CE APPROVED) 104 ultra low profile CTO balloon with 0.016 tip entry profile/flexible tip,specially tri wrapped balloon providing superior rewrapping which givese enhanced re-crossability.thin proximal shaft of 1.9 f nominal of 6 atm and RBP Of 14 atm. 1.25 to 3mm diameter ballon(FDA/CE Approved) 105 FDA/CE approved ,Non compiantptca balloon catheter with hydrophilic coating shaft length is 145cm,shaft diameter :2f (0.67) proximal ,distal:2.5f (0.83),distal for 2.25mm to 3mm2.6 fr (0.87mm) distal for 3.25mm to 5 mm with double ballon marker ,RBP;20 atm for 2.25mm to 4mm,18atm for 4.5 to 5mm with entry profile 0.43mm 106 (FDA/CE Approved)non compliant hydrophilic coated balloon with flexible thin markers,tri layer balloons with soft inner and outer elastomer layers that for resistance from high pressures and stronger polymide layer in the middle for aditional and safer high pressurressistance., shaft diameter of 1.9f proximal and 2.5f in the mid segment 145 cm length with nominal pressure of 12 atm and RBP 22 atm ,lesion entry profile 0.017 107 Semicompliantballoon,Balloon size: 1.5mm– 2.5 mm / Length: 8 mm -20 mm rapid exchange proimal shaft 0.72mm and distal shaft -0.90mm, TIP profile -0.018 with Nomial inflation pressure 8 atm&RBP -16 ATM , and having two plantinumiridum markers (DCGI APPROVED) 108 Semicompliantballoon,Balloon size: 1.2mm– 5 mm / Length: 6 mm -42 mm (DCGI APPROVED) 109 OTW Compliant Balloon,Balloon size: 1.2mm – 5 mm / Length: 6 mm -30mm (DCGI APPROVED) 110 1.25-2.5mm Semicompliant OTW Balloon for CART technique,Balloon Length: 10-20 mm / Shaft Length: 135,148cm, entry profile - 0.43 mm (DCGI APPROVED) 111 Rapid Exchange Noncompliant Balloon,Balloon size: 1.2mm– 5 mm / Length: 6 mm -42 mm (DCGI APPROVED) 112 Rapid Exchange SemicompliantBalloon,Balloon size: 1.2mm – 5 mm / Length: 6 mm -42 mm(DCGI APPROVED) 113 OTW Noncompliant Balloon,Balloon size: 1.2mm – 5 mm / Length: 6 mm -30 mm(DCGI APPROVED) 114 OTW SemicompliantBalloon,Balloon size: 1.2mm – 5 mm / Length: 6 mm -30 mm(DCGI APPROVED) 115 1.25-2.5mm Semicompliant CTO Balloon,Balloon Length: 10-20 mm / Shaft Length: 148cm(DCGI APPROVED) 116 1.25-2.5mm Non-compliant CTO Balloon,Balloon Length: 10-20 mm / Shaft Length: 148cm(DCGI APPROVED) 117 US FDA Approved Rapid exchange1.2-2 mm Semicompliant CTO Balloon,Balloon Length:6-30mm / Shaft Length: 145cm(DCGI APPROVED) 118 Rapid Exchange Compliant/ Noncompliant balloon,Balloon diameters-4-6mm, lengths-15,20mm, Catheter length-150cm, nominal pressure-6atm (DCGI APPROVED) 119 Rapid Exchange Compliant/ Noncompliant balloon,Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-142cm, nominal pressure-6-14atm(DCGI APPROVED) 120 Monorail Compliant/ Noncompliant balloon,Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-140/135cm, nominal pressure-6atm(DCGI APPROVED) 121 OTW Compliant/ Noncompliant balloon,Balloon diameters-1.5- 4mm, lengths- 9- 30mm, catheter length-140/135cm, nominal pressure-6atm(DCGI APPROVED) 122 Monorail compliant/Noncompliant balloon,Balloon diameters-2- 6mm, Lengths- 6- 30mm, catheter length- 143cm, nominal pressure-12atm(DCGI APPROVED) 123 OTW compliant/Noncompliant balloon,Balloon diameters-2- 6mm, Lengths- 6- 30mm, catheter length- 142cm, nominal pressure-12atm(DCGI APPROVED) 124 Semicompliant/ Noncompliant balloon with tip entry profile 0.019”,Balloon lengths-8-38mm, balloon diameters-2-4.5mm, 0.014” compatible(DCGI APPROVED) 125 Non Compliant PTCA Balloon catheter with hydrophilic coating ,0.16'' Lesion Entry profile and 24 Bar RBP(DCGI APPROVED) 126 Semi Complaint PTCA Balloon ,Catheter with hydrophilic Coating on balloon and distal shaft including sleeve and transition tube with comparable lesion entry profile(DCGI APPROVED) 127 Twin layered super high pressure balloon dilated catheter for highly calcified lesion,35 bar RBP,45 bar ABP-CE marked(DCGI APPROVED) 128 Semicompliantballoon,Balloon size: 1.5mm– 2.5 mm / Length: 8 mm -20 mm rapid exchange proimal shaft 0.72mm and distal shaft -0.90mm, TIP profile -0.018 with Nomial inflation pressure 12 atm&RBP -22 ATM , and having two plantinumiridum markers (DCGI APPROVED) 129 Rapid Exchange Noncompliant Balloon ,size: 1.0mm– 5 mm/ Length: 6 mm -42 mm catheter length = 135-140 cm nominal pressure - 12atm (DCGI APPROVED) 130 OTW Semicompliant Balloon ,Balloon size: 1.2mm – 5 mm / Length: 6 mm -30 mm(DCGI APPROVED) 131 PTCA-rapid exchange semi compliant pre-dilation catherer,entry profile0.017,crossing profile 0.026,shaft length 2.2Fr skived over extruded hypotube distal 2.4 fr, size:1.5,2,lengt: 10,15,20,30(DCGI APPROVED) 132 semi compliant pre-dilation catherer, balloon material nylon 12,entry profile0.017,crossing profile 0.026,shaft length 2.2Fr skived over extruded hypotube distal 2.4 fr, size:2.52.75,3,3.25,3.5,3.75,4lengt: 10,15,20,3032(DCGI APPROVED) 133 Low profile OTW Peripheral Vascular Dilatation Balloons : Low profile over the wire peripheral vascular dilatation balloons, end hole 018”, shaft length 40, 80, 90, 135, 150 cms, balloon diameters 2.5 mm to 10mm, balloon lengths 1cm to 22 cm, Upto 8*4 - 4 fr sheath capable, Upto 10*4 - 5Fr sheath capable, Upto 10*8 - 6Fr sheath capable. 134 PTCA-rapid exchange non compliant post-dilation catherer,entry profile0.017,crossing profile 0.032, proximal shaft 2.2fr, over spvhypotube distal 2.6 fr, size:1.5,2,2.5,2.75,3,3.25,3.5,3.75,4mmlengt: 10,15,20,30mm(DCGI APPROVED) 135 Platinum - Iridium Stents for large Vessels - Covered and Uncovered - Special Order - For use in large vessels for which suitable stents are available only on pre order/ special order 136 135 cm Thrombus Aspiration Catheter,Outer diameter: 3.9-5.4F 137 140 cm Thrombus Aspiration Catheter,Outer diameter: 3.9F 138 145 cm Thrombus Aspiration Catheter,Outer diameter: 3.5 F 139 Thrombus Aspiration Catheter with hydrophilic coating,Sizes – 6-8F, length-140cm, internal diameter – 0.070” – 0.86” 140 Thrombus Aspiration Catheter with braided technology,Catheter length 145cm, maximum tip diameter - 1.73, 1.98, Guide catheter - 6, 7F 141 Low profile thrombus aspiration catheter,Maximum tip diameter - 1.40, length 145 cm 142 Thrombus aspiration catheter with tapered silva tip with sloped extraction lumen,0.014”, length-140cm, rapid exchange length-20cm 143 Thrombin and collagen based flowable hemostat for pacemaker pocket hemostasis.Thrombin vial , Collagen syringe with attached mixing luer, Diluent vial, Mixing accessories, Applicator tips 144 Monofilament suture type vascular closure device,puncture size – 8F-21F 145 Braided suture type vascular closure device,puncture size – 5F- 8F 146 Mechanical seal type vascular closure device,Puncture size- 5/6, 7/8 147 Balloon type radial artery compression device,Transparent dual compression balloons, with Velcro straps, sizes 24-29cm 148 Dial type radial artery compression device, 149 Brachial/radial artery compression device with plastic strap,Adjustable plastic strap, Sizes 21-37cm 150 Pressure-assisted radial artery compression device, Inflatable bulb type 151 Pressure-assisted femoral artery compression device,Inflatable bulb type, sizes 12,24cm 152 Drug eluting balloon.Balloon size: 1.5mm – 6 mm / Length: 10 mm -250mm 153 Cutting balloon.Balloon size: 2mm – 4 mm / Length: 6 mm, 10mm, 15mm 154 2.8 F proximal size microcatheter for retrograde approach,Stainless coil shaft with 10 braided wire, Distal size: 1.26 F / 150 cm Length 155 2.1F proximal size specialty micro catheter,long taper with platinum tip and stainless steel rope,Distal size: 1.8F / 135 cm Length 156 2.6 F proximal size specially micro catheter,ong taper with platinum tip and stainless steel rope, Distal size: 2.1 f / 135 cm Length. 157 2.9 F proximal size ordinary micro catheter,Distal size: 2.2 – 2.4 f / 150 cm Length. 158 130 & 150 cm stainless steel braide , hydrophilic coating , tapered inner shaft with floppy distal 13 cm segment, proximal size 2.6 F , distal size 1.8 F , radio opaque tip 159 micro catheter: hydrophilic coated shaft length 135cm,shaft outer diameter :distal-1.9fr,proximal:2.6fr.shaft inner diameter -distal:0.017fr,proximal:0.022fr 160 2.7 f proximal size micro cathetre with 021 hydrophilic coating wire, tungsten coil pitch, distal 2.9 f,,length 130 cm 161 Microcatheter for delivery of micro coils,Vortec fiber braided microcatheter, length 130 and 150 cm, proximal size 3Fr, Distal size 2.5 Fr, end hole diameter 0.021 inch, with radio opal tip and hydrophilic coating 162 Microcatheter for delivery of micro coils, capable of injection , Vortec fiber and platinum braided microcatheter, length 105 to 150 cm, proximal size 3Fr, Distal size 2.8 Fr, end hole diameter 0.027 inch, with radio opal tip and hydrophilic coating 163 Diagnostic guidewire - exchange length PTFE Coated , Straight and J tipped : Diagnostic guidewire - Single length PTFE Coated , Straight and J tipped - 018, 021, 025 inches 260cm 164 Diagnostic guidewire - Single length PTFE Coated , Straight and J tipped : Diagnostic guidewire - Single length PTFE Coated , Straight and J tipped - 018, 021, 025 inches 150cm 165 185 cm long Floppy work horse wire for PTCA-Straight / J tip -Core material stainless stee 166 185 cm long Intermediate work horse wire for PTCA-Straight / J tip -Core material stainless steel 167 185 cm long Extrasupport work horse wire for PTCA-Straight / J tip -Core material stainless steel 168 182 cm ,300 cm , spring coil , core to tip design, 0.014 with 0.8 tip load , PTCA work horse wire-Straight / J tip 169 190 cm ,0.014 , hydrophilic distal 30 cm & PTFE proximal shaftlong PTCA work horse wire-Straight / J tip -Core material stainless steel 170 180 cm long, 0.8 tip load , 30 mm silicone coating from tip, Straight / J tip -Core material stainless steel 171 190 cm long, 0.8 Tip load , 12 cm spring coil length , stainless steel high tension core -Straight / J tip 172 180 cm long, 0.5 Tip load PTCA work horse wire -Straight / J tip 173 180 cm long, core to tip design , 0.014, 0.7 tip load, hydrophobic , extra support wire,Straight / J tip 174 US FDA approved 190 , 300 cm length, nitinol core, PTCA work horse wirewith polymer sleeve with soft tip load of <1gm & shaping ribbon design .7g tip load Straight / J tip 175 US FDA approved 190 , 300 cm length, nitinol core, PTCA work horse wirewith polymer sleeve ,with soft tip load of <1gm & shaping ribbon design .7g tip load Straight / J tip 176 US FDA approved190 , 300 cm length, hydrophobic coating type nitinol core, PTCA work horse wire ,with polymer sleeve ,with soft tip load of <1gm & shaping ribbon design .7g tip load Straight / J tip 177 US FDA Approved 190 cm long, tip load-0.8Floppy work horse wire for PTCA ,Straight / J tip, Core material stainless steel , polymer tip , core to tip design , 0.014 with 0.8 tip load , with hydrophilic tip and light support 178 US FDA approved 190 cm long, tip load- 1 intermediate work horse wire for PTCA ,Straight / J tip, Core material stainless steel , polymer tip , core to tip design , 0.014 with 0.8 tip load , with hydrophilic tip and light support 179 US FDA approved 190 cm long, tip load- 1.2 Extra support work horse wire for PTCA,Straight / J tip, Core material stainless Core material stainless steel , polymer tip , core to tip design , 0.014 , with hydrophilic tip and light support, 180 195cm-length, hydrophilic coating-33mm, 0.014”diameter, (Floppy, intermediate, standard ) work horse wire for PTCA,Straight tip/ J tip 181 hydrophilic coating-33mm, 300cm-length, 0.014”diameter, (Floppy, intermediate, standard ) work horse wire for PTCA,Straight tip/ J tip 182 190 cm long, tapered tip ,0.014 tapering to 0.009, 0.8 tip load CTO Wire for PTCA,Tapered tip 183 190 cm long, 0.014 tpering to 0.010 ,hydrophylic, 1 gm tip load CTO Wire for PTCA,Tapered tip 184 300 cm length,0.014 diameter, straight tip shape, 0.8 tip load double length CTO wire for PTCA,Straight tip 185 300 cm long, Tapered tip , 0.6 tip load CTO wire for PTCA,Tapered tip 186 180 cm length,0.014 diameter, straight tip shape, 0.8 tip load double length CTO wire for PTCA,Straight tip 187 180 cm length,( Straight tip shape ,3-4.5 tip load CTO wire for PTCA, silicone coating over spring coil , Straight tip 188 180 cm length,( Straight tip shape,)6-12 tip load CTO wire for PTCA,Straight tip 189 180cm length, 9- 12 tip load CTO wire for PTCA( tip shape straight,),tapered & straight tip 190 180cm length, 20 tip load CTO wire for PTCA( tip shape straight ),tapered & straight tip 191 180cm length, 1 tip load CTO wire for PTCA( tip shape straight) ,Hybrid wire that fuses Nitinol& stainless steel, , 180 cm & 300 hydrophilic coating over the distal 24.8cm of the distal tip , silicone tip on the distal 2mm , nitinol floppy tip, Straight tip 192 180cm length, 3.6 tip load CTO wire for PTCA( tip shape straight) , Hybrid wire that fuses Nitinol& stainless steel, 180 cm & 300 hydrophilic coating over the distal 24.8cm of the distal tip , silicone tip on the distal 2mm , nitinol floppy tip,Straight tip 193 180cm length, 3.6 tip load CTO wire for PTCA( tip shape straight) , Hybrid wire that fuses Nitinol& stainless steel, 180 cm & 300 hydrophilic coating over the distal 24.8cm of the distal tip , silicone tip on the distal 2mm , nitinol floppy tip,Straight tip ,1:1 TORQUE 194 FDA approved190cm length, 1.7, tip load CTO wire for PTCA( tip shape straight) ,stainless steel core , core to tip design , 0.014 wire with 0.010 tip & hydrophilic coating, Straight tip 195 FDA approved 190cm length, 4.7 Tip load CTO wire for PTCA, steel core , spring coli tip , core to tip design , 0.010 tip ,hydrophilic tip coating, tip shape straight ,Straight tip 196 US FDA approved 190cm , 300 length, 1.5 tip steel core , polymer tip , core to tip design , 0.014 wire with tip load of 1.5 gm , hydrophilic coating , CTO wire for PTCA,J tip 197 US FDA approved190cm , 300 length, 2.7 tip ,steel core , polymer tip , core to tip design , 0.014 wire with tip load of 2.7 gm , hydrophilic coating load CTO wire for PTCA,J tip 198 190cm ,300 length, 4.1 tip load steel core , polymer tip , core to tip design , 0.014 wire with tip load of 4.1 gm , hydrophilic coating load CTO wire for PTCA,J tip 199 330cm length, 3 tip load CTO wire for PTCA, tip shape straight , for guidewireexternalisation for retrograde procedures 200 US FDA APPROVED 190cm length, 4.8- 9.7 tip load CTO wire for PTCA,spring coil tip , core to tip design , 0.012 diameter ,Straight tip 201 US FDA approved 190cm length, 12.5- 13.3 tip load steel core ,coil tip , core to tip design , 0.010 to 0.009 tapered tip ,CTO wire for PTCA( tip shape straight , hydrophilic coating Straight tip 202 190cm ,300 cm length, 0.014 tapering to 0.010, 1.7 tip load CTO wire for PTCA ,Tapered tip, 1 mm preshaped tip, microcone tip 203 190cm ,300 cm length, 0.014 tapering to 0.011, 3.5 tip load CTO wire for PTCA tip shape tapered , Tapered tip1 mm preshaped tip, microcone tip 204 190cm ,300 cm length, 0.014 tapering to 0.012, 4.5 tip load CTO wire for PTCA( tip shape tapered , Tapered tip,1 mm preshaped tip, microcone tip 205 0.018 diameter peripheral floppy wire ( tip shape straight / length 80,180,300cm, Straight tip 206 0.025diameter peripheral floppy wire ( tip shape straight / length 80,260,300cm,Straight tip 197 US FDA approved190cm , 300 length, 2.7 tip ,steel core , polymer tip , core to tip design , 0.014 wire with tip load of 2.7 gm , hydrophilic coating load CTO wire for PTCA,J tip 198 190cm ,300 length, 4.1 tip load steel core , polymer tip , core to tip design , 0.014 wire with tip load of 4.1 gm , hydrophilic coating load CTO wire for PTCA,J tip 199 330cm length, 3 tip load CTO wire for PTCA, tip shape straight , for guidewireexternalisation for retrograde procedures 200 US FDA APPROVED 190cm length, 4.8- 9.7 tip load CTO wire for PTCA,spring coil tip , core to tip design , 0.012 diameter ,Straight tip 201 US FDA approved 190cm length, 12.5- 13.3 tip load steel core ,coil tip , core to tip design , 0.010 to 0.009 tapered tip ,CTO wire for PTCA( tip shape straight , hydrophilic coating Straight tip 202 190cm ,300 cm length, 0.014 tapering to 0.010, 1.7 tip load CTO wire for PTCA ,Tapered tip, 1 mm preshaped tip, microcone tip 203 190cm ,300 cm length, 0.014 tapering to 0.011, 3.5 tip load CTO wire for PTCA tip shape tapered , Tapered tip1 mm preshaped tip, microcone tip 204 190cm ,300 cm length, 0.014 tapering to 0.012, 4.5 tip load CTO wire for PTCA( tip shape tapered , Tapered tip,1 mm preshaped tip, microcone tip 205 0.018 diameter peripheral floppy wire ( tip shape straight / length 80,180,300cm, Straight tip 206 0.025diameter peripheral floppy wire ( tip shape straight / length 80,260,300cm,Straight tip 207 0.035 diameter peripheral wire ( tip shape straight / length 180,260cm, Straight tip 208 0.018 diameter peripheral intermediate wire ( tip shape straight / length 80,180,300cm, Straight tip 209 0.018 diameter peripheral standard wire ( tip shape straight / length 80,180,300cm, Straight tip 210 0.025 diameter, peripheral intermediate wire ( tip shape straight / length 260,180,300cm, Straight tip 211 0.025diameter, peripheral standard wire ( tip shape straight / length 260,180,300cm) ,Straight tip 212 195cm-length, hydrophilic coating-35mm, 0.014”diameter, (tipload-12g ),Straight tip/ J tip 213 hydrophilic coating-35mm, 300cm-length, 0.014”diameter, (tip load 12g),Straight tip/ J tip 214 195cm-length, hydrophilic coating-33mm, 0.014”diameter, Stainless Steel coil length-26mm, floppy & standard, J tip 215 hydrophilic coating-33mm, 300cm-length, 0.014”diameter, Stainless Steel coil length-26mm, floppy &standard,J tip 216 195cm-length, hydrophilic coating-27mm, 0.014”diameter, with polymer cover, Floppy, intermediate, standard,Straight tip/ J tip 217 hydrophilic coating-27mm, 300cm-length, 0.014”diameter, with polymer cover, Floppy, intermediate, standard,Straight tip/ J tip 218 185cm-length, hydrophilic coating-40mm, 0.014”diameter, Stainless Steel coil length-2cm, Floppy, intermediate, standard,Straight tip/ J tip 219 hydrophilic coating-40mm, 300cm-length, 0.014”diameter, Stainless Steel coil length-2cm, Floppy, intermediate, standard,Straight tip/ J tip 220 FDA Approved Nitinol Wire with Soft & A traumatic tip with Hydrophilic coating at the distal end & hydrophobic at the proximal end core to tip design, 0.8 g tip load,Straight tip/ J tip 221 Extra support wire guide for neonatal interventions: Nitinol core, PTE coating , flexible platinum tip. 1:1 torque control. 014 and 018 inch, 180,270 and 300 cm lenth. . Internationally accepted Cook quality and equal performance needed for patient safety 222 PTFE Guidewire :018, 021,025 inch, Regular and exchange length 223 FDA Approved Nitinol Wire with Soft & A traumatic tip for excellent torque and tip control with .9g tip load, stainless steel, straight tip/j tip 224 FDA Approved Peripheral Guide Wire for CTO, Stainless steel with Microglide coating , 4.8 to 13 gm tip load ,190,300cm Length 225 DOC EXTENSION 0.14-0.018 X 145 cm , CAN BE DETACHED AFTER USE designed to provide the necessary length to allow the exchange of one cathether for another while maintaining the position of the guide wire in the artery 226 Permanent Pacemaker-VVI/VVIR:Tined lead OR screw in lead+sheath(1),1.5/3T MRI with limited warranty(1PG+1Lead+1Sheath) 227 Permanent Pacemaker-DDD/DDDR:Tined lead & screw in lead+sheath,1.5/3T MRI with limited warranty(1PG+2 Lead+2 Sheath) 228 Permanent pacemaker-DDD/DDDR:Tined lead & Screw in lead+sheath(2),1.5/3T MRI compatible pacemaker:with life time warranty(1 PG+2 LEAD+2 SHEATH) 229 Permanent pacemaker-DDD/DDDR:Physiological pacing leads & Accessories,1.5/3T MRI compatible pacemaker:with life time warranty(1PG+2 LEAD+2Sheath + 1HIS CATHETER) 230 Permanent pacemaker-DDD/DDDR:Physiological pacing leads & Accessories,1.5/3T MRI compatible pacemaker:with limited warranty(1PG+2 LEAD+2Sheath+1 HIS Catheter) 231 ICD:SINGLE CHAMBER NON MRI 232 ICD:DUAL CHAMBER NON MRI 233 ICD:SINGLE CHAMBER 1.5/3T-MRI 234 ICD:DUAL CHAMBER 1.5/3T-MRI 235 ICD:SINGLE CHAMBER 1.5/3T-MRI 236 CRT-P:Bipolar1.5/3T-MRI 237 CRT-P:Quard 1.5/3T-MRI 238 CRT-P:Bipolar non MRI 239 CRT-D:QUARD 1.5/3T MRI 240 CRT D:BIPOLAR,Non MRI 241 Absorbable antibacterial envelope with cardiac implatable electronic devices(CIEDs) 242 Nitinol stent system for illiac arteries 0.035 compatible diameters-12mm,guidewire-0.035,Lenghts-20,30,40,50,60,70,80,100,120cm Delivery system length -75,120cm 243 Nitinol stent system for illiac arteries 0.018 compatible diameters-6,7,8,9,10mm,guidewire-0.018,Lenghts-20,30,40,60,80cm 244 Nitinol stent system for SFA 245 Self expandable peripheral stent system,Diameter:3.8mm-4.5mm/Length:16-76mm 246 Self expandable peripheral stent system,Diameter:9mm-14mm/Length:8cm-120cm 247 FDA approved SFA self expanding peripheral stent,length from 120-150mm on 135cm catheter 248 Balloon expandable peripheral stent:5mm-10mm/Length 12mm-57mm 249 Peripheral balloons(OTW)-Various sizes 250 IABP pressure cable and ECG cable set:suitable for datascope machine 251 IABP Balloon Datascope compatible 252 Helium cylinder for IABP Datascope machine compatible 253 2-3-3F size coronary micro snare,Length 150-175cm 254 3.2F size coronary snare,Length 150cm 255 4-6F size coronary snare,length -100 to 120cm 256 6-7Fsize coronary snare length-100cm 257 Peripheral snare-various sizes 258 Balkins sheath-various sizes 259 Mother & Child catheter,5-8F 260 Cutting balloon,diameter:2-4mm,length 6-15mm 261 Scoring balloon,diameter 2-4mm/length-6-15mm 262 Zero Transition /NBP:12atm,RBP:18-20 atm/Crossing profile:0.0336"DCGI approved.CE approved/Available length(in MM):8,10,12,15,18/Available Diameter(in MM):1.75,2,2.25,2.5,2.75,3,3.25,3.5,3.75,4,4.5,5 263 P tech shaft/SubZerotappered tip/NBP:6atm/RBP:16atm/Tip entry profile:0.0164"Crossing profile .0216 and 0.0336/Available Diameter(in MM):1,1.25,1.5,1.75,2,2.25,2.75,3,3.25,3.5,4/ available length(in MM): 5,8,10,12,15,20 264 Material:nylon blend/Balloon Compiance:Non Compliant/Crossing profile:0.0313"/.0.79mm/Diameter(in mm):1.75,2,2.25,2.5,2.75,3,3.5,4/Length:10,15,20/USFDA approved,DCGI Approved. 265 Material:L605 Cobalt cromium/Drug:Everolimus eluting with biodegradable polymer/Strut thickness:65 micron/Design:Uniform Sinusoidal/Crossing profile:1mm/Length(in MM): 8,10,12,13,15,16,18,20,24,28,32,36,40,42,44,48/Diameter(in MM)2.25,2.5,2.75,3,3.5,4,4.5 & 5 266 DCGI approved,Cobalt chromium Everolimus DES,/60 micron Strut thickness/crossing profile:0.0374"/C and P design connectors/"Conformal" coating technology for long term durability and preventing erosion of Drug Polymer matrix/lengths from 7mm to 45mm/Diameters from 2.25mm to 4mm 267 Cobalt Chromium Sirolimus DES/9 crown per segment design/CE marked,DCGI approved/65micron strut/Gamma radiation sterlized/ Balloon Material:Polymide Compound/Foldings 2-4 fold balloons/Crossing profile:0.90mm to 1.15mm/Tip Profile 0.43 mm/0.017"/Dual Strut width/Lengths from 8mm to 48mm/Diameter:2.25mm to 4mm 268 Transparent Hub/Work your size Nylon balloon with plus minus 10 percent growth/Tip profile of 0.017 inch/Diameters from 1.5 to 4mm /Length 6,9,11,12,14,16,18,20,22,24,26 and 30mm/small tip and crossing profile for CTO/TDM folding/Diameter from 1.2 to 2mm/8,10,12,15,20,25 and 30mm lengths/capable for kissing balloon under 6 F catheter. 269 Strong radial strength with 22 ATM high RBP/TDM folding,hydrophilic coating on distal shaft,Short shoulder design/Diameter from 1.5 to 4mm/Lengths:6,8,10,12,15,20,25 and 30mm/Tip Profile:0.018" 270 SEMI COMPLIANT BALLOON CE/ FDA APPROVED HYDRO X COATING , XD SHAFT, Z TIP, BALLOON DIAMETER. 1MM, 1.25MM, 1.5MM, 2.MM, 2.25MM, 2.75MM, 3MM, 3.25MM, 3.5MM 4MM 271 NON COMPLIANT BALLOONS, CE/FDA APPRIVED, HYDRO X COATING, GUID WIRE LUMEN INVIO COATING BALLOON DIAMETERS 1.75MM,2MM,2.25MM,2.5MM,2.75MM,3MM,3.25MM,3.5MM,3.75MM,4MM,4.5MM,5MM 272 EVEROLIMUS ELUTING CORONARY STENT SYSTEM, COBALT CHROMIUM PLATFORM,65 MICRON STRUT THICHKNESS, HYBRID DESIGN,STARIGHT CONNECTORS ENGINEERD FROM VALLEY TO TOP, BIO DEGRADABLE POLYMER, PLATINUM IRIDIUM RADIO OPAQUE MARKERS WITH A DIFFERENCE BETWEEN STENT EDGE AND MARKER LESS THAN 0.5MM,STRUT WIDTH 70 MICRON,DIAMETER FROM 2 TO 4.5MM LENGTHS 8,12,16,20,24,28,32,36,40,44,48,52MM 273 SIROLIMUS ELUTING CORONARY STENT SYSTEM,COBALT CHROMIUM PLATFORM,65 MICRON STRUT THICKNESS, HYBRID DESIGN,STARIGHT CONNECTORS ENGINEERD FROM VALLEY TO TOP, BIODEGRADABLE POLYMER, PLATINIUM IRIDIUM RADIO OPAQUE MARKERS WITH A DIFFERENCE BETWEEN STENT EDGE AND MARKER LESS THAN 0.5MM,STRUT WIDTH 70 MICRON,DIAMETER FROM 2 TO 4.5MM. LENGTHS 8,12,16,20,24,28,32,36,40,44,48,52MM 274 SEMI COMPLIANT BALLOON CE/ FDA APPROVED SUB ZERO TIP, XD SHAFT, HYDRO X COATING WITH TIP ENTRY PROFILE OF 0.0208. DIAMETERS FROM 0.85 TO 4MM, LENGTHS FROM 10MM TO 30MM 275 NON COMPLIANT BALLOONS, CE/FDA APPRIVED, HYDRO X COATING, GUID WIRE LUMEN INVIO COATING. TIP ENTRY PROFILE OF 0.0345 WITH DIAMETER 1.5 TO 5MM.LENGTH OF 6 TO 28MM WITH RBP UPTO 24 ATM 276 DCGI APPROVED SEMI COMPLAINT , NON COMPLAINT PTCA BALLOON DIALATION CATHETER DIAMETER IN MM 1.5,2.0,2.25,2.50,2.75,3.0,3.25,3.5,3.75,4.0,4.5 LENGTH OF MM 6,8,10,12,15,20,25,30,33,38,41 LOW COMPLIANCE <8%,REDUCED TIP AND BALLOON PROFILE 140CM USABLE SHAFT LENGTH, 25CM RAPID EXCHANGE LENGTH 277 CE APPROVED Everolimus Eluting Coronary Stent System Ø Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Ø Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Ø Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Ø Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. 278 CE APPROVED Sirolimus Eluting Coronary Stent System Ø Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Ø Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Ø Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Ø Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. 279 ONLY DCGI APPROVED Sirolimus Eluting Coronary Stent System Ø Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Ø Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Ø Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Ø Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. 280 PTCA Guide Wire – 2 mm Silicon coated distal tip, 0.014” Diameter and 180 cm length PTCA wire • Must have Platinum coil at distal tip. • Must have directly jointed SUS and Nitinol shaft through DuoCore technology and silicon coated joint. • Should have M coat hydrophilic coating upto 248 mm from 25 to 180 cm length. Should be Available in 0.6 gf, 1gf & 3.6gf tip loads & Intermediate tip . 281 CTO Balloon with Ultra - Low Entry profile of 0.016" with hydrophilic coating for superior crossability. RED clored tip with easy recognisation. smallest diameter of 1.00mm and 5mm length Shorter and Thinner radiopaque marker for lower crossing profile ( Length of 0.8mm and thickness of 25μm) Flexible Tip with short balloon bonding part of 0.4mm. Robust and improved core wire shaft for better pushability. PMDA Approved/USFDA 282 NON Complaint balloon with Innovative triple layer balloon technology, outer layer of Elastomer, middle layer of Polyamide and inner most layer of Elastomer. to provide outstanding flexibility and crossing performance. High pressure non-compliant balloon with nominal pressure of 12atm and RBP of 22atm. Flexible thin distal tip with low entry profile of 0.43 mm. PMDA Approved/USFDA 283 Radial Artery Haemostasis Device- (T.R. Band) Consists of two balloon specially designed for spot compression of the radial puncture site. Must have belt magic tape for fast application. Must have curved support plate. Must have green marker for appropriate positioning. Must be available in 2 sizes – 24cm and 29cm USFDA+PMDA approved Coronary micro-Guide catheter 284 • Must Have tapered stainless steel braid mesh construction and Inner PTFE Layer. • Must Have 13 CM floppy distal segment. • Must Have Distal outer diameter 1.8 Fr or less and Proximal Outer diameter 2.6Fr. • Must have 70cm distal hydrophilic coating. • Must be available in Catheter Length 130cm for antegrade approach and 150 cm for retrograde approach. • Must have Gold marker for the tip visibility • USFDA/PMDA approved 285 Vascular closure device with Bio absorbable PGA suture that provide a secure seal • Bioabsorbable collagen designed, • low profile Bioabsorbable Anchor (50:50 blend glycolide and lactide polyer) • Must have bovine collagen plug. Must have 9 hole V-twist pattern suture weave. • Must be available in 6F and 8F sizes. • USFDA+PMDA Approved 286 Aspiration Thrombectomy Catheter • Available in Size 6F, 7F Both, Must have entry profile 0.019 inches • Must Have 1.30 mm square suction area • Braided polyamide elastomer shaft, stainless steel wire braiding and Guide wire type Stylet, • 6.0mm tip length for making aspiration inlet to come closer to the target thrombus and 10cm-length depth. • Must Have Distal 40 cm Hydrophilic coating. • PMDA Approved 287 Sirolimus Eluting Stent Cobalt-Chromium stent with Abluminal Specialised Gradient coating ( should not have drug & Polymer coating on joints & Bends ). • Must Have Advanced Core wire shaft technology. • should have an over expansion Limit of more than 1.5 mm of the stated Diameter • Must Have Rounded & Flexible Tip made up of Polyamide Elastomer. • Should have Bioinspired Open cell in phase design. Bioresorbable polymer of PLCL (Poly Lactic Acid + Poly Capro lactone PCL) with degradation time of 3-4 months. • Low concentration of Sirolimus (0.8ug/mm sq), tip entry profile of 0.42mm. • PMDA Approved 288 • Sirolimus Eluting Stent Cobalt-Chromium stent with Abluminal Coating and specialised Gradient coating (No polymer coating at joint & Bends). • Bioresorbable polymer of PLCL (Poly Lactic Acid + Poly Capro lactone PCL) with degradation time of 3-4 months. • Low concentration of Sirolimus (0.8ug/mm sq), • Should have Bioinspired Open cell inphase design. minimum tip entry profile of 0.42mm PMDA Approved 289 DUAL DRUG SIROLIMUS COATED STENT: Fusion coating both stent & ballon with drug coating,Edge coating: 0.5 mm of proximal and distal ends of ballon . Sizes:2.25-4 mm lengthLenth:8-40 mm 290 DES,sirolimus FDA/DCGI/CE Approved cobalt chromium platform 291 Sirolimus eluting balloon nanolute propritory nano carrier drug eluting technology drug: 1.27 u/mm of sirolimus Drug release within 60 secs. 14 to 28 days bio availability in target tissue ,size: 2mm -4mm length: (FDA/CE APPROVED) 292 Sirolimus eluting peripheral balloon nanolute propritory nano carrier drug eluting technology. low crossing profile ,size:4 mm-8mm length: 40mm- 200 mm 293 Thrombus Aspiration Catheter with braided technology, Catheter length 145cm, maximum tip diameter - 1.73, 1.98, Guide catheter - 6, 7F 294 Everolimus Eluting Coronary Stent System with length 8mm to 48mm & diameter of 2.00 mm to 4.50 mm.Crest :6 Valley to Valley connectors:2. Material : L605 alloy (Cobalt Chromium). Design : Open Cell design with Valley-to-Valley Connectors( 55 ± 10 μm). Strut thickness : 60 mm ± 10 μm/ Strut width : Struts: 65 ± 10 μm / Drug dose : 1.20 μg/mm2./SDS: Semi-compliant Polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm & 48 mm/ Hydrophilic Coating: Distal & proximal shaft of balloon delivery system. Proximal shaft markers: 90 cm & 100 cm .Mounted stent length and location defined by radio opaque marker band. NBP: 9 atm / (RBP): 16 atm*/ *RBP 16atm for all the variants except the ones given below whose RBP is 14atm:3.50 x 36 mm, 40 mm, 44 mm & 48 mm / 4.00 x 32 mm, 36 mm, 40 mm, 44 mm & 48 mm Stents / 4.50 mm. (SE-Mkr)<0.5mm (at both sides, proximal & distal) 295 Sirolimus Eluting Coronary Stent System with length 8mm to 48mm & diameter of 2.00 mm to 4.50 mm.Crest :6 Valley to Valley connectors:2. Material : L605 alloy (Cobalt Chromium). Design : Open Cell design with Valley-to-Valley Connectors( 55 ± 10 μm). Strut thickness : 60 mm ± 10 μm/ Strut width : Struts: 65 ± 10 μm / Drug dose : 1.33 μg/mm2./SDS: Semi-compliant Polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm & 48 mm/ Hydrophilic Coating: Distal & proximal shaft of balloon delivery system. Proximal shaft markers: 90 cm & 100 cm .Mounted stent length and location defined by radio opaque marker band. NBP: 9 atm / (RBP): 16 atm*/ *RBP 16atm for all the variants except the ones given below whose RBP is 14atm:3.50 x 36 mm, 40 mm, 44 mm & 48 mm / 4.00 x 32 mm, 36 mm, 40 mm, 44 mm & 48 mm Stents / 4.50 mm. (SE-Mkr)<0.5mm (at both sides, proximal & distal) 296 PTCA Non Compliant Balloon Catheter:Zero transition NBP:12 atm / RBP : 18 -20 atm / Proximal shaft diameter: 2 french/ Catheter working length:140 cm / Material: Nylon/Folds :3 to 5/Crossing profile: 0.0336"/Marker: 2 bands/Coating: Hydrophilic (distal tip to guidewire exit port), Hydrophobic (guidewire lumen invio)/Available Diameter(in MM): 1.75 , 2 , 2.25, 2.5, 2.75, 3, 3.25, 3.5 , 3.75 , 4, 4.5, 5/Available length (in MM):8, 10, 12, 15, 18/DCGI approved, CE approved/FDA 297 PTCA Semi Compliant Balloon Catheter:P tech shaft / Sub zero tappered tip/ Material : pebax/Folds: 3 folds/Tip entry profile:0.0164"/Crossing profile 0.0216 and 0.0336 / Distal shaft diameter: 2.36-2.7 french/Marker:2 bands/Coating:Hydrophilic (distal tip to guidewire exit marker); Hydrophobic (guidewire lumen) / Diameter (in MM) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in MM): 5, 8,10,12,15,20 / USFDA / CE / DCGI approved 298 CE/USFDA approved / Hydro X coating(XD shaft, Z tip balloon diameter / Diameter (in MM) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in MM): 5, 8,10,12,15,20 299 CE/USFDA /DCCGI approved / Hydro X coating guidewire lumen / TEP: 0.0345" / Dia: 1.5-5mm / Length: 6-28mm / RBP:utpo:24 atm 300 Scoring balloon catheter:Catheter type: rapid exchange / Guidewire lumen diameter:0.014"/Material: nylon blend/Balloon compiance: Non Compliant /Crossing profile:0.0313"/.0.79 mm/ Coating(distal shaft and tip): hydro x hydrophilic coating / Coating (guidewire lumen): invio hydrophobic / NBP: 12 atm / RBP: 20 atm/Available Diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / Available length (in mm):10, 15, 20 / USFDA / CE approved 301 Hydrophilic guidewire / Nitinol core wire / polyurethane jacket with tungsten tip for radiopacity / 1:1 transmission / Outer dia: 0.018 , 0.032&0.035mm / Lengths : 150,180&260 mm 302 DCGI approved Biodegradable polymer based everolimus eluting Coronary stent system with differencial stent architecture of 6 crown design for 2 - 2.75 mm , 8 crown for 3-3.5 & 10 crown design for 4-4.5 mm Length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. Diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5 303 CE approved Biodegradable polymer based Sirolimus eluting Coronary stent system with differencial stent architecture of 6 crown design for 2 - 2.75 mm , 8 crown for 3-3.5 & 10 crown design for 4-4.5 mm Length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. Diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5 304 Rapid Exchange Semicomplaint Balloon . Balloon Size: 1.2 mm - 5 mm Length 6mm - 42mm (DCGI/CE Approved) 305 Semicomplaint balloon. Balloon Size : 1.5mm - 2.5mm/Length : 8mm-20mm rapid exchange proximal shaft 0.72mm and distal shaft -0.90mm,TIP profile 0.018 with Nominal inflation pressure 8 atm& RBP-16 ATM,and having two plantium iri dum makers(DCGI/CE APPROVED) 306 Rapid Exchange Non complaint Balloon . Balloon Size: 1.2 mm - 5 mm Length 6mm - 42mm (DCGI/CE Approved) 307 CE approved Thrombus ASPIRATION CATHETER with removable core wire and 30cm hydrophilic coating from the tip; Available in 6F and & 7F. Length 140 cm DCGI APPROVED Thrombus Aspiration Catheter 308 CE approved bioabsorbable polymer sirolimus drug eluting stent with abluminal in-groove design and differencial stent architecture of 6 crown design for 2.25 mm- 2.5 mm , 7 crown design for 2.75 mm-3.0 mm & 9 crown design for 3.5 mm-4.0 mm Length : 13 mm.16,18,21,23,26,29,31,33,35 & 38. Diametre : 2.25 mm, 2.5,2.75,3,3.5 & 4. 309 CTO/SEMI-COMPLAINT LOW ENTRY PROFILE BALLOON(TR2 COATING) , Entry Profile 0.0157 Inch , Dia- 1.00,1.20,1.50,2.00,2.25,2.50,2.75,3.00 ,3.25,3.50,3.75,4.00Length - 06,08,10,12,15,20,30 - Shaft 2.3Fr - Effective length 1460mm 310 NON-COMPLAINT BALLOON(TR2 COATING) , Shaft Outer Diameter (Proximal) : 2.1Fr/0.70mm , Dia - 1.50,1.75,2.00,2.25,2.50,2.75,3.00,3.25,3.50,4.00,4.25,4.50 Length - 08,10,13,15,20 - Effective Length 1460mm 311 THROMBUS ASPIRATION CATHETER , Removable Core Wire ,6 & 7 FR Effective Length 1400mm 312 DOUBLE LUMEN CATHETER , For Bifurcation & Side Branch Lesion 313 ONLY DCGI APPROVED Everolimus Eluting Coronary Stent System Ø Struts/Cells shows a wavy pattern and are not straight with outerradius of 0.1725mm. The Cell angle is between 42 degree to 57 degree with respect to different diameter. The cells are connected by “Link” (Mid to Mid pattern) with a Radius of 0.2700mm. These values have been validated for lower stent profile, uniform expansion, side branch access, good trackability & strong radial support. Ø Components - Drug: Everolimus, Stent Platform: Cobalt Chromium L605 alloy, Polymer: Biodegradable, Catheter: PTCA Rapid exchange semi-compliant Stent delivery catheter. Drug Concentration: 1.2 microgram/mm2 of stent surface area. Ø Stent Diameter(mm): 2.00, 2.25, 2.50, 2.75, 3.00, 3.50, 4.00 & 4.50 & Stent Length (mm): 8, 13, 16, 20, 24, 28, 32, 36, 40, 43, 47 Ø Platinum-Iridium radiopaque markers are precisely placed within the balloon cones for accurate stent positioning, Also the difference between stent edge to marker is <0.5mm (atboth sides, proximal & distal) which prevents the dogboning during the angioplasty. 314 Everolimus drug eluting cobalt chromium stent with 65 microns struct thickness with different compostion of cibalt chromium bonding L, 605 platform with imine polymer technology of biodegradable and biocompatible with PLGA polymer, drug loading density1.2ug/mm2, 6um coating thickness,95% Everolimus drug released with in 120days, re=endothelization with in 90days, lessing profile of balloon &stent 315 Semi compliant coronary balloon with tip entry profile of 0.017 or less; 5F compatible ;3 Dimensional memory fold Rivarp technology for optimum performance and upto 16 ATM RBP. Dia from 1.5 to 4.0 mm and length from 9mm to 30mm v316 Non compliant coronary balloon with tip entry profile of 0.018 or less; 3Dimensional Rivarp memory fold technology for optimum performance and upto 22 ATM RBP. Dia from 1.5 to 4.5 mm and length from 6 mm to 30 mm 317 Non compliant coronary balloon with tip entry profile of 0.018 or less; 3Dimensional Rivarp memory fold technology for optimum performance and upto 22 ATM RBP. Dia from 1.5 to 4.5 mm and length from 6 mm to 30 mm 318 Self expandable double disc device made of Nitinol mesh with polyster fabric for immediate occlusion.Sizes from 8 to 42 mm. 319 Self expandable double disc device made of Nitinol mesh made with a 7 mm waist length to accommodate muscular septal wall.Sizes from 4 -14 mm 320 Self expanding device made of nitinol wire mesh in a T Cone shaped mesh,Polyster fabric interior for immediate occlusion and faster reendotheliazation.All standard sizes 321 Delivery System consists of a Delivery Sheath, Dilator, Loader, Hemo Static Valve and delivery cable for the delivery of ASD/PDA/VSD Occluder. 322 CTO wire, 190 cm Pre shape Tip, 2.0 gf Tip Load, 15cm Radiopacity, Hydrophilic 40 cm, Uncoated Distal Tip.Guide wire with ACT one and XTRAND coil to improve navigation. 323 CTO wire, 190 cm Pre shape Tip, 4.0 gf Tip Load, 15cm Radiopacity, Hydrophilic 40 cm, Uncoated Distal Tip.Guide wire with ACT one and XTRAND coil to improve navigation 324 CTO wire, 190 cm Pre shape Tip, 6.0 gf Tip Load, 15cm Radiopacity, Hydrophilic 40 cm, Uncoated Distal Tip.Guide wire with ACT one and XTRAND coilto improve navigation. 325 Micro Catheter, 135 cm, 1.4 Fr Tip Outer Diameter, 1.9 Fr Distal Shaft Outer Diameter , 2.6 Fr Proximal Shaft Outer Diameter, 0.016 inch Tip Inner Diameter, 0.022 inch Shaft Inner Diameter. Hydrophilic Coating Length 70 cm. 326 Micro Catheter, 150 cm, 1.4 Fr Tip Outer Diameter, 1.9 Fr Distal Shaft Outer Diameter , 2.6 Fr Proximal Shaft Outer Diameter, 0.016 inch Tip Inner Diameter, 0.022 inch Shaft Inner Diameter. Hydrophilic Coating Length 85 cm. 327 CTO wire 180cm, 3gf Tip Load, Straight, 11cm Radiopacity Tip, Hydrophilic 40cm, Uncoated distal tip 328 PTCA workhorse wire 180cm St/J Tip, Radiopacity 3 cm, 20 cm Spring Coil length, 0.8 gf Tip Load, Floppy Tip for moderate core wire support. Silicone Coating upto 30 mm from the tip, slipcoat over spring coil. 329 PTCA wire, 190 cm Straight Tip, 0.3 gf Tip Load, 3cm Radiopacity, Hydrophilic Coating 52 cm. 19 cm Spring Coil Length, high tension stainless steel core,. 330 PTCA wire, 190 cm Straight Tip, 3 cm Radiopacity, 8.5 cm Spring Coil Length, 3.0 gf Tip Load, Hydrophilic Coating. 331 PTCA wire, 200 cm Straight Tip, 3 cm Radiopacity, 11 cm Spring Coil Length, 3.0 gf Tip Load, Hydrophilic Coating. 332 PTCA wire extension, 165 cm Straight Tip 333 Micro Catheter, 135 cm Length, 1.3 Fr Tip Outer Diameter, 2.6 Fr Distal Shaft Outer Diameter, 2.8 Fr Proximal Shaft Outer Diameter, 0.015 inch Tip Inner Diameter, 0.018 inch Shaft Inner Diameter. 334 Micro Catheter, 135 cm for Retrograde Complexity. 1.3 Fr Tip Outer Diameter, 2.1 Fr Distal Shaft Outer Diameter, 2.9 Fr Proximal Shaft Outer Diameter. 0.015 inch Tip Inner Diameter, 0.019 inch Shaft Inner Diameter. Hydrophilic Coating 70 cm. 335 Micro Catheter, 150 cm for Retrograde Complexity. 1.3 Fr Tip Outer Diameter, 2.1 Fr Distal Shaft Outer Diameter, 2.9 Fr Proximal Shaft Outer Diameter. 0.015 inch Tip Inner Diameter, 0.019 inch Shaft Inner Diameter. Hydrophilic Coating 85 cm. 336 CTO Wire 180cm, 9.0 gf Tip Load, Straight Tip, Hydrophilic uncoated ball tip, 20cm coil length, Hightnesion Stainless Steel Core wire 337 CTO Wire 180cm, 12.0 gf Tip Load, Straight Tip, Hydrophilic uncoated ball tip, 20cm coil length, Hightnesion Stainless Steel Core wire 338 CTO wire, 190 cm Straight Tip, 0.6 gf Tip Load, 16 cm Radiopacity, 17 cm Polymer Jacket Length, Tip Outer Diameter 0.010 inch, Slip Coat Coating over polymer jacket, Flexible and Tapered Tip. Hydrophilic 17 cm. 339 Everolimus Eluting Coronary Stent System with length 8mm to 52 mm & diameter of 2.00 mm to 4.50 mm.Crest :6 Valley to Valley connectors:2. Material : L605 alloy (Cobalt Chromium). Design : Open Cell design with Valley-to-Valley Connectors( 55 ± 10 μm). Strut thickness : 60 mm ± 10 μm/ Strut width : Struts: 65 ± 10 μm / Drug dose : 1.20 μg/mm2./SDS: Semi-compliant Polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm & 52 mm/ Hydrophilic Coating: Distal & proximal shaft of balloon delivery system. Proximal shaft markers: 90 cm & 100 cm .Mounted stent length and location defined by radio opaque marker band. NBP: 9 atm / (RBP): 16 atm*/ *RBP 16atm for all the variants except the ones given below whose RBP is 14atm:3.50 x 36 mm, 40 mm, 44 mm , 48 mm & 52 mm/ 4.00 x 32 mm, 36 mm, 40 mm, 44 mm, 48 mm & 52 mm Stents / 4.50 mm. (SE-Mkr)<0.5mm (at both sides, proximal & distal). DCGI approved 340 Abluminal coated Everolimus Eluting Coronary stent : Design : Open cell , Strut Design : Open Cell with valley to valley S Connectots(V2VS) , Strut width: Wavflo Struts : 65+/-10um & valley to valley "S" connectors: 55+/- 10um, Guidewire compatibility : 0.014"(0.36 mm),Polymer: Biodegradable, Strut Thickness: 60+ /- 10um, Guiding catheter(inner diameter): 5 French , Crossing profile : 0.97 mm( for 3mm), radial strength : 1.5N/mm , L605 Stent Material: Cobalt Chromium , Number of crowns : 6 (2 - 3mm),8(3.5-4.5mm). Post dialatation : 4mm(2 - 3mm), 5.5mm(3.5-4.5mm). Diameter : 2mm-4.5 mm , Length available : 8mm - 52 mm 341 Sirolimus Eluting Coronary Stent System with length 8mm to 52 mm & diameter of 2.00 mm to 4.50 mm.Crest :6 Valley to Valley connectors:2. Material : L605 alloy (Cobalt Chromium). Design : Open Cell design with Valley-to-Valley Connectors( 55 ± 10 μm). Strut thickness : 60 mm ± 10 μm/ Strut width : Struts: 65 ± 10 μm / Drug dose : 1.33 μg/mm2./SDS: Semi-compliant Polyamide, nominally 0.5 mm > for stent length 8 mm to 40 mm & nominally 1.0 mm longer > for stent length 44 mm, 48 mm& 52 mm/ Hydrophilic Coating: Distal & proximal shaft of balloon delivery system. Proximal shaft markers: 90 cm & 100 cm .Mounted stent length and location defined by radio opaque marker band. NBP: 9 atm / (RBP): 16 atm*/ *RBP 16atm for all the variants except the ones given below whose RBP is 14atm:3.50 x 36 mm, 40 mm, 44 mm , 48 mm& 52 mm / 4.00 x 32 mm, 36 mm, 40 mm, 44 mm, 48 mm& 52 mm Stents / 4.50 mm. (SE-Mkr)<0.5mm (at both sides, proximal & distal). DCGI approved 342 Drug Eluting Coronary balloon : Drug: Paclitaxel with natural resin : Shellac , Available balloon length : 8mm to 52 mm , Diameter: 2mm to 4.5 mm , Drug Dose : 2.3ug/mm square, Balloon material : Polyamide , Catheter design : Rapid Exchange Delivery system , Usable shaft: 140 cm., Guidewire compatibility:m0.014", Guiding catheter Inner Diameter: 5 French(0.056")(1.4mm)compatible, Catheter Outer Shaft Diameter(2.7 french proximal , distal 1.95 french), Balloon folding: 3 , Delivery system coating : hydrophilic , Nominal pressure : 8 atm , RBP: 2-4 mm.....16 atm)(4.5mm....14 atm) 343 PTCA Non Compliant Balloon Catheter:Zero transition NBP:12 atm / RBP : 18 -20 atm / Proximal shaft diameter: 2 french/ Catheter working length:140 cm / Material: Nylon/Folds :3 to 5/Crossing profile: 0.0336"/Marker: 2 bands/Coating: Hydrophilic (distal tip to guidewire exit port), Hydrophobic (guidewire lumen invio)/Available Diameter(in MM): 1.75 , 2 , 2.25, 2.5, 2.75, 3, 3.25, 3.5 , 3.75 , 4, 4.5, 5/Available length (in MM):8, 10, 12, 15, 18/DCGI approved, CE approved 344 PTCA Semi Compliant Balloon Catheter:P tech shaft / Sub zero tappered tip/ Material : pebax/Folds: 3 folds/Tip entry profile:0.0164"/Crossing profile 0.0216 and 0.0336 / Distal shaft diameter: 2.36-2.7 french/Marker:2 bands/Coating:Hydrophilic (distal tip to guidewire exit marker); Hydrophobic (guidewire lumen) / Diameter (in MM) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in MM): 5, 8,10,12,15,20 / CE / DCGI approved 345 CE / Hydro X coating(XD shaft, Z tip balloon diameter / Diameter (in MM) : 1 , 1.25,1.5,1.75, 2, 2.25, 2.75, 3, 3.25, 3.5, 4/length(in MM): 5, 8,10,12,15,20 346 CE/DCCGI approved / Hydro X coating guidewire lumen / TEP: 0.0345" / Dia: 1.5-5mm / Length: 6-28mm / RBP:utpo:24 atm 347 Non complaint high pressure coronary balloon : Proximal Shaft : 2.1 French , Distal shaft: 2.36 f(1.5-5mm) , tip length : 1.5mm(1.5-1.75 mm), 2mm(2-3mm), 2.5mm(3.25 - 5mm), Marker band: 1(1.5mm)(2(1.75-5mm), crossing profile : 0.0345", coating : Hydrophillic(tip-guidewire exit port)hydrophobic(guidewire lumen), Nominal pressure: 14 atm, RBP: 24atm(1.5-3.5mm) 22atm(3.75-4mm)20 atm(4.5-5mm), Material : Nylon & Pebax(dual layer), Balloon fold: 3(1.5-4mm)5(4.5-5mm), Balloon diameter : 1.5,1.75, 2,2.5,2.75,3.3.25,3,5,3.75,4,4.5,5mm , Length : 8,10,12,15,18,22,26mm, Guidewire compatibility : 5 F & 6 F 348 CTO coronary balloon : Proximal Shaft : 1.9 French , Distal shaft: 2.36 f(1.5-5mm) , tip length : 1.5mm, Marker band: single, crossing profile : 0.0208", coating : Hydrophillic(tip-guidewire exit port)hydrophobic(guidewire lumen), Nominal pressure: 6 atm, RBP: 16 atm, Material : Nylon, Balloon fold: 2(0.85-1mm)3(1.25 mm), Balloon diameter : 0.85 , 1, 1.25 mm , Length : 5,8,10,15,18mm, Guidewire compatibility : 5 F 349 Non Complaint Coronary balloon:Usable length:14cm(+/- 2 cm.). Proximal Shaft 2 french(0.66cm). Nominal Pressure: 12 atm, RBP: 20 atm, Balloon length : 8,10,12 15, 18 mm, Balloon diameter: 1.75, 2.2.25,2.5,2.75, 3, 3.25, 3.5, 3.75, 4, 4.5, 5mm, Radiopacity: Pt-Ir marker, Push force 1.9 newton, Balloon radial growth(NP-RBP)<6%, Balloon Longitudinal Growth<2.5%, 0.43 mm tapered profile, 2mm tri-layered atraumatic tip 350 Complaint Coronary balloon:Usable length:14cm(+/- 2 cm.). Proximal Shaft 2 french(0.66cm). Nominal Pressure: 6 atm, RBP: 16 atm, Balloon length : 5,8,10,12 15, 20 mm, Balloon diameter:1, 1.25,1.5,1.75, 2,2.25,2.5,2.75, 3, 3.5, 4 mm, Radiopacity: Pt-Ir marker, Push force 1.9 newton, Balloon radial growth(NP-RBP)<6%, Balloon Longitudinal Growth<2.5%, 0.43 mm tapered profile, 2mm tri-layered atraumatic tip, Nylo Flex(crossing profile:0.034") 351 Scoring balloon catheter:Catheter type: rapid exchange / Guidewire lumen diameter:0.014"/Material: nylon blend/Balloon compiance: Non Compliant /Crossing profile:0.0313"/.0.79 mm/ Coating(distal shaft and tip): hydro x hydrophilic coating / Coating (guidewire lumen): invio hydrophobic / NBP: 12 atm / RBP: 20 atm/Available Diameter (in mm):1.75, 2, 2.25, 2.5,2.75, 3, 3.5, 4 / Available length (in mm):10, 15, 20 / CE approved 352 Microcatheter: CE certified / Proximal / Distal Profile : 2.6 f / 2.0 F/Catheter Type : Over the wire/ Guiding catheter compatibility : 5 F / Max. GW O.D.: 0.014"/ TEP: 0.0190"/ Innerbody lumen dia:0.0170" / Innertip lumen dia: 0.0157"/ Catheter ext. coating: hydrophilic (60 cm of distal catheter including tip)/ Catheter working length : 135 cm (antegrade); 150 cm (retrograde) / Hybrid Braiding and Coil Construction: Layers: Inner Layer: PTFE Liner , Middle Layer: Hybrid Braiding and Coil & Outer Layer: Ultra-thin Polymer Jacket 353 Sirolimus eluting coronary stent system, Biodegradable polymer poly(D, l lactide) matrix, 65 micrometer strut thickness -Diameter 2.25,2.50,2.75,3.00,3.50,4.00,4.50 x 8,12,16,20,24,28,32,36,40mm DCGI approved ,L 605 cobalt chromium platform 65 micrometer struct thickness,Biodegradable polymer,Open and closed cell design (Hybrid) abluminal drug coated.zero foreshortening and dedicated cell design for small(6 cell),medium(8 cell) and large vessel(10 cell) minimizing overstretch. Swiss technology. 354 : Everolimus eluting coronary stent system, Biodegradable polymer poly(D, l lactide) matrix, 65 micrometer strut thickness -Diameter 2.25,2.50,2.75,3.00,3.50,4.00,4.50 x 8,12,16,20,24,28,32,36,40mm DCGI approved ,L 605 cobalt chromium platform 65 micrometer strut thickness,Biodegradable polymer,Open and closed cell design (Hybrid) abluminal drug coated.zero foreshortening and dedicated cell design for small(6 cell),medium(8 cell) and large vessel(10 cell) minimizing overstretch. Swiss technology. 355 L-25 Nylon material, thinnest balloon 0.008mm, deep sholder design with 42 degree cone angle, hydrophilic coated, 0.016 lowest entry profile 1.25mm-4.5mm and length 10mm to 40mm, Rapid exchange proximal shaft,NP 8 atm and RBP 18 atm working range and having two platinum iridium marker (DCGI and CE approved) PTCA balloon catheter semi complaint 1.25,1.50,2,2.25,2.50,2.75,3.00,3.25,3.50,4.00,4.5 * 10,12,15,20,25,30,35,40mm respectively 356 L-25 Nylon material, thinnest balloon 0.008mm, deep sholder design with 42 degree cone angle, hydrophilic coated, 0.016 lowest entry profile 1.50mm-5.00mm and length 10mm to 40mm, Rapid exchange proximal shaft,NP 8 atm and RBP 20 atm working range and having two platinum iridium marker (DCGI and CE approved) PTCA balloon catheter Non complaint 1.50,2,2.25,2.50,2.75,3.00,3.25,3.50,4.00,4.5 * 10,12,15,20,25,30,35,40mm respectively 357 DES, everolimus eluting,Strut thickness 60 microns,cobalt chromium platform,usable catheter length 145 cm,with crossing profile 0.0374 " 358 DES ,Sirolimus(1.0 microgram/mm2) eluting,strut thickness 60 microns,cobalt chromium platform from biodegradable polymer matrix 359 DES everolimus(1.1 microgram/mm2) eluting ,strut thickness 55 microns ,cobalt chromium platform,biodegradable polymer matrix 360 Semi compliant PTCA balloon catheter,CE approved,Tip entry profile 0.016" ,distal shaft 2.6F With platinium iridium marker bands,nominal pressure of 6 atm balloon size 1.2 -4.5 mm and length 7 to 45mm 361 Non compliant PTCA balloon catheter ,CE approved,Tip entry profile of 0.016",distal shaft 2.6 F WITH Platinum iridium marker bands ,nominal pressure of 14 atm,balloon size 1.2 to 4 mm and length 7mm to 45 mm 362 DES,Sirolimus eluting cobalt chromium platform,65 microns strut thickness,with a tip entry profile of 0.016" and crossing profile 0.037" 363 DES,Rapamycin eluting,Cobalt chromium platform,60 microns strut thickness 364 DES CE approved Sirolimus 1.3μm/mm2 ,cobalt chromium 59μm hybrid ultra low thickness strut for all diameters,2μm of PLLA & PLGA polymers and drug coating, crossing profile 0.88mm. Diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters. 365 DES DCGI approved Everolimus 1.00μm/mm2 ,cobalt chromium 59μm hybrid ultra low thickness strut for all diameters, PLLA & PLGA polymers, crossing profile 0.88mm.Diameter 2.25 to 4mm and lengths from 8 to 48mm in all diameters. 366 DES Everolimus Cobalt chromium DCGA approved 60μm strut thickness,3μm coating thickness, wider peak design and strut locking machanism for radial strength, PLGA polymer with hydrophilic coated delivery system. Size 2.25 to 5 diameter and length from 8mm to 48mm 367 Guide Extension Catheter with hydrophilic coating, length 1500mm. Outer diameter 1.35mm inner diameter-1.17mm, 2mm soft Atraumatic tip with 3mm long entry port and stainless steel collar 368 Semi compliant balloon DCGI approved, entry tip profile 0.016,Diameter 1,1.10,1.25,1.5 to 4 mm and length 5,8 to 40mm with Nominal 6atm and RBP 14atm. Catheter length 141cm. Crossing profile 0.022 - 0.039. 369 Non compliant balloon DCGI approved, entry tip profile 0.016,Diameter 2,2.25,2.5,2.75 to 5 mm and length 8 to 40mm with Nominal 12atm, RBP 22atm,MBP>=30 . Catheter length 141cm. Crossing profile 0.029 - 0.0530. 370 Transcatheter Bicaval Try tissue valves system for Tricuspid regurgitation 371 TAVR - Aortic self expandable Transcatheter Dry Tissue technology Valve 372 180 cm length, 1.0 Tip load CTO wire for PTCA (tip shape straight), durable patented hydrphilic M Coating, with innovative duo core for a great torque response hybrid wire that fuses Nitinol & Stainless steel, 180cm and 300 cm. 373 DCGI approved Biodegradable polymer based everolimus eluting Coronary stent system with differencial stent architecture of 6 crown design for 2 - 2.75 mm , 8 crown for 3-3.5 & 10 crown design for 4-4.5 mm Length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. Diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5 374 CE approved Biodegradable polymer based Sirolimus eluting Coronary stent system with differencial stent architecture of 6 crown design for 2 - 2.75 mm , 8 crown for 3-3.5 & 10 crown design for 4-4.5 mm Length : 8 mm ,13 mm.16,19,24,29,32,37,40,44,48. Diameter : 2,2.25,2.5,2.75,3,3.5,4,4.5 375 CE/DCGI Approved Rapamycin target eluting coronary stent system with cobalt chromium platform and abluminal in-groove design and bioabsorbable polymer. Length- 13 mm,16,18,21,23,26,29,31,33,35 and 38mm. Diametre- 2.25 mm,2.5,2.75,3,3.5 and 4 mm. 376 CE approved Non complaint balloon catheter Balloon Size : 2.25mm - 5mm/Length : 6mm-20mm rapid exchange proximal shaft 2.3 F and distal shaft - 2.7 F,TIP entry profile 0.017 with Nominal inflation pressure 12 atm & RBP-20 atm,and having two plantium iridum markers. 377 CE approved semi complaint balloon catheter, inner shaft with patented 2 layer design using specialized material. Balloon Size : 1.00 mm - 4.00mm/Length : 6mm-20mm rapid exchange,proximal shaft-2.2 F and distal shaft-2.1 F,Crossing profile 0.021" - 0.027" with Nominal inflation pressure-6 atm & RBP-16 atm. 378 CE/DCGI approved Thrombus ASPIRATION CATHETER with removable core wire and 30cm hydrophilic coating from the tip; Available in 6F and & 7F. Length 145 cm 379 Transcatheter aortic valve replacement system : Self expandable system with Bovine Pericardial Leaflets and Hybrid Cell Density Frame, electrically motorised recapturable TAVI System, VITAL-X™ Anti-Calcification Technology,advanced double layer PET skirt.Effective length-112 cm,Integrated Sheath length-30 cm Diameter- 21mm,24mm,27mm & 30mm. 380 ICD Single chamber with Bluetooth Technology 381 ICD Dual chamber with Bluetooth Technology 382 ICD Single chamber with Bluetooth Technology 383 ICD Dual chamber with Bluetooth Technology 384 Permanent Pacemaker- Single Chamber ,1.5/3T Full body MRI Compatible,Bluetooth enabled,Advanced physiological rate response,Automatic Capture Management,Bluetooth based remote programming and monitoring,8cc designed with ellipsed shapes for better lead wrap and insertion,20% smaller and lighter,Battery life of up to 12-13 years, 10% improvement in energy efficiency, 15% better heart rate adjustment, 8+2 years warranty,Battery life diagnostics with 95% accuracy,35% fewer pocket related complications. 385 Permanent Pacemaker- Dual Chamber ,1.5/3T Full body MRI Compatible,Bluetooth enabled,Advanced physiological rate response,Automatic Capture Management,Bluetooth based remote programming and monitoring,8cc designed with ellipsed shapes for better lead wrap and insertion,20% smaller and lighter,Battery life of up to 12-13 years, 10% improvement in energy efficiency, 15% better heart rate adjustment, 8+2 years warranty,Battery life diagnostics with 95% accuracy,35% fewer pocket related complications. 386 Permanent Pacemaker- Single Chamber, without bluetooth device 387 Permanent Pacemaker- Dual Chamber,without bluetooth device
|