Tender For Addn/Altn To Certain Omqs And Smqs At Chaf Bangalore; 1 SCHEDULE "A" PART - I (B/R Portion)Demolition of Stone slabs and tiles laid bedded and pointed in cement mortar of any description or thickness in floors, aprons etc complete all as specified and directed. 2 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided forall as specified and as directed 3 Dismantling floor hearth or wall tiling including cement mortar bedding andbacking coat plastering of any thickness removing serviceable tiles to store and rubbish off premises etc complete all as specified and as directed. 4 Taking down cement or cement lime plaster any description on brick or stone walls, over RCC slab ,ceiling etc includingraking out joints, hacking for key, scrubbing down with water, etc.including necessary scaffolding complete all as specified and directed. 5 Material and labour forVitrified Ceramic tiles 10 mm thick, double charged (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and directed. 6 All as per Item No. 5 here-in before, but in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 10mm thick screed bed or bedding in CM 1:3 complete all as specified and directed. 7 Material and labour for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in CM 1:4 complete all as specified and directed. 8 All as per Item No. 7 here-in before, but in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 10mm thick screed bed or bedding in CM 1:3 complete all as specified and directed. 9 Material and labour for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15mm thick screed bed or bedding in CM 1:3 complete all as specified and directed. 10 Material and labour for glazed ceramic tiles coloured of size350x 250x 7 mm/ 450X 350X 7mm thickas vertical surface set and jointed in neat cement slurry and pointed in white or colour cement mixed with pigment to match the shade of the tiles complete all as specified and as directed with 10 mm thick rendering in cement mortar 1:3 for laying wall finishes complete all as specified and as directed. 11 Material and labour for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stoneincluding the like laid overcement mortar 1:4, 20 mm thick set and jointed in neat cement slurry and pointed in white cement with pigment to matchincluding grinding and polishing complete all as specified and as directed. 12 Material and labour for rounding to edges of granite/stone slab such as in steps, cooking platform and other similar situations etc complete all as specified and as directed by Engr-In-Charge. 13 Material and labour for 100 mm thick Cement concrete type B- 2, 1:2:4 (40mm graded stone aggregate)in floor finishes and paving and finishing cement concrete surface even and smooth Without usingextra cement complete all as specified and as directed. 14 Material and labour for rendering 15 mm thick on fair faces of brick works/ block works or concrete surfaces cement plaster 1:4 finished even and smooth without using extra cement all as directed. all as specified and as directed. 15 Material and labour for rendering 15 mm thick on fair faces of brick works/ block works or concrete surfaces cement plaster 1:6 finished even and smooth without using extra cement all as directed. all as specified and as directed. 16 Material and labour for rendering 5 mm thick cement plaster in cement mortar 1:3,on concrete surfaces as in ceiling/ chajja , finished even and smooth without using extra cement. 17 Material and labour for preparing new plastered surface of walls and applying two coats of cement base paint over a coat of primerthrough mechanical meanscomplete all as specified and as directed 18 Material and labour for preparing new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed. 19 Material and labour for preparing new plastered on wall and applying two coats of oil bound distemper over a coat of chalk whitening complete all as specified and directed by Engr-In-Charge. 20 Material and labour for preparing new plastered on ceilingand applying three coats of white wash complete all as specified and as directed. 21 Material and labour for preparing new plastered surface on ceiling and applying two coats of distemper over a coat of chalk whitening complete all as specified and directed 22 Supply and fixRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), triple layered, hoisted & fixed in position all as specified in SSR Part I , 500 Ltrs Capacity including dismantling existing 500 Ltr water tanks complete all as specified and as directed. 23 Supply and fix in repair ballvalves, 25 mm diabore high pressure, of PTMT with epoxy coated Aluminium rod&high density plastic ball screwed for iron pipe and fixed. 24 Supply and fix in repairs 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. 25 Supply and fix 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. 26 Supply and fix in repairstainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe , cast iron cantilever bracket , connecting union overall size 915mmX460mm with bowl size 410mm X 330mmX160mm complete all as specified and directed. 27 Supply and fix tubing, medium grade,15mm bore with all fittings fixed to walls and ceiling or laid in floors including cutting through walls and floors etc and their making good complete all as specified and directed. 28 Supply and fix tubing, medium grade,20mm bore with all fittings fixed to walls and ceiling or laid in floors including cutting through walls and floors etc and their making good complete all as specified and directed. 29 Supply and fix tubing, medium grade,25mm bore with all fittings fixed to walls and ceiling or laid in floors including cutting through walls and floors etc and their making good complete all as specified and directed. 30 Demolition of unreinforced cement concrete in floors and pavings not exc 15cm thick below or above ground level complete all as specified and as directed. 31 Material and labour for 75mm thick cement concretetype C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection all as specified and directed. 32 Material and labour for providing cement concrete type B-0 (1:2:4) using 12.5 mm graded aggregate as , in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, necessary form work allas specified and directed. 33 Supply and fix in repairs vitreous China wash basin, white flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, etc complete all as specified and directed. 34 Supply and fix in repairs 15mm pillar tap,cast copper alloy, with capstan head, chromium plated, fancy type screwed down high pressure, with or without lettered "hot" or "cold" with long screwed shank and fly nuts screwed for iron pipe of 15mm bore complete all as specified and as directed. 35 Supply and fix in repairs vitreous china squatting pan Orissa pattern of size 580 X 440mm white with integral foot rest "P" trap including connection to trap and flush pipe anti-syphonage pipe etc complete including making good to floor all as specified and as directed. 36 Supply and fix in repairs Vitreous China wash down watercloset pan (Pedestal Pattern), White with "P" or "S" trap, including provision of fixing bolts and connecting upto drain and flushing pipe etc. complete all as specified and as directed. 37 Supply and fix in repairs plastic water closet seat, white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. 38 Supply and fix in repairs PVC flushing cistern with flush out valve type,10 ltrs capacity, low level white with inlet ball valve, float and handle including bracket including flush pipe complete all as specified and as directed. 39 Supply and fix in repair PVC connection pipe 450mm long 15mm dia both end having brass coupling nut and PVC washer complete all as specified and directed 40 Supply and fixPVC connection pipe 450mm long 15mm dia both end having brass coupling nut and PVC washer complete all as specified and as directed 41 Supply and fix in repair Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1 m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect asspecified and as directed. 42 Supply and fix in repair bib taps, fancy type with chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferule of 15mm bore complete all as specified and as directed. 43 Supply and fix bib taps, fancy typechromium plated with crutch or butterfly handle screwed down screwed for iron pipe or brass ferule of 15mm bore complete all as specified and as directed. 44 Supply and fixin repairs 15 mm bore fancy type, chromium platedStop valves / Angle cock screwed down high pressure with crutchhandle screwed both ends for iron pipe or for unions all as specified and directed. 45 Supply and fix 15 mm bore fancy type, chromium platedStop valves / Angle cock screwed down high pressure with crutchhandle screwed both ends for iron pipe or for unions all as specified and directed. 46 Supply and fixin repairs 15 mm bore fancy type, chromium plated with long shank and cup (concealed type) Stop valves / Angle cock screwed down high pressure with crutchhandle screwed both ends for iron pipe or for unions all as specified and directed. 47 Supply and fix in repair 125mm dia brass chromium plated shower rose including arm with or without swivel joints including fixing to steel pipe or union complete all as specified and directed by Engr-In Charge. 48 Supply and fix in repair Brass Chromium plated fancy type towel rail, 20mm dia, D type 600mm long between flanges including brass CP brackets complete all as specified and directed by Engr-In Charge. 49 Taking up or down 15mm dia steel tubing / CPVC pipes and connections, fittings etccomplete all as specifiedand as directed. 50 Taking up or down 20mm dia steel tubing/ CPVC pipes and connections, fittings etc complete all as specifiedand as directed. 51 Supply only ISI marked integral water proofing compound 52 Cutting chases pinning in making good for Stone concrete block or slab walls to facing where required and pointing in cement mortar 1:3 to ends or edges of concealed water tubing and similar work including making good cutting n exc 10cm girth complete all as specified and as directed. 53 Supply and fix in repairs PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed. 54 Supply and fix in repairs PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints laid in floor complete all as specified and as directed. 55 Supply and fix in repairs PVC (SWR) bend withaccess door110 mm bore complete all as specified and as directed. 56 Supply and fix in repairs PVC (SWR) bend110 mm bore complete all as specified and as directed. 57 Supply and fix in repairs PVC (SWR) Branch piece single(Single Y)equal or unequal with access door 110mm bore complete all as specified and directed. 58 Supply and fix in repairs PVC (SWR) 110mm bore vent cowl complete all as specified and directed. 59 Supply and fix in repair PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-In Charge. 60 Supply and fix in repairs PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls complete all as specified and directed. 61 Supply and fix in repairs PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints laid in floors complete all as specified and directed. 62 Supply and fix in repairs PVC (SWR) 75mm bore bends any radius withaccess door complete all as specified and directed. 63 Supply and fix in repairs PVC (SWR) 75mm bore bends any radius complete all as specified and directed. 64 Supply and fix in repairs PVC (SWR) Branch piece single(Single Y) equal or unequal with access door 75mm bore complete all as specified and directed. 65 Supply and fix in repairs PVC (SWR) junction single (Single T) equal or unequal with access door 75mm bore complete all as specified and directed complete all as specified and directed. 66 Supply and fix in repairsmirror of selected quality glass 600 x450 mm size with bevelled edge mirror of selected quality glass ,mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified and directed 67 Supply and fix sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. 68 Cutting holes into or through brick walls Superficial area n. exc 150 sqcmbuilt in , cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete complete all as specified and as directed. 69 Material and labour for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate)in sub floors and finishing cement concrete surface even and rough complete all as specified and as directed. 70 Removing demolished material i.e. building material concrete debrisof any type etc to a distance of 09 KM beyond and up to 10 KMout of premises of metropolitan area including loading, unloading by manually or by mechanical means of Poclain and to be transported through trolley or tipper and staking at the destination as and when directed by Engr-In-Charge. 71 SPECIAL ITEMS OF WORK (B/R) Material and labour for mild steel Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. 72 Supply and fix welded steel wire fabric members n exc 4 kg/ Sq M cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel , fixed all as specified and as directed. 73 Material and labour for preparation of new or previously untreated steel and iron Surfaces of any description, not otherwise descri-bed, over 10cm width or girt and applying two coats of Synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and as directed. 74 HARDSTANDINGDemolition of unreinforced cement concrete in floors and pavings not exc 15cm thick below or above ground level complete all as specified and as directed. 75 Material and labour for 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded stone aggregate) as in sub floors and finishing cement concrete surface even and rough complete all as specified and as directed. 76 Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade With Grey Cement and pigment complete all as specified and as directed. 77 Material and labour for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed by Engg-in-Charge. 78 E/M PortionTaking down carefully copper/aluminiumpoint wiring (light fan socket or power) complete including fittings & fixturessuch as switches, ceiling rose, pendants, regulators, sockets, ceiling roses, pendants, regulators, light fittings etc. Removing materials to store for keeping in safe custody for taking credit and making good disturbed surfaces of walls, floors, etc. complete allas specified and as directed. 79 Taking down ceiling fansfrom ceiling, dismantling blades &refixing ofthe same includingprovision of cable from ceiling rose or connector to fan complete allas specified and as directed. 80 Taking down Exhaust Fans, from walls andrefixing the same including connecting up andprovision of cable from ceiling rose or connector to fan complete allas specified and as directed. 81 Taking down Geyserfrom walls, and handing over the same at MES store,complete allas specified and as directed. 82 Material and labour for Point wiring with cable of PVC insulated FRLS copper multistranded conductor 1.5 sqmm 1100 volts grade in and includingmedium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chassis in existing stone/ brick masonary,including fixing top cover /PVC /MS Modular type junction boxes concealed in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and as directed for the following:- 83 One lightcontrolled by 1 switch 5 amps,single pole 84 One Ceiling fan point controlled by one single pole 5 Amps switch 85 One Exhaust fan point controlled by one single pole 5 Amps switch 86 One 3 pin switch socket out let point 5 Amps switch on independent board 87 One 3 pin switch socket out let point 5 Amps switch on same board 88 One bell Pointcontrolled by one push button 5 Amps switchon independent board 89 One lightcontrolled by two nos, 2 way switch 5 amps,single pole 90 Material and labour for point wiring with cable of PVC insulated FRLS copper multistranded conductor 2.50 sqmm 1100 volts grade in and includingmedium grade 20 mm dia PVC Conduit Pipe ISI marked with all accessories and fixing arrangements concealed in Stone walls / brick masonary walls /ceilings / floors etc by cutting chases in existing stone/ brick machinery,including fixing top cover /PVC /MS Modular type junction boxes concealed in Stone walls / brick masonary walls for housing switches/sockets/ regulators etc. with and including 2.50 sqmm PVC insulated multistranded copper earth continuity conductor connecting to the common earth dolly etc complete all as specified and directed NOTE : Chases/ groove cutting shall be measured and paid separately under relevant items. 91 Supply and fix Modular switch , 1 Module single pole one way10 Amps complete allas specified and as directed. 92 Supply and fix Modular switch , 1 Module single pole one way16 Amps complete allas specified and as directed. 93 Supply and fix modular socket , 2 Module6 Amps, 2/3 pin, 240 volts Ac 2/3 pin combinedcomplete allas specified and as directed. 94 Supply and fix modular socket , 2 Module6/16Amps, 2/3 pin, 240 volts Ac 2/3 pin combined complete allas specified and as directed. 95 Supply and fix modular type fan regulator upto 120 watts with 5 step speed control for fans any sweep 1200 mm/1400 mm complete allas specified and as directed. 96 Supply and Fix modular type Bell push 6 A, 1 Module complete allas specified and as directed. 97 Supply and Fix Ding Dong Bell, AC, 230 volts, Single Pole complete allas specified and as directed. 98 Supply and fix modular white cover plate with frame, 1 module complete allas specified and as directed. 99 Supply and fix modular white cover plate with frame, 2 module complete allas specified and as directed. 100 Supply and fix modular white cover plate with frame, 3 module complete allas specified and as directed. 101 Supply and fix modular white cover plate with frame, 4 module complete allas specified and as directed. 102 Supply and fix modular white cover plate with frame, 6 module complete allas specified and as directed. 103 Supply and fix modular white cover plate with frame, 8 module complete allas specified and as directed. 104 Supply and fix metal flush box 1/2 module complete allas specified and as directed. 105 Supply and fix metal flush box 3 module complete allas specified and as directed. 106 Supply and fix metal flush box 4 module complete allas specified and as directed. 107 Supply and fix metal flush box 6module complete allas specified and as directed. 108 Supply and fix metal flush box 8 module complete allas specified and as directed. 109 Supply and fix PVC ceiling rose 65 x 50 mm surface type with 3 terminals complete allas specified and as directed. 110 Supply and fix LED Light fitting, 22 Watts, 220 volts, with driver, holder including LED tube light connecting up with 3 core flexiblecopper conductor cable of suitable size from Ceiling rose complete all as specified and as directed. 111 Supply and fix LED Light fitting, 10 Watts, 220 volts, AC decorative box type with driver, holder including LED tube light connecting up with 3 core flexiblecopper conductor cable of suitable size from Ceiling rose complete all as specified and as directed. 112 Supply and fix Sheet metal enclosures with socket plug top and MCB, Single pole & neutral enclosure with a 2 pin & earth plug & socket complete with one single pole MCB 20 amps complete all as specified and as directed. 113 Material and labour for cutting into or through the stone walls / brick wallsbuilt in cement mortar or cement lime mortar and walls of cement concrete suitable sizefor housingfor sunk box using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and directed. NOTE : Chassis/ groove cutting in stone walls/ brick wall/ block masonary walls as required for concealed wiring shall be measured and paid separately. 114 Material and labour for Cutting chassis, pinning in Stone walls/ brick walls etc.making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings etc, for concealed conduit wiring a into or through the stone walls built in cement mortar or cement lime mortar and walls of cement concrete suitable for housing 25mm dia conduit pipe using heavy duty stone drilling/cutter machine and making good the disturbed surface all as specified and as directed. 115 Material and labour for sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealedin stone wall, floor or ceiling etc by cutting chases in existing stone/ brick masonaryinc 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor, one run of PVC Conduitand two runs of copper conductor together taken as one length for measuring unit length. 116 Material and labour for sub main wiring with Two single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 6.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealedin stone wall, floor or ceiling etc by cutting chases in existing stone/ brick masonaryinc 6.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor, one run of PVC Conduitand two runs of copper conductor together taken as one length for measuring unit length. 117 Material and labour for sub main wiring with Four single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts grade 10.00 sqmm in and including suitable size of non-metallic rigid PVC conduit & accessories, fixing arrangements concealedin stone wall, floor or ceiling etc by cutting chases in existing stone/ brick masonary inc 10.00 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : Two runs of earth continuity conductor, one run of PVC Conduitand Four runs of copper conductor together taken as one length for measuring unit length. 118 Material and labour for Earthing complete with galvanised steel earth plate electrode 60x60cmx6mm thick, buried directly in ground, Putting of adequate qty of salt and Char coal in layer by layer by completely covering of earth plate on surrounding sixsides, ( earth pit not less than 2.25mtrs deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level, connected to galvanised earth lead wire 4.00 mm diaas earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point, provision of PCC earth chamber, Chamber cover, GI funnel with mesh, GI Pipe etc all as including provisionall as specified or indicted including testing on completion complete all as specified and as directed. 119 Material and labour for earth Continuity Conductor or main earthing lead fixed to wall on batten or recess or chassis or buried in ground or drawn in conduit / pipe or fixed for earthing etc. of size 4.00 mm dia galvanised iron or steel wire all as specified and as directed. 120 Supply and Fix Sheet metal enclosure for VTPN DB"s double door TPN 08ways Suitable for 125 Amps MCCB Fixed in DB, deep drawn with 200 Amps rated copper bus bar 415 V, IP 43 Protection, Concealed in walls, including taking down old unserviceable from exiting place complete all as specified and as directed. 121 Supply and fix Sheet metal enclosure for DB"s double door TPN, 8 ways when MCBs to be used single pole and neutral, deep drawn with 200 Amps rated copper bus bar 240V, Concealed in walls including taking down old unserviceable from exiting place complete all as specified and as directed. 122 Supply and fix MCB TPN, 63 Amps, 415 V, C- series with breaking capacity of 10KA complete all as specified and directed. 123 Supply and fix MCB SPN, 40 Amps, 240V, C- series with breaking capacity of 10KA complete all as specified and directed. 124 Supply and fix MCB SP, 6-32 Amps, 240V, C- series with breaking capacity of 10KA complete all as specified and directed. 125 Supply and fix MCCB 125 A, TPN, 25 KA complete all as specified and directed. 126 Supply and fix LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. 127 Supply and fix Surge protection device Type TP+N, AC Triplepole and neutral, 20kA N complete all as specified and as directed. 128 Supply and fix 1.5m length GI Pipe 40 mm dia bend L shaped for fixing of Building security lights, including properly grouting on wall with required fixing arrangements such as bolts, nuts, screws, clamps etc complete all as specified and directed. 129 Supply and Fix Geyser 25 LitresCapacity Suitable for high pressure upto 8 bar, 2 Kilowatts, 5 Star rated,Powder coated metal body, Temperature indicating dial, fire retardant cable, Efficient long life Copper heating element, Shock proof & Rust proof ABS body, including PVC Hot & Cold pipes for inlet and outlet of geyser, complete all as specified and as directed. 130 Material and labour for sub main wiring with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including heavy grade PVC conduit, surface wiring on walls and itsaccessories with fixing arrangements on pole surface, wall, ceiling etc including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and as directed. Note : One run of earth continuity conductor, one run of PVC Conduit pipeand two run of copper conductor together taken as one length for measuring unit length.
|