Temperature Sensor And Relative Humidity - Thermohygrometer With Fixation Shelter, Element Protection Sensor: Powder Filter And Weather; Reading Range: Relative Humidity: 0 ... 100% Ur; Output Signal: Moisture Between 0 And 1 Vdc = 0 ... 100% Ur, Or Sdi-12; Precision Of Moisture Sensor Reading (25ºc): Equal To +- 1, 5%Ur (0-80%Ur) And Less Than Or Equal To +- 2%Ur (80%-100%Ur); Factory Calibration Uncertainty At 20 ° C: Less Than Or Equal To 1, 5%Ur; Maximum Moisture Sensor Response Time At 20 ° C With Filter Installed: 60S; Maximum Sensor Response Time Temperature Increment With Filter Installed: & Lt; 130S; Reading Range: Temperature: -40 ...+60 ° C; Output Signal: Temperature Between 0 And 1 Vdc Or Sdi-12; Temperature Sensor Accuracy: Less Than +- 0, 3 ° C In The Measurement Range; Maximum Response Time Of Temperature Sensor Increment: 40S; Power Voltage: Between 9 And 28Vdc; Maximum Consumption Current: 10Ma; Cable Comp: 5M; Other Specifications Are In The Notice., Steering Sensor And Wind Speed (Anemometer), The Sensor Should Be Resistant To Uv, Corrosion And Rain; Wind Speed Measurement Through Helical Propeller; Temperature Operation: -20 To + 50 ° Calmentation: 9 To 15 Vcc, Wind Direction - Range: 0 To 360 ° Mechanical/0 To 355 ° Electric, Accuracy: + Or 3 °, Linearity: 0, 5 %, Output: Maximum Voltage Analog Of 10K Ohms. Accuracy: 0, 3 M/S, Output: 5 V Amplitude Pulse, Independent Of Speed, Output Frequency: 3 Cycles Per Revolution (0, 980 M/S Per Hz), Cable Length: Greater Than 12 Meters, Factory Calibration Certificate, 12 (Twelve) Months Warranty. Temperature Operation: -20 To + 50 ° C; Moisture: Without Condensation; Accuracy: Less Than Or Equal To +- 0, 5 Hpa To 20 ° C; Long-Term Stability: Less Than Or Equal To +- 1 Hpa In 1 Year; Power Voltage: 10 To 16 Vcc; Consumption Current: Up To 10Ma In 12V; Digital Output Interface: Sdi-12, Rs-232; Analog Output Interface: 0 5 Vcc; Pressure Units: Mb, Hpa, Kpa, In. Hg, Mm Hg, Atm, Psi; Maximum Dimensions: 150 Mm X 90 Mm X 70 Mm; Factory Calibration Certificate; Warranty: 12 (Twelve) Months., Datalogger - A/D Converter 24Bits Or Of Higher Resolution With Config Sampling Tx Up To 10 Hz; 4 Analog Inputs Simple Termination (0-2, 5V); 2 Differential Inputs (Up To ± 100 Mv); 2 Pulse Contacting Inputs, Configurable For Contacting Contact Closure And For Reading Sine Sine Amplitude Variable, From 80 [Mvpp] To 8 [Vpp] With 30 Khz Sampling Frequency And 0, 1 %Accuracy; Signal Signal Reading Capacity: Frequency Up To 2.5Khz, Accuracy + Or 0, 01% (Measurement + Resolution), Where 0, 013Us Divided By The Number Of Cycles To Be Measured; Minimum Pulse Width 33Ns; 1 Native Interface Sdi-12; 1 Rs-232 Native Interface With Veloc Parameters, Start Bits, Configurable Downtime Bits And Bits; Swelling Output For Sensor Power Supply (+12 V); Configurable Data Storage Interval From And 1 S Up To 24 Hours; Protocol Support: Telnet, Ethernet, Ipv4 - Other Specifications Are Contained In The Bidding Notice., 07/03/2025
|