Group Generator 260Kva - Detailed Specification In The Reference Term., Generator Group 180Kva - Detailed Specification In The Reference Term., Support Service - Detailed Specification In The Reference Term. -Detailed Expertise In The Term Of Reference. -Detailed Expertise In The Term Of Reference., Insulation Grid -Tube Isolation Grades, Measuring 2X1, 2M Each. Rental For 3 Days., Closure -Mounting And Disassembly, Being The Same In Metal Plates At A Minimum Height Of 2, 20M With Platter And Fixation Support And No Lank Tip. Rental For 3 Diarias., Panel Late With Assembly -01 P5 Led Panel At Minimum 4X3 Size And 01 P5 Led Panel In Size Of 07X05. Both With Full Structure With Full Box Installation Truss Q30 With Height Adjustment Option Up To 6 Meters Necessary, Video Processor With Several Signal Inputs For Various Use And A Professional Operator For Simultaneous Transmission With 3 Cameras At Least. Service Of Assembly Included., Rental Rental -2 Camerin Structure Location For Show, Including The 4Mx4m Seeds, In Octanm With Floor, Carpet, Air, Lining, Lighting, 3 Takens In Each Sheets -Big Symplace: Pa Line Array With At Least 3 Line Line Boxes And Drivels Each And Drivels 20 Sub Severe Boxes With Two Speakers Each, Front Fill, Debut Capable Of Reproducing 120 Dbs At Foh, With Full Coverage Of The Event, Foh Should Be At The Center Of The Stage At A Distance Of 20 To 30 Mts. Pa, With Sound Pressure To Serve Estimated Pupic In 15,000 People. Technical Specifications Should Be Informed And Attested By The Companys Electric Engineer In The Proposal, 02 Digital Tables, Pm5d Rh. 01 Equalizer I Debut 31 Bands By 1/3 Octave (Bss, Klark, Dbx). 01 Divisor Or Processor I Debut According To The System Used (Dbx Drive Rack 4.800, Xta, Dolby Lake, Or Similar. 01 4 -Point Communication System (Intercom) Indispensable. Console And Racks (Properly Lit And Covered). Monitor: 01 Console, Pm5d Rh Or Digidesign Mix Rack, Or Similar 32 Outputs, 56 Channels. Or Processor Debuts According To The System Used (Dbx Drive Rack 4.800, Or Similar. 01 Pr System. (Cue). 01 Side Fill Double Estreao (Containing: 02 Subs, 02 Medias/High On Each Side) Eaw, Clair, Or Of Assets Or Similar 03 Or 04 Roads. With 4 X 10- And 1 X 15-. 01 Fender Twin Or Similar To Guitar. Stage That Should Be Stabilized And Grounded In 127 Volts. Main Power Stabilized And Grounded The Monitor Console As Well As The Other Peripherals Should Be Mounted Outside The Stage (Stage Monitor). The System Should Be Delivered And Ready With The Clean Stage With The Minimum Of 12 Hours Before The Event, To Assemble Cenrio And Backline.
|