Supply, Delivery And Installation Of Electro-Mechanical Equipments And Other Allied Works At Runakuraghat Head Works Site Under Chotkara-Kanskuli Water Supply Scheme. Block-Barabani, District-Paschim Bardhaman.- 1 Supply, Delivery and storage at Site of specification Discharge-200 m3/Hr &Head -130 MWC Horizontal Split Casing Centrifugal Pumping Machinery with baseplate, flexible coupling, coupling guard, foundation bolt etc. withHorizontal foot Mounted Induction Motor (IE-3 type) for the pump duty mentioned above,with adequat margin.(For Clear water Pump) 2 Supply,Delivery and storage at site of Vacuum Pumping Machinary with baseplate,coupling,coupling guard,foundation bolt etc.Motor-Horizontal foot Mounted Induction motor-2.2KW/3 HP for the vacuum pump duty mentioned above with adequate margin. Vacuum:upto 600 mm of Hg. Air Flow Rate:upto 55 m3 / Hr. 3 Supply, Delivery and storage at site of Submersible dewatering Pumping Machinarywith baseplate, coupling, coupling guard, foundation bolt etc. Motor submersible type 3 phase, 415 Volt, 50 Hz.2.2KW/3 HP.Discharge :- 202 LPM Generated Head :-20M 4 Supply, delivery and storage at site of follwing dia manually operated CIDF Rising type Sluice Valve as per IS:14846 PN-1.0. 5 300 mm dia Sluice Valve.(FOR SUCTION SIDE OF CLEAR WATER PUMP) 6 Supply,delivery and storage at site of following dia CI wafer Single Door Swing Check N.R.V with by-pass arrangement as per IS : 5312, Part-I, PN-1.6. 7 250 mm dia NRV.(FOR DELIVERY SIDE OF CLEAR WATER PUMP) 8 Supply, delivery and storage at site of following diaC.I. Double flanged type Actuator operated Butterfly Valveas per IS 13095, and disc conforming to IS:210 ,PN-1.6.(Test Certificate,Waranty certificate to be submittered for each valve at the time of delivery) 9 250 mm dia.(FOR DELIVERY SIDE OF CLEAR WATER PUMP) 10 Supply, delivery and storage at site of following diaCast Iron kinetic double orifice air released valve as per relevant IS, PN-1.6. 11 80 mm diaP.N-1.6.(CLEAR WATER) 12 Supply,delivery and storage at site offollowing dia. MS Dismantling joints with Rubber compression Ring and adjustable follower flanged complete assembled unit with galvanized stud and nuts. 13 300 mm dia Dismantling Joint PN-1.0. (AT SUCTION SIDE OF CLEAR WATER PUMP) 14 250 mm dia Dismantling Joint PN-1.6.(AT DELIVERY SIDE OF CLEAR WATER PUMP) 15 Supply, delivery and storage at site offollowing 150mm dia Glycerine filled Diaphragm Seal type Gagues with syphon tube and three way cock. (Make - H.Guru) 16 Pressure Gauges (0-16 kg/ cm2)(1 NO FOR DELIVERY SIDE CLEAR WATER PUMP) 17 Compound Gauges (+1-1 KSCG)(1 NO FOR SUCTION SIDE OF CLEAR WATER PUMP) 18 Supply, Delivery and Storage at site of 250 mm, 300 mm MS black Pipes (For suction and delivery, individualSuction & DeliveryPump under Sl No-1 along with necessaryBends, fittings viz. flanges, bolts, nuts, gaskets,eccentric reducers 300 mm x 150 mm, concentric enlarger 125 mmx 250 mm, as reqd. to make the installation complete in all respect. 19 Supply, Delivery and storage at site of Radar type Level Transmitter Unit for CWR with provision of Power Supply (Output, Operation): 2-wire; 4-20mA HART; HART/Bluetooth (App) configuration, inicator and remote display unit for continuous level monitoring with relay output for sensing high, low level in suction side of pump with surge protection and display unit (Relay with Surge Protection with Panel mounting 96 mm x 96mm. LPS = Loop power supply 7 digital LCD-display). (Level range-80mm-8mtr, liquid) (Along with 50 m cable) 20 Supply, Delivery and Storage at site 40 mm dia, G.I.Pipes (medium duty), Bends,sockets, Tees,fittings, and other specials,gasketsetc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect. (For priming arrangement) 21 Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt PDB cum MCCPanelhaving required Feeders.(175 HP S/D Starter-2 Nos + 7.5 KW/10 HP-10 Nos) 22 Supply OF 400 Amp, 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc, spacious sheet steel enclosure, separate cable gland box not required, terminal shrouds on both sides and phase barriers included, conforms to IEC 60947-3, IS/IEC 60947-3, suitable for DIN fuse-link, door interlock & padlock facility incl. S & F 3 nos. DIN type HRC fuse-400 Amps rating.(Make-L & K, FN 400 TPN, Cat No-SK90491+Fuse Unit Cat No-SF94435/ Other approved make)(In Pump House) 23 Supply & delivery of Full Bore type Electro-Magnatic Flow Meter with meter protection panel as well as Cable between Sensor and Transmitter on Delivery Rising main line. 24 250 mm dia delivery main line. 25 Supply, Delivery and storage at site 3 core 1.1 KV Grade following Al. Ar.XLPE insulated Cable. 26 3 Core X 185 Sqmm cable.(For MCC Panel to individual clear water Induction Motor.) 27 Supply, Delivery and storage at site3½ core 1.1 KV Grade 300 Sq. mm. XLPE insulatedAl.Ar Cable.(FROM EXISTING LT MCC BUSBAR TO SFU TO NEW LT MCC) 28 Supply, Delivery and storage at site 3 Core X 6 Sqmm cable 1.1 KV Grade XLPE insulatedAl.Ar Cable.(For MCC Panel to Vacuum + Dewatering induction motor) 29 Supply, Delivery and storage at site3 Core 1.1 KV Grade 4.0 Sq. mm. XLPE insulated Copper Ar Cable. (ForMCC Panel to individual valve actuator for clear water) 30 Supply,Delivery and storage at site12core 1.1 KV Grade 1.5 Sq. mm. XLPE insulated Copper armoured control Cable. (For MCC Panel to individual valve actuator.) 31 Supply, Delivery and storage at site 8 Core 1.1 KV Grade 1.5 Sq. mm. XLPE insulated Copper armoured control Cable. (For Highlift Pumping Machineries) 32 Earthing & lightning protection arrangement for Pump house, Chlorine room and electrical installation as per ISS and IE rules.(Earth Pit 4 Nos) 33 Supply, delivery at site and storeage of GI perforated cable tray at Pump house for laying of incoming & outgoing power and control cables to and from MCC Panelhaving proper M.S. structural support as per specification and direction of EIC. 34 Supply, delivery and storage at site 2 mm thick CRCA Sheet steel enclosed Local Push Button Switch for the following equipments: 35 High lift Pumping Machineries.(Indoor type) 36 Earth work in excavation of Cable line trenches, in all sorts of soil including removing, spreading or stacking the spoils within a lead of 75 m. as directed &filling the same with excaveted soil including ramming dressing after all complete. The item includes necessary trimming the sides of trenches,levelling,dressing and ramming the bottom,bailing out water as required complete.Depth of excavation not exceeding 1,500 mm. 37 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 38 (i)Single brick flat soling of picked jhama bricks, including ramming and dressing bed to proper level and filling joints with local sand. 39 (ii)Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. 40 (iii)Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth 41 Reinforcement with 10mm dia MS rod for reinforced concrete work in all Sorts of Structures including distribution bars,stirrups,binders etc initial straighting and removal of loose rust(if necessary) cutting to requisite length,hooking and bending to correct shape ,placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(make-SAIL/IRNL and other approved make)(For Slab Reinforcement). 42 (iv)Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off of chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary.(ii) With 1:4 cement mortar, 20 mm thick plaster 43 (v)Net cement punning about 1.5mm thick in wall, dado,floor etc. 44 (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement offinished quantity)(B) Do - by fine sand. 45 Laying of 200 mm dia DI pipe, 20 feet length, after cutting concrete/earth and removing dedris, then placed it in proper position, in between road end, then end fixed by using brick work, next repairing the road by orinary cement concrete, and all RBTWs cable from Low lift run through this pipe so no chance of damaged all work should be done as per direction of EIC. 46 Installation of all items as mentioned in Sl.No. 1 to 24 of PART-A excluding Item No-22 including construction of Pump foundations, pipe supports, valve supports, flow meter installation, level indicator installation, laying of cables through the masonry trench, with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installationas per Hydraulic standard & IE rules in compliance. 47 Painting of the installation (viz. pumps frame ,valves, pipe lines etc.by two coats of epoxy paint (colour to be decided by EIC) over a coat of primer. 48 Testing & Commissioning of the entire installation i.e. Pumps, Motors,valves etc. as in PART-A as per direction and to the entire satisfaction of E.I.C. 49 Add GST @ 18% 50 Add CESS @ 1%
|