Supply, Fitting And Fixing Of Different Electrical Items And Electrical Wiring In Poultry Farm At Wbcadc, Ranaghat-Ii Project Premises--1. (a) Supplying and fixing Sheet steel Main Switches on flat iron frame on wall. 415 V, 16 A, TPN with fuse on L&N. (Havells) 240 V, 15 A, DP with fuse on L&N. (Havells) 2. Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars, 415 V, 63 A, 4x20x5mm, 500mmx150mm 3. Supplying of following XLPE Insulated Aluminum Conductor armored cables of 1.1 KV grade as per IS 7098 (Part-I) : 1988 with up to date amendments. (a) 4 Core 10 Sq.mm Cable. 4. Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, including S & F with earthing attachment in 2 x 10 SWG GI (Hot Dip) wire, making hole etc. as necessary with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 5. Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below:- (c ) For 4 Core, 10 Sq.mm Cable. 6. Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 10 Sq.mm Cable. 7. Supplying and fixing double-door Horizontal TPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 Way (Havells) 8. Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. (a) 32A FP (Havells) (b) (6-32 A) SP (Havells) 9. Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC 10. Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 2 Row 18 Module 11. Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required 12. Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish (a) On Board. [2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC] 13. Supply & Fixing 240 V, 16 A, 3 pin Modular type plug Socket (Brand approved by EIC), with 16A Modular type switch, without plug top on 4 Module GI Modular type Switch board with top cover plate flushed in wall incl. S&F Switch board and cover plate and making necy. Connections with PVC Cu wire and earth continuity wire etc. 14. Supplying & Fixing GI waterproof type looping cable box size 200x 150x 100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint. 15. Supply and fixing of smart bright street light (36 Watt) complete with all accessories to be fixed/projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required S&F 40 mm GI Pipe (ISI-Medium) quality 1.5 mts. Average length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connection as required and mending good damages to wall incl. painting etc. 16. Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:- By ISI-Medium GI pipe. 17. Supply & fixing of angular batten holder of anchor make for B22 lamp including necessary required materials. 18. Supply & fixing of 9W B22 LED Warm White/ Yellow Bulb , 3000K, 1480 lm of existing holder including necessary connection. 19. Supply 7 fixing of penden holder complete with aluminium lampshade of anchor make for GLS lamp including S&F of 200W B22 GLS Bulb and necessary required materials. 20. Supplying of approved make high speed ceiling fan (ISI Marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackles, Aluminium blades, without regulator, A.C. 230-250 Volts. 1200 mm 21. Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
|