Tender For Supply/Installation/Testing/Comissioning Pumping Set And Other Works For U.G.R In Sector-32A Yea Wc-(E M-02) - Boosting Pumping plant Supply & Fixing of horizontal split casing centrifugal pump set with C.I. impeller coupled through a flexible tyre type coupling to sq.cage induction motor with 1440 rpm suitable for operation on 440volts, 3 phase ,50 hz A.C. supply, mounted on a common M.S. channel iron base plate including pdg foundation nut bolts, washers etc. Complete as per direction of E/I.The pump shall be suitable to perform the following duties:-(Make : KIRLOSKAR/A.B.B/C.G) Model:-UP150/38B Discharge :- 120LPS Head :-28 Mts. Liquid :- Clear Water Capacity :-75 HP 2 Supply and fixing of 75 H.P.fully AutomaticControl Panel with star-delta starter for submersible pump sets / VT/Booster Pump set with following features No-volt, Under-voltage,Over -voltage protection,microprocessor based overload protection, Unbalancing protection ,winding tempreture controller ,seal monitor, reverse rotation trip device and the automatic start/stop device according to the levels in the sump. The control panels are provided with normal indications such as Digital voltmeter, Digital Ammeter, and indicating lamps,Above panel is dust and vermin proof made out of 14 SWG CRC sheet with powder coating paintas per directions of E/I. 3 Supply/Erection/Testing/Commisioning of Cubical type LT panel Board made out of 14 S.W.G. CRCA sheet steel encloser floor mounted on M.S.chanel with suitable size of Al.bus bar following confrigration i/c complete connection etc.As per Drawing. i.) 1600 Amp. ACB-3 Nos. ii) 800 Amp.MCCB - 2 Nos. iii) 250 Amp. MCCB -8 Nos. iv) 100Amp.MCCB -6Nos.v) Indicating lamp with HRC fuse-1 Set. vi) 14 nosAmp.Meter,2 nos volt meter -2 nos C.T-150/5,250/5,800/5,1600/5 vii)18 nos A.S.S & 2nos V.S.S. 4 Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI ,Gloster , Asian , Universal , Nicco , ICL , Diamond, Havells & KEImake] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga , Suraj, Delton, Grandly, Polycab & KEI make can be used) complete in all respect as per the directions of the Engineer-in-chargePWD-2018/PS No-501 5 i.) 150 sqmm 3-1/2 core 6 ii.) 400 sqmm 3-1/2 core 7 Supply and fixing of Flat cable for starter to Motor 35 sqmm x 3 core 8 Supply & fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, making connections etc. complete in all respects as per direction of the Engineer-in-charge. PWD-2018/PS No-504 9 i.) 400 sq.mm 10 ii.)150 sq.mm 11 iii.) 70 sq.mm 12 iv.) 50 sq.mm 13 Supply and fixing of flanged type C.I.foot valve.(Make:Kirloskar/IVC) i) 300 mm dia 14 Supply and fixing of reflux valve upto 600 mm dia shell confirm to IS: 5312 PART -1 and above to IS :5312 Part-2 with latest amendment,valve shall be in graded CI with metal to metal (IS 318 Gr. LTB 2) Seating,preferably slanted (and not perpendicular) vis-a-vise horizontal asix ; SS AISI 410 stub pins & slant seat designwith complete component & material of construction following below:- 1-Body/Door/Dome-Cast ironJS 210 Gr FG 260 2- Hinge pin (single door)/stub pin (multidoor type) SS AISI 410 3-Seat and face rings- Gun metal:IS318 Gr. LTB 2 4-Rivets-soft annealed brass 5-Fasteners-Carbon steel 6-Flanged drillingIS 1538 Tnble 4 7- PN-1.0 8- By pass arrangement-Optional 9- Painting/coating inside & outside epoxi liquid coated 10- Hydro test seat;-10/16 kg/cm2 15 i) 350 mm dia 16 ii) 500 mm dia 17 P/F Sluice valve Shall generally comform to IS 14846 with latest amendment , with length over flanges as per PD of IS 14846 corresponding to BS EN-558 / ISO 5752 Basic Series 3 in CI Construction having metal seating (IS 318 Gr. LTB 2) with complete Component & Material of construction following below.1 - Body / Door / Dome - Cast Iron IS 210 Gr. FG 260 2 - Spindle - Non rising ; Stainless Steel AISI 410 3 - Body seat / Door face -Gun metal IS 318 Gr. LTB 2 (rings to be prss fitted and riveted, no screw allowed) 4 - Rivets - Soft annealed brass 5 - Spindle Nut - Gun metal IS 318 Gr. LTB 2 6 - Stem seal - Greased Hemp 7 - Fasteners - Carbon steel 8 - Flange Drilling - IS 1538 Table 4 & 6 9 - PN 1.0 10 - Accessories (400 mm and above) - Ball thrust bearings to be housed above the wet chamber ie above the gland.Enclosed spur Gear Box for ease of operation. Air Plug.11 - Painting / Coating - Inside & Outside epoxy liquid coated ; DFT minimum 250 micron, shade RAL 5005 /5015 (BLUE) 12 - HYDRO -test - (Open ended only) seat : 10 / 16 Kg/Cm2; Body : 15 / 24 Kg/cm2 13 - Upto 600 mm dia Manual Operated & above 600 mm Gear Box Make- Indian valve Pvt. Ltd. (IVC)/ Kirloskar Brothers Limited (KIRLOSKAR) 18 350 mm dia 19 500 mm dia 20 Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.PWD-2018/PS No-1136 21 Supply and fixing of fire extinguisher,ABC type 9.00 kg. capacity (ISI marked IS : 15683 & TAC approved ) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.PWD-2018/PS No-1132 22 Supply and laying of 25mmx3mm G.I. strip from earth electrode directly in the ground as required complete in all respect as per the directions of the Engineer-in-charge PWD-2018/PS No-710 23 S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. complete in all respect as per the directions of the Engineer-in-charge. PWD-2018/PS No-702 24 P/F M.S. Specials such as Tee ,bend,collors, pipe,tail piece etc in required thick of m s sheet complete in all respect as per direction by the E/I.UPPWD-SOR-2020 CIVIL 25 Earth work in excavation over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm. on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m: disposed earth to be leveled and neatly dressed : a) All kind of soil.UPPWD-SOR-2020 CIVIL 26 Constructed masonary chamber of 120x120 x100 cm insidewith 100 class degi. Bricks in cement mortar 1:5 (1 cement:5 c sand) for sluice valveC I surface box 1`00 mm top dia.1`60mm bottom dia. 180 mm deepwith R C C top slab 1:2:4 (1 cement :2c.sand:4stone agg. 20 mm ns)necessary excavation ,foundation concrete 1;5;10 (1cement :5 c sand :10 stone agg. 40 mm ns)inside plaster of cement mortar `1:3 (1 cement :3 c sand) 12 mm thick finished with a floating coat of neat cement complete as per standred design with F P S bricks. UPPWD-SOR-2020 CIVIL 27 Brick work with FPS bricks of class deg.150 in foundation and plinth in cement mortar 1:4 (1 cement :4 c. sand) UPPWD-SOR-2020 CIVIL 28 12 mm thick cement plaster of mix 1:3 (1cement :3 c sand)with a floating coat of neat cement. UPPWD-SOR-2020 CIVIL 29 P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level 1:4:8 (1 Cement : 4 C. Sand : 8 graded ston agg. 40 mm N.S.) UPPWD-SOR-2020 CIVIL 30 P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level 1:2:4 (1 Cement : 2 C. Sand : 4 graded ston agg. 20 mm N.S.)UPPWD-SOR-2020 CIVIL 31 Steel work welded in builtup section/frame work I/c cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel eyc. As required. In grating,frame ,guarders, ,radders, railings, bracket,Gate and similar works.UPPWD-SOR-2020 CIVIL 32 Pump House for Booster Earth work in excavation in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm. on plan.) including dressing of sites and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil. UPPWD-SOR-2020 CIVIL 33 P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level 1:4:8 (1 Cement : 4 C. Sand : 8 graded ston agg. 40 mm N.S.) UPPWD-SOR-2020 CIVIL 34 Brick work with F.P.S.bricks of class designation 100 in foundation and plinth in; cement mortar 1:4 (1cement:4 C.Sand) UPPWD-SOR-2020 CIVIL 35 P/L Damp Proof Course 40mm thick with cement concrete 1:2:4 (1 Cement ; 2 C. Sand : 4 graded stone agg. 12.5mm N.S.) UPPWD-SOR-2020 CIVIL 36 Brick work with bricks of class designation 100 in super structure above plinth level up to floor V level in all shape and sizes in cement mortar 1 : 4 (1 cement : 4 coarse sand ) UPPWD-SOR-2020 CIVIL 37 12mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) UPPWD-SOR-2020 CIVIL 38 15mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 c. Sand).UPPWD-SOR-2020 CIVIL 39 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick 20 mm N.S stone agg.UPPWD-SOR-2020 CIVIL 40 P/F factory made ISI marked steel glazed doors, windows and ventilators, side /top/ centre hugh with beading and all mambers such as K11 B and K-12 B etc. complete of stamdard rolled steel sections, joint metered and flash butt welded and sash bars tenoned and riverted with 15x3 mm lugs ,10 cm long ambeded in cement concrete blocks, 15x10x10 of 1:3:6 ( 1 cement :3 c sand :6 stone agg 20 mm n.s. ) or with wooden plugs and screw or rawl plugs and screw or with fixing clip or with bolts and nuts as requiredincluded P/F of hinges ,piovts ,float glass panes with glazing clips and special metal sash, putty of approved make complete including applying a priming coat of approved steel primer including the cost metal, beading and other fittings except necessary hinges and pivots complete as per approved design.UPPWD-SOR-2020 CIVIL 41 R.C.C. work in beams, suspended floors, roofs having slope up to 15°, landings balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases up to floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2C. sand : 4 graded stone agg. 20 mm N.S.) UPPWD-SOR-2020 CIVIL 42 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete: cold twisted bars UPPWD-SOR-2020 CIVIL 43 Centring and shuttering including strutting, propping etc. and removal or form for:(Ino-5.9/ Pno-89) Suspended floors, roofs, lending balconies and excess platform. UPPWD-SOR-2020 CIVIL 44 Lintels, beams, plinth, beams girders, bressumers and cantilevers. UPPWD-SOR-2020 CIVIL 45 Painting with synthetic enamelpaint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. UPPWD-SOR-2020 CIVIL 46 Finishing wall with water proofing cement paint of required shade. New work (Two or more coats applied 3.28 Kg/10cm2) UPPWD-SOR-2020 CIVIL 47 Distempering with dry distemper of approved brand and manufacture( Two more coats) and of required shadeon new work,over and I/c priming coatof whiting to give anevenshade.UPPWD-SOR-2020 CIVIL 48 White washing with lime to give an even shade : New work (three or more coats ) UPPWD-SOR-2020 CIVIL 49 Providing gola 75x75 mm in cement concrete1:2:4 (1cement :2C. sand :4 stone agg. 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement: 3 F. sand) as per standard design in 75x75 mm deep chase.UPPWD-SOR-2020 CIVIL 50 Making khurras 45x45cm with average minimum thickness of 5cm cement concrete 1:2:4 (1 cement :2 C. sand:4 graded stone) agg. Of 20mm N.S.)over PVC sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1cement:c. sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete.UPPWD-SOR-2020 CIVIL 51 Providing and fixing on wall faceunplasticised-Rigid PVCrain water pipes conformingto IS: 13592 Type A including jointingwith seal ringconforming to IS: 5382 leaving10 mm gap for thermal expansion. (I) Single socketed pipes-110 mm dia UPPWD-SOR-2020 CIVIL 52 Providing and fixing on wall faceunplasticised- PVC moulded fittings/ accessories forunplasticised-RigidPVC rain water pipes conformingto IS: 13592 Type A including jointingwith seal ringconforming to IS: 5382 leaving10 mm gap for thermal expansion.(I) Bend 87.50-110 mm dia UPPWD-SOR-2020 CIVIL 53 Providing and fixing unplasticised- PVC pipe clipsof approved design to unplasticised-RigidPVC rain water pipes by means of 50x50x50 mmhard wood plugs, screwed with MS Screws of required lengthincluding cutting brick workand fixing in cement mortar . 1:4 ( 1 cement :4 c sand ) and making good thewalletc complete. 110 mm UPPWD-SOR-2020 CIVIL 54 Steel work welded in builtup section/frame work I/c cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel eyc. As required. In grating,frame ,guarders, ,radders, railings, bracket,Gate and similar works.UPPWD-SOR-2020 CIVIL 55 6 mm cement plaster to ceiling of mix: 1:3 (1 cement : 3 fine sand) UPPWD-SOR-2020 CIVIL 56 P/L in position Cement Concrete of specified grade excluding the cost of centering and shuttering – all work up to plinth level 1:2:4 (1 Cement : 2 C. Sand : 4 graded ston agg. 20 mm N.S.) UPPWD-SOR-2020 CIVIL 57 Neat cement punning. UPPWD-SOR-2020 CIVIL 58 Internal Electrification Work Supply & erection of Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. d) 410 SP-55, 11mtr. (Approx. wt. 232kg.) YEIDA SOR-24 59 S/F of cross arm made of 100X50X6 mm M.S. channel 2.5 mtr. long on poles with packing, piece, M.S. clamp, Nut bolts etc. complete in all respect, as directed by Engineer in charge YEIDA SOR-30 60 S/F of cross arm made of 100X50X6 mm M.S. channel 1.15 mtr. long with M.S. clamp packing piece Nut bolts etc. complete in all respect, as directed by Engineer in charge YEIDA SOR-31 61 Supply, Sagging, tensioning, jointing and bending of suitable size ACSR conductor conferming to I.S. specification including cost of aluminium wire and jointing sleeve required. The rates includes cost of material, labour, T&P etc. required for proper completion of work as per the directions of the Engineer-in-charge. PWD-2018 P.S.-627 Dog Conductor. 62 S/F of 11 KV Polymeric pin insulator with pin on poles or anywhere specified including bolts to fasten on pole cap/cross arm with the poles.(Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-78 63 S/F of 11KV Polymeric Disc with Gun fittings on cross arms/clamps fixed on poles including all Nut, bolts & washer etc. (Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-79 64 S/F of 11 KV TPMO set of ‘Relco’ make or equivalent with insulators and other accessories required for proper completion of work.as per the directions of the Engineer-in-charge YEIDA SOR-56 65 S/F of 11 KV Drop-out type fuse set channel type of ‘Relco’ or equivalent make with insulators and other accessories required for proper completion of work.as per the directions of the Engineer-in-charge YEIDA SOR-57 66 Supply, Testing and Commissioning of out door type 630 KVA Transformer copper. wound. 11 / 0.433 KV ratting three phase double bound with Copper winding voltage ratio 11000/433-250 volts, vector group dry air cooled with manualy operated 5 % & 10 % off load charges & cottege with standerd fitting & accessories and also conferming to IS 1180 with fresh filling of the oil complete as required of appruved marked I/c making plinth for installation in cement concrete as per direction of E/Iand drawing (Crompton,NGEF,Alostom,BHEL,Voltamp,Diamond,Reychem,Kanohar make).YEIDA SOR-74 67 S/F of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 Mtr. below ground level complete with 20 mm dia G.I. pipe & funnel for watering & one earthing lead of one no. 8 to SWG GI wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of GI pipe and GI wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of char-coal/coke & salt atleast 150 mm thick all-around etc. complete in all respect as per the directions of the Engineer-in-charge. PWD-2018/PS No-702 68 Supply and laying of 25mmx3mm G.I. strip from earth electrode directly in the ground as required complete in all respect as per the directions of the Engineer-in-charge PWD-2018/PS No-710 69 Supply, delivery, laying testing & commissioning of 11KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semi conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 11 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. (CCI (Bombay/Nashik), Fort Gloster (Calcutta / Baripara), Asian (Thane / Silvasha), Universal (Satna), Nicco (Calcutta), ICL (Rajpura), Diamond, Havells make PWD-2018 P.S.-506(a) 3CX120 Sqmm. 70 Supply, Installation, Testing & Commissioning of 11 KV Out door type cable termination kit of 3 core cable with cable termination at the panel & transformer complete in all respect as required for proper completion of work as per direction of Engineer-in-charge.(Make Raychem/C.C.I./Frontec) YEIDA SOR-5i) 3CX120 Sq.mm. 71 Supply, Installation, Testing & Commissioning of 11KV, indoor type cable termination kit of 3 core cable with cable termination at the panel & transformer complete in all respect as required for proper completion of work as per direction of Engineer-in-charge.(Make-Raychem/C.C.I./Frontec) YEIDA SOR-4 i) 3CX120 Sq.mm. 72 Supply and fixing fo LED Tube Light with Batten Suitable for up ti 1X22 watt LED Tube Light Fitting including tube on Surface completed in all respects. PWD-2018/PS No-1413 Catt - AAA 73 Construction of Boundary Wall in brick work with cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) for chain link I/c cement plaster 1 : 4 ( 1 cement : 4 coarse sand ) and finishing with water proofing cement paint complete as per drawing and direction of Engineer in charge. E-75 74 S/F fencing 2.70 m. height chain link 2 x 2 of 10 SWG wire intermediate or a iron upright of size 50 x 50 x 6 mm. Complete with longitudinal angle iron of size 50 x 50 x 6 mm. And M.S. flat 25 x 5 mm. In each section with nut & bolts etc. as per direction of E/I and attach drawing i/c grouting of angel iron in cement concrete 1 : 2 : 4 and provision of gate/door complete in all respect.E-56 75 Supply and erection of overhead line with GI wire on 8 to 4 SWG on poles/service bracket including binding etc. complete in all respects.PWD-2018/PS No-628 76 Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.piano type switch and ceiling rose/angle/ batten holder on 3 mm. thick phenolic laminated backelite sheet etc. complete in all respect, as directed. Complete in all respects PWD-2018/PS No- 121C 77 Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm. FRLSH PVC insulated multistrand single core copper conductor cablePVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit., piano type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc,complete in all respect. PWD-2018/PS No- 123C 78 Wiring Point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. , GP Box and piano type switch and socket etc. complete in all respect. P.S No 124C 79 Wiring point for H.P.M.V./ Sodium Vapour lamp with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , and 15 A piano type switch etc. complete in all respect.PWD-2018/PS No-126C 80 S/W of submain with 2 Nos. 4 sq. mm FR PVC insulated 1100 Volt grade multistrand single core copper cunducter cable. In 20 mm dia heavy duty (2mm thick) PVC conduit with one no. 2.5 sq. mm FR PVC insulated multistrand copper conducter cable as earth contunity wire drawn in counuit. Complete in all respects as per PWD-2018/PS No-216C 81 Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. E/I DSR Electrical-2018. 12.38 82 S/F of GI pipe bracket 1.5 dia 1½ mtr long suitable for SV fitting complete with clamp made of 50x6 mm MS flat & 6 sq. mm 2 nos Al. Conductor cable duly complete connection etc... complete in all respects as per direction of E/I (AOR) 83 S&F of 100 A. 415 V Metal clad TPN CFS complete with HRC fuse etc. on angle iron frame complete in all respect. 84 S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve PWD-2018/PS No-1002 CAT-A 85 S&F of 40 Amp. DP MCB (10 KA) C Curve PWD-2018/PS No- 1010 CAT-A 86 S & F surface/Flush mounting 12ways SPN distribution board without additional metal door without MCB complete in all respect, as direct by Engineer in Charge. PWD-2018/PS No-1025 CAT-A
|