Supply, Delivery, Fabrication, Modification, Installation, Testing And Commissioning Of Electro-Mechanical And Instrumentation Work At Existing 48 Mld Raw Water Pump House For Water Supply Scheme Of Bally Municipality, Howrah.- 1 Supply, Delivery of Spare parts for 1100 cu.m/hr at a Head of 15 m VT Pump set with all req. accessories as per technical specification and direction of EIC. 2 Providing, lowering, laying, aligning, fixing in position in pipe line,Resilient Seated D/F DI Butterfly valves. (Electrically Operated PN 1.0) 3 DN 500 mm 4 DN 800 mm (common menifold) 5 Providing, lowering, laying, aligning, fixing in position in pipe line,Resilient Seated D/F DI Sluice valves with bypass arrangement. (PN 1.0) class) 6 DN 500 mm 7 Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Non Return Valveof approved make with bypass arrangement. 8 DN 500 mm 9 Supplying including cost of installation of D.I. Dismantling Joints with available length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece. 10 DN 500 mm 11 DN 800 mm (common menifold) 12 Supply, erection, testing & commissioning of 500 mm Electrical Actuator for BFV. . 13 Supply, erection, testing & commissioning of Gear Box for 500 mm Electrical Actuator of BFV. 14 Providing, Installation, Testing and Commissioning of Electromagnetic Flow Meter of 800 mm dia. 15 Supply & fixing of Pressure Gauge with allied acessories. 16 Supply & fixing of Pressure Transmitter with allied acessories. 17 EARTHING SYSTEM as per direction of EIC and following the approvedspecification asdetaied below. 18 Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. 19 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe. 20 Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 21 Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 22 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size 8 SWG on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 23 Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 Volt,300 mm sweep RPM 900/1400(12") 24 Supply , delivery and Installation of safety equipment 25 Supply, Delivery and installation of Co2 type fire extinguishers: 6.5 Kg capacity with ISI marked Co2 type fire extinguisher Each 12177.00 squeeze grip type conforming to IS:15683:2006 made from seamless cylinder conforming to IS:7285 duly approved by Chief controller of explosive, Nagpur, fitted with ISI marked controller of explosive, Nagpur, fittet with ISI marked controlled valve conforming to IS:3224, high pressure 1 mtr. long discharge hose and horn complete with initial gas charged mounted on trolley wheels. 26 Fire buckets with stand (2 buckets and 1 stand) 27 Supply, and fixing of insulation rubber Mat of following sizes:2.0 mm thick (upto 11 KV) 28 Shock treatment chart 29 First aid box 1nos. with Medicines 30 Supply , delivery and Installation ofGlow Sign Board as per detailed specification and as perdirection of EIC. 31 Illumination of Pump House & Panel room including Double door Horizontal TPN MCBand MCB ( 6A , 32A and 40A ). supplying fitting, fixing all complete 32 Supplying and fixing of philips smart bright extra 4ft run length LED batten tubelight,40 W,220v,50hz. 33 Supplying and fixing of Smart Dura bay prime light,100 W 220v,50hz with all acceseries. 34 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. 35 4M 36 6M 37 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switchboard having top cover plate and making necessary connections as required. 38 Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required. 39 Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 40 Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 41 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] 42 Average run 5 mtr 43 Average run 8 mtr 44 Average run 10 mtr 45 Distribution wiring in 1.1 KV single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required.2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC 46 Cost of Terminationwith different sizescables/ wire etc . 47 Out door iilumination for compound lighting including supply and fixing all complete. 48 SITC of Environmental friendly, energy saving long life corrosion resistant vertical/horizontal surface mounting pressure die-cast aluminium well glass luminaires with high power LED as light source (ENDURA WELL GLASS NEOT SS 26 W LED 75 7S PCS) 49 SITC of Saucer Neo Energy saving, environment friendly & robust Highbay/Mediumbay LED IP65 luminaire with high efficacy. 50 S &F of of 3Cx2.5 Sqmm. Copper armour cable 51 Supply and delivery at site of 1.1 kv grade 2 core 6 sq.mm/ 5 core/ 7core /1.5 /2.5 Cu .signal cable as per site requirement . XLPE insulated A1. Ar. Cable confirming to IS : 7098 (Part - I) 1988 for outdoorlighting along with manufacturestest certificate [ Make: Gloster / Havells / Polycab /PHED approved ] 52 Laying of 1.1 KV Gr. 2 core 6 sq.mm XLPE Armored Alu. Cable in underground trench 460 mm wide x 760 mm average depth, with brick protection onthe top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 53 Laying of 1.1 KV Gr. 2 core 6 sq.mm XLPE Armored Alu. Cable(make-GLOSTER/HAVELLS/FINOLEX) on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as directed by EIC. 54 Supply fixing of smart essential street light 70W complete with all accessories to fixed/projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI medium) quality1.5mts avg length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. (Make: Philips) 55 Supply fixing of smart bright street light 36W complete with all accessories to fixed/projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI medium) quality1.5 mts avg length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. (Make: Philips) 56 Earthing with 1 no. of G.I. earth spike ( 20 mm dia X 1.5 mtre. Long ) drivenintothe ground upto 2 mtr. Drawing earth lone with separate 6 SWG . G.I. Wires providiing 15 mm dia G.I. pipe protection from earth spike feeder bos / junction box / poles andfixing to the same by suitable nuts & bolts all comete as per direction of EIC. 57 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primerofapprovedmake, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. 58 (a) Upto 9.0 mtr. long pole 59 (i)One coat of red lead/Zinc chromate priming 60 (ii)1st coat of synthetic enamel paint over the primer 61 (iii)2nd coat of synthetic enamel paint over the 1st coat 62 Dismantling Charges of all existing Equipments as required (Removed Materials shall be carried to departmental stack yard within distance of 25 km from the project site and stacked as per the direction of EIC in charge)
|