Scaffolding - Tubular 1, 00X1, 50, 60Mts, Minimum Of 08 Steps, Accents With Finishing, Tubular Metal Structure, With Awning Coverage, Four Access Stairs With A Minimum Width Of 2M And 20 Cm, Railing With Full Closure Or Stringers , With A Maximum Spacing Of 15Cm, Portable Chemical Bathroom, With Assembly, Polyethylene Or Similar Material, With Ceiling, Dimensions 1, 50M X 1, 50M X 2, 30M High, Consisting Of Cashier 220 Liters, Toilet Paper Door, Identification Closure, 4 X 4 Dressing Room. Climatized, Consisting Of Aluminum Structure, With 02, 70M High, And Ts Formated Plates In Bright White Color, Paid Floor Anticipated. Structured With Metallic Profile With Black Carpet, Coverage Should Be In Vinyl Canvas On A Tubing Tubular Metal Structure Galvanized, And The Canvas Should Have A Minimum Weight Of 550G/Mý And Sunscreen, To Provide Greater Thermal Comfort In The Environment. Small Sound Car - With Hi Cashier, 01 Box In The Bottom And 02 Boxes. On The Sides, Being 02 By Side, With Speakers Of 15 + 101` + Driver Per Box, 04Canal Sound Table, 02 Dynamic Microphones, 01 Automotive Cd. Peace And The Physical Integrity Of The Bincantes., Energy Generator - 250Kva, Silenced With Acoustic Insulation Container, Up To 70 Decibel Shield At A Distance Of 4 Meters, 220 Voltal + Neutral Force Distribution Switch, All Of Which Are All Properly Grounded System, With Automatic Voltage And Frequency Regulator (60Hz), Short Circuit And Current Protection Panel, At Least 50 Meters Anti-Flamfruition That Meets The Power Supply Capacity Of The Generating Group, And The Cables They Should Be In Good Condition, Without Amendments And Within The Abnt Standards, Extinguished Fire, Protective Grids And Other Safety Equipment And Required By Legislation., Sound Rental - Sound Of Sound Truck With: Ability To Ensure Sound Of Approximately 300My, With 06 Sub-Speaker Of 1 Spi Shorves, 06 Average With 15 Spi Speaker, 06 Bricks, 06 Ti, 01 24-Channel Digital Table, 01 Cash Digital Processor, 01 31 Band Stereo Equalizer, 02 Microphones With Wire, 01 Full Lighting And A Dj., Covered Stage 1 - Measuring 12Mx8m, With Dressing Room, Right Foot 4, 40M, 2 Columns Of 1, 20X1, 20, Iron Structure, Canvas Ceiling Anti-Flames, Access Ladder, Front Skirt, Naval Plywood, 15Mm Thick, Structured And Closed In Pipes And Metallic Profile, Without The Use Of Nails, Closing On The Side, Including At Least Canvas Mix Mix 4Mx4m., Covered Stage 2 - Measuring 8Mx6m, Iron Structure, Including, Metallic Siding - Will Be On High Strength Galvanized Steel Plate, With A Minimum Height Of 2, 45M, Fixed To The Ground -Handed Ground And Picket Steel., Type 2 Lighting Service (Medium Size) With: 48 1000 Wats Vancishes, With Par 64 Lamp (Focus And Focus 5) And Colored Gelatins According To The Show (If Necessary The Same Mounted On 4 Or 6 Reflector Rods) : 01 6 Lamps Minibruute: 01 48 Kw Light Rack At The Minimum Digitaldmx (Or 2 24Kw): 01 Dmx 512 Digital Light Table At Least; 01 Ac From The Rack With At Least 50 Mis, 04 Movinghead 575 Spot;: 01 Smoke Machine, And
|