Tender For Electrification Of 32 Person Hostel Barack (8 Female And 24 Male) At Thana Sherkot Dist.Bijnor. - Wiring for light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 2 Same as above Item No 1 but for Fan & Fresh Air Fan point 3 Same as above Item No 1 but for exhaust Fan point 4 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 5 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 6 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X 1.5sq. mm + 1 X 1.5 sq. mm earth wire 8 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X 2.5sq. mm + 1 X 2.5 sq. mm earth wire 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 10 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X6 sq. mm + 1X4 sq. mm earth wire 11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2X10 sq. mm + 1X6 sq. mm earth wire 12 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire 13 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4 X16sq. mm + 2 X 6 sq. mm earth wire 14 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 15 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 16 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 17 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. 18 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door 19 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door 20 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door 21 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . 4way (4 + 12), Double door 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 23 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole 24 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. .63 A 25 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 26 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 27 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 28 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 29 Cost of 3 to 6 watt LED wall bracket Model No. 58071 as per Price listMake:- Philips 30 Add for Invertor Wiring in wiring Point for light/ Fan/ Plug with 1.5 mm FRLS PVC insulated wire. 31 Supply and laying of 2000×1000×2.5mm thickness checkered Electrical rubber matting of tested quality. 32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 50 Sqmmx3.5 core 33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 120 Sqmmx3.5 core 34 Providing and fixing circular/ hexagonal g.i. Box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick g.i. Sheet with its top surface hacked for proper bonding, top lid shall be screwed into the G.I. Box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia m.s. Bar bent to shape as per standard drawing. (DSR Civil-2014 item no. 10.18) 35 SupplyandlayingofaluminiumconductorPVCinsulatedarmouredservedsheathedcables1100Volts gradeatadepthof750mmbelowgroundlevelovera cushionof75mm.thicksandallaroundandprotected with burnt bricks on sides and on top. On surface the cable run shall be fixedon M.S. clamps etc. of suitable size or asdirectedbytheEngineer-Incharge, completeinall respect.Thearmouringofthecableshallbeproperly connected with the earth conductor by clamps etc. 150 sq. mm 3-1/2 core 36 Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing meteringAll Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided a accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type. Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA "C" Curve. Cubicle type switch board shall be Cat-A and B only.Incoming 200 Amp MCCB -1 No& outgoing 100 A MCCB-2 nos. 37 Supply and fixing of 18-22W LED Batten fitting with Extruded Aiuninumn housing, special polycarbenate difluser for glare free light distnbution and suitable mounting for on both surface & suspended. Compelete in all respect. 1980-2420 syslem lumens, >110 Lm/W, PF>0.95, THD<10%, CRI >80, with 3 year warranty. 38 S/f of IP 20, Front Lit, Mid Power SMD type LED light, recessSurface mounting round 10 Watt to 15 Watt , Cut out Min 125 mm, Height Min 40 mm,, LED Down Lighter having Powder coated die cast aluminiun housing with heat sink, High purity transmisivity UV Stabilized Non yellowish diffuser Reflector for unifom light distribution, detachable driver set, stable for 24 Hr Continous Operation, Complete in All respect 1100-1650 system lumen, >110 Lm/W, PF>0.95, THD <10% at full loàd, CRI >80, with 3 years warranty. 39 S/F of Water tight oblong 10wLED Bulk Head luminaire havingDie cast Alluminium housingwithdriver set confirming to IP 65 and above protection ,suitable for 24 Hrs. Continuous operation,complete in all respect.1100 system lumens, 110 Lm/W. PF>0.95, CRI>70, with 3 year warranty.Cat AA 40 Supply and fixing of LED Street light Fitting withmandatory driver set having die cast aluminium body with toughend glass/ UV stabilized PC Cover and lenses suitablefor 75 Watt. to 90 Watt and Confirming to IP 66, and IK07 and above protection having Company LOGO Engraved complete in all respect including Labour.9000-10800 system lumens, High Power LED with lenses,120 Lm/W, PF>0.95, THD <10% at full load, CRI >70,,Potted driver Set in Metal housing (Not Circuitory) Phase to phase Protection at 440V & >300V auto cut and re-startfeature, with 5 years warrantee. 41 S/F of LED Bulb 10 Watt 42 Supply of Fresh Air Fan300 mm Sweep metalic Complete in all respect. 43 Supply of 450mm Heavy duty Exhaust fan 44 S/F of 3w to 6w LED Decorative Mirror Light (Spot Light) fittingconfirming to IP 65 and above protection,complete in all respect.330-660 system lumens, 110lm/W. PF>0.95, THD<20% at full load with 5 year warranty. 45 S&Fof63Amp.fourpolechangeoverswitchon40mmx 40mmx6mmangleironframe,includingthecostoflabour, T&P,paintingandothermaterialrequiredforproper completionoftheworkasperdirectionandsatisfactionof Engineer in charge. 46 S&F of 80to 100 Amp4 pole MCCB (16 KA)Thermal Magnetic release 47 Supplyandfixingof16SWGM.S.drumwithluvers dulypainted includingmaking hole inthe wall for exhaust fan and finishing properly complete in all respect. 48 Supplyandfixingoffireextinguisher,ABCType4.00 kg.capacity(ISIMarkedIS: 15683& TACapproved) complete with initial charge and wall bracket, along with supply of all materials andlabour for proper completion of work. 49 Supply andfixingofC02typefireextinguisher4.5kg. capacity (ISIMarkedIS:2878&TACapproved) complete with initial charge and wall bracket, along with supply of all materials andlabour for proper completionof work.
|