tender for WORK For Repairing of Existing Building, Reservoir and Construction of Pump House and Boundary wall etc.work under Division Abu Road Nit No 35/2024-25 Sl. No. Item Description 1 1.6Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed : All kinds of soil 2 3.1Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.3.1.1M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 3 3.2Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.3.2.1 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 4 4.1Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 5 4.3Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 6 5.1Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks 5.1.1Cement mortar 1 : 4 (1 cement : 4 coarse sand) 7 5.1.2Cement mortar 1 : 6 (1 cement : 6 coarse sand) 8 6.1Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in:6.1.4Cement Mortar 1:4 ( 1-Cement : 4-Sand). 9 6.1.6Cement Mortar 1:6 ( 1-Cement : 6-Sand). 10 6.2Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in :6.2.4Cement Mortar 1:4 ( 1-Cement : 4-Sand). 11 6.2.6Cement Mortar 1:6 ( 1-Cement : 6-Sand). 12 7.5Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.7.5.1Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour)(i)Up to 1500 Cm2 Tiles 13 7.6Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.7.6.2Granite/Kota Stone Work(i)Full Edge moulding 14 (ii)Half Edge moulding 15 7.12Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 16 9.8Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 17 9.8.1Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 18 9.9Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design). 19 9.26Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 20 10.17Grading roof for water proofing treatment withwater proffing compound10.17.1Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 21 10.2Providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 22 11.3Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete11.3.140mmthickwith20mmthicknominalsizeaggregate. 23 11.3.275mmthickwith20mmthicknominalsizeaggregate. 24 11.2Rough Chisel dressed Kota stone 35 mm thick flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and pointingwith cement sand mortar 1:3 with pigment to match the shade of stone with joint thickness up to 15 mm complete in all respects : 25 12.1Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12.1.125 mm thick 26 12.1.220mm thick 27 12.3Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :12.3.125 mm thick 28 12.3.220mm thick. 29 12.31Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :12.31.1 Flush / Ruled/ Struck or weathered pointing. 30 12.31.2Raised and cut pointing. 31 12.31.3Deep groove pointing 32 12.37Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:12.37.1Newwork(twoormorecoats)overandincludingscrappingandprimingcoatwithcement primer. 33 12.37.2Old work (one or more coats) including scrapping surface andnecessaryrepairs.(a)Colour Change 34 (b)Same colour 35 12.37.3Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 36 12.41Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:12.41.1 New work (Two or more coats applied @ 3.84 kg/10 sqm). 37 12.41.2Old work (One or more coats). 38 12.45.3With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works 39 12.46Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 12.46.1Two or more coats on new work 40 13.1Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 41 13.11Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab including cutting chase and making good and painting exposed portion of the clamps complete. 42 13.12Repair to stone masonary in cement sand mortar 1:6 with old and new stone. 43 13.13Repair to brick masonary in cement sand mortar 1:6 withnew brick. 44 13.16Washing floor with soda, soap or other cleaning material. 45 13.23Repair of existing steel glazed doors, windows and ventilator, MS sheet door, garge doors, compound wall gates etc. by welding drilling complete include. Cost of welding rods and hire charge of welding meachine and TP etc complete 46 13.24Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. 47 13.26Repair of rolling shutter with replacement of shutter spring incl. removal of old spring in the existing rolling shutter incld. Cost of new spring 48 13.27Repair of rolling shutter with using any material such as bend repair , tightening of spring,bolt and screw etc complete 49 13.28Refebrication work with existingsteel work including cutting, welding & refebrication as per requirement with fixing at site complete as per direction of Engineer In charge 50 13.29Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-(i)Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.(ii)Applying Epoxy primer on the exposed steel bars.(iii)Applying Epoxy hardener and resin mix (as per manufectured"s specification) on concrete and steel bars with brush.(iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v)Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi)Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 51 13.34Making of holein R.C.C. slab/wall/beams and masonary wall (width up to 450 mm) by core cutting machine complete as per direction of EI13.34.1Fromdiameter 100mm to 150mm 52 13.34.2Diameter above 150mm 53 15.4Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compoundconsisting of applying : (i)after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm.(ii)laying secondlayer of Fiber glass clothwhen the first layer is still green. Overlaps of joints of fiber cloth should not be less than 10 cm .(iii)Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289kg/sqm mixed with water proffing cement compound@ 0.670kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around(iv)fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured 54 15.28Nano technology water proofing, thermal insulation protection coating : 15.28.1Nano technology water proofing, thermal insulation protection coating 12 layer process for increasing life of building and damage control for roof.-- before coating scaling, cleaning, and preparing surface for treatment. Opening all joint and cracks and filling them with nano technology crack filling hydrophobic chemical with 2/3 coats. then after drying doing a PCC coat on cracks. One coat of nano technology hydrophobic/oiliophobic primer. Nano technology water proofing treatment in3 coats non silicon based applied with fiber mesh sheets in medium. Nano technology thermal insulation coating highly elasticity in nature with 3 coats with 1000 micron width.2top coats of anti stain, anti slippery, natural transparent high shine chemical for better life of the treatment. 55 16.5Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)16.5.1With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. 56 16.5.2With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 57 16.5.3With float glass panes of 8 mm thickness 58 16.23Supply of “ Computer Table” of Modular nature having all the necessary arrangement for keyboard, CPU, UPS, Printer and wire manager Table Top :The table top of size 900 x 600mm(WxD) would be made out of post formed on 25 mm thick particle boardwith 0.7mm thick Carvica sheet in half round post formed finish on the front and rear side, matching color compensating laminate fixed on the bottom side. Other two sides are edge banded and duly sealed with 1.5 mm thick PVC edge banding of matching color with high pressure through feed machine. Keyboard Below the table top the keyboard pull out tray having sliding arrangement fixed on side supporting legs with 450mm G.I. telescopic channel. Keyboard of size 750 x 450 made out of 18 mm thick Particle board laminate with 0.7mm thick laminate sheet having all four sidesFlat edge banded and duly sealed with 1.5 mm thick PVC edge banding of matching color with high pressure through feed machine.Side Support:Two supporting side leg of size 600 x 750mm(WxH) made out of post formed on 18 mm thick particle board with 0.7mm thick Carvica sheet in half round post formed finish on two sides and other two sides are edge banded and sealed with 1.5mm thick PVC edge banding of matching color with high pressure through feed machine.Modesty Panel : Made out of18 mm thick Particle board laminate with 0.7mm thick laminate sheet of size 900 x 750mm(WxH) having all four sidesFlat edge banded and duly sealed with 1.5 mm thick PVC edge banding of matching color with high pressure through feed machine. 59 1.2P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: 1.2.1Size 530x410mm. 60 1.2.2Size 580x440mm. 61 1.4P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor 62 1.14P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.1.14.1Flat Back (small) size 456x355x265mm. 63 1.2P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall:1.20.1WVC with C.P. brass bend. 64 1.20.2PVC with PVCbend as per IS : 7231 . 65 1.36P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :1.36.1Size 450 mm x 300 mm 66 1.36.2Size 510 mm x 400 mm 67 1.38P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor :1.38.2Fire clay glazed kitchen sink (I.S 771-1985Marked) size 600 x 450 x 200 mm. 68 1.44P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. 1.44.1Size 600 x 450mm x 4 mm thick 69 1.47P & F Towel Rail or Ring of approved quality/make: 1.47.1C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty). 70 2.7P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:2.7.1Brass 400 gm,15mm nominal bore. 71 2.26P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 2.26.3500 litres capacity. 72 2.26.4750litres capacity. 73 2.26.51000 litres capacity. 74 2.37Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)2.37.115 mm nominal size 75 2.37.220mm nominal size 76 2.37.325 mm nominal size 77 2.37.432mm nominal size 78 2.39Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).2.39.115 mm nominal size 79 2.39.220mm nominal size 80 2.39.325 mm nominal size 81 2.39.432mm nominal size 82 3.16P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.3.16.163 mm dia 83 3.16.275 mm dia 84 3.16.3110 mm dia 85 3.22Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:3.22.1Size 300 Cm. dia outside & 300 Cm. depth . 86 3.22.2-do- & 240 Cm. Depth. 87 14.55Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 88 14.3Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 89 14.5Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge 90 14.6Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work 91 14.9Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge:14.9.1In lime mortar. 92 14.9.2In cement mortar. 93 14.13Taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead:14.13.1Of area 3 square meter and below. 94 14.13.2Of area exceeding 3 square meter. 95 14.23Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:14.23.1For thickness of tiles 10mm to 25mm. 96 14.23.2For thickness of tiles 25mm to 40mm. 97 4.2Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix 98 4.6.2Providing M-30 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix. 99 4.1Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :4.10.1Walls (any thickness) including attached pilasters,buttressesplinthandstring course. 100 4.10.2Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 101 4.10.3Columns, pillars, posts and struts etc. 102 4.10.4Spiral staircases, chimneys shafts etc. 103 4.10.5Arches, domes, vaults etc. up to 6 Mtr span. 104 4.10.6Arches,domes,vaultsetcexceeding6 Mtrspan 105 4.12Add extra forcentering and shuttering workin superstructure above floor five level for each four flooror part thereof . 106 4.13Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ("Original producers" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)4.13.2Hot rolled deformed bars (IS : 1139). 107 1.1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR1.1.1Short point (up to 3 mtr.) 108 1.1.2Medium point (up to 6 mtr.) 109 1.1.3Long point(up to 10 mtr.) 110 1.3Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure "A" attached with this BSR1.3.1On board 111 1.3.2Short point (up to 3 mtr.) 112 1.3.3Medium point (up to 6 mtr.) 113 1.3.4Long point(up to 10 mtr..) 114 7.3Providing & Fixing of 6 amp. Combined flush typenon modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 115 7.13Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 116 7.12Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 117 7.29Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR7.29.15 step fan regulator 2 Module 360 dgree rotating 118 14.1Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 119 15.7Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .15.7.11200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 120 6.4P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure "A" attached with this BSR6.4.1.125 Amp, 2 Module 121 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR Modular MCB 6 A to 32 ASP 122 Modular MCB 6 A to 32 ADP 123 Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required.Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR . 32 A rating 124 63 A rating 125 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure "A" attached with this BSR4.0 Sq. mm 126 2 core 127 3 core 128 4 core 129 6.0 Sq. mm 130 2 core 131 3 core 132 4 core
|