Tender For Annual Rate Contract for the year 2024-25- 1 Supply, Installation, Testing & Commissioning of 11/0.433kV, 25 kVA 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. 2 Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 63KVADistribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, andwith LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical Take off 3 Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 100KVADistribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, andwith LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical Take off 4 Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 200KVADistribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, andwith LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical Take off 5 Supply, Installation, Testing & Commissioning of 11/0.433kV, 3-phase, 250KVADistribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, andwith LV Cable Box having detachable Aluminium Gland plate.Transformer should have arrangement for vertical Take off 6 SITC of 11 Mtr long ST Poles 410, SP-56 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. 7 SITC of 9 Mtr long ST Poles 410, SP-33 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. 8 SITC of 8 Mtr long ST Poles 410, SP-15 including Transportation, manual, mechanical carriage, delivery at Site with pit excavation, refilling the pit with soil, boulders. 9 SITC of Earthing Complete by GI Pipe/ GI Rod 40 mm 3 Mtr long through GI Strip 25x3 mm as per REC Standards. 10 Supply and painting of each Pole 1 coat red oxide paint and 2 coats of aluminum paint (@ 1 ltr/pole red oxide paint and 1 ltr/pole aluminum paint) inscribed with permanent marking on each pole "Name of scheme-2024-25/xx" (xx mean pole numbers say 01,02...) in white paint in background of green paint at conspicuous place. The paint shall have to be sprayed not brushed. 11 SITC of GI channel cross arms, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings, including back clamps for fixing cross arms etc. fabricated out of Galvanized Iron of different sizes (REC Standard) & to be fixed with GI Nuts & Bolts and washers. 12 SITC of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 13 Providing & fixing of Mucki clamps/LT Shackles with insulators 14 Providing & fixing of 11 kV Horn Gap Fuse Set 3 Phase 200A 15 Providing & fixing of 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type 16 Providing & fixing of 11KV Gapless Surge Arrestor, 9 kV ,10 kA, LA with polymer housing, Stn. Type 17 Providing & fixing of LT Fuse Set 18 Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 19 Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 20 Providing & fixing of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 21 Providing, laying, testing & commissioning of 3x35mm sq +1x105mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 22 Providing, laying, testing & commissioning of 3x50mm sq +1x70mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 23 Providing, laying, testing & commissioning of 3x70mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 24 Providing, laying, testing & commissioning of 3x120mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03 (three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural colored XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 25 Providing, fixing, testing & commissioning of11 kV Heat Shrinkable Outdoor Cable Termination Kit above 240-300 mm² ( 3 Core) 26 Providing, fixing, testing & commissioning of 11 kV Heat Shrinkable Outdoor Cable Termination Kit 150 -185 mm² ( 3 core) 27 Providing, fixing, testing & commissioning of cable kits (push on type) 28 Providing & fixing of Suspension/Tension clamps with eye hooks 29 Providing & fixing of Dead-end clamps 30 Providing & fixing of Cable Jointing Kit 31 Providing and fixing of Anticlimbing devices on poles of GI barbed wire type devices). At-least 3.5 kgs GI barbed wire (12 SWG) 32 Providing and fixing of Danger Plates on poles with clamps and writing in English and Regional Language 33 Providing & fixing of Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per REC standard. 34 Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete. 35 Providing, laying of Cement bottoming 1:2:4 mix as per REC standards 0.45 cum/pole including muffing 20 cm above ground level, plaster and curing of concrete. 36 Providing and fixing of 3 No. substation earthing by GI Pipe 40 mm or GI Rod 20mm, 2.5 Mtr long through GI Strip of 50X6 for neutral earthing and 25X3 mm for 2 transformer body earth, two no. pole earth, 1 no. LA Earth and 1 no. GO handle earth as per REC approved construction standards with F5, F10 & J2 drawings issued by REC as reference. Each electrode to be connected through double GI strips to be fixed on baby insulators. The termination should be bolted and not welded. 37 Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices 38 Providing, Laying, stringing, tensioning and binding of conductor ACSR 0.0.3 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices 39 Loading, Transportation, Erection, testing & commissioning, Carriage and Delivery at Site of 11 Mtr long ST Poles SP-56 including excavation of pole pits, refilling the pit with soil, boulders. 40 Loading, Transportation, Erection, testing & commissioning, Carriage and Delivery at Site of 9 Mtr long ST Poles SP-33 including excavation of pole pits, refilling the pit with soil, boulders. 41 Loading, Transportation, Erection, testing & commissioning, Carriage and Delivery at Site of 8 Mtr long ST Poles SP-15 including excavation of pole pits, refilling the pit with soil, boulders. 42 Loading, Transportation, Erection, testing & commissioning, Carriage and Delivery at Site of 8 Mtr long PCC Poles with excavation of pole pits with inscription of permanent marking on each pole "Name of scheme-2024-25/xx" (xxx mean pole numbers say 01,02...) in white paint in background of green paint at conspicuous place 43 Loading, Transportation, Installation, Testing, Commissioning of 25 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers 44 Loading, Transportation, Installation, Testing, Commissioning of 63/100 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers 45 Loading, Transportation, Installation, Testing, Commissioning of 200/250/400 kVA Distribution Transformer including mechanical/manual carriage upto site of installation and fixing of all fittings and jumpers 46 Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.1 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site. 47 Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.05 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site. 48 Loading, Transportation, Laying, stringing, tensioning and binding of conductor ACSR 0.03 including pre-tensioning for removal of kinks, fixing of hardware fittings and jointing as per standard practices and mechanical/manual carriage upto site. 49 Erection, testing & commissioning of channel cross arm, V-Cross arms, Sub-station channels & Angle Iron Braces, transformer beltings etc. to be fabricated out of Galvanized Iron of different sizes & to be fixed with GI Nuts & Bolts and washers. 50 Installation of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 51 Installation of Mucki clamps/LT Shackles with insulators 52 Installation of 11 kV Horn Gap Fuse Set 3 Phase 200A 53 Installation of 11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type 54 Installation of 11KV Gapless Surge Arrestor,9 kV ,10 kA, LA with polymer housing, Stn. Type 55 Installation of LT Fuse Set 56 Installation, laying & commissioning of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 300 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 57 Installation, laying & commissioning of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 185 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 58 Installation, laying & commissioning of Single Core Aluminum (Al.) LT Power Cable (1.1 KV grade) 120 mm sq cross section un-armored XLPE cable with Thermoplastic tape inner sheath from the LT bushes upto the overhead LT bare conductor. 59 Installation, laying & commissioning of 3x35mm sq +1x105mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 60 Installation, laying & commissioning of 3x50mm sq +1x70mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 61 Installation, laying & commissioning of 3x70mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural coloured XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 62 Installation, laying & commissioning of 3x120mm sq +1x95mm sq 11kV grade 11 KV (E) Grade Aerial Bunched Cable with 03(three) power cores stranded, compacted circular Aluminum conductor screened with Black extruded semi conducting compound, natural colored XPLE insulated core screened with Black extruded semi conducting compound and one layer of copper tape and covered with Black extruded PVC (core identification by ridges one, two and three over PVC covering) and one bare Messenger wire: combination of galvanized steel wire and Al. Alloy wires. 63 Dismantling of 11 Mtr long ST Poles including carriage to divisional stores. 64 Dismantling of 9 Mtr long ST Poles including carriage to divisional stores. 65 Dismantling of 8 Mtr long ST Poles including carriage to divisional stores. 66 Dismantling of wooden Poles including carriage to divisional stores. 67 Repositioning of 11 Mtr ST tilted poles 68 Repositioning of 9 Mtr ST tilted poles 69 Repositioning of 8 Mtr ST tilted poles 70 Repositioning of PCC tilted poles 71 Repositioning of tilted wooden poles 72 Dismantling of conductor ACSR 0.1 including hardware fittings and returning the dismantled material to stores. 73 Dismantling of conductor ACSR 0.05 including hardware fittings and returning the dismantled material to stores. 74 Dismantling of conductor ACSR 0.03 including hardware fittings and returning the dismantled material to stores. 75 Re-stringing, tensioning and binding of conductor ACSR 0.1 including fixing of hardware fittings and jointing as per standard practices 76 Re-stringing, tensioning and binding of conductor ACSR 0.05 including fixing of hardware fittings and jointing as per standard practices 77 Re-stringing, tensioning and binding of conductor ACSR 0.03 including fixing of hardware fittings and jointing as per standard practices 78 Engagement of Labour for Branch cutting/ Trimming and any other electric work related to the maintenance of power supply 79 Skilled 80 Semi-Skilled 81 Labour 82 Assistant Fitter 83 Installation, Testing & commissioning of Single-Phase Meter/ Three Phase Meter. (10mm2 Cable 2-Core, 1.1KV Grade, Armored XLPE Insulated Stranded Conductor FRLS type.) Complete Job. 84 Installation, Testing & commissioning of Single-Phase Meter/ Three Phase Meter. (16mm2 Cable, 4-Core, 1.1KV Grade, Armored XLPE Insulated Stranded Conductor FRLS type.) Complete Job. 85 Supply, Installation, Testing & commissioning of Prodigy Meter (35mm2 Cable 4-Core, 1.1KV Grade, Armored XLPE Insulated Stranded Conductor FRLS type.) Complete Job. 86 Supply, Laying, Fixing of 50 mm² AB (HT) Cable (3x50 + 1x70 insulated) mm² XLPE (11 kV, 3C + Earth) 87 Suppy, Laying, Fixing of 35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth) 88 SITC of 50 mm² AB (LT) Cable (3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al) 89 SITC of 35 mm² AB (LT) Cable (3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al) 90 SITC of 50 mm² Single-Core Cable, 1.1kV Grade, XLPE un armoured FRLS type 91 SITC of 35 mm² Single-Core Cable,1.1kV Grade, XLPE un armoured FRLS type 92 Laying, Fixing of 50 mm² AB (HT) Cable (3x50 + 1x70 insulated) mm² XLPE (11 kV, 3C + Earth) 93 Laying, Fixing of 35 mm² AB (HT) Cable (3x35+1x70 insulated) mm² XLPE (11 kV, 3C + Earth) 94 Laying, Fixing of 50 mm² AB (LT) Cable (3 x 50 + 1 x 16 + 1 x 35 insulated) mm² XLPE (1.1kV, 3+1 C, Al) 95 Laying, Fixing of 35 mm² AB (LT) Cable (3 x 35 + 1 x 16 + 1 x 25 insulated) mm² XLPE (1.1kV, 3+1 C, Al) 96 Laying, Fixing of 50 mm² Single-Core Cable, 1.1kV Grade, XLPE un armoured FRLS type 97 Laying, Fixing of 35 mm² Single-Core Cable,1.1kV Grade, XLPE un armoured FRLS type
|