Pro.157/25 Drinking Water Facilities For Block Panchayath Providing Motor Pumpset , Water Pump Installation , 90.14.1.2:Fabrication, Supply, Conveyance, Installation Testing And Commissioning Of Floor Or Wall Mounting, Dust And Vermin Proof, Cubicle Type Mv Panel Board Comprising Of The Following Components/ Devices & Complying To Is 8623. Fabrication Of Fully Partitioned, Dust And Vermin Proof Enclosure For Panel Assembly As Per Form 4 Of Is 8623 (With Latest Amendments) Using Crca Sheet As Per Approved Design And Requirement, With Front And Rear Access Facility, Bus Bar Chambers, Hinged Doors For All Switch Gear Compartments, Earthing The Doors Using 4 Sq Mm Braided Copper Conductor, Providing Necessary Cut-Outs For Mounting Meters, Relays, Indication Lamps, Bus Bar Interconnection Etc, Detachable Covers For Bus Bar Chamber And Cable Alley, Powder Coating The Assembly After Subjecting To 7 Tank Process Etc As Required. Crca Sheet Alone Be Used For The Fabrication. Angles/ Flats/ Slotted Angles Etc Shall Not Be Used For The Fabrication Of Panel Assembly. The Measurments Will Be Taken The Area Of The Complete Sheets Used For Panel Board Including Partitions, Folding, Shrouding Etc.Supply And Fabrication Of Mv Panel Board Using 1.6Mm Crca Sheet, Powder Coated (Excluding Base Frame) , 90.14.2.1:Supply And Providing 2Mm Smc Sheet As Shrouding For Bus Interconnection / Terminations Etc. Including Required Nut & Bolt Etc. , 90.14.3.2:Supply And Providing Heavy Duty A Section Neoprene Gasket In The Panel Boardu Section Rubber Beeding Suitable For 1.60/ 2.00 Mm Sheet , 2.1.1:Providing And Fixing Following Capacity Tp&N Disconnector Fuse Switch Unit Inside The Existing Panel Board With Isi Marked Hrc Fuses Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.32 Amp Tp & N , Od326172/2024-2025:Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly, Door Interlock And Pad Locking Arrangement Of 32 A, Ac 23 A, 4 Pole On-Load Cosfixed On Suitable Size Cubicle Box Made Out 1.60 Mm Crca Sheet Of Suitable Size To Match The Switch Gear, Provision For Providing2 Sets Indication Lamps And Enabling The Cables To Be Connected Without Strain, Painted With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer & With Drilled Holes And Mounting To The Switch Gear Etc As Required. , 90.14.24.3:Supply & Fixingthe Following Power Capacitors 3 Phase Delta Connected In Positon And Giving Connection.3 Kvar, 3 Phase, 440 V, Delta Connected Standard Duty Metalised Poly Propylene Capacitor, Cylinderical Type Suitable For Direct Connection To Motors. , 90.14.28.14:S & F Motor Starters Of The Following Ratingssubmersible Pump Controllers With Ammeter,Tpmcb For Three Phase 5 To 7.5Hp Submersible Motor Pumps (Dol) , Od326150/2024-2025: Supply And Providing Single Phasing Preventer , Od326145/2024-2025:Led Indicators For All Voltage Ranges - Red, Green &Blue Colour , Od326152/2024-2025:5A 3 Pole Voltmeter Selector Switch , Od326149/2024-2025:0/600Vanalogue Type Ac Volt Meter With 90* Defluction Scale (72X72mm) , Od326151/2024-2025:2A Bolted Offset Tag Typefuse Link(Group A) , 1.21.2:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm , 1.17.22:Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel/ Pvc Conduit As Required.4 X 4 Sq. Mm , 90.6.6.3:Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.4 Sq Mm , 2.15.2:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , Od326187/2024-2025:Supply ,Installation, Testing And Commissioning Of 7.5Hpthree Phase Submersible Type Motor Pump Set (Silver/Decon/ Or Eqvt.) 13-80 Mt. Head 4 Stage, Delivery Size 50 Mm Using Leak Proof Materials And Suspended On10/12Mm Stainless Steel Rope/Nylon Rope Including Fixing And Connected Delivery Pipeone By One To The Motor Up To The Bottom Of The Well Using Leak Proof Materials As Required With Necessary Supports On Both Sides Of The Motor And Giving Connection, Trail Run Etc.As Per The Direction At Site As Required. , Od326138/2024-2025: Supply And Providing50/65 Mm Gm Non Return Valve Heavy Duty As Required , Od326154/2024-2025: Supply And Providing50/65 Mm Ms Flange Set As Required. , Od326177/2024-2025:Supply. Conveyance, Laying And Joining Of50/63 Mm Size Hdfe Flexiblepipe 6 To10 Kg Cm Approved Make With Required Accessories As Delivery Pipe Using Required Proofing Materials Etc.As Required , Od326140/2024-2025:Supply Conveyance And Providing 50/65 Mm Gi Hose Coller , Od326142/2024-2025:Supply Conveyance And Providing 12 Mm Nylon Rope. , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Od326144/2024-2025:Supply And Providing Earth Lead From The Test Joint To The Earth Electrode Using 25 X 3 Mm Gi Strips Including Cutting, Drilling Necessary Holes (In Case Of Strip) And Fixing Firmly With Plate Test Joint Etc As Required , Od326146/2024-2025:&Nbsp;Supply And Providing 32 A Hrc Fuse With 25 A Fuse Link And Giving Connection On Existing Panel Board. , Od326148/2024-2025:Supply And Providing 32-A Neutral Link Mounted On Dmc/ Smc Base And Giving Connection On Existing Panel Board. , Od326147/2024-2025:Supply & Installation Of Dust And Vermin Proof, Wall Mounting, Single/Three Phase Syntax Meter Box (Gs Mb-4537) Cm For Fixing Kseb Meter,Fuse Units, Ct,Mcb,Timeretc, Hinged Door Construction , Providing Vision Panel For The Meter Compartment, Knock Out For Cable Entry And Exit Etc.As Required Including Fixing To Wall And Making Good The Wall As Required.. , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , Od326137/2024-2025:Supply And Providing The 25 X 3Mm Brass Bolt & Nut With Washers On The Existing Ms Box / Earth Bus Etc. As Required Including Drilling Necessary Holes As Required , 90.14.5:Supply And Fabrication Conveyance And Installation Of Angle Iron Frame Work For Wall Mounting Panel Board , 90.3.18.4:Supply, Fabrication, Conveyance And Fixing The Following Sizes Of B Class Gi Pipe Bent To Shape / Cut And Welded To Shape And Fixing The Same To Wall / Parapet Using Clamps As Noted Along With Each Size, Painting With 2 Coats Of Synthetic Enamel Paint Over A Coat Of Zinc Chromate Primer, Making Good The Damages, Colour Washing Etc As Required.50 Mm Dia With Clamps Made From 25 X 3 Mm Ms Flat
|