Tender For Provision Of Hrdc Bldg At Inf School Mhow.; 2 SCHEDULE "A" PART-I (Building Work)Lump sum price worked out by the contractor for "Building Work" as listed in Schedule "A" Part-I against the lump sum price inserted by the MES. 3 Sch "A" Part-II (B/R works including internal services)Lump sum price worked out by the contractor forB/R works including internal services as listed in Schedule "A" Part-II against the lump sum price inserted by the MES. 4 Sch "A" Part-III(External Water Supply)Lump sum price worked out by the contractor for "External Water Supply" as listed in Schedule "A" Part-III against the lump sum price inserted by the MES. 5 Sch "A" Part-IV(Internal Electrification)Lump sum price worked out by the contractor for "External Water supply" as listed in Schedule "A" Part-IV against the lump sum price inserted by the MES. 6 Sch "A" Part-V(External Electrical Supply)Lump sum price worked out by the contractor for"External Electrific Supply" as listed in Schedule "A" Part-V against the lump sum price inserted by the MES. 7 Sch "A" Part-VI(Fire detector system)Lump sum price worked out by the contractor for "Fire detector system/ Alarm System" as listed in Schedule "A" Part-VI against the lump sum price inserted by the MES. 8 Sch "A" Part-VII(Water Cooler)Lump sum price worked out by the contractor for "Water Cooler " as listed in Schedule "A" Part-VII against the lump sum price inserted by the MES. 9 Sch "A" Part-VIII (Lan Conduit)Lump sum price worked out by the contractor for "Lan Conduit " as listed in Schedule "A" Part-VIII against the lump sum price inserted by the MES. 10 Sch "A" Part-IX(Refrigeration and air conditioning)Lump sum price worked out by the contractor for "Refrigeration and air conditioning" as listed in Schedule "A" Part-X against the lump sum priceinserted by the MES. 11 Sch "A" Part-X(Rain Water Harvesting)Lump sum price worked out by the contractor for "Rain Water Harvesting" as listed in Schedule "A" Part-X against the lump sum priceinserted by the MES. 12 Sch "A" Part-XI(Road, Path & Hard standing)Lump sum price worked out by the contractor for "Road, Path & Hard standing", excavation & earth works" as listed in Schedule "A" Part-XI against the lump sum priceinserted by the MES. 13 Sch "A" Part-XII(SewageDisposal)Lump sum price worked out by the contractor for "SewageDisposal", excavation & earth works" as listed in Schedule "A" Part-XI against the lump sum priceinserted by the MES. 14 Sch "A" Part-XIII(Area Drainage)Lump sum price worked out by the contractor for "Area Drainage", excavation & earth works" as listed in Schedule "A" Part-XI against the lump sum priceinserted by the MES. 15 Sch "A" Part-XIV(SITE CLEARANCE)Lump sum price worked out by the contractor for "Site clearance, excavation & earth works" as listed in Schedule "A" Part-XI against the lump sum priceinserted by the MES. 16 Note for Srl No 2 to 15The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 15by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule 17 Schedule "A" Part-XII (Miscellaneous items of works) 18 Sewage Disposal 19 Item No 01 : S&F factory made SFRC MH cover with frame confirming to IS 12592:2002 HD 20 grade, of size 600mm circular or square, sorrounded with steel strip 70 x 1.5 mm reinforced shall be as per relevant IS andlaid over man hole brick work or concrete in CM 1:4, incl reinforcement, complete all as specified and as directed. Notes: -(i) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover. 20 Item No 02 : Supply, laying and testing of 150 mm inner diameter of double wall corrugated (DWC) high density polethelene pipes(HDPE) and stiffness class-8 (SN-8) with ISI marked (with CML No) with and including all fittings & jointing materials for sewage line and laid in trenches as specified in IS-16098(Part-2):2013 and as per manufacturer"s instruction complete all as specified and as directed. Note:- Bedding of pipe shall not be provided in normal condition and construction methods shall be strictly compiled as per clause no A-4 Annex "A" of IS 16098(Part-2):2013 21 Fire detector system/ Alarm System 22 Item No 03 : S & F for Detector Complying with & type cetified to EN-45 Addressable type Multisensor detector with heat and smoke combination /Optica with base with self built intelligence as per IS: 11360. 23 Item No 04: S & F testing & Commission of MICRO processer with Digital Display fire control Panel with Single Panel of capacity for 99 Detector & 99 Module upto 200 detector & modules fitting with autoatic battery charger including Maint free battery , including lamp with all connected accessories 1 Zone. 24 Item No 05 : S & F including Testing, Commmessioning of Manual call point resettable type complete all as specified.. 25 Item No 06 : S & F for fire Alarm Sounders/ sirens Electronic type horizontal two stage continous normal operation for atlast 50 minutes with sound level 65 DB to 120 DB measured at 105m with sound out put variation of + 5 DB upto 500 mtr range complete all as specified. 26 Item No 07 : Remote Indicator/ Response indicator (LED TYPE) complete all as specified. 27 Item No 08 : Supply and installtion of OH water storage tank GRP/FRP of capcity 5,000 ltrs complete all as specified. 28 Item No 09 : S & F for Terrace Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz, 30m head, 450 LPM discharge complete all as specified and as directed 29 Item No 10 : Supply and fix Air cushioning tank (Air vessel) 250mm dia x 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete. 30 Item No 11 :S & F for MS flanged pipe 25 mm NB heavy dutyduly painted with 2 coats of synthetic enamel paint over zinc chromate peimer complete all as specified and directed. 31 Item No 12 : S & F for Sprinkler glass bulb type (Standard response) as per IS:15106/TAC guidelines 68 degree temperature rating pendent type complete all as specified and as directed 32 Item No 13 : Supply & Fixing Exist sign board or information board duly fabricated with flexo sheet or high grade quality and writing/ printing of information/picture/drawing/layout pln over flexo sheet duly structure framed with square iron bar of suitable size and fixed with suitable screws complete all as specified and as directed. 33 Item No 14 : S & F for Fire extinguiser ISI marked CO2 type 4.5 KG for "B" & "C" class of approved by explosive depatment, Govt of India Nagpur and conforming toIS : 15683 :2006 (old IS-2878) complete all as specified and as directed. 34 External Water Supply 35 Item No 15 : Supply, laying and testing of centrifugally cast (Spun) ductile iron pressure pipe Class K-9 with spigot and socket ends in and including rubber gaskets of suitable size for connecting the tyton joints, pipes duly applied with zinc coating with finishing layer of bitumen on external surfaces and cement mortar liningwith bituminous seal coat on internal surfaces complete conforming to IS -8329 (2000), complete of following sizes all as specified and directed by the Engineer-in Charge at site. 36 (a) 100 mm (4’’) dia 37 (b) 80 mm (3’’) dia 38 Item No 16 : Supply and fix cast iron sluice vave, PN 1.0 (flanged) hand wheel operated, Non rising stainless steel stem, Bronze body seat ring flanged drilled to IS 1538, of following size with ISI mark 39 (a) 100 mm (4’’) dia 40 (b) 80 mm (3’’) dia 41 Item No 17 : M&L for Construction of brink masonry valves pits, of following internal dimension complete with 3.5 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete 42 (a) 900 mm x 900 mm x 900 mm 43 (b) 600 mm x 600 mm x 600 mm 44 Item No 18 : Cutting cast iron main pipes 150 mm dia and inserting 150 mm dia tee to required length before laying and insert new tees, in position for branches including excavation and earth work complete in including 150 x 150 x 150 mm equal CI Tee and run lead joints etc complete all as specified and as directed 45 Item No 19 : M&L for ductile iron fittings, as per IS : 9523 (2000) , Class K-9 suitable for spigot and socketed ends of size upto 150 mm bore dia complete all as specified and directed 46 External Electrical Supply 47 Item No 20 : Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1500 mm x 1200 mm x 500 mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incommingcableinclusive of necessary excavation and earthwork as required including the following fitment accessories and also including removing old exisisting one complete all as specified and as directed. 48 INCOMING 49 (a)Copper strip busbar of 500 amps rated capaacity wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos(b)4 Pole MCCB 250 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-01 Nos 50 (c)LED Neon indicator lamp (RYB) with holder and fuse holder 230/250 volts, AC -01 set (set of three)(d)Digital Ammeter, flush mounting type with CT’s of ratio 800/5 and selector switch – 01 set (e)Digital voltmeter of range (0-500) volts, flush mounting type with selector switch – 01 No 51 OUTGOING 52 (a) 4 Pole MCCB 160 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-01 Nos (light load)(b) 4 Pole MCCB 100 Amps with rotaryhandle, adjustable thermal magnetic release type, 4 pole, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity including all fixing accessories with both ends spreader links-02 Nos (Power load for Bldg Panel ) 53 (c)Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150 mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of JB for LT -01 No. 54 Refrigeration & Air Conditioning 55 Item No 21: Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of ± 2.5 % and capacity 5 kVA suitable for A/C complete all as specified 56 Water Cooler 57 Item No 22: Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with output voltage stablized at 230 volts with accuracy of ± 2.5 % and capacity 2 kVA suitable for above water cooler 58 Internal Electrification 59 Item No 23: S & F modular type TV Socket out let complete all as specified and as directed. 60 Item No 24: S & F modular type LAN Socket RJ 45 with complete box 61 Item No 25: S & F modular type Telephone socket RJ 11/12 with complete box 62 Item No 26: S & F for MCCB four pole rated capacity 160 Amps, 415 Volts breaking capacity 16 KA, complete all as specified and as directed. 63 Item No 27: S & F modular MCB protected socket comprising of 24A MCB C curve, and 16/20 A Socket for AC/Geyser, modular switch 16A complete with Sheet metal Enclosure for 230 volt 50 Hz AC including all acessories as one complete set all as specified and as directed. 64 Item No 28: S& F occupancy sensor suspended type to detect the presence of a person for include automatic adjustment of lights systems in response to the quantity of people present for switch off/on the light in a circuit as per user reqmt (for use at parking area, verandah or any other space where power saving
|