Tender For Supply Of Network Items - 01 UTP CABLE 1 Box color (305 meters) Type:-UTP, Category:-Cat6 , colour Blue 10BASE-T, 100BASE-TX Fast Ethernet, 1000BASE-T,10GBASE-T (IEEE802.3) This cable well exceeds the requirements of TIA/EIA-568-C.2 and ISO/IEC 11801 Construction: 4 twisted pairs separated by internal X shaped, 4 channel, polymer spine / full separator. Half shall not be accepted. The 4 pair Unshielded Twisted Pair cable shall be UL Listed. Conductor Solid bare Copper and Jacket FR PVC and UL approved CM rated cable CAT 6 Cable with zero bit error rate of 1000BASE-T protocol, certificate must be attached CAT 6 Cable must be with Performance Testing of a cabling according to ANSI/TIA 568-2-D 4 connector channel, for all component certificate must be atatched 02 LC-LC SM PATCH CORD PATCH CORD LC-LC SM DUPLEX Type=Duplex 3.0mm Length=1 m Connector Type=LC-LC Insertion Loss =<0.2 dB ,MAX <0.3dB 03 SC-SC SM PATCH CORD PATCH CORD SC-LC SM DUPLEX Type=Duplex 3.0mm Type=Duplex 3.0mm Length=1 m Connector Type=SC-SC Insertion Loss =<0.2 dB ,MAX <0.3dB UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in 04 ST-LC SM PATCH CORD PATCH CORD ST-LC SM DUPLEX Type=Duplex 3.0mm Type=Duplex 3.0mm Length=1 m Connector Type=ST-LC Insertion Loss =<0.2 dB ,MAX <0.3dB 05 ST-SC SM PATCH CORD PATCH CORD ST-SC SM DUPLEX Type=Duplex 3.0mm Type=Duplex 3.0mm Length=1 m Connector Type=ST-LC Insertion Loss =<0.2 dB ,MAX <0.3dB 06 SC SM PIGTAIL pigtail SM Simplex Type= Simplex 3.0mm Length=1 m Connector Type=SC Insertion Loss =<0.2 dB ,MAX <0.3dB 07 SC SM COUPLER ( Simplex) Single mode SM (Single ) 08 SC SM COUPLER ( Duplex) Single mode SM (Dual/ duplex ) 09 RJ-45 CONNECTOR CAT 6 UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in 10 Single I/O box Fully loaded with single Face plate, wall plate and CAT6 jack ( Yellow for Data) 11 Dual I/O box Fully loaded with dual Face plate, wall plate and dual CAT6 jack ( Yellow for Data) 12 Fiber Cable Single Mode 6 Core Fiber Cable Outdoor Armored SM HDPE Sheath Number of Cores=6 Type=Single Mode Outdoor Armored 13 Fiber Cable Single Mode 12 Core Fiber Cable Outdoor Armored SM HDPE Sheath Number of Core =12 Type=Single Mode Outdoor Armored 14 Fiber Cable Single Mode 24 Core Fiber Cable Outdoor Armored SM HDPE Sheath Number of Core =24 Type=Single Mode Outdoor Armored 15 Fiber Cable Jointer Box (Lightweight, Airtight & waterproof) Dimensions : Min. Length 403mm, Max. Diameter 220mm Cable ports : 1 oval port and 4 small round ports Cable Diameter: 8mm – 25mm Max. Capacity (Bunchy Fiber): 96 fibers Core capacity per tray : 24 Sealing structure: Heat-shrinkable sealing Protection Grade IP65 16 Indoor Outdoor FTTH Fiber Optic Termination Box ABS Body Material Fiber Distribution Panel PC+ABS material used ensures the body strong and light Wet-proof, water-proof, dust-proof, anti-aging Easy installations: Ready for wall mount – installation kits provided Space saving: Double-layer design for easier installation and maintenances Protection level up to IP53-IP55 Cabinet can be installed by the way of wall-mounted or poled-mounted, suitable for both indoor and outdoor uses Distribution panel can be flipped up, feeder cable can be placed in a cup-joint way, easy for maintenance and installation Cable,pigtails,patch cords are running through own path without disturbing each other, cassette type SC adapt or installation, easy maintenance 17 2U RACK Rack With Cable manager, Fan and PDU.The Rack Should be wall mount 2U in hight and Conforms to DIN 41494 or equivalent ISO Standards UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in 18 4U RACK Rack With Cable manager, Fan and PDU.The Rack Should be wall mount 6U in hight and Conforms to DIN 41494 or equivalent ISO Standards 19 6U RACK Rack With Cable manager, Fan and PDU.The Rack Should be wall mount 6U in hight and Conforms to DIN 41494 or equivalent ISO Standards 20 9U RACK Rack With Cable manager, Fan and PDU.The Rack Should be wall mount 9U in hight and Conforms to DIN 41494 or equivalent ISO Standards 21 27U RACK Rack With Cable manager, Fan and PDU.The Rack Should be floor mount 27 U in hight and Conforms to DIN 41494 or equivalent ISO Standards 22 6 PORT LIU Unloaded 1.2 mm steel sheet for strong housing Slim 1 Unit Mounting Height Front-mounted cable saddles for jumper management Can manage both splices and terminations Preassembled shelves in multiple configurations Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers 2 fiber spools built-in for 900 μm tight buffered fiber storing Capable of storing up to 3 meters of 900 μm tight buffered fiber per adapter 23 12 PORT LIU Unloaded 1.2 mm steel sheet for strong housing Slim 1 Unit Mounting Height Front-mounted cable saddles for jumper management Can manage both splices and terminations Preassembled shelves in multiple configurations Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers 2 fiber spools built-in for 900 μm tight buffered fiber storing Capable of storing up to 3 meters of 900 μm tight buffered fiber per adapter Ball bearing slid rails with Positive stop All racks and copper and Fiber component should be from single OEM for easy integration , whose MAF is attached with Bid UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in 24 24 PORT LIU Unloaded 1.2 mm steel sheet for strong housing Slim 1 Unit Mounting Height Front-mounted cable saddles for jumper management Can manage both splices and terminations Preassembled shelves in multiple configurations Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers 2 fiber spools built-in for 900 μm tight buffered fiber storing Capable of storing up to 3 meters of 900 μm tight buffered fiber per adapter Ball bearing slid rails with Positive stop 25 SC SM COUPLER ( Simplex) Single mode SM (Single ) 26 IO PUNCH DOWN TOOL punch down tool, which can also be named an RJ45 punch down tool, or Krone tool, is a hand tool widely used to terminate the Ethernet cables by inserting the cable wires into the insulation-displacement connectors (IDC) on the punch down blocks, patch panels, keystone modules, and surface mount of boxes. 27 OTDR Machine Optical Time Domain Reflectometer SM 1310/1550nm 26/24 dB OTDR Tester with SC FC ST LC Adapters, Multi-function Fiber Optic Tools OTDR, 4.3-inch Touch Screen Color LCD One Key Operation Able to generate different forms of test reports according to user need TOP : Otdr / Ls Port , Opm Port, Vfl Port, Flashlight, Tf Card, Type C Usb MAIN VIEW : Dust Cover, 4.3 inch color LCD, Function Key, Charging Indicator, Power On Status Indicator User friendly interface, totally simulate the computer keyboard input 28 Crimping Tool with tester Suitable for network cable with RJ45 Connector and ADSL Cable with RJ11 Connect. Suitable for Cat5 and Cat5e cable with 8P8C, 6P6C and 4P4C plugs For network installations up to 100 Mbps 10Base-T Ethernet and Token Ring. Battery included Double colour grip 150b wire cutter included UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in 29 24 Port Switch 10/100/1000 Managed PoE Switch Switch should have 24x 10/100/1000BASE-T PoE ports Ports with 4 x10G SFP+ ports for uplink purpose Switch should have Console Port (RJ-45) for out-of-band CLI management, provide a direct, physical connection to the switch for management tasks, which can be especially useful if remote management is not possible Switch should have 16K MAC Address and 2 MB Packet buffer memory Switch should have 128 Gbps Switching capacity and 95 Mpps packet forwording rate 30 Media Convertor Converts 1000 Base - T to 1000 Base – LX Fiber wavelength:-1300NM max distance:-10KM Ports:- One RJ - 45 and Duplex Fiber port (SC type connector) MODE:- SINGLE MODE Operating Temperature:- 0° C to 50° C torage Temperature:- -20° C to 70° C MTBF (hours):- 10,0000hours Operating Voltage:- AC 240V or DC +5V 31 Network Item: SFP + 10G MODULE (SM) : LC Port Types, 10GBASE-LR SFP+ Transceiver (w/o DDM) Full Duplex 802.3x Flow Control Optical Receiver Sensitivity= - 14dBm Min. (dBm) Type=Single mode Hot Pluggable 32 Network Item: Indoor wireless AP Gigabit LAN(PoE Supported) AC 1800 Mbps: Standard The Access Point should be compliant with IEEE 802.3ab, IEEE 802.3u, IEEE 802.3az IEEE 802.11a/b/g/n/ac/ax Wave 2 wireless interface The Access Point support WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, internal RADIUS server The Access point should support MU-MIMO slices through congestion, reducing wait time for all users, Support Wi-Fi 6 delivers greater network efficiency and lower latency, with nearly four times the capacity of previous Wi-Fi standards The Access Point should be compliant with IEEE 802.3af and 802.3at for providing PoE based power UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in The Access point should support Band Steering makes sure connected devices get the best available frequency band Interface and antenna Minimum 2 x dual-band internal antennas 3.2 dBi antenna for 2.4 Ghz & internal 4.3 dBi antenna for 5 Ghz Support 2.4 - 2.483 GHz, 5.15 - 5.35 GHz, 5.47 - 5.85 GHz Access Point should provide Maximum Output Power 23 dBm in 2.4 GHz band & 26 dBm 5 GHz band: Access Point should support Up to 1800 Mbps Access point must have 1 x RJ45 console port for Debugging, 1 x 10/100/1000 Ethernet (PoE) LAN, factory reset, power input Management The AP should support Software controller and Hardware controller of same OEM The Access point should support SNMP v1, v2c, v3 The Access point should have support for Other Features Fast Roaming Support with 802.11k,802.11v, and 802.11r and Passpoint Hotspot 2.0 Support Security & Certification WPA-Personal, WPA-Enterprise, WPA2-Personal, WPA2-Enterprise, WEP 64/128-bit encryption, SSID broadcast disable, MAC address access control, Network Access Protection (NAP),ARP spoofing prevention, WLAN partition The Access point support Local/POP3/RADIUS/PassCode/LDAP authentication for captive portal The Access point should have built-in internal RADIUS server allowing users to create their accounts within the device itself Telnet • Secure Telnet (SSH) • Web (HTTP), Secure Socket Layer (SSL), Traffic control, SNMP v1/v2c/v3 , The AP should have Maximum Power Consumption • 16 W Temperature • Operating: 0 to 40°C (32 to 104°F) • Storage: -20 to 65°C (-4 to 149°F) FCC, CE, MTCTE The AP should be supplied with Wall and ceiling mounting bracket 33 Network Item: Outdoor wireless AP Gigabit LAN(PoE Supported) AC 1100 Mbps: Standard The Access Point should be compliant withIEEE 802.11a/b/g/n/ac/ax, IEEE 802.3u/ab, IEEE 802.3az Energy-Efficient Ethernet (EEE), IEEE 802.3at PoE, Wave 2 wireless interface The Access Point support WPA-PSK/WPA2-PSK/WPA3-PSK & Enterprise and RADIUS client, and Cipher negotiation, SSID broadcast disable, MAC address access control, internal RADIUS server The Access point should support MU-MIMO slices through congestion, reducing wait time for all users, Support Wi-Fi 6 delivers greater network efficiency and lower latency, with nearly four times the capacity of previous Wi-Fi standards The Access Point should be compliant with IEEE 802.3af and 802.3at for providing PoE based power The Access point should support Band Steering makes sure connected devices get the best available frequency band Interface and antenna Minimum 2x2 internal PIFA dual band toatl 4 antenna design with high power & performance 5 dBi (2.4 GHz), 7.3 dBi (5 GHz) Support 2.4 - 2.483 GHz, 5.15 - 5.35 GHz, 5.47 - 5.85 GHz UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in Access Point should provide Maximum Output Power 23 dBm (2.4 GHz), 22 dBm (5 GHz) Access Point should support Up to 3000 Mbps , Up to 574 Mbps for 2.4 GHz and up to 2402 Mbps for 5 GHz Access point must have 1 x RJ45 console port, 1 x 10/100/1000/2500 Ethernet (PoE) LAN port, factory reset button Management The AP should support Software controller and Hardware controller of same OEM The Access point should support SNMP v1, v2c, v3 Security & Certification SSID broadcast disable, MAC address access control, Network Access Protection (NAP),ARP spoofing prevention, WLAN partition The Access point support Local/POP3/RADIUS/PassCode/LDAP authentication for captive portal The Access point should have built-in internal RADIUS server allowing users to create their accounts within the device itself Telnet • Secure Telnet (SSH) • Web (HTTP), Secure Socket Layer (SSL), Traffic control, SNMP v1/v2c/v3 , The AP should have Maximum Power Consumption 14.07 W by ADP, 16.7 W by PoE The AP should be IP68 water and dust-proof housing for outdoor environments Weather resistant from temperatures between Temperature Operating: -30°C and 60°C The AP should should have Breathable pores to repel liquid water while allowing for heat and humidity dissipation FCC, CE, T for certifying the conformity of telecom products with established standards in India The AP should be supplied with Wall and Pole mounting bracket The Wiless AP and PoE switch should be from same OEM 34 24 Port Switch 10/100/1000 Managed PoE Switch Port Configuration & Hardware Interfaces Switch should have 24x 10/100/1000BASE-T ports Ports with 4 10G SFP+ ports for uplink purpose Switch should have Console Port (RJ-45) for out-of-band CLI management, provide a direct, physical connection to the switch for management tasks, which can be especially useful if remote management is not possible Switch should have 16K MAC Address and 12MB Packet buffer memory Switch should have 128 Gbps Switching capacity and 95 Mpps packet forwording rate Power Support and Energy Efficiency: The Switch should support Power Input 100 to 240 VAC 50/60 Hz with Maximum Power Consumption should be not more than 30 W , while Standby Power Consumption should not be more than 9 W The Switch Operating Temperature should be -5 to 50 °C (32 to 122 °F) with Storage Temperature • -20 to 70 °C (-40 to 158 °F) The Switch should support Surge Protection upto 6 kV surge protection on all Ethernet access ports Switch should support Energy-Efficient Ethernet (EEE) standard and save power with shutoff LED and port shut-off and power on link while there is no activity and draw power only as per cable length used , Also the complete switch can be hibernet during off period i.e. Night to save power. Layer 2 Features Switch should support 802.3x Flow Control with HOL blocking, Switch should support 802.1D, 802.1w , 802.1s. It also support Root Guard and Loop Guard UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in Switch should support jumbo Frame: up to 12 Kbytes Switch should support 802.1AX Link Aggregation, Max. 8 groups per device, 8 ports per group Switch should support Port Mirroring ( One-to-One, Many-to-One) , also Supports Mirroring for Tx/Rx/Both, Switch should support Remote Switched Port Analyzer, to takes a mirrored copy of network traffic from within the switch to be sent to a destination. Layer 3 Features Switch should support 4 IP interfaces , support Static Route,124 IPv4 static route entries • 50 IPv6 static route entries QoS (Quality of Service): Switch should support Queue Handling Strict Priority (SP), Weighted Round Robin (WRR) and Strict + WRR , Bandwidth Control with min granularity 10/100/1000 is 16 Kbps) Switch should support QoS based on Time , CoS , Switch port, Inner/outer 802.1p Priority , MAC address, Ether Type, IP address, ToS/IP Preference, DSCP, Protocol type, TCP/UDP port, IPv6 Traffic Class, Security Features: Switch should support 64MAC addresses per port for connected devices, thus preventing unauthorized access and mitigating security risks. Switch should support Broadcast/Multicast/Unicast Storm Control for effectively manage and mitigate the impact of excessive traffic on their network infrastructure, ensuring optimal performance and reliability by using any specifc protocl. Switch should support DHCP Server Screening to prevent rogue DHCP servers from distributing incorrect or malicious IP configuration information to network switch should support Dynamic ARP Inspection to avoid traffic interception, packet sniffing, or denial of service attacks. Switch should support IP-MAC-Port binding in assiociation with IP Source Guard, DHCP snooping and Dynamic ARP Inspection (DAI) Switch should support SSL, TLS 1.0/1.1/1.2, SSH OAM and AAA services Switch should support Cable Diagnostics, Certifications / 3rd Party Approval: The Switch should carry Safety Certifications i.e. cUL, CB, CE, CCC, BSMI and EMI/EMC certification i.e. CE, FCC Class A, C-Tick, VCCI, BSMI, CCC The Switch should carry MTCTE certificate for certifying the conformity of telecom products with established standards in India 35 Network Item: Outdoor wireless AP LAN(PoE Supported) AC 300 Mbps with poe injector Encryption WEP 64/128 bit Encryption Series PoE Series Model Wireless PoE Outdoor 2.4 GHz Networking Antenna 2 dBi Antenna Wireless Speed 300 mbps Transmit Power 29.55 dBm Frequency Band 2.4-2.4835 Ghz Compliance Supported Standards IEEE 802.11 b/g/n, IEEE 802.3u, IEEE 802.3, IEEE 802.3af 36 24 port sfp switch l3 switch manageable switch: UNIVERSITY COMPUTER CENTRE MOHANLAL SUKHADIA UNIVERSITY, UDAIPUR Email: dcc@mlsu.ac.in ; website: www.mlsu.ac.in a) 24 x SFP ports • 2 x 10GBASE-T ports • 4 x 10G SFP+ ports b) DPS-500A c) 10/100/1000BASE-T RJ-45 port for out-of-band CLI management consol port d) 10/100/1000BASE-T RJ-45 port for out-of-band IP management e) stacking port :- 4 f) USB Ports • 1 x USB 2.0 Type A port g) Switching Capacity • 168 Gbps 64-Byte Packet Forwarding Rate • 125 Mpps h) Packet Buffer Memory • 2 MB i) MTBF (Hours):487,153 hours j) Power Input • 100 to 240 VAC, 50 to 60 Hz k) Operation Temperature • 0 to 50 ˚C (32 to 122 °F) l) Storage Temperature • -40 to 70 ˚C (-40 to 158 °F) m) Operating Humidity • 10% to 90% RH n) Storage Humidity • 5% to 90% RH o) Emission (EMI) • FCC Class A, CE Class A, VCCI Class A, IC, RCM, BSMI, CCC p) Safety • CB, CUL, BSMI, CCC 37 ONU (Optical Network Unit) | Fibre Device | Match LB-Link It takes the PTMP (point to multi-point)network topology, effectively collects and converges scattered Ethernet services, and provides the 10/100/1000M Etherne; monitoring, fault isolation and security management, etc. It supports remote management through OLT and local console management as well. standard RJ45 interface smoothly interconnects with existing networks. protocol based on IEEE 802.3 ah, including configuration, alarm, performance. The Dynamic Bandwidth Allocation (DBA) mechanism enables all users to share up to 1.6Gbps bandwidth reasonably, guaranteeing a reliable QoS. Full management through an Operation Administration Maintenance (OAM) Supports IGMP multicast, effective use of broadband; Supports multicast VLAN; Supports FEC and DBA; Supports IEEE802.1Q VLAN protocol. 38 Long Range Smart Manage Outdoor CPE 12dBi, 5km+|Point to Point Wireless Bridge | Fast Ethernet PoE Ports | AP/Station/WISP/P2MP/Repeater/Router | 6KV Lightning Protection,White
|