Dresswoman Lease Description: Assembly And Disassembly Of Dressing Room Measuring 4M X 4M, With Closure In Ts Formicated Plates With Access Door, Air Conditioned, Carpet Coated Floor, Lighting And Electrical Installation, According To The Architectural Design Of The Event. Monitoring Tower Structure Description: Measuring 2, 20 X 1, 60 X 2 Meters High, Aluminum Structure, Fitting Floor, Railing And Coverage. Silent, With A Minimum Capacity Of 180 Kva, Three -Phase, Voltage 380/220 Watts, 60 Hz, With Fuel, Operator And Electrical Cables For Connection, All Food, Hosting And Others (Operators And Other Employees) Are Up To The Company. Contracted, As Well As Fuel Used By The Equipment During The Execution Of The Event., Large Lighting Rental Description: 01 Lighting Table 3072 Dmx Channels, 12 Cob 200W Reflector With Bandoor, 36 Par Led Outdoor, 30 Moing Beam 200, 06 Mini Brut, Each With 04 Lamps, 02 3000W Dmx Smoke Machines, 06 Led Ellipsoidal With Iris From 23 ° To 50 ° Degrees, 08 Strobo Atomic Led Rgb, 08 Ribalta P5 Led, Jet Co² Kit With 4 Nozzles, 02 Cannons Follower. Note: All The Accessories Needed To Serve The System., Large Stage Rental Description: In Anodized Aluminum Structure Q50 Stage Floor (Platform) In Metal Structure With 18Mm Naval Plywood All -Carpet With Black Carpet, Ground Height Of 1 , 60Cm To 2, 00M, With Truss Coverage Of Hard Aluminum Two Water Shape, Structure For P.A. Fly, With Side And Rear Closure In Anti -Flame Synthetic Canvas, With Grounding And Access Ladder With Non -Slip Steps, As Determined By Organs Competent Note: The Assembly Will Obey The Architectural Project Of The Event., 01/28/2025, Medium -Sized Stage Rental Description: In Anodized Aluminum Structure Q30 Stage Floor (Platform) In Metal Structure With 18Mm Naval Plywood Black Carpet, Large Sound System Rental Description: 01 Digital Sound Mixing Table, With 64 Mono Input Channels, 8 Stereo Channels, 3 Trader Sessions, 04 Parametric Equalization Bands, Compressor And Gates And All Channels Of Entry, 08 Effects Processors, 16 Graphic Equalizers Of 31 Operational Bands, 24 Auxiliary Outputs With 04 Parametric Equalization Bands And Adjustable Delay By Output. 01 Multicabo With 48 Roads + 08 Roads For Auxiliaries, With Spliter And At Least 70 Meters. 02 System Processor With 04 Aes/Ebu Digital Inputs With Graphic Equalizer, Gain And Delay For Each Input, 08 Aes/Ebu Digital Outputs With Parametric Equilizations, Gain, Phase And Adjustable Delay For Each Output. 01 Spectrun Analyzer? Of Octaves, 31 Bands With Calibrated Condenser Microphone. 01 Intercommunication System Between Pa And Monitor With 01 Master Unit, Call Light And 02 Headset Phone Stations. 01 Cd Breeder (Compact Disc And Mp3) 50 Cable Protectors, With Ramp Cap, With 05 Internal Channels. 01 Ac Central With Distributors For The Entire System And Cabling For Interconnection To The Generator/Transformer At Least 50M. 24 Passive, Industrial Manufacturing, High Efficiency Array Acoustic Boxes That Reproduce 03 Frequency Ranges, With 2 15 Speakers For Bass With Minimum Continuous Power And 8000W Of Peaks, 4 8 ”Speakers 4” Speakers 4 ” To
|