Sound Rental For Small Events. Lectures, General Meetings In Open And Closed Places. 04 Of Active Acustic 60 Hz To 15 Khz Boxes, With 1 Titanium Drive. 2 Speaker Of 15. 12 Channel Speech Table. 6 Microphone Pedestals. 6 Microphone With Wire 01 Wireless Microphone, Included Cables And Connections For Proper Operation. :, Brigadist: Fixture Brigadista In The Fire Department, Uniform With Documentation Up To Date, To Work In The Civil Security Area, Prevention And Fight The Panic And Fire At Events, With Functions And Records According To The Law. Medical Stage Searing Palt 06 M X 06M, Ceiling Stage 2 Waters In Structure P 30 In The Right And Ceiling, 25 Mm Naval Plywood, With Minimum Height Of 1, 80 M In Relation To The Ground And Linoolio Lining.02 Towers Of Pa M Q30. Pe Ceiling Right Should Be At Least 08 Meters High, Covered With Anti-Flame Canvas, Sides Closure And Proper Canvas, Black Orthophonic And Total Protection Against Rain And Other Weather, Ramp And Ladder On The Sides Compliance In Accordance With The Demands Of The Military Fire Department Of The State Of Minas Gerais, A Minimum Height Of 1, 30 M Height, With Crashes To Avoid Falling. Grounding Of The Stage According To Nbr Standards. - 02 (Two) Camarins In Measure 4 M X 4 M. 03 Fire Extinguisher Dry -Chemical, Nominal 12Kg Capacity, Bc Class, With Intact Inviolability Seal, With Seal Compliance With Inmetro, Meeting The Abnt Standards. :, Large Stage Rental Stage 12 M X 10M, Stage 2 Waters In Structure P 30 In The Right And Ceiling, 80 M In Relation To The Ground And Linolio Lining. 02 Pa Towers In Q 30 Pe Ceiling Right Should Be At Least 10 Meters High, Covered With Anti -Chum Canvas, With Crashes To Avoid Falling. Grounding Of The Stage According To Nbr Standards. - 02 (Two) Dressing Rooms 4 M X 4 M With Floor And 01 Grid In Q50 Measuring 10X08 With 03 Lines. 05 Dry -Chemical Fire Extinguisher, With Seal Compliance With Inmetro. 02 Pa Towers In Q30. Pe Ceiling Right Should Be At Least 10 Meters High, With Crashes To Avoid Falling. Grounding Of The Stage According To Nbr Standards. - 02 (Two) Dressing Rooms 4 M X 4 M With Floor And 01 Grid In Q50 Measuring 07X06 With 01 Line. 03 Polyum Dry Fire Extinguisher, 01/28/2025, Large Sound Rental Rental With The Following Characteristics: P.A Should Contain 120 Db Measured On Scale (A) Reaching A 110 Degree Vertical Coverage 24 Subsida Severe 2X18 3000 Wats Each In The Frequency Response Of 38Hz -180Hz (-3) 146 Db Level By Acoustic Box. 24- 1320 Wats Serious Medical Medical Mediate Boxes Each In The 80Hz-20Khz (-3) 134 Db-Level Printing Of 80Hz-20Khz (-3), It Should Contain 2, It Should Contain 2, Should Contain 2, Should Contain 2 12-Inch Speakers 600 Wats Each P.A Should Contain 08 System Power Racks Plus 02 Stand By, Each Rack Should Contain 4 Amplifier Units In The Following Description: 10- Stereo 15,000 Wats Amplifiers For (Sub) For Severe 1.2 Homos 10- Stereo Amplifiers 10,000 Watsrms For (High Medium) At 1.2 Homs 10 Stereo 5000 Watsrms For (Driver) In 2 Homos All Amplifiers Must Contain Dsp System.
|