Construction Work Of Roof Of Rooms (Brick Coba) And Other Works In Composite School Duhai (U Dias Code-09090901402) - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead as per DSR-2023 S.I.No.15.56. 2 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge in cement mortar as per DSR-2023 S.I.No.15.7.4. 3 Demolishing OF rcc Work manualiy/ mechanically means including stacking of steel bar & serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge in cement mortar as per DSR-2023 S.I.No.15.3. 4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Under Floor) as per as per DSR-2023 S.I.No. 2.25 (a) 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. as per as per DSR-2023 S.I.No. 2.27 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) As per DSR-2023 S.I.No. 4.1.8 7 Providing & fixing PVC pipes conforming to IS make working pressure 6 Kg/cm² including testing, labour, T&P and all complete fittings. 110mm dia as per UPPWD Aligarh SOR CH.23 Item No.32(ii) 8 Brick work with common burnt clay (non modular) bricks of designation-7.5in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) as per DSR-2023 SI No- 6.1.1 9 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) as per DSR-2023 S.I.No.6.4.1. 10 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). Above Plinth Lvl as as per DSR-2023 S.I.No.-5.3 11 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.as per as per DSR-2023 S.I.No. 5.22.6 C. 12 Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.In grantings, frames, guard bar, ladder, railing, brackets, gates and similar works as per as per DSR-2023 S.I.No. SI no. 10.25.2 13 12 mm thick cement plaster of mix 1:4 ( 1 cement & 4 coarse sand )Below Plinth as per as per DSR-2023 S.I.No. 13.4.1 14 12 mm thick cement plaster of mix 1:3 ( 1 cement & 4 coarse sand) a floating coat with neat cemenyas per DSR-2023 S.I.No.13.7.1 15 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to 1.8. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete. Size of Tile 600x600 mm as per SI no 11.41.2 16 Tile work in skirting, risers of steps and dado up to 2 m height over 12 mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm, including pointing in white cement mixed with pigment of matching shade complete.8 mm thick Marble tiles (polished) Raj Nagar as per DSR-2023 S.I.No.18.22.1.1. 17 Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer,over the plasterd wall surface even and smooth surface as perDSR-2023 S.l. No.13.80 18 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture asper DSR-2023 S.I.No.13.62.1 19 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre as per DSR-23 S.l.No.13.41.1 Two Coats 20 Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) as per DSR-2023 S.l. No.13.46.1 Two Coats 21 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. As per SI-12.22 22 Centering and shuttering including stutting, propping etc. and removal of form.Slab as per SI- 5.9.3 23 Centering and shuttering including stutting, propping etc. and removal of form.Beam /Band as per SI- 5.9.5 24 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 10 Km lead, for all leads including all lifts involved. as per DSR-2023 S.I.No.1.1.18. 25 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, D6:D34modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required as per DSR-2022(E&M) S.I.No.1.10.1. 26 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireas per DSR-2022(E&M) S.I.No.1.14.2. 27 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire as per DSR-2022 (E&M) S.I.No.1.14.3. 28 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire as per DSR-2022(E&M) S.I.No.1.14.10. 29 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. as per DSR-2022(E&M) S.I.No.1.31. 30 SupplyingandfixingsuitablesizeGIboxwithmodularplateandcoverinfronton surfaceorinrecess,includingprovidingandfixing6pin5/6&15/16Amodular socket outlet and 15/16 A modular switch, connections etc. as required as per DSR-2022(E&M) S.I.No.1.32. 31 Supply and fixing ofrecess/ Surface/ Pendentmounting round10 to 15 Watt LED Down Lighter having Powder coateddie cast aluminium housing withheat sink, diffuser/ Reflector and driver set complete in all respect.. CAT-AA as per UPPWD SOR (E&M)-2018 S.I.No.1402. 32 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00,Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. as per DSR (E&M)-2022 S.I.No.19.1. 33 Supply and fixing of 300mm sweep exaust fan. Rate approved by S.E.R.E.D.Meerut Letter No.07 dated 03.04.2023. 34 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Rate approved by S.E.R.E.D. Meerut by Letter No.07 dated 03.04.2023. 35 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole as per DSR-2022(E&M) S.I.No.2.10.3. 36 Supplying and fixing of 63 Amp. 4 Pole MCB (10KA) "C" curve, CAT-A as per UPPWD (E&M)-2018 S.I..No.1020(A).
|