Stationary Oxygen Concentrator With Noise Level Up To 50 Dba, 220 V Power Supply, With Handle For Transport And Wheels For Movement, With Support For Humidifier. Flow Meter Per Liter Of Up To 5 Liters Per Minute. Oxygen Purity Of At Least 87% With Oxygen Percentage Indicator System And Low Oxygen Level Detection Alarms. Average Power Consumption Up To 400 W. Includes Air Intake Filter. Maximum Weight Of 20 Kg. Accompany Backup Cylinder With Regulating Valve With A Capacity Of 1 M³ To 4 M³ Of Medicinal Oxygen, As Requested By The Municipal Health Department, With The Following Disposables: Humidifier Cup And Nasal Catheter. Concentrator And Cylinder In Lease. Stationary Oxygen Concentrator With Noise Level Up To 50 Dba, With The Following Disposables: Humidifier Cup And Nasal Catheter. Concentrator And Cylinder In Lease., Stationary Oxygen Concentrator With Noise Level Up To 60 Dba, With Support For Humidifier. Flow Meter Per Liter Of Up To 10 Liters Per Minute. Oxygen Purity Of At Least 87% With Oxygen Percentage Indicator System And Low Oxygen Level Detection Alarms. Average Power Consumption Up To 550 W. Includes Air Intake Filter. Maximum Weight Of 20 Kg. Accompany Backup Cylinder With Regulating Valve Capacity From 1 M³ To 4 M³ Of Medical Oxygen, According To 1 M³ To 4 M³ Of Medical Oxygen, With The Following Disposables: Humidifier Cup And Nasal Catheter. Concentrator And Cylinder In, Charge Of Medical Gaseous Oxygen Minimum Purity Of 99% For Backup Cylinder, To Meet Any Refills Of Items 1 And 2, With Capacity From 1 To 4 M³, Including Delivery To The Location That Will Be Informed And The Cylinder In Lease, For Use By Patients Registered With The Municipal Health Department. Unit Of Measurement: Cubic Meters. Medical Gaseous Oxygen Charge Minimum Purity Of 99% For Backup Cylinder, For Use By Patients Registered With The Municipal Health Department. Unit Of Measurement: Cubic Meters., Portable Oxygen Concentrator Must Have Ac Power Cable, Dc Power Cable, Rechargeable Lithium Ion Battery, Bivolt, Oxygen Concentration 93% +/- 3%, Pulse Administration Dose Oxygen Purity 1 -6 With Increment Of 0.5, Battery Life Of 3 Hours, Oxygen Purity Alarm Below 83%, Battery Discharge Alarm 17 Minutes Before Full Discharge, Battery Status On Screen And On Battery , No Breathing Alarm After Two Minutes, Oxygen Capacity Of 2L/Min. It Has Pulsed And Continuous Flow Delivery With Continuous Adjustment Autonomy From 0.5 To 0.5 Up To 2L/Min. Concentrator In Lease. Portable Oxygen Concentrator Must Have Ac Power Cable, 5 To 2L/Min. Concentrator In Lease., Load Of Medical Gaseous Oxygen Minimum Purity Of 99% For Backup Cylinder With A Capacity Of 0.7 M³, Including Delivery To The Location That Will Be Informed And The Cylinder In Lease. Unit Of Measurement: Cubic Meters. Medical Gaseous Oxygen Charge Minimum Purity Of 99% For Backup Cylinder With Capacity Of 0, Including Delivery To The Location That Will Be Informed And The Cylinder In Lease. Unit Of Measurement: Cubic Meters., 01/24/2025, Load Of Medical Gaseous Oxygen Minimum Purity Of 99% For Backup Cylinder With A Capacity Of 1 M³, For The Use Of Services Provided By The Municipal Health Department And Fire Department. Unit Of Measurement: Cubic Meters.Ga Oxygen Charge
|