Tender For Addn/Altn And Extension To Conference Hall At Afs Kanpur; 1 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. 2 All as per item No 1.00 but depth exc 1.5m but n.exc 3.0 m 3 Demolition ofcement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 4 Dismantlingof Brick work / stone masonry built in cement mortar complete all as specified and directed. 5 Taking down chowkat with shutter (without takingoff shutter from frame) n exc 1.5 sqm each complete all as specified and directed. 6 M & L for cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. 7 M&L Damp proof course in 40 mm thick cement concrete1:2:4, type B-0 (using 12.5 mm gradedstone aggregate) to horizontal or vertical surfaces including necessary formwork complete all as specified and directed 8 M&L for brick work with burnt sub class "B" bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. Brick work should be in proper horizontal and vertical alignment and mortar thickness should not be greater than 12mm. 9 M&L for RCC nominal mix (1:1.5:3) using 20 mm graded stone aggregate as in Foundations, including rafts, footings,foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete , complete all as specified. Concrete should have defined consistency and properly mixed as directed on site. 10 M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; lintel and similar work;vertical or to batter for rough finished surfaces of concrete. Formwork used should be made of new plank of timber with proper battening and bracing 11 M&L Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all specified and directed 12 M&L for RCC nominal mix (1:1.5:3) using 20 mm graded stone aggregate as inchhajjas, lintel beam complete all as specified and directed. 13 M & L for mild steel TMT bars 10 mm dia& over cut to length bent to shaperequired including,crancking, bendingspirally for hooping for columns, hooking ends andbindingwithand including mildsteelwire (annealed) notless than 0.90mm dia or securing with clips,complete all as specified and directed. 14 All as per item No 13above but 6 to 8 mm dia as in stirrups 15 Providing and fixing factory made uPVC white colour Sliding window exc 2 sqm Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. Note: Glass shall be mesured and paid separately in appropriate item. 16 M&L for sheet glass 4.0 mm thickordinary quality in square exec 0.5 Sqm in each pane fixed in UPVC window as in item No 15 above complete all as specified and as directed. 17 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed 18 S&F Pre- painted puff pannel of overall thickness 50 mmsandwich withHR galvanised corrugated sheet of grade Fy 345 MPA and centre portion of expanded poly styrelene, with compressive strength of 2.1 kg/cm2 and tensile strength of 3.7 Kg/cm2, fire resistance and accoustic proof complete all as specified and directed. 19 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick, AZ 150 of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed 20 M&L for rendering 15mm thick on fair faces ofbrick work or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed. 21 M&L for rendering 15mm thick on other than fair faces ofbrick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed 22 M & L for hardcore of broken stone or boulders ofgauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed 23 M&L for 100 mm thick cement concrete type D- 2, 1:4:8( using 40mm graded stone aggregate) as in sub base complete all as specified and directed. 24 M&L for 25 mm thick Cementconcrete type B-1, 1:2:4 (using 20mm graded stone aggregate)complete all as specified and directed. 25 M & L for 75 mm thick cement concrete type C- 2, 1:3:6( using 40mm graded stone aggregate) as in plinth protection complete all as specified and directed 26 M & L for preparation of new undecorated surfaces of walls and applying two coat of Oil Bound Distemper over a coat of primer and 1mm thick wall care putty complete all as specified and directed. 27 M & L for preparing new or undecoratedplastered surface and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and as directed. 28 M&LVirified Ceramic tiles light shade 8-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including15 mm thick screed bed of CM (1:4) complete all as specified and directed. 29 M&L 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed (Note : Moulding on edge is deemed to be included in the quoted rate) 30 Returning, filling in, including spreading, levelling, watering & well ramming in layers n exc 25 cm with any type of soil complete all as specified and directed 31 Removing excavated material exc. 1.50 km but n exc. 5km and depositing where directed complete all as specified and directed 32 M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. 33 Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e.light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge. 34 M & L for concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements withPVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of paris/Putty or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for one light, fan, exhaust fan, call bell. 35 -Ditto- all as per item No 34.00 here-in-before but For one socket point controlled by one switch on independentboard. 36 -Ditto- all as per item No 34 here-in-before but For one socket point controlled by one switch on same board. 37 All as per item No 34 here-in-before but for power point wiring with 2.5 SqmmPVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead. 38 M & L,modular switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified. 39 M & L,modular switch flush type 15 Amps, 240 Volts single pole white finish complete all as specified. 40 M&L, modularsocket outlet 5 pin, 5 Amps flush type white finish complete all as specified. 41 S&F, mosular socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete all as specified. 42 S&F ceiling rose, surface backlite, 65 x 20 mm three terminal complete all as specified and directed. 43 S&F modular metal flush box 3 module complete all as specified and directed 44 S&F modular metal flush box 6 module complete all as specified and directed 45 S&F modular metal flush box 8 module complete all as specified and directed 46 S&F modular metal flush box 12 module complete all as specified and directed 47 S&F modular white cover plate with frame 3 module complete all as specified and directed 48 S&F modular white cover plate with frame 6 module complete all as specified and directed 49 S&F modular white cover plate with frame 8 module complete all as specified and directed 50 S&F modular white cover plate with frame 12 module complete all as specified and directed 51 S&F,in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed 52 All as per item No 51 above but 4 Way 53 Supply and fixing in repair TPN DB"s 8 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and directed 54 Supply & fixing, testing and commissioning in replacement of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed 55 -Ditto- all as per item No 54 but of SP 40-63 Amps. 56 -Ditto- all as per item No 54 but ofSPN 32 Amps. 57 -Ditto- all as per item No 54 but ofSPN 40 Amps. 58 -Ditto- all as per item No 54 but ofTP 40 / 63 Amps. 59 S & F in repair MCCB 125 Amps capacity, 4 pole, 16 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 8 way TPN DB complete all as specified and directed. 60 S&F in replacement modular sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad boardfixed properly in concealed position all as directed by Engineer-in-Charge. 61 M & Lsub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in new PVC conduitwith 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete.Note : (i)Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.(ii) PVC Conduit if required shall be measured and paid separately under respective item. 62 M & Lsub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduitwith 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete. Note :(i)Two single core cable and one run of earth copper conductor will be measured and paid as one unit length.(ii) PVC Conduit if required shall be measured and paid separately under respective item. 63 S&F rigid non metallic medium white / ivory PVC conduit medium grade ISI markedof size not less than 25 mm dia concealed position on wall and surface in roof/ceiling inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc all as directed by Engineer-in-Charge. 64 S&F in replacement complete for recess mounting LED Panel 600x600 mm fittings made of CRCA powder coated finishLED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenanceCCT UP TO 6500,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt internal surge protection 2.5 KVAS IS 10322 and IEC 60598 system wattage 31 - 36 wattcomplete electronic drivers with all internal electric connections complete all as specified. 65 M&L in replacement forLED Building Security Light 110watt of aluminium PDC housing, glass cover with IP 66 protection complete all as specified and directed 66 M &L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip of 32x6mm (up to 7.5m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shwon in electrical plate no 5 of SSR part 1 including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS bar 8mm dia 150mm c/c reingorcement, watering funnel 40mm dia light grade for protection of earth electrode 20mm dia for watering all as speicified and directed and tested on completion complete all as specified and directed. 67 Material and Labour for 3 core PVC insulated sheathedPVC strandedcopper conductorcable of size 1.5 sqmm 1100 volt grade andPVCinsulated 3 core complete all as specified and directed 68 M&L for XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade 16 sqmm 4 corelaid in trenches/panel or passing through pipe including connecting with suitable lugs, nuts and bolts and testing complete all as specified and directed
|