Tender For Interior, Electrical And Lan Works Of Yerpedu Branch => Limited; I CABLES 1 PVC insulated cables for working Voltage upto and including 1100 V IS 694:1990 2 PVC Insulated (heavy duty) electrical cables IS 1554:1988 3 11 KV XLPE cables I S 7089-partII 4 Recommended current ratings for cables IS 3961-1967 5 PVC insulations and sheath of electric cables IS 5831:1984 6 Conductors for insulated electric cables & flexible cords (superceding IS 1753: 1967) IS 8130:1984 II CONDUITS & ACCESSORIES AND JUNCTION BOXES 1 Flexible PVC conduits for electrical wiring IS 3480:1966 2 Conduits for electrical installation: Part 1 General requirements IS 9537-PI1981 3 Conduits for electrical installation: Part 2 PVC conduits IS 9537-PII1989 4 Accessories for PVC conduits for electrical wiring IS 3837-1976 5 Adopters for PVCconduits IS 4649:1968 III DOMESTIC SWITCHES SOCKETS Plugs and socket outlets (250V; 16A) : Specifications IS 1293:2005 Ceiling Roses – Specification IS 371:1999 Switches for domestic and similar purposes IS 3854:1997 IV ELECTRICAL INSTALLATION code of practice for electrical wiring installation IS 732:1989 code of practice for earthing IS 3043:1987 Recommendations on safety procedures and practices in electrical work IS 5216:1982 Code of practice for Selection, installation and maintenance of fuses (Voltages not exceeding 650 V) IS 3106-1996 code for practice for interior illumination Part2 IS 3646:1966 code of practice for lighting of public thoroughfares IS 1944:1970 Installation and maintenance of paper insulated power cables IS 1155-1967 Code of practice for use of structural steel in General building construction IS:800 Methods of testing uniformity of coating on zinc coated articles IS:2633 Code of practice for phosphate iron and steel IS:6005 V LT PANEL BOARDS / LIGHTING PANELS Enclosed distribution fuse board and cutouts for voltage not exceeding 1000 V AC / 1200 V DC IS 2675-1983 Specifications for Low voltage switchgear and control gear for voltages not exceeding 1000 V. Part-1 General Rules (supercedes IS 4237 & IS 2147) Part-2 Circuit Breakers (supercedes IS 2516) Part-3 Switches, disconnectors (supercedes IS 4064) Part-4 Contractors, starters (supercedes IS 2959) IS 13947:1993 Part-5 Control circuit devises & switching elements ( supercedes IS 6875 switches/ push button) IS 13947:2004 Code of practice for climate for climate proofing of electrical equipment IS 3202:1965 Electrical accessories- Circuit breaker for over current protection for house hold & similar installations ( Miniature Air-bread circuit breakers for voltage not exceeding 1000V) IS 8828:1996 Current transformers IS 2705:1992 Low voltage fuses (upto 1000V) IS 13703:1993 Supercedes IS 2208 & IS 9224 Wrought aluminium and aluminium alloy bars, rods, tubes and sections for electrical purposes IS 5082: 1998 Specifications for low voltage switch gear and control gear assemblies (i.e. Factory build assemblies of switchgear and control gear for voltages up to 1000 V) IS 8623:1993 Electrical measuring Instruments (Direct acting indicating analog instruments) & accessories IS 1248:2003 Danger notice plates IS 2551:1982 Guide for Marking insulated conductors (supercedes IS 375) IS 5578-1984 Guide for uniform system of marking & identification of conductors and apparatus terminals IS 11353:1985 Electrical relays for power systems protections IS 3231:1986 Voltage Transformers (part 1 to part 4) IS 3156:1992 Electricity meters induction type (for alternating current) IS 722:1986 Inter connecting Bus-bars for Voltage above 1KV IS 8084-1976 VI LIGHTNING Code of practice for the Protection of buildings and allied structures against lightning S 2309-1989 VII FIRE SAFETY Code of practice for Fire safety of buildings (General) Electrical Installation IS 1646-1997 VIII LIGHTING FIXTURES AND ACCESSORIES General and safety requirements for electric Lighting fittings IS 1913-1969 Interior Illumination IS 3636-1966 tubular florescent lamps IS: 2418:1977 Bal lazes for use in florocent lighting fittings (part 1) IS: 1534 bi-pin lamp holders for tubular florocent lamps IS: 3323 capacitors for use in florocent lighting fittings IS: 1569 starters for florocent lamps IS: 1522 holders for starters for tubular florocent lamps IS: 3324:1982 specifications for decorative lighting out fits IS: 5077 high-pressure mercury vapour lamps IS: 2183 GLS lamps IS: 416 Bayonet lamp holders IS 1258:2005 dust proof electric lighting fittings IS :4012 dust tight electric lighting fittings IS:4013 specification for floodlights IS: 1947 Lighting public thorough fares IS 1944-1970 Luminaries for street lighting IS 2149-1970 Water tight electric lighting fittings IS 3553-1966 Waterproof electric lighting fitting IS 3528-1966 industrial lighting fittings IS: 1777 industrial lighting fitting with plastic reflectors IS:3287 IX CEILING FANS Electrical ceiling type fans & regulators IS 374-1979 X TRANSFORMERS IS 2026-1962 Installation and commissioning of transformers IS 1886-1967 XI Onload change over switches IS 4064-1978 Tubular steel poles for overhead power lines IS 2713:1980 Mild Steel wire for General Engineering purpose IS 280:2006
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 91596620
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.