Tender For Various Activities Of Development Of Distribution Infrastructure At Jhalawar Circle Of Jaipur Discom Of Rajasthan State Under Rdss On Turnkey Basis Against Tn-588 - Supply of material for the various activities of development of distribution infrastructure at Jhalawar Circle of Jaipur Discom of Rajasthan state under RDSS on turnkey basis. Sl. No. Item Description 1 (A)Bifurcation of 33 KV Line due to overloading 2 33 KV OVERHEAD LINE WORK 3 PCC Poles 4 PCC Pole 9 mtrs long (400 KG) 5 12.8 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 6 33 KV "V" cross arms with TOP Hamper made of MS Angle75X75X6 mm with clamp of size 50X10 mm,earth clamp50X6 mm with nuts, bolts & Washers as per latest specification and drawings adopted & approved by Nigam (Galvanized as per IS) 7 A SET OF 4 NOS. 33KV "V" CROSS ARMS(CHAKRI) MADE OF M.S. CHANNEL 100X50 MM ISMC [9.56 KG PER MTRS.] ON THE EXISTING LATTICE TOWER WITH BRACING OF M.S. FLAT ( 50 X 10 MM) INCLUDING NUT AND BOLTS ETC. WEIGHT OF THE ITEM WILL BE AS PER DRAWING 8 A set of 4 NOS. 33 KV "V" cross arms (Chakri) made of M.S.Angle 75x75x6 mm with bracing of M.S.Flat 50 x 10 mm including all necessary clamps, nuts & bolts etc. (Galvanized as per IS) 9 M.S. CHANNEL [CUT POINT ] 100X50 MM ISMC [9.56 KG. PER MTR] 2X1.8 MTRS LONG WITH PILOT PATTI 50X6MM [2.36 Kg. per mtr] THICK AND NECESSARY NUTS AND BOLTS ETC. WEIGHT OF THE CUT POINT CHANNEL WILL BE AS PER DRAWING APPX. 39.00 Kg. (Galvanized as per IS). 10 33 KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (Galvanized as per IS) 11 33 KV PORCELAIN PIN INSULATOR WITH PIN ON EXISTING POLE COMPLETE INCLUDING ALL ACCESSSORIES LIKE HARDWARE FITTING AND NUTS AND BOLTS ETC. 12 GS Stay set complete with 20 mm dia., 2.4 meter long stay rod with zinc coated steel Anchor Plate of size 300x300x4 mm with square hole of size 18x18 mm at centre IN GROUND AND GS STAY WIRE 7/8 MM TIGHTENED THROUGH 33 KV STAY INSULATOR INCLUDING CLAMPS 13 GS WIRE NO.6 SWG HOT DIP GALVANIZED [5.0 MM DIA] COMPLETE IN ALL RESPECTS WITH BINDING WIRE EACH POLE WITH TOP HAMPER & CROSS ARM (WITH 1.1 M WIRE). 14 Overhead ACSR 100 Sq.mm. Dog conductor on existing cross arms complete in all respect. (Cost of material includes the sag and jumpering) 15 ACSR Dog conductor 16 PG Clamps for Dog conductor 17 HD GALVANISED M.S.ROD TYPE EARTHING SET MADE UP OF M.S.ROD 20 MM DIA. 3 METER LONG ALONGWITH EARTHING CLAMP & 8 SWG EARTH WIRE 15 METER LONG (FOR EARTHING OF 33 KV LINE) . 18 BACK CLAMP AND STAY CLAMP FOR CROSS ARMS, STAY, EARTH AND GUARDING BRACKET OF MS FLAT 19 33KV DANGER PLATE ON THE TOWERS/ POLES COMPLETE IN ALL RESPECT AS PER DRAWING. 20 ISA M.S. ANGLE 50X50X6 MM (Galvanized as per IS) 21 ISA M.S. ANGLE 65X65X6 MM (Galvanized as per IS) 22 ISA M.S. Flat 50X 6 (Galvanized as per IS) 23 ISA M.S. Channel 100X50X6 (Galvanized as per IS) 24 Fixing of ,45KN. porcelain disc.insulators for 33 KV ( each unit consisting of 3 Nos. disc insulators & 1 Nos.B&S Type hardware) (Free issue by Nigam) 25 (B)Bifurcation of 11 KV Line due to oveloading 26 11 KV Bay 27 Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools 28 Control Cable of size 4C X 4 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules . 29 Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 30 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 31 M.S. Flat 50 X 6 mm (Galvanized) for earthing 32 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length 33 Metering points on 11 KV outgoing feeder at 33/11 KV S/S.(including following cost of (a) and (b) ) 34 (a) Mounting structure (Galvanized) 35 (b) The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. 36 Installation of Metering equipments: 37 11KV CT PT Set(200/5 Amp.) 38 MIP meter boxThe meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box. 39 GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 40 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. 41 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. 42 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 43 PCC Poles 44 PCC POLE 9.0 mtrs long.(200 Kg.) 45 45KN. porcelain disc.insulators for 11 KV ( each unit consisting of disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc. 46 11 KV 5KN composite polymer Pin Insulator complete in all respect 47 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 48 11 kV Danger plate of size 200 X 250 mm complete in all respect 49 M.S Channel 100x50x6mm 50 M.S Angle 65x65x6mm 51 11 KV UnderGround Cable Work 52 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 53 Under ground Cable of Size 3X185 SQ.MM for 11 KV 54 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 55 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 56 GI PIPE for Cable Support at Tower ( Each 3.3 Mtr ) 57 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 58 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 59 XLPE 3X185 SQ.MM H.S.S.T. JOINT 60 Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 61 11 KV Over Head Line Work 62 PCC Poles 63 PCC Pole 9 mtrs long (200 KG) 64 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 65 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC (9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X50 X 6 MM AND M.S.FLAT 50 X 6 MM(105 KG. APPROX.) (Galvanized as per IS)Total weight 101.38 Kg+4 Kg (Approx.) 66 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 67 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 68 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 69 Earthing rod set for 11 KV lines made with MS rod (Galvanised) 20 mm dia, 3 meter length along 70 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 71 11 KV 5KN composite polymer Pin Insulator complete in all respect 72 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986 73 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 74 11 KV Danger plate of size 200 X 250 mm complete in all respect 75 1.4 Mtr Channel bracket with clamp 76 (C)HVDS works 77 11 KV Overhead Line-1-Phase 78 PCC Poles 79 PCC Pole 9 mtrs long (200 KG) 80 Overhead steel cored aluminum ACSR WEASEL [30 sq.mm (6+1)/(2.59+2.59) mm ]conductor 81 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 82 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 83 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 84 11 KV 5KN composite polymer Pin Insulator complete in all respect 85 LT Porcelain Pin insulators with pins 86 PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) 87 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 88 11 KV Danger plate of size 200 X 250 mm complete in all respect 89 1.4 Mtr Channel bracket with clamp 90 11 KV Overhead Line-3-Phase 91 PCC Poles 92 PCC Pole 9 mtrs long (200 KG) 93 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 94 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC (9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X50 X 6 MM AND M.S.FLAT 50 X 6 MM(105 KG. APPROX.) (Galvanized as per IS)Total weight 101.38 Kg+4 Kg (Approx.) 95 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 96 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 97 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 98 Earthing rod set for 11 KV lines made with MS rod (Galvanised) 20 mm dia, 3 meter length along 99 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 100 11 KV 5KN composite polymer Pin Insulator complete in all respect 101 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 102 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 103 11 KV Danger plate of size 200 X 250 mm complete in all respect 104 1.4 Mtr Channel bracket with clamp 105 11 KV Underground Cable 106 PCC Poles 107 PCC Pole 9 mtrs long (200 KG) 108 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 109 Under ground Cable of Size 3X185 SQ.MM for 11 KV 110 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 111 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 112 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 113 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 114 XLPE 3X185 SQ.MM H.S.S.T. JOINT 115 HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 116 1-Phase DTR 117 PCC Poles 118 PCC Pole 9 mtrs long (400 KG) 119 6.35KV/240 V aluminium wound, conventional outdoor type distribution transformers with all fittings and accessories and first filling of transformer oil alongwith MCCB. Protection on LV side confirming 120 5 KVA 121 10 KVA 122 16 KVA 123 M.S. Flat 50 X 6 mm for mounting single phase transformer on poles. 124 6.35/0.24 KV substation structure for 5 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc. including nut ,bolt,flat and spring washer (as per latest specification and drawing adopted & approved by NIGAM) (36.054 Kg. + 2 Kg. approx.) 125 6.35/0.24 KV substation structure for 10/16/25 KVA complete (galvanized as per IS) complete in all respect made of MS Channel, MS angle and MS flat etc. including nut ,bolt,flat and spring washer (as per latest specification and drawing adopted & approved by NIGAM) (36.054 Kg. + 2 Kg. approx.) 126 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length as per latest specification and drawing adopted & approved by NIGAM. 127 11 KV 100 Amp. Drop out cum isolator with 5.0 Amp. fuse & 12 KV post insulators including nut, bolt & washers as required as per technical specifications, approved drawings and scope of work. 128 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 129 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 130 11 KV 5KN composite polymer Pin Insulator complete in all respect 131 Danger plate of size 200 X 250 mm complete in all respect 132 PG clamps (Weasel to Weasel) made of aluminum alloy as per IS:617-1994 etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 133 3-Phase DTR 134 PCC Poles 135 PCC Ploe 9.0 mtrs long.(400 Kg.) 136 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 137 LT XLPE Cable 138 Size 4CX70 SQ. mm 139 11 /0.4 KV Al wound, Three Phase Distribution Transformer (Completely self protected with provision of LT Bushing Box) 140 25 KVA (Aluminium) 141 40 KVA (Aluminium) 142 63 KVA (Aluminium) 143 100 KVA (Aluminium) 144 M.S. Flat 50 X 6 mm for mounting single phase transformer on poles. 145 LT Supply Pillar Box of 200 Amp. capacity as per specification of Nigam . 146 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 147 11/0.4 KV SubStation structure set on existing poles in all respect with clamps made from M.S. channel 100x50 X6 mm and 75x40 mm, M.S. angle 50x50x6 and M.S. flat 50x6 mm and 50x8 mm weight(166.746 kgs.) Approx (All galvanized as per relevant IS) 148 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 149 LIGHTENING ARRESTOR ( FEEDER TYPE) ON ERECTED STRUCTURE / SUPPORT ( SET OF 3 NOS. ) 150 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length as per latest specification and drawing adopted & approved by NIGAM. 151 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 152 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 153 11 KV 5KN composite polymer Pin Insulator complete in all respect 154 Danger plate of size 200 X 250 mm complete in all respect 155 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 156 (D) Cabling Works in Theft Prone Area 157 LT Ariel Bunch Cable 158 PCC Poles 159 PCC Pole 9 mtrs long (200 KG) 160 Overhead ABC(Aerial bunched cable) with Bare Messenger 161 1C X25 +1CX25 sqmm 162 3C X25 +1CX25 sqmm 163 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 164 Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 165 Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 166 LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2) 167 LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2) 168 Spring loaded box (1 phase) 169 Spring loaded box (3 phase) 170 LT Underground Cable 171 4 Core LT XLPE insulated PVC sheathed armoured Cable 172 Size 4CX120 SQ. mm 173 Size 4CX185 SQ. mm 174 LT DISTRIBUTION BOX AS PER SPECIFICATION OF NIGAM. 175 100 AMP LT DISTRIBUTION BOX 176 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length as per latest specification and drawing adopted & approved by NIGAM. 177 LT Armoured Service Cable 178 2CX4 Sq MM 179 4CX16 Sq MM 180 (E)Segregation of 11 KV Ag-Non Ag Feeders 181 11 KV Bay 182 Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools 183 Control Cable of size 4 X 4 SQ.MM. 1100 Volts PVC Insulated including supplyof ferrules 184 Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules 185 Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing 186 M.S. Flat 50 X 6 mm (Galvanized) for earthing 187 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length as per latest specification and drawing adopted & approved by NIGAM. 188 Metering points on 11 KV outgoing feeder at 33/11 KV S/S.(including following cost of (a) and (b) ) 189 (a) Mounting structure (Galvanized) 190 (b) The requisite steel members will be supplied by contractor including the hardware.Contractor shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor. 191 Installation of Metering equipments: 192 11KV CT PT Set(200/5 Amp.) 193 MIP meter box.The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box. 194 GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 195 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. 196 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. 197 11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 198 PCC Poles 199 PCC Pole 9 mtrs long (200 KG) 200 45KN. porcelain disc.insulators for 11 KV ( each unit consisting of disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc. 201 11 KV 5KN composite polymer Pin Insulator complete in all respect 202 PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising 203 11 KV Danger plate of size 200 X 250 mm complete in all respect 204 M.S Channel 100x50x6mm 205 M.S Angle 65x65x6mm 206 11 KV UnderGround Cable Work 207 PCCPoles 208 PCC Pole 9 mtrs long (200 KG) 209 UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED 210 Under ground Cable of Size 3X185 SQ.MM for 11 KV 211 G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK) 212 GI PIPE for Cable Support at Pole ( Each 3.3 Mtr ) 213 CABLE FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE 214 XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE 215 XLPE 3X185 SQ.MM H.S.S.T. JOINT 216 HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire 15 meter long (for earthing of 11 KV line) 217 Double break without EB Isolator on existing bracket complete in all respect as required including hardware nut, bolts & washer etc. 218 11KV (with 9 x 24 KV Post Insulator ) 400 Amp. - as per latest specification, design & drawing approved by the NIGAM 219 11 KV Over Head Line Work 220 PCC Poles 221 PCC Pole 9 mtrs long (200 KG) 222 11.4 MTR. Long lattice tower made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification 223 11KV DOUBLE POLE LINE STRUCTURE SET FOR CUT POINT COMPLETE ON EXISTING POLES IN ALL RESPECT WITH CLAMP, NUT & BOLTS AS REQURIED MADE FROM M.S.CHANNEL 100 X 50 X ISMC (9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X50 X 6 MM AND M.S.FLAT 50 X 6 MM(105 KG. APPROX.) (Galvanized as per IS)Total weight 101.38 Kg+4 Kg (Approx.) 224 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 225 11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized) 226 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 227 Earthing rod set for 11 KV lines made with MS rod (Galvanised) 20 mm dia, 3 meter length along 228 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 229 11 KV 5KN composite polymer Pin Insulator complete in all respect 230 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 231 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised) 232 11 KV Danger plate of size 200 X 250 mm complete in all respect 233 1.4 Mtr Channel bracket with clamp 234 3-Phase DTR 235 PCC Poles 236 PCC Ploe 9.0 mtrs long.(400 Kg.) 237 Overhead steel cored aluminum ACSR Rabbit conductor in all respect 238 LT XLPE Cable 239 Size 4CX70 SQ. mm 240 11 /0.4 KV Al wound, Three Phase Distribution Transformer (Completely self protected with provision of LT Bushing Box) 241 16 KVA 242 25 KVA 243 40 KVA 244 63 KVA 245 M.S. Flat 50 X 6 mm for mounting single phase transformer on poles. 246 LT Supply Pillar Box of 200 Amp. capacity as per specification of Nigam . 247 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc. 248 11/0.4 KV SubStation structure set on existing poles in all respect with clamps made from M.S. channel 100x50 X6 mm and 75x40 mm, M.S. angle 50x50x6 and M.S. flat 50x6 mm and 50x8 mm weight(166.746 kgs.) Approx (All galvanized as per relevant IS) 249 Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS 250 LIGHTENING ARRESTOR ( FEEDER TYPE) ON ERECTED STRUCTURE / SUPPORT ( SET OF 3 NOS. ) 251 Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length as per latest specification and drawing adopted & approved by NIGAM. 252 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 253 11KV T&C Type composite polymer insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM) 254 11 KV 5KN composite polymer Pin Insulator complete in all respect 255 Danger plate of size 200 X 250 mm complete in all respect 256 PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor, 257 LT Ariel Bunch Cable 258 PCC Poles 259 PCC Pole 9 mtrs long (200 KG) 260 Overhead ABC(Aerial bunched cable) with Bare Messenger 261 3C X25 +1CX25 sqmm 262 GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG 263 Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 264 Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS) 265 LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2)
|