Tender For Provision Of Religious Institute ( Sarv Dharmsthal) At Bathinda Mil Stn. Job No.81/Sa / Btd / Lbw-06 /2021-2022.; 2 GENERAL SUMMARY 3 Lump sum price worked out by the contractor for BUILDING/ STRUCTURE WORKS as listed in Schedule ‘A’Part- I (Ref prepriced schedule attached seperately) 4 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately) 5 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately) 6 Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKSas listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately) 7 Lump sum price worked out by the contractor for EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’Part-V(Ref prepriced schedule attached seperately) 8 SCH "A" Pt - VI (MISCELLANEOUS ITEMS) (Contains Ser item No 3.01 to Ser item No 6.02) 9 INTERNAL ELETRIFICATION WORKS NOTE:- For items of internal Electrifications Works notes given at the beginning of Sch ‘A’ Part-II (internalElectrification works) shall also be applicable. 10 Material and labour for concealed Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), inPVC conduit complete with 1.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through withand including PVC rigid conduit 20mm dia ( heavy duty )ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories) with all fittings and all accessories i.e pipe bend pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ), 3mm thick bakelite plastic laminated sheet for mounting with frame and top cover forswitches and socket ,fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etccomplete all as specified and as directed by Engineer-in-charge.Note for serial item no.3.02 to 3.05 :switches ,sockets&fan regulator shall be measured and paid seperately under respective items of Schedule"A" BoQ. 11 All as per item No. 3.02 here in before but for socket outlet 5 pin 5/6 Amp on same boardcomplete all as specified and directed by Engineer-in-charge. 12 All as per item No. 3.02 here in before but for socket outlet 5 pin 5/6 Amp on independent boardbut not below the switch board, complete all as specified and directed by Engineer-in-charge. 13 All as per item No.3.02 here in before but for socket outlet 6 pin, 15/16 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable &including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth, complete all as specified and directed by Engineer-in-charge. 14 Material and Labourfor Sub main wiring with two single core of size 6.00 SqmmFRLSHPVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradedrawn in and including non metallic rigid PVC conduit medium quality of size 20 mm dia conforming to 3537 Part-IISI marked includingall fittings such as Tee, Elbow, bend etc. drawn in and includingone single core of size 4.00 SqmmFRLSH PVC insulated unsheathedwith multistranded copper conductor cable 1100 volts gradeasin contineous earth conductor cable connected to earth dolly complete all as directed.(Colour code phase-Red, Nuetral-black and Earth as Green) complete all as specified & directed.Notes:-(a) Cost of PVC conduit , conduit accessories i.e. PVC Clamp, rawl plug, screws, PVC junction box, Tee, bend , Elbow etc. and earth wire included in sub main wiring and nothing shall be paid extra on this account. (b)Two single core 6.00Sqmm and one single core 4.00 Sqmm cable including non metallic rigid PVC conduit of size 20 mm dia shall be measured as one length. 15 Supply and fixing energy efficient LED security light fitting of 60W pressure die cast aluminium housing/body, heat resistant clear toughened glass,better optics for uniform distribution street luminaire, with driver, including electric connection with using 3 core flexible copper conductor cable 1.5Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 25mm dia, 1.2 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt.(b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95(e) THD : Max10%.(f) IP rating : IP66. (g) IK rating:Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire.(j) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI: Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 16 Supply and fixing LED tube light fitting polycarbonate housing 1 x 20Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt.(b) Input Voltage range : 140 to 270 volts.(c) Temp operating range : Minus 5°C to Plus 45°C(d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5%(f) IP rating : IP-20.(g)LED Driver of the same make as of the luminaire.(h) LED driver should be complete with all protections vizopen/short circuit protection, over voltage protection, all as per standard design of manufacturer.(j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K(l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily) 17 Supply & Fixing (Concealed flush to wall) Factory made Distribution Board(made out of CRCA sheet not less than 1.2mm thick, fitted with DINchannel ,neutral link and 200 Amp rated copperbus bar),VTPN 4 way ,415 Volt, suitable for mounting MCBs/Isolators etc., conforming to IS-13032, DB shall be semi gloosy finished with expoxy polyster based powder paint sprayed and backed at high temprature between powder paint process to ensure smooth finish and protection against corrosion atmosphere.The DB shall be double door type with hinged door andwith locking arrangement, the DBs shall be same make as MCBs / Isolators, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified .The DBshall be of IP-43 Protection classcomplete all as specified and directed. Note: MCBs /Isolators etc. shall be measured and paid seperately under appropriate item of Schedule "A" BoQ. 18 EXTERNAL WATER SUPPLY WORKS NOTE:- For items of EXTERNALWATER SUPPLY WORKSnotes given at the beginning of Sch ‘A’ Part-III ( EXTERNAL WATERSUPPLY WORKS) shall also be applicable. 19 Material and LabourConstruction of brick masonary valve pitType "B" ,chamber of internal size 600mm x 600mm x 600mm , PCC 1:4:8 type D2 using( 40mm graded stone aggregate )lean concrete infoundation , providing old size well burnt claybrick masonary wall of 230mm thick built in Cement Mortar1:4 , Rendering 15mm thick in cement mortar 1:4 finished even and fairinternally ,supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mm x 50mm x 6mm thick angle ironframe , embeded in PCC coping with PCC 1:2:4 type-B1 using 20mm graded stone aggregates, with locking arrangement and 1 No. 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25mm x 6mm flat iron and applyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide zinc chromate primer ) to all exposed surface including earth work i.e. excavation, returing filling and removal ofsoil complete all as specified and as directed andall as shown on drawings No.BTD-811 sheet 1/2 to 2/2 Note:- The rate of earth work i.e. excavation, returing filling and removal of soil is included in thisitem and nothingshall be paid extra on this account. 20 COMMON ITEM FOR EXTERNAL WATER SUPPLY WORKS AND EXTERNAL ELECTRIC SUPPLYWORKS NOTE:- For items of EXTERNAL WATER SUPPLY WORKS AND EXTERNAL ELECTRIC SUPPLYWORKSnotes given at the beginning of Sch ‘A’ Part-III & Part-IV ( EXTERNAL WATER SUPPLY WORKS AND EXTERNAL ELECTRIC SUPPLYWORKS) shall also be applicable. 21 Material and Labour for Making the holeunder road / pavement / hard standing not less than 1.00 metre depthfor laying and inserting of GI Pipe Light grade / medium gradeup to 40mmbore ,in any lengthas required at site by mechanical drill system or Auger system and making the surface good as per existing surface complete all as specified and directed. Note : The GI tube Light grade / medium grade 40mm boreshall be measured and paid as material and labour seperately under respective item of Schedule "A" Part-III EXTERNAL WATERSUPPLY WORKS and Schedule "A" Part-IVI EXTERNAL ELECTSUPPLY WORKS 22 EXTERNAL ELECTRIC SUPPLYWORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLYWORKSnotes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL ELECTRIC SUPPLYWORKS WORKS) shall also be applicable. 23 Supply, Fabricating, installation, testing, commissioning and electrically connecting LT feeder Pillar Box ,Cubical type of size 60 cm x 40 cmx 30 cm , 415 volts, Factory made, machine pressed, dust and vermin proof, out door type , made with CRCA sheet 3.15 mm thick, Feeder Pillar Box shall be internally and externally painted with expoxypowder coated paintshade as approved by GE with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish.Frontopeningwith single door with provn of rubber beading and locking system,with andincluding 200 Amp aluminium bus bar set of 4 with provn of hole on bus bar for fixing of cable mounted on 04 Nos. PVC / epoxy insulators, with and including MCCB 100 Amp, 4 Pole, 415 volts rating with breaking capacity 16 KA, adjustable setting = 80-100% -01 No. and mounted on angle ironframe and legs made with angle iron size 50mm x 50mm x 6 mmduly spray painted with tow coats of synthetic enamel paint over a coat of red oxide zinc chromateprimer , legs shall be embeded /grouted in PCC (1:2:4) Type B-1(using 20mm gradedstone aggregate) including necessary earth work complete, with andincluding all provn of opening for incoming/ outgoing cables and testing complete all as directed by Engr-in-Charge.Note:- The cost of 200 Amp aluminium bus bar set of 4 PVC / epoxy insulator and MCCB 100 Amp , 4 Pole , 415 Volts rating with breaking capacity 16 KA-01 No.is included in this item and nothing shall be paid extra on this account. 24 Material andLabour sand cushioning, with dry and cleansand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified.(Note:- Punned thickness shall be considered for payment purpose)
|