Replacement Of Irreparable Cassette And Split Air Conditioner Installed At Shilpa Sadan- 1 Supply, Installation,Testing & Commissioningof2.5 TR cassette type AC machines having Cooling Capacity of 8.79 KW, with fixed speed rotary compressor, refrigerant gas R32 / R410, BEE star rating of 2.00, ISEER 3.65, air-flow range CFM (706 - 1218 CFM), both condenser and cooling coils made of copper tube connecting chord with plug topconfirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make: Mitsubishi Electric / O-General / Hitachi / Daikin) 2 Supply, Installation,Testing & Commissioningof2 TR cassette type AC machines having Cooling Capacity of 8.79 KW, with fixed speed rotary compressor, refrigerant gas R32 / R410, BEE star rating of 2.00, ISEER 3.65, air-flow range CFM (706 - 1218 CFM), both condenser and cooling coils made of copper tube connecting chord with plug topconfirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make: Mitsubishi Electric / O-General / Hitachi / Daikin) 3 Supply, Installation,Testing & Commissioningof3.5 TR cassette type AC machines having Cooling Capacity of 12.31 KW, with fixed speed rotary compressor, refrigerant gas R32 / R410, BEE star rating of 2.00, ISEER 3.15, air-flow range CFM (742 - 1288 CFM), both condenser and cooling coils made of copper tube connecting chord with plug topconfirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make: Mitsubishi Electric / O-General / Hitachi / Daikin) 4 Supply, Installation,Testing & Commissioningof3 TR cassette type AC machines having Cooling Capacity of 10.55 KW, with fixed speed rotary compressor, refrigerant gas R32 / R410, BEE star rating of 2.00, ISEER 3.65, air-flow range CFM (706 - 1218 CFM), both condenser and cooling coils made of copper tube connecting chord with plug topconfirming to ISI 1391 (Part-I & Part-II) with all amendments. (Make: Mitsubishi Electric / O-General / Hitachi / Daikin) 5 SITC inciuding vaccumiazation and Nitrogen of testing of following nominal size of soft / hard drawn copper refrigerent piping for Cassete type AC, complete with fttings, with adjustable ring type hanger supports, jointing / brazing inchuding acccssories, insulated with XLPE class-0 tubular insulation / with Class-O closed cell elastonctric nitrilerubber tubular sleeves sections of specified thickness as given below for suction and liquid lines all accessorics as per specification etc. as required. 6 (i) 5/8(15.88 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 9mm thick insulation. 7 (ii) 3/8(9.53 mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 9mm thick insulation 8 Cutting ofexisting false ceiling grid (3.5 x 3.50 for fixing the indoor unit as required and neccy. Addition, alternation of false ceiling after fixing the unit. 9 Supply & Laying of 25 mm dia PVC drain pipe with 6mm thick nitrile rubber insulation incl. necy. Accessories. (Make: Supreme / Oriplast) 10 Supply, Installation, Testing & Commissioning of split type AC machines having capacity Cooling Capacity range (5.2-5.3 KW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), air-flow range CFM(560-600) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-1 & Part-II) with all amendments. (Make- Mitsubishi Electric / O-General / Daikin / Carrier / Voltas / Bluestar / Hitachi) 11 Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (6.6 kw - 7.0 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (780-850), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make: Daikin / O-General / Carrier / Blue Star / LG / Mitsubishi Heavy) 12 Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (3.35 kw - 3.6 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (340-400), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments. (Make: Daikin / O-General Voltas / Blue StarMitsubishi Heavy) 13 SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft / hard drawn copper refrigerant piping for Split type AC, complete with fttings, with adjustable ring type hanger supports, jointing / brazing including acccssories, insulated with XLPE class-0 tubular insulation / with Class-0 closed cell elastonctric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines all accessorics as per specification etc. as required. 14 (i) 5/8 (15.88mm) dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19mm thick insulation. 15 (ii) 1/4 (6.4 mm)dia (soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22) incl. 19mm thick insulation. 16 Supply and laying of 1.1KV grade 3 Core 2.5 Sqmm. copper armoured round cable from IDU to ODU for above mentioned AC machines. (Make: Polycab / Havells / Gloster / Finolex) 17 Supply & Laying 19 mm dia flexible drain Water piping work out of PVC incl. fitting with accessories. 18 Scaffolding Charges from ground floor to 8th floor for properly setting and clappingthe Gas pipeline & water drainage pipes, also keep them until complete the work (5-6 days) and after complete the work dismantling the sameIncluding transportation charge. During working it is mandatory to wear safety belt and other necessary safety arrangement for all working staff of concerned agency as per direction of EIC. (G + 8) Storied Building (9 Storied x 6 Vertical Run) 19 Making Iron Structure after supply 2x2 (9 ft.), 12x 1½ (10 ft), 1x1(28 ft) Iron angel and 3/4 (26 ft) flat after cutting the same fixing on outside flat wall, cutting the wall fitting the angels and stinting by sand & cement muter electric welding the angels for fitting outdoor and standing ground also making safety railing by welding iron Angel & flats and painting the structure enamel primer & paint.
|