Providing And Installation Of Pumping Machineries And Other Electromechanical Accessories For New Wtp For Augmentation Of Intake Wtp And Rising Main For Surface Water Based Piped Water Supply Scheme Mukutmanipur, Khatra, And Ranibandh Under Bankura-2 Supply, Delivery and storage at site of Horizantal Split cashing Clear water CentrifugalPumping Machinarywith base plate flexible coupllng, coupling guard, foundation bolt etc. other Accessories etc. having the following specification and as per technical Specifications given in NITN.B- H-Q curve has to be submitted during the delivery(1W+1S) 3 a) Discharge : 310M3/Hr, Total Head : 110 mtrs. 4 Supply, Delivery and Storage at site of suitable capacity Horizontal Foot Mounted solid shaft Induction Motor (IE 4 type) suitable for the pump duty mentioned above with adequate margin as per detail technical specification given in NIT.N.B-No load as well as short-circuit Test Certificate of induction motor during test run has to be submitted during the delivery. 5 Supply, Delivery and storage at site of Horizantal Split cashing Back wash CentrifugalPumping Machinarywith base plate flexible coupllng, coupling guard, foundation bolt etc. other Accessories etc. having the following specification and as per technical Specifications given in NITN.B- H-Q curve has to be submitted during the delivery(1W+1S) 6 a) Discharge-200 M3/Hr Total Head : 20 mtrs 7 Supply, Delivery and Storage at site of suitable capacity Horizontal Foot Mounted solid shaft Induction Motor (IE 4 type) suitable for the pump duty mentioned above with adequate margin as per detail technical specification given in NIT.N.B-No load as well as short-circuit Test Certificate of induction motor during test run has to be submitted during the delivery. 8 Supply & delivery at site following Valves 9 CIDF single door swing check NRV rating asper IS:5312 Part– I , and as per technical Specifications given in NIT 10 DN 150 mm (P.N.–1.0) (for Back wash individiual delivery header) 11 DN 200 mm (P.N.–1.6) (for H/L individiual delivery header) 12 CIDFnon-rising Sluice Valve generally conforming to IS 14846as per technical Specification given in NIT 13 DN – 200mm (P.N-1.0)(for Back wash Suction Line) 14 DN – 250mm (P.N-1.0)(for Clear water H/L Suction Line) 15 DN – 400mm (P.N-1.6)(for Clear water H/LCommon delivery header) 16 Supply and delivery ofthree phase actuator operated wafer type butterfly valveas per Bs-5155and as per technical Specification given in NIT 17 DN 80 mm (PN-1.0) (For Dewatering Pump delivery header) 18 DN 150 mm (PN-1.0) (For Back wash delivery header) 19 DN 200 mm (PN-1.6) (For H/L individual delivery header) 20 Supply delvery at site and storage of Ductile iron Tamper Proof Single Orifice Air Release Valve of DN 50 as per relevanl lS Standard 21 i)DN 50 for H/L Commn delivery header) 22 Supply, delivery & storage and installation at site M.S fabricated dismantling joints with rubber compression ring and adjustable follower flanged complete assembley with galvinised stud and nuts,as per technical Specifications given in NIT 23 DN: 200 mm(P.N–1.0) (for Back wash Suction line) 24 DN: 150 mm(P.N–1.0) (for Back washdelivery line ) 25 DN: 200 mm (P.N–1.0)(for Back wash Commn header ) 26 DN: 250 mm(P.N–1.0) (for H/L Suction line) 27 DN: 200 mm(P.N–1.6) (for H/L individual delivery line ) 28 DN: 400 mm(P.N–1.6) (for Commn delivery header ) 29 Supply, delivery & storage at site M,S Pipesfor individual pump suction & delivery line from pump discharge upto common delivery header, M.S flanges, bends, specials, etc. as required to make the installation ofdelivery and common delivery header of pumpingmachineries complete in all respects up to the satisfaction of E.I.C.and as per technical Specifications given in NITi) For Clear Water Pump & Back wash Pump 30 Supply delivery and storage at site of full bore Electromagnetic Flow Meter with remote indicator cum totalizer unit and cable between the meter and indicatoras per technical specification 31 i) DN: 400 (for H/L Common Header header) 32 Supply, delivery & storage ofGleeserine type pressure gauge,cast Al. dial along with DN-15 GI impulse line with valve. 33 i) (0 – 10 Kg.) 102 mm dia for individiual delivery header 34 ii) (0 – 10 Kg.) 150 mm dia for Common Header 35 Supply, delivery & storage ofGleeserine type Compound gauge, cast Al. dial along with DN-15 GI impulse line with valve. 36 i) (+1 – 1 Kg.) 102 mm dia for individiual Suction line 37 Supply, delivery and storage at site of following L.T cables 38 300 Sq. mm x 2 nos3.5 core, 1.1 KV grade, Al. Ar XLPE cable conforming to IS : 7098 (Part – I).FromPDB to MCC 39 185 Sq. mm 3 core, 1.1 KV grade, Al.ArXLPEcable conforming to IS : 7098 (Part – I).a) 2 nos H/L motor x 60mtr =120 mtr 40 25 Sq. mm 3 core, 1.1 KV grade, Al.ArXLPEcable conforming to IS : 7098 (Part – I).a) 2 nos Back Wash motor x 60mtr =120 mtr 41 1.5 sq mm , 12 core , 1.1 KVGrade XLPECopper Armoured control cable as per relevent IS.a) For H/L4 nos actuater x 30 mtr= 120 mtr 42 10 Sq. mm 4 core, 1.1 KV grade, Al. Ar XLPEcable conforming to IS : 7098 (Part – I).For PDB to Gaseous Chlorine Room 43 6 Sq. mm 3 core, 1.1 KV grade, Al. Ar XLPEcable conforming to IS : 7098 (Part – I).For MCC to Dewatering Pump 44 4 Sq. mm 2 core, 1.1 KV grade, Al. Ar XLPEcable conforming to IS : 7098 (Part – I).For MCB toOut door lighti) At P.H- 100mtrii) At Gas Plant- 100mtr 45 N.B-Purchase of all cables should be as per actual site requrement 46 Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt PDBPanelhaving required Feedersas per technical Specifications given in NIT 47 Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted415 Volt MCChaving required Feeders as per technical specification given in NIT 48 Supply delivery and storage at site of Ultrasonic type continuous level measuring unit with provision of 4 to 20 mA analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low - low level in suction sumpas per technical Specifications given in NIT 49 Supply, delivery at site and storage of vacuum operated gaseous chorination system of capacity 0-2kg/hr (1W+1S) along with ali equipmenis instrument and accessories &Making Neutralization system of abovegaseous chorination systemalong with all equipmenis instrument and accessories andas per technical Specifications given in NIT 50 Making Neutralization Pit for abovegaseous chorination systemas per technical Specifications given in NIT 51 Supply & delivery at site horizontal type centrifugal self priming non-clog dewatering pump with horizontal type 3.7KW, 415V ,50 Hz , three phase squirrel cage IE4 Induction motor including supply of channel base frame ,coupling and coupling guard complete setDischarge capacity : 10 LPS to 1.9 LPSTotal Head :20 mtr-32 mtr, 29rpm.Suction/delivery- 80mm/80mm 52 Supply and delivery at site 80mm dia G.I pipe. With fittings i.e- Elbow, Union, Nipple. G.M Ball valve. C.I Foot valve etc for making suction and delivery line for dewatering pump. 53 Design, manufacturing and supply of 5MT capaciy x 10 mtrs Span approx x 6.5 mtrs. Lift single glrder construct on Hand Operated Over Head Travelling monorail compleie with indef brand Triple Spur Gear Chaln Puley Bock and Geared Travelling Trolley including supply of Steel Gantry Girder wilh 40mm square rail suiable for the above crane for total length of 14 x 2 = 28 mtrs. The bay length shal be 14 mtrs. (approx)and suppoting disiance for the steel gantry grder shall be 4.0 mtrs. max. The Crafe shall be des gned for class-1 duty indoor operation conforming to lS:807, lS:3177 and lS;3832. The Crane and Gantry Dirder shall be supplied at site duly painted with two coats Red Lead Primer. as per technical Specifications given in NIT(Test and Guarantee Certificate have to be supplied at the time of delivery) 54 Supply deliveryof outdoor typeLED light fixture Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.M.No-BRP409 LED115 CW SLC FG PSU GR V2 of Philips make or equivalent model.i) at Pump Houseii) Meter Roomiii) Chlorine Room 55 Supply delivery & fitting fixing of Indoor typeLED light fixture Operating Voltage 140V-270 V AC 50Hz , with PDC housing & toughened glass suitable for ceiling (Surface/Suspended) mount & available in Wide beam (Rotational Symmetric) optics.EnduraLED Midbay Robust & reliable IP66 & IK08 protected LED midbay M.No-BY150P LED76S CW PSU HE SY120 FG GR(Make Philips/equivalent model)i) For Pump Houseii) For PDB Room 56 Supply delivery80mm diaM.S Black pipe Medium (Class B) as per IS:1239 PART-1 (2004). i) 1.5 mtr long each x 10 nos = 15mtr(For holding Arm at Pump House Roof) 57 Supply delivey of 1.5 mtr. long M.S Arm bracket made out of40 mm dia MS pipe with painted anticorrosive paint . 58 Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting250 x 250 x 100mm 59 PART-B ( Intallation) 60 Installation of all items mentioned as in PART A (1 to 26)including supply of all erection items,as required for installation of Submersible pumping machineris & Centrifugal pumping machineris , all valves, delivery pipe line, PDB cum MCC panel,Chlorine system, cable tray, indoor & outdoor light,laying of cable on cable tray includingsupplying all necessary items i.e- nut & bolt wather rubber gasket, with painting, jointing of cables termination cable soketing by suitable rated sockets, jointing the delivery header with H/Lrising main, suporting piller and paining anticorrosive paint etc. including cost ofgas cutting, welding etc. as required for complete the installationas per Hydraulic standard & IE rules in compliance by engaging skilled technician all complete as per Technical specificationand upto entire satisfaction of EIC. 61 Supply, delivery Fixing at siteG.I cable tray for laying of power cable and G.I Perforated cable tray for laying of control cable at Pump House having proper M.S. structural supportas per technical Specifications given in NIT 62 Earthing & lightning protection for Pump House, electrical installation as per ISS and IE rules andas per technical Specifications given in NIT(2 nos Earth pitfor each intallation) 63 Internal wiring and Lightingarrangementincluding internal illumination ofpump house building. as per technical Specifications given in NITi) at Pump Houseii) Gaseous Chlorine Room 64 Supply delivery and installation at site and storage of safety equipment like 6.5 kg Co2 squeeze grip type capacity Fire Extinguisher , sand bucket with bracket , rubber mats, shock treatment chart and first aid box, complete as per technical Specifications given in NIT 65 Cost of filling of 100kg baby empty cylnders fromauthorised liquid chlorine refilling station including charges of testing of cylenders, transpotation etc all completeas per technical Specifications given in NIT (4 nos cylinder) 66 Making Masonry Cable Trench for laying HT & L.T Cable as per site requrement & other civil works as per technical specification 67 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. 68 Earth work in excavation of foundation trenches or drain in all sorts of soil( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. 69 Filling in foundation or plinth by silver sand in layer not exceeding 150mm as directed and consolidating same by thorough saturation with water ramming complete including cost of supply of sand. 70 Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 71 Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth 72 (b) In superstructure, ground floor 73 Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement if any in ground floor as per relevant IS codes. i) Pakur variety 74 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups binders etc. including supply of rods initial straightening and removal of loose rust ( if necessary ) cutting of requisite length ,hooking and bena) For works in foundation basement and up to roof of ground floor / up to 4 meter. i) Tor steel/Mild steel. (SAIL/ TATA/ RINL) 75 Plaster ( to wall, floor , ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and racking out joints or roughening of concrete surface including throating nosing and drip course where necessary (Ground floor).[Excluding cost of chipping over concrete surface] a) With 1:6 Cement mortar ( 25mm thick ) 76 Neat cement punning about 1.5mm thick in wall. dedo, window sill floor etcNote- Cement0.152 Cum per 100sqm 77 Moveable Galvanized plain sheet Pit cover M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. 78 Galvanised plain sheet works (excluding supporting framework) fitted and fixed with 6 mm. dia J or L hook-bolts and nuts, sheet-bolts, limpet and bitumen washers and putty with 150 mm. end lap & 50 mm minimum side lap complete.(a) In roof: with 0.63 mm. sheets. 79 Supply delivery arrd storage at site of causticSoda Flskes as per IS-252-20L3 {@300 kg,/site} 80 Supply and delivery of 2(Two) nos Colored cast Plastic Chair & 1(one) nos rectangular foldable potable table as per technical specication given in NIT 81 Supply delivery of500 mm dia 230 voltsweep AC Padistal fan withcomplete with all accessory(Make Havelles/Poler/Bajaj) 82 Testing & Commissioning of the entire installatione Pumps Motors Valves, LT Panels cables earthing Gaseous Chlorination System flowmeter and HOT Crane elc as per direction and upto thesatisfaction of EIC in compliance with NIT specification 83 Trial run of pumping machinery, through PLC / Automatic panel also operation of Pumping machineris, Gaseous Chlorinator, including operation ofvalves if required and guarding of installationfor engaiging 6(Six) persion as per direction of E.I.C. (90days) 84 Add: 18% GST 85 Add: 1% Cess
|