Repairing & rejuvenation of electro-mechanical accessories for Sundraguri W/S scheme in Binpur-I block under Jhargram Mechanical Division, PHE. Dte.-- 1 Supply and delivery of following material at site:- 102 mm. dia 0-10 kg/cm² range wall mounted pressure gauge complete with brass cock & other fittings as per direction of E.I.C for tubewell outside the pump house. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 2 102 mm. dia. wall mounted depth gauge capable to measure direct reading in feet with 6mm PVC steel pipe with socket including supply of one good quality hand pump hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. Pipe approx. 90 ft. length and specials) Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 3 M.S fabricated split type suitable tube well cover as per tube well housingwith necessery clamping arrangementincluding provision of holes for column pipe ,air pipe and cable entry etc. all complete as per direction of E.I.C 4 Anti-snapping safety device for above pump by supplying suitable size. Nylone rope of required length (double) including supply of all necessary materials as required. 5 M.S suspention clamp with necessary nuts,bolts & washer etc. suitable for 50mm dia pipe ( Size 300mm x 50mm x 8mm each) 6 1.1 KV Grade 415 V, 2 core 10 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 7 50 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 8 50 mm dia ,PN-1.0 CIDF wafer typebutterfly valve.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 9 50mm dia heavy type suitable length CI/MS Black pipes (for common delivery header,backwash line for pump under sl no-1, along with necessary bends, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismenteling joint, for connecting main pipe line etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete . 10 Supply ,delivery & installation of chlorination system with all equipment and accessories as per following specification:- 1 no. dosing pump of capacity 0-100 lit/hr. max. discharge and 10 Kg/cm². pressure maxwith Motor 0.5 HP, 1 Ph, 50Hz 220 Volt, 1440 rpm TEFC cooling motor, base plate rate adjustment device etc. ii. 100 lit HDPE dosing tank for storing of chlorine solution. iii. Necessary GI pipe fittings and HDPE / PVCpipe line for dosing the solution with all accessories as per requirment. Pump Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. (Motor Make- CGL/KEC/ABB/Any approved make) 11 10KVA, single phase, oil cooled type having unbalance 115-289V input voltage and 230 V(± 1%) output voltage, auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCBat output side &input MCB isolator, Ammeter Bell etc. As per IE Rules and as per technical specification. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 12 63 Amp,10 kA, 240/415V, 50 Hz Double poleMCB conforming to IS / IEC: 60947-3, "C" characteristics with enclosure. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 13 6-32Amp,10 kA, 240/415V, 50 Hz SPN MCB conforming to IS / IEC: 60898-1, "C" characteristics. ( 6Amp-2nos,10Amp-1 nos,16Amp-1no)Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 14 10 Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, "C" characteristics.Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 15 6 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 4) conforming to IS 13032 & IS 8623 and IP42/43. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 16 63 Amp,240V, 50 Hz Double pole main switch conforming to IS / IEC: 60947-3, "C" characteristics with enclosure. Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 17 63 Amp. 2 pole on load change over switch (Make:-Approve make of P.H.E. Dte.) 18 63 Amp, 240/415 V Porcelain fuse unit (Base & Bridge) Make :- As per approved vendor list of PHED vide no. 8864/79/F/2018 dated 28.06.2024 with latest amendments. 19 Hard wooden board (450mm X 304.8 mmx 25 mm thick) 20 1/2" dia ball valve (PVC) 21 1/2" dia non return valve(G.M) 22 1/2"dia GI tee 23 1/2"dia Gl elbow 24 1/2"dia Gl short pipe (3" long) 25 1/2"piece 26 1/2" dia ms clamp 27 1/2"dia PVC tank connector 28 1/2" dia cotton breaded hose pipe 29 25mm dia ball vaive 30 25mm dia union (PVC) 31 25mm dia elbow (PVC) 32 25mm dia PVC pipe (Sch 80) conforming to ASTMD 1785 & threaded to mach with G.I pipe as perl: 1239(part-1) 33 25 mm dia tank connector 34 25 mm dia G.I. socket with ISI mark 35 100 liter capacity loft tank (white) Make-Syntex/any other approved make 36 supply and delivery of iron angle frame for installation of tank in which hypocloride solution mixed with water(frame weight 22 kg approx) 37 Dismantling the all mechaical connection of existing chlorine machine for modification work as per direction of E.I.C 38 Modification of disinfection arrangement with newly supplied materials & old servic cable spares including necessary fitting fixing materials as per direction of E.I.C. 39 Testing of the whole installation with demonstration to the agency labour engaged as pump operator & upto entire satisfaction of E.I.C 40 Installation of item:- Laying of cable on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C. 41 Installation & commissioning of above chlorinator pump set and drawing of power line by supplying necessery wire and continious earthingconnected to auto manual panel. Thisincludes the cost of making necessary brick foundation base with neat cement finish by supplying all required materials and testing the entire set asper direction of EIC. 42 Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofcable .all complete as per direction of E.I.C. 43 Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 HzSPN/DP MCB Isolator conforming to IS / IEC: 60947-3, "C" characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket & switch- 1 no, indicator- 1 no. each,with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light setsPHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency). 44 Installation, testing & commisioning of above supplied VS, MCC,valves etc (as in item no. 1 to 5, 7 to 10, 12 to 20) by making brick built foundation jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line & wash out line with the C.I specials and Tee including mending damages goods etc.all complete as per direction. This also includes the charges for laying submersible cable from tubewell to control panel by underground and saddle on wall and connection with required feeder of panel all complete. 45 Making required nos. of brick pillar 0.25 mtr. X 0.25 mtr. For supporting of valves and pipes with 12 mm thick plaster and net cement finish complete. 46 (a) Earthing with 50 mm ISI mark medium diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.i) For soft soil by ISI Medium GI pipe. 47 (b) Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe. 48 (c) Extra for treatment of soil by salt and charcoal coke for pipe electrode. 49 (d) Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr. 50 (e) Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 51 Carrying back the old unserviceable part from work site to DCC campus store including loading, unloading complete.
|