Tender For Re development Work Of Regal Talkies Area-- 1 ALL KINDS OF SOIL. 2 EXCAVATED EARTH ,FOR 2KM 3 ALL KINDS OF SOIL. 4 IN AREA OF LIGHT JUNGLE 5 EXCAVATION FOR ROADWAY IN SOIL BY MANUAL MEANS INCLUDING LOADING IN TIPPERS AND DISPOSAL WITH ALL LIFTS AND LEAD UPTO 10 6 CONSTRUCTION OF EMBANKMENT/SUB GRADE/ EARTH SHOULDERS, AS PER CLAUSE 305 & ITS SUB-CLAUSES, WHERE REQUIRED BUT WITH APP 7 CONSTRUCTION OF GRANULAR SUB-BASE BY PROVIDING COARSE GRADED MATERIAL (CBR>30), SPREADING IN UNIFORM LAYERS WITH MOTOR 8 CONSTRUCTION OF DRY LEAN CEMENT CONCRETE SUB-BASE OVER A PREPARED SUB GRADE WITH COARSE AND FINE AGGREGATE CONFORMING T 9 CONSTRUCTION OF DOWEL JOINTED, PLAIN CEMENT CONCRETE PAVEMENT IN M-30 GRADE CONCRETE OVER A PREPARED SUB BASE WITH 43 O 10 MILD STEEL DOWEL BARS CONFIRMING TO IS 432, GRADE I 11 HYSD TIE BARS OF FE 500 GRADE CONFIRMING TO IS 1786, 12 CONSTRUCTION OF CEMENT CONCRETE MOUNTABLE/ BARRIER TYPE KERB / KERB WITH CHANNEL IN M 20 GRADE LAID WITH KERB LAYING MA 13 DEMOLISHING R.C.C. WORK MANUALLY/ BY MECHANICAL MEANS INCLUDING STACKING OF STEEL BARS AND DISPOSAL OF UNSERVICEABLE MAT 14 IN CEMENT MORTAR 15 OF AREA BEYOND 3 SQ. METERS 16 DISMANTLING STEEL WORK MANUALLY/ BY MECHANICAL MEANS IN BUILT UP SECTIONS WITHOUT DISMEMBERING AND STACKING WITHIN 50 ME 17 FOR THICKNESS OF TILES UPTO 25 MM 18 DISMANTLING ALUMINIUM/ GYPSUM PARTITIONS, DOORS, WINDOWS, FIXED GLAZING AND FALSE CEILING INCLUDING DISPOSAL OF UNSERVI 19 LIME, MOORUM, BUILDING, RUBBISH,FLY ASH , FOR 2KM 20 ALL KINDS OF SOIL 21 ALL KINDS OF SOIL. 22 ALL KINDS OF SOIL. 23 ALL KINDS OF SOIL. 24 ALL KINDS OF SOIL. 25 ORDINARY ROCK 26 ORDINARY OR HARD ROCK. 27 FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE 28 MOORUM/HARD COPRA 29 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE 30 BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN 31 UPTO PLINTH LEVEL 32 ABOVE PLINTH UPTO FLOOR 2 LEVEL 33 THERMO-MECHANICALLY TREATED BARS. (FE 500 D OR MORE) 34 EXTRA FOR R.C.C./B.M.C./R.M.C. ALL WORKS ABOVE FLOOR 2 LEVEL FOR EACHFLOORS OR PART THEREOF. 35 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 36 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 37 COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS. 38 LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS. 39 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 40 STAIRS, (EXCLUDING LANDINGS) EXCEPT SPIRAL-STAIRCASES. 41 EXCAVATED EARTH ,FOR 2KM 42 CEMENT MORTAR 1:6 (1 CEMENT : 6 COARSE SAND) 43 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 44 STAIRS, (EXCLUDING LANDINGS) EXCEPT SPIRAL-STAIRCASES. 45 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 46 AAC MASONARY IN CEMENT MORTAR 1:6 (1 CEMENT : 6 SAND) 47 EXTRA FOR AAC MASONARY WORK IN SUPERSTRUCTURE ABOVE FLOOR TWO LEVEL FOREACH ADDITIONAL FLOOR OR PART. 48 1:3 (1 CEMENT: 3 FINE SAND) 49 1:6 (1 CEMENT: 6 SAND) 50 PROVIDING SAND FACED PLASTER UPTO 10METER HEIGHT ABOVE GROUND LEVEL CONCRETE OR BRICK MASONRY SURFACES IN TWO COATS, BA 51 1:6 (1 CEMENT: 6 SAND) 52 20 MM WIDE AND 15 MM DEEP GROOVE 53 PROVIDING AND FIXING CHICKEN MESH AS PER ISI SPECIFICATION AND IN THE REQUIRED WIDTH WITH 50MM LONG BOMBAY NAILS ON VERT 54 PROVIDING AND APPLYING 1.0 MM THICK WHITE CEMENT BASED WALL PUTTY OF BEST QUALITY, OVER PLASTERED SURFACE TO PREPARE TH 55 TWO OR MORE COATS ON WALLS APPLIED @ 1.25 LTR/10 SQM. OVER AND INCLUDING ONE COAT OF SPECIAL PRIMER APPLIED 56 APPLYING ONE COAT OF CEMENT PRIMER OF APPROVED BRAND AND MANUFACTURE ON WALL SURFACE : CEMENT PRIMER. 57 PROVIDING AND FIXING STAINLESS STEEL ( GRADE 304) RAILING MADE OF HOLLOW TUBES, CHANNELS, PLATES ETC. INCLUDING WELDING 58 CEMENT MORTAR 1:6 (1 CEMENT : 6 COARSE SAND) 59 CEMENT MORTAR 1:3 (1 CEMENT : 3 COARSE SAND) 60 EXTRA FOR PROVIDING AND PLACING IN POSITION 2 NOS. 8MM DIA. M.S. / HYSDBARS AT EVERY THIRD COURSE OF HALF BRICK MASONR 61 35 MM THICK INCLUDING ISI MARKED STAINLESS STEEL BUTT HINGES WITHNECESSARY SCREWS. 62 1.0 MM THICK 63 FIXED TO OPENINGS /WOODEN FRAMES WITH RAWL PLUGS SCREWS ETC. 64 POWDER COATED MINIMUM THICKNESS 50 MICRON ALUMINIUM. 65 PROVIDING AND FIXING 12 MM THICK FRAMELESS TOUGHENED GLASS DOOR SHUTTER OF APPROVED BRAND AND MANUFACTURE, INCLUDING PR 66 FILLING THE GAP IN BETWEEN ALUMINIUM FRAME & ADJACENT RCC/ BRICK/ STONE WORK BY PROVIDING WEATHER SILICON SEALANT OVER B 67 GRANITE STONE OF APPROVED SHADE. 68 EXTRA FOR PROVIDING OPENING OF REQUIRED SIZE & SHAPE FOR WASH BASINS/ KITCHEN SINK IN KITCHEN PLATFORM, VANITY COUNTERS 69 PROVIDING AND LAYING INTEGRAL CEMENT BASED TREATMENT FOR WATER PROOFING ON HORIZONTAL SURFACE AT ALL DEPTH BELOW GROUND 70 PROVIDING AND LAYING INTEGRAL CEMENT BASED TREATMENT FOR WATER PROOFING ON THE VERTICAL SURFACE BY FIXING ROUGHT KOTA SP 71 WITH AVERAGE THICKNESS OF 120MM AND MINIMUM THICKNESS AT KHURRA AS 65 MM. 72 PROVIDING AND LAYING WATER PROOFING TREATMENT IN SUNKEN PORTION OF WCS, BATHROOM ETC., BY APPLYING CEMENT SLURRY MIXED 73 PROVIDING AND FIXING PRESSED STEEL DOOR CONFIRMING TO IS: 4351 MANUFACTURED FROM COMMERCIAL MILD STEEL SHEET OF 3.15MM T 74 SINGLE REBATE 100X50MM 75 IN STRINGERS, TREADS, LANDINGS ETC. OF STAIR CASES INCLUDING USE OF CHEQUERED PLATE WHEREVER REQUIRED, ALL CO 76 IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATESAND SIMILAR WORKS. 77 HOT FINISHED WELDED TYPE TUBES. 78 FIXING GLAZED/ CERAMIC/ VITRIFIED FLOOR TILES WITH CEMENT BASED HIGH POLYMER MODIFIED QUICK-SET TILE ADHESIVE (WATER BA 79 COURSE GRANITE LIGHT BLACK/ LIGHT RED/ OFF WHITE WITH SELF DESIGN/ PATTERN/CRYSTALS OF OTHER COLOUR OF GLITTER. 80 SUPPLYING, STACKING AND SPREADING OF GOOD EARTH FOR PLANTATION AT SITE INCLUDING ROYALTY AND CARRIAGE (EARTH MEASURED I 81 SUPPLYING AND STACKING SLUDGE AT SITE INCLUDING ROYALTY AND CARRIAGE UP TO 1 KM (SLUDGE MEASURED IN STACKS WILL BE REDU 82 SUPPLYING, STACKING AND SPREADING COMPOST/MANURE FROM APPROVED SOURCE, (MANURE MEASURED IN STACKS WILL BE REDUCED BY 8% 83 MIXING & SPREADING EARTH AND MANURE IN PROPORTION AS SPECIFIED OR DIRECTED. 84 UPROOTING RANK VEGETATION AND WEEDS BY DIGGING THE AREA TO A DEPTH OF 30 CM REMOVING ALL WEEDS AND OTHER GROWTH WITH RO 85 IN ROWS 5 CM APART IN EITHER DIRECTION. 86 PROVIDING AND LAYING SELECTED TYPE OF GRASS TURF WITH EARTH 50MM TO 60MM THICKNESS ON EXISTING GROUND PREPARED WITH PRO 87 HOLES 60 CM DIA AND 60 CM DEEP. 88 HOLES 45 CM DIA, AND 45 CM DEEP. 89 HOLES 30 CM DIA, AND 30 CM DEEP. 90 SHRUBS :- 91 CREEPER PLANTS (HEIGHT:30CM TO 45 CM) 92 ROSE BUDDED OF H.T VARIETY AND MINIATURE ROSES. HEIGHT: 30CM &ABOVE 93 AREA OF SLAB OVER 0.50 SQM. 94 COURSE GRANITE LIGHT BLACK/ LIGHT RED/ OFF WHITE WITH SELF DESIGN/ PATTERN/CRYSTALS OF OTHER COLOUR OF GLITTER. 95 STAINLESS STEEL CRAMPS. 96 FASTENER WITH THREADED DIA 6 MM. 97 MIRROR POLISHING ON MARBLE WORK/GRANITE WORK/STONE WORK WHERE EVER REQUIRED TO GIVE HIGH GLOSS FINISH COMPLETE. 98 PROVIDING AND LAYING VITRIFIED FLOOR TILES MULTI/DOBULE CHARGED (MINIMUM TOP LAYER THICKNESS 2.0MM) NENO POLISHED SELF 99 RED SAND STONE. 100 PROVIDING AND FIXING STRUCTURAL STEEL FRAME (FOR DRY CLADDING WITH 30 MM THICK GANG SAW CUT WITH MACHINE CUT EDGES SAND 101 STAINLESS STEEL (GRADE 304) WIRE GAUZE OF 0.5 MM DIA WIRE AND 1.4MM APERTURE ON BOTH SIDES. 102 KOTA STONE 25MM THICK FLOORING OVER 20 MM (AVERAGE) THICK BASE LAID OVER AND JOINTED WITH GREY CEMENT SLURRY MIXED WITH 103 KOTA STONE SLABS 25MM THICK IN RISERS OF STEPS, SKIRTING,DADO AND PILLARS LAID ON 12MM (AVERAGE) THICK CEMENT MORTAR 1: 104 ORISSA PATTERN W.C. PAN OF SIZE 580X440 MM 105 ONE URINAL BASIN WITH 5 LITRE WHITE P.V.C. AUTOMATIC FLUSHING CISTERN. 106 WHITE VITREOUS CHINA WASH BASIN SIZE 630X450 MM WITH A SINGLE 15MM C.P. BRASS PILLAR TAP. 107 510X1040 MM BOWL DEPTH 250MM. 108 610X510 MM BOWL DEPTH 200 MM. 109 PROVIDING AND FIXING G.I. INLET CONNECTION FOR FLUSH PIPE CONNECTINGWITH W.C. PAN. 110 40MM DIA 111 40MM DIA 112 RECTANGULAR SHAPE 453X357MM 113 OVAL SHAPE 450X350MM (OUTER DIMENSIONS) 114 RECTANGULAR SHAPE 1500X450 MM 115 WASTE COUPLING 31MM OF 79MM LENGTH AND 62MM BREADTH WEIGHINGNOT LESS THAN 45GMS. 116 BOTTLE TRAP 38MM SINGLE PIECE MOULDED WITH HEIGHT OF 270MM, EFFECTIVE LENGTH OF TAIL PIPE 260MM FROM THE 117 PROVIDING AND FIXING PTMT LIQUID SOAP CONTAINER 109MM WIDE, 125MM HIGH AND 112MM DISTANCE FROM WALL OF STANDARD SHAPE W 118 PROVIDING AND FIXING PTMT 15 MM URINAL SPREADER SIZE 95X69X100 MM WITH 1/2 BSP THREAD AND SHAPES. WEIGHING NOT LESS T 119 15 MM NOMINAL BORE 0.40KG 120 PROVIDING AND FIXING C.P. BRASS STOP COCK (CONCEALED) OF STANDARD DESIGN AND OF APPROVED MAKE CONFORMING TO IS:8931. - 1 121 PROVIDING AND FIXING C.P. BRASS GRATING OF APPROVED QUALITY AND MAKECONFORMING TO IS: SPECIFICATION. - 100 MM DIA. 122 C.P. BRASS 123 150 MM DIAMETER 124 PROVIDING AND FIXING C.P. BRASS LONG BODY BIB COCK OF APPROVED QUALITY CONFORMING TO IS STANDARDS AND WEIGHING NOT LESS 125 ANTI GERM FLUORO-POLYMER COATED (NANO COATING) WALL HUNG WATER CLOSET SIZE 126 PROVIDING AND FIXING IN POSITION BEST INDIAN (BONUT SIZE 24MM, CERAMIC DISC SIZE 19MM AND MIN.BODY THICKNESS 2MM, NICK 127 PROVIDING AND FIXING IN POSITION BEST INDIAN HEALTH FAUCET WITH 8MM DIA 1 METER LONG FLEXIBLE TUBE AND WALL BRACKET WITH 128 PROVIDING AND FIXING COUPLER FOR PVC PIPES & FITTINGS WASTE/RAIN WATER/DRAINAGE DISPOSAL OF SUPERIOR 129 PROVIDING AND FIXING PVC PIPES FITTINGS WASTE/RAIN WATER/DRAINAGE DISPOSAL OF SUPERIOR INDIAN MAKE ( 130 PROVIDING AND FIXING 90 DEGREE BEND PVC PIPES & FITTINGS WASTE/RAIN WATER/DRAINAGE DISPOSAL OF SUPERIOR INDIAN MAKE (AS 131 PROVIDING AND FIXING 45 DEGREE BEND PVC PIPES & FITTINGS WASTE/RAIN WATER/DRAINAGE DISPOSAL OF SUPERIOR INDIAN MAKE (AS 132 20 MM NOMINAL OUTER DIA .PIPES. 133 25 MM NOMINAL OUTER DIA .PIPES. 134 32 MM NOMINAL OUTER DIA .PIPES. 135 40 MM NOMINAL OUTER DIA .PIPES. 136 50 MM NOMINAL OUTER DIA .PIPES. 137 15 MM NOMINAL OUTER DIA .PIPES. 138 20 MM NOMINAL OUTER DIA .PIPES. 139 25 MM NOMINAL OUTER DIA .PIPES. 140 32 MM NOMINAL OUTER DIA .PIPES. 141 75 MM NOMINAL INNER DIA .PIPES. 142 100MM NOMINAL INNER DIA .PIPES. 143 15 MM NOMINAL BORE 144 20 MM NOMINAL BORE 145 25 MM NOMINAL BORE 146 32 MM NOMINAL BORE. 147 40 MM NOMINAL BORE 148 50 MM NOMINAL BORE 149 65 MM NOMINAL BORE 150 80 MM NOMINAL BORE 151 HORIZONTAL 152 VERTICAL 153 VERTICAL 154 VERTICAL 155 15 MM NOMINAL BORE 156 15 MM NOMINAL BORE 157 CUTTING HOLES UP TO 15X15 CM IN R.C.C. FLOORS AND ROOFS FOR PASSING DRAIN PIPE ETC. AND REPAIRING THE HOLE AFTER INSERTI 158 50MM DIA 159 65 MM DIA 160 75 MM DIAMETER (MINIMUM WALL THICKNESS 3.2MM) 161 110 MM DIAMETER (MINIMUM WALL THICKNESS 3.2MM) 162 75 MM 163 110 MM 164 75 MM 165 110 MM 166 75X75X75 MM 167 110X110X110 MM 168 75X75X75 MM 169 110X110X110 MM 170 75 MM BEND 171 110 MM BEND 172 75 MM SHOE 173 100 MM SHOE 174 75 MM 175 110 MM 176 75 MM 177 110 MM 178 75 MM 179 110 MM 180 110X75X40 181 110X75 MM 182 110X110 MM 183 75MM DIA 184 110MM DIA 185 100 MM INLET AND 75 MM OUTLET 186 100 X 100 MM SIZE P TYPE 187 150 X 100 MM SIZE P TYPE. 188 PROVIDING, LAYING & JOINTING OF DWC (DOUBLE WALL 189 200MM/238MM PROVIDING AND LAYING& JOINTING OF DWC (DOUBLE WALL CORRUGATED) PE PIPES OF RENOWNED DULY TESTED INCLUSIVE OF 190 250MM / 295MM (PROVIDING, LAYING & JOINTING OF DWC (DOUBLE WALL CORRUGATED) PE PIPES OF RENOWNED DULY TESTED INCLUSIVE O 191 150 MM 192 200 MM 193 250 MM 194 150 MM 195 200 MM 196 250 MM 197 150 MM 198 200 MM 199 250 MM 200 ALL KINDS OF ORDINARY SOIL 201 MAN HOLE WITH ABOVE SPECIFICATIONS HAVING INSIDE SIZE 90X80 CM AND 60 CM DEEP INCLUDING C.I. COVER WITH FRAME (L 202 MAN HOLE WITH ABOVE SPECIFICATIONS HAVING INSIDE SIZE 120X90 CM AND 90 CM DEEP INCLUDING C.I. COVER WITH FRAME (MEDIUM D 203 90X80CM SIZE MANHOLE 204 120X90CM SIZE MANHOLE OVER ITEM. 205 WITH 20MM SQUARE BAR/ CASTING ONE FOOT REST 206 WITH 20MM ROUND BAR FOOT REST 207 FOR PIPES 250 TO 300 MM DIAMETER 208 150 MM DIA 209 110 MM DIAMETER OD 210 MAN HOLE WITH ABOVE SPECIFICATIONS HAVING INSIDE SIZE 90X80 CM AND 60 CM DEEP INCLUDING C.I. COVER WITH FRAME (L 211 MAN HOLE WITH ABOVE SPECIFICATIONS HAVING INSIDE SIZE 450X450MM AND 900MM DEEP INCLUDING SFRC SQUARE 212 MAN HOLE WITH ABOVE SPECIFICATIONS HAVING INSIDE SIZE 600X450MM AND 900MM DEEP INCLUDING SFRC RECTAN 213 90X80CM SIZE MANHOLE 214 45X45CM SIZE MANHOLE 215 60X45CM SIZE MANHOLE 216 CHAMBER 45X45X77.5CM WITH VERTICAL GRATING 450X100 MM SIZE 217 CHAMBER 50X45X60CM WITH HORIZONTAL GRATING 500X450MM 218 CHAMBER 110 X 50 X 77.5CM WITH 500X450 MM HORIZONTAL AND450X100 MM VERTICAL GRATINGS BOTH. 219 PROVIDING, LAYING & JOINTING OF DWC (DOUBLE WALL 220 200MM/238MM PROVIDING AND LAYING& JOINTING OF DWC (DOUBLE WALL CORRUGATED) PE PIPES OF RENOWNED DULY TESTED INCLUSIVE OF 221 250MM / 295MM (PROVIDING, LAYING & JOINTING OF DWC (DOUBLE WALL CORRUGATED) PE PIPES OF RENOWNED DULY TESTED INCLUSIVE O 222 11.2 PROVIDING, LAYING & JOINTING OF DWC (DOUBLE WALL 223 150 MM 224 200 MM 225 250 MM 226 300 MM 227 150 MM 228 200 MM 229 250 MM 230 300 MM 231 150 MM 232 200 MM 233 250 MM 234 300 MM 235 ALL KINDS OF ORDINARY SOIL 236 STRUCTURAL STEEL WORK IN SINGLE SECTION FIXED WITH OR WITHOUT CONNECTING PLATE INCLUDING CUTTING, HOISTING, FIXING IN P 237 SUBMERSIBLE PUMP 150 MM DIA (WITH BRONZE /STAINLESS STEEL (CF8M) IMPELLER) UP TO 8 STAGES 5HP 238 PROVIDING ORANGE COLOUR SAFETY FOOT REST OF MINIMUM 6 MM THICK PLASTIC ENCAPSULATED AS PER IS : 10910 ON 12MM DIA STEEL 239 2.5 SQ.MM MULTI STRAND 240 4.0 SQ.MM MULTI STRAND 241 6.0 SQ.MM MULTI STRAND 242 PROVIDING ORANGE COLOUR SAFETY FOOT REST OF MINIMUM 6 MM THICK PLASTIC ENCAPSULATED AS PER IS : 10910 ON 12MM DIA STEEL 243 PROVIDING AND FIXING C.I. DOUBLE ACTING AIR VALVE OF APPROVED QUALITY WITH BOLTS, 244 SUPPLYING &INSTALLATION OF PRESSURE GAUGES WITH 15 MM DIA BRASS CHECK NUT & CAPABLE OF SHOWING PRESSURE READING FROM 0. 245 3 TO 12.5 HP 246 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 230V AC OPERATED WATER LEVEL CONTROL RELAY SHOULD EE ABLE TO CONNECT 247 2.5 SQ. MM. CABLE 248 SUPPLYING & ERECTING FLOAT SENSOR SWITCH FOR WATER LEVEL CONTROLLER WORKING ON 250V & RATED CURRENT 8A, WITH 2 MTR. WIRE 249 3.0 HP HEAD METRE 6-15, DISCHARGE LPM 1200-1000 250 5.0 HP HEAD METRE 15-30, DISCHARGE LPM 825-250 251 200 MM NOMINAL SIZE DIA. 252 150 MM NOMINAL SIZE DIA. 253 200 MM NOMINAL DIA(MINIMUM WALL THICKNESS 10MM) 254 150 MM DIA 255 COURSE SAND (1.5 MM TO 2.00 MM) 256 GRAVEL/PEBBLES (5 TO 25 MM) 257 BRICK BATS 258 GRAVEL PACKING IN TUBEWELL CONSTRUCTION IN ACCORDANCE WITH IS: 4097, INCLUDING 259 DEVELOPMENT OF TUBE WELL IN ACCORDANCE WITH IS : 2800 (PARTI) AND IS: 11189, TO ESTABLISH MAXIMUM RATE OF USABLE WATER Y 260 150 MM DIA 261 150 MM DIA 262 150 MM DIA 263 200 MM NOMINAL SIZE DIA. 264 150 NOMINAL SIZE DIA. 265 200 MM NOMINAL DIA(MINIMUM WALL THICKNESS 10MM). 266 5 HP, UPTO 5 STAGES 267 2.5 SQ.MM MULTI STRAND 268 SUPPLYING AND LAYING OF APPROVED MAKE NYLON ROPE 12 MM THICK COMPLETE WITH BINDING FOR SUPPORT OF PUMP AND MOTOR. 269 PACKAGE MBBR STP TECHNOLOGY PRIMARY TREATMENT 30KLD 270 SS SKID MOUTED RO SYSTEM AS PER IS: 10500 (LATEST) INCLUDING IRON REMOVING FILTER, CHLORIDE & FLUORIDE REMOVAL PUMP, RAW 271 SUPPLYING, ERECTING, TESTING AND COMMISSIONING SELF CONTAINED WATER COOLER 230/250 VOLTS 50 CYCLES NOMINALCOOLING CAPA 272 150MM DIA 273 100 MM DIA 274 200 MM DIA 275 150MM DIA 276 100 MM DIA 277 80 MM DIA 278 65 MM DIA 279 50 MM DIA 280 40MM DIA 281 32MM DIA 282 25MM DIA 283 63 MM 284 200 MM DIA 285 150 MM DIA 286 100 MM DIA 287 80 MM DIA 288 50 MM DIA 289 50MM DIA 290 100 MM DIA 291 80 MM DIA 292 65 MM DIA 293 50 MM DIA 294 PROVIDING AND FIXING ORIFICE PLATE MADE OF 6MM THICK STAINLESS STEEL WITH ORIFICE OF REQUIRED SIZE IN BETWEEN FLANGED AN 295 P150 MM DIA 296 100 MM DIA 297 50 MM DIA 298 25MM DIA 299 63 MM 300 PROVIDING AND FIXING FIRST -AID HOSEREEL WITH MS CONSTRUCTION SPRAY PAINTED IN POST OFFICE RED, CONFIRMING TO IS 884 WIT 301 PROVIDING AND FIXING HOSE CABINET OF SIZE 900X600X500MM MADE OF 2 MM THICK MS SHEET WITH 4 MM THICK 302 PROVIDING AND FIXING HOSE CABINET OF SIZE 700X600X300MM MADE OF 16 GAUGE THICK MS SHEET WITH 4 MM THICK FLOAT GLASS DOOR 303 PROVIDING AND FIXING 63MM GUN METAL BRANCH PIPE WITH 20MM (NOMINAL INTERNAL DIAMETER)SIZE GUN METAL NOZZLE CONFORMING TO 304 PROVIDING AND FIXING 4WAY FIRE BRIGADE CONNECTION (FBC)OF CAST IRON BODY WITH 4 NOS. GUN METAL MALE INSTANTANEOUS INLET 305 PROVIDING AND FIXING 2 WAY FIRE BRIGADE CONNECTION (FBC) OF CI BODY WITH2 NOS. GUN METAL MALE INSTANTANEOUS INLET COUPLI 306 PROVIDING AND FIXING AIR VESSEL MADE OF 250MM DIA, 8MM THICK MS SHEET, 1200MM IN HEIGHT WITH AIR REL 307 PROVIDING, FIXING TESTING AND COMMISSIONING OF 15MM SIZEQUARTZOID BULB TYPE SPRINKLERS, SET TO OPERATE AT 68/79 DEGREE C 308 PROVIDING, FIXING, TESTING AND COMMISSIONING OF INSTALLATION CONTROL VALVE OF CAST IRON BODY AND BRA 309 PROVIDING AND INSTALLATION OF ADJUSTABLE ROSETTE PLATE FOR SPRINKLER AS PER DIRECTION OF ENGINEER-IN CHARGE. 310 PROVIDING AND FIXING ELECTRICALLY OPERATED FLOW INDICATING SWITCHES IN SPRINKLER BRANCH LINE ON EACH FLOOR WITH NECESSAR 311 PROVIDING AND FIXING PRESSURE SWITCH IN THE MS PIPE LINE INCLUDING CONNECTION ETC. AS REQUIRED. CAPACITY 4.5 KG. 312 PROVIDING AND FIXING FLOW SWITCHES IN 100/150 MM DIA MS PIPE. CAPACITY 5.0 KG. 313 PROVIDING AND FIXING ANGLE IRON (40 X 40 X 5MM) DOOR FRAME AND M.S. SHEET (2MM THICK) CUM GLASS SHUT 314 CAPACITY 3.0 KG 315 CAPACITY 4.5 KG 316 PROVIDING AND FIXING PRESSURE TRANSDUCER (DIAL TYPE PRESSURE GAUGE WITH ISOLATION COCK) IN MS PIPE LINE (DIAL DIAMETRE 1 317 CAPACITY 4.0 KG 318 CAPACITY 6.0 KG 319 SUPPLYING, INSTALLATION, TESTING & COMMISSIONING OF APPROVED MAKE HORIZONTALLY 320 SUPPLYING, INSTALLATION, TESTING & COMMISSIONING OF APPROVED MAKE JOCKEY PUMP HORIZONTALLY MOUNTED COUPLED MOTOR (EFF-2) 321 SUPPLYING &INSTALLATION OF APPROVED MAKE DIESEL ENGINE DRIVEN FIREFIGHTING PUMP WATER COOLED 65 BHP 2150 RPM ENGINE, FUE 322 FIRE PUMPS ELECTRICAL PANEL :39.21.1 SUPPLYING, INSTALLATION, TESTING & COMMISSIONING OF CUBICAL TYPE FLOOR MOUNTED ELEC 323 SUPPLYING &INSTALLATION OF APPROVED MAKE PRESSURE SWITCH WITH 15 MM DIA BRASS CHECK NUT FOR AUTOMATIC OPERATION ON REQUI 324 SUPPLYING &INSTALLATION OF PRESSURE GAUGES WITH 15 MM DIA BRASS CHECK NUT & CAPABLE OF SHOWING PRESSURE READING FROM 0. 325 SUPPLY INSTALLATION, TESTING AND COMMISSIONING OF APPROVED MAKE REQUIRED FIRE PANEL FOR MANUAL OPERATED FIRE HOOTERS ETC 326 10 SQ. MM 327 35 SQ. MM 328 ARMOURED 4 CORE 0 70 SQ. MM 329 GLAND SIZE 22MM SUITABLE FOR CABLE 2/3, 3½, 2/4 X 10 SQ. MM OR 2X 16 SQ. MM 330 GLAND SIZE 32 MM FOR 2/3, 3½, 4 X 25 SQ. MM OR 2/3, 3½ X 35 SQ. MM OR 2/3/3½ X 50 SQ. MM. 331 GLAND SIZE 38 MM 3½ X 70 SQ. MM, 3X95SQ. MM 332 LUGS:-6MM TO 16 SQ.MM 333 LUGS:-35 SQ.MM 334 LUGS:-50 SQ.MM 335 LAYING OF ONE NUMBER ADDITIONAL PVC INSULATED AND PVC SHEATHED POWER CABLE OF 1.1KV GRADE OF SIZE EXCEEDING 120 SQ MM B 336 60 HP 337 80MM DIA 338 150 MM DIA 339 200 MM DIA 340 250 MM DIA (WALL THICKNESS 6.3 MM) 341 300 MM DIA (WALL THICKNESS 7.1 MM) 342 250 MM DIA (WALL THICKNESS 6.3 MM) 343 1620 LPM AT 56 M HEAD 344 80 MM 345 PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF WATER CURTAIN NOZZLE 15MM DIA NICKEL CHROME PLATED BRASS, BSPT, K-FA 346 PROVIDING, INSTALLATION, TESTING & COMMISSIONING OF ELECTRIC RELEASE TRIM ASSEMBLY FOR DELUGE WALL WITH TWO WAY SOLELNOI 347 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF JET FAN AS PER EXHAUST CFM SPECIFIED & CE CERTIFIED TO CLASS F300 AND 348 FOR NORMAL MODE-17000 CFM-5MM SP / FOR FIRE MODE-34000 CFM -20 MM 349 FOR NORMAL MODE-17000 CFM-5MM SP / FOR FIRE MODE-34000 CFM -20 MM 350 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ELECTROCHEMICAL CO SENSOR MEASUREMENT RANGE 0-300PPM REQUIRED,COVERAG 351 20000CFM /15MM SP 352 24G 353 24G 354 GRILLS AND DIFFUSERSSUPPLYING & FIXING OF POWDER COATED EXTRUDED ALUMINUM AIR GRILLS WITHOUT 355 CIRCUIT WIRING 2X2.5 SQ.MM. 356 CIRCUIT WIRING 4X2.5 SQ.MM. 357 CIRCUIT WIRING 6X2.5 SQ.MM. 358 CIRCUIT WIRING 8X2.5 SQ.MM. 359 LIGHT POINT/FAN POINTS. SHORT POINT 360 LIGHT POINT/FAN POINTS.MEDIUM POINT 361 LIGHT POINT/FAN POINTS.LONG POINT 362 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD. SHORT POINT 363 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD. MEDIUM POINT 364 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD.LONG POINT 365 POINT WIRING INCLUDING METALLIC SWITCH BOX, SHEET, SWITCHES, SOCKETS FOR 3 PIN 6 AMP. SOCKET OUTLET POINT WITH 1.5 SQ. 366 LIGHT POINT/FAN POINTS.SHORT POINT 367 LIGHT POINT/FAN POINTS.MEDIUM POINT 368 LIGHT POINT/FAN POINTS.LONG POINT 369 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD.SHORT POINT 370 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD.MEDIUM POINT 371 3 PIN 6 AMP SOCKET OUTLET ON SEPARATE BOARD.LONG POINT 372 CALL BELL / BUZZER POINTS LONG POINT 373 TWIN CONTROL LIGHT POINTS MEDIUM POINT 374 TWIN CONTROL LIGHT POINTS LONG POINT 375 POINT WIRING INCLUDING METALLIC SWITCH BOX, SHEET, SWITCHE, SOCKET FOR 3 PIN 6 AMP. SOCKET OUTLET POINT WITH 1.5 SQ. MM 376 SHORT POINT ON SEPARATE BOARD 377 MEDIUM POINT.ON SEPARATE BOARD 378 LONG POINT.ON SEPARATE BOARD 379 ON SEPARATE BOARD EXTRA LONG -I 380 ON SEPARATE BOARD EXTRA LONG -II 381 ON SEPARATE BOARD EXTRA LONG -III 382 SAME BOARD SOCKET 16 AMP 383 SHORT POINT ON SEPARATE BOARD 384 MEDIUM POINT.ON SEPARATE BOARD 385 LONG POINT.ON SEPARATE BOARD 386 ON SEPARATE BOARD EXTRA LONG -I 387 ON SEPARATE BOARD EXTRA LONG -II 388 ON SEPARATE BOARD EXTRA LONG -III 389 SAME BOARD SOCKET 16 AMP 390 1 OR 2 MODULE 391 4 MODULE 392 6 MODULE 393 8 MODULE 394 12 MODULE 395 1 X 1.5 SQ MM 396 2 X 1.5 SQ MM 397 3 X 1.5 SQ MM 398 1 X 2.5 SQ MM 399 3 X 4.00 SQ MM 400 6.0 SQ MM CABLE IN 25 MM CONDUIT 401 6.0 SQ MM CABLE IN 25 MM CONDUIT 402 10.0 SQ MM CABLE IN 25 MM CONDUIT 403 16.0 SQ MM CABLE IN 32 MM CONDUIT 404 CURRENT RATING -25 TO100 AMPS & 70% -100% ADJUSTABLE 405 CURRENT RATING -125 AMPS & 70% -100% ADJUSTABLE 406 CURRENT RATING -200 AMPS & 70% -100% ADJUSTABLE 407 CURRENT RATING -250 AMPS & ADJUSTABLE: 70% -100% THERMAL & 5-10 TIMES MAGNETIC SETTING 408 CURRENT RATING -500/630 AMPS & ADJUSTABLE: 70% -100% THERMAL & 4-10 TIMES MAGNETIC SETTING 409 0.5 AMP TO 5 AMP RATING 410 6 AMP TO 32 AMP RATING 411 6 AMP TO 32 AMP RATING DOUBLE POLE (DP) 412 FOR 40 AMPS. RATING ONLY. DOUBLE POLE (DP) 413 6 AMP TO 32 AMP RATING FOR TRIPLE POLE (TP) 414 FOR 40 AMPS. RATING ONLY. FOR TRIPLE POLE (TP) 415 50 AMP TO 63 AMP RATING FOR TRIPLE POLE (TP) 416 6 AMP TO 32 AMP RATING FOR TRIPLE POLE & NEUTRAL(TPN) 417 FOR 40 AMPS. RATING ONLY. FOR TRIPLE POLE & NEUTRAL(TPN) 418 50 AMP TO 63 AMP RATING FOR TRIPLE POLE & NEUTRAL(TPN) 419 6 AMP TO 32 AMP RATING FOUR POLE(FP) 420 FOR 40 AMPS. RATING ONLY. FOUR POLE(FP) 421 50 AMP TO 63 AMP RATING FOUR POLE(FP) 422 6 WAY DOUBLE DOOR 423 8 WAY DOUBLE DOOR 424 12 WAY DOUBLE DOOR 425 4 WAY (4+12) 426 6 WAY (4+18) 427 4 WAY WITH MCCB 428 8 WAY WITH MCCB 429 FIXING OF MCB / ISOLATOR SP/DP IN SHEET STEEL ENCLOSURE AS REQUIRED AS PER ACCEPTED PRACTICE, INCLUDING MOUNTING ON BUS 430 FIXING OF MCB /MCCB ISOLATOR TP /TPN/FP IN SHEET STEEL ENCLOSUREAS REQUIRED AS PER ACCEPTED PRACTICE, INCLUDING MOUNTI 431 FOR S.NO :- 8.5(1) TO 8.5(5), 8.6(1) TO 8.6 (5) & 8.7(1) 432 FOR S.NO :-8.5(6) & 8.5(7), 8.6(6) TO 8.6(7), 8.7(2) TO 8.7(3) & 8.8(1) TO 8.8(3) 433 SMALL SIZE 434 LARGE SIZE 435 SUPPLYING, FIXING,TESTING & COMMISSIONING WALL / FLOOR MOUNTED LT PANEL PRIMER COATED WITH TWO COAT OF ENAMEL PAINT & P 436 DIGITAL AMPERE METER WITH CTS WITH SELECTOR SWITCH 437 DIGITAL VOLT METER WITH SELECTOR SWITCH & HRC FUSE 438 ALUMINIUM BUS BAR STRIPS WITH PVC SLEEVES 439 LED LAMPS 440 5 WATT 441 8 WATT 442 11 WATT 443 15 WATT 444 (I) 1 PAIR 445 (II) 2 PAIR 446 (III) 4 PAIR 447 SUPPLING AND DRAWING CO-AXIAL T.V. CABLE RG-6 GRADE , 0.7 MM SOLID COPPER CONDUCTOR PE INSULATED , SHIELDED WITH FINE T 448 450 WATT 449 CEILING FAN (ENERGY SAVER 50 W)-1200 MM SWEEP 450 CEILING FAN (ENERGY SAVER 60 W)-1400 MM SWEEP 451 300 SWEEP 452 400 SWEEP 453 300MM SWEEP 454 300MM SWEEP 900 RPM 455 SUPPLYING AND FIXING DOWN ROD OF MS PIPE FOR CEILING FAN INCLUDING THREADING,PAINTING, MAKING HOLES ETC. AS REQUIRED C 456 EARTHING WITH G.I. EARTH PLATE 600MM X 600MM X 6MM THICK INCLUDING ACCESSORIES AND PROVIDING MASONARY ENCLOSER IN CEMEN 457 EARTHING WITH COPPER EARTH PLATE 600MM X 600MM X 3MM THICK INCLUDING ACCESSORIES AND PROVIDING MASONARY ENCLOSER IN CEM 458 ADD EXTRA FOR USING SALT AND CHARCOAL / COKE FOR G.I. PLATE OR COPPER PLATE EARTH ELECTRODE AS REQUIRED INCLUDING EXCAV 459 PROVIDING & FIXING 25MM X 5MM COPPER STRIP IN 40MM DIA G.I.PIPEFROM EARTH ELECTRODE AS REQUIRED. 460 PROVIDING & FIXING 25MM X 5MM G.I.STRIP IN40MM DIA G.I. PIPE(BCLASS) FROM EARTH ELECTRODE AS REQUIRED. 461 PROVIDING AND LAYING EARTH CONNECTIONS FROM EARTH ELECTRODE WITH4.00 MM DIA COPPER WIRE IN 15MM DIA G.I. PIPE(B CLASS) 462 PROVIDING & FIXING 25MM X 5MM COPPER STRIP ON SURFACE ORRECESSED FOR CONNECTION ETC. AS REQUIRED. 463 PROVIDING AND FIXING 25MM X 4MM G.I. STRIP ON SURFACE OR INRECESSED/CONCEALED FOR CONNECTION ETC. AS REQUIRED. 464 PROVIDING AND FIXING 4.00MM G.I. WIRE ON SURFACE OR INRECESSED/CONCEALED FOR LOOP EARTHING AS REQUIRED. 465 PROVIDING AND FIXING 4.00MM COPPER WIRE ON SURFACE OR INRECESSED/CONCEALED FOR LOOP EARTHING AS REQUIRED. 466 SUPPLYING AND DRAWING 4.00 SQ.MM.ALUMINIUM CONDUCTOR WIRE FOR LOOP EARTHING IN THE EXISTING SURFACE/ RECESSED/CONCEALED 467 PROVIDING AND LAYING COPPER TAPE 32MM X 6MM THICK FOR EARTHELECTRODE DIRECTLY IN GROUND AS REQUIRED 468 6 SQ MM. 469 10 SQ MM. 470 16 SQ MM 471 FOR WALL THICKNESS UP TO 9 472 6 SQ.MM.(XLPE) ARMOURED 3 CORE 473 10 SQ.MM.(XLPE) ARMOURED 3 CORE 474 50 SQ.MM(XLPE) ARMOURED 3½ CORE 475 70 SQ.MM(XLPE) ARMOURED 3½ CORE 476 95 SQ.MM.(XLPE) ARMOURED 3½ CORE 477 120 SQ.MM.(XLPE) ARMOURED 3½ CORE 478 300 SQ.MM.(XLPE) ARMOURED 3½ CORE 479 6 SQ.MM.(XLPE) ARMOURED 4 CORE 480 10 SQ.MM.(XLPE) ARMOURED 4 CORE 481 16 SQ.MM.(XLPE) ARMOURED 4 CORE 482 25 SQ.MM(XLPE) ARMOURED 4 CORE 483 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3,3½ & 4 X UPTO 6SQ.MM 484 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3, 3½, 4 X 10 SQ.MMOR 2X 16 SQ.MM 485 GLAND SIZE 28MM SUITABLE FOR CABLE 3,4 X 16 SQ.MM 486 GLAND SIZE 32MM SUITABLE FOR CABLE 2,3, 3½, 4 X 25 SQ.MMOR 2,3, 3½ X 35 SQ.MM OR 2,3 X 50 SQ.MM. 487 GLAND SIZE 70MM SUITABLE FOR CABLE 3 X 240 SQ.MM OR3½ X 300 SQ.MM 488 FOR CONDUCTOR SIZE- 2.5 TO 6.00 SQ.MM 489 LUGS:-6MM TO 16 SQ.MM 490 LUGS:-25 SQ.MM 491 LUGS:-50 SQ.MM 492 LUGS:-70 SQ.MM 493 LUGS:- 95 SQ.MM. 494 LUGS:- 120 SQ.MM. 495 LUGS:- 300 SQ.MM. 496 COPPER LUGS PIN TYPE UPTO 16 SQ.MM CONDUCTOR SIZE 497 LAYING OF ONE NUMBER PVC INSULATED AND PVC SHEATHED POWER CABLE OF 1:1 KV GRADE OF SIZE NOT EXCEEDING 25 SQ.MM IN THE EX 498 LAYING OF ONE NUMBER PILC/PVC INSULATED AND PVC SHEATHED POWER CABLE OF GRADE EXCEEDING 1.1KV BUT NOT EXCEEDING 11KV OF 499 LAYING AND FIXING OF ONE NUMBER PVC INSULATED AND PVC SHEATHED ALUMINIUM CONDUCTOR CABLE OF 1.1KV GRADE OF SIZE NOT EXCE 500 SUPPLYING ROUTE MARKER WITH 10CM X 10CM G.I. PLATE 5MM. THICK WITH INSPECTION THEREON BOLTED/WELDED TO 35MM X 35MMX 6MM 501 100.00MM FOR B CLASS G.I.PIPE ISI MARKED (IS-1161-68) 502 150.00MM FOR B CLASS G.I.PIPE ISI MARKED (IS-1161-68) 503 75.00MM O.D 504 110.00MM O.D 505 1 X 18/20/22W, INTEGRAL 506 7 W/8 W, 100/150MM 507 15 W , 180/200MM 508 8 W , 100/150MM 509 15 W, 180/200MM 510 4 ZONE 4 ZONE FIRE PANEL 511 SMOKE DETECTOR (IONIZATION TYPE) : PROVIDING &FIXING OF IONIZATION TYPE SMOKEDETECTORS AS PER IS: 11360-1985 OF DUAL CHA 512 HEAT DETECTOR : PROVIDING & FIXING OF HEAT DETECTOR BASED ON HEAT RATE-OF#RISE/FIXED TEMPERATUREWITH WORKING VOLTAGE 9-3 513 R.I. : PROVIDING & FIXING OF RESPONSE INDICATOR 514 MANUAL CALL POINT: PROVIDING & FIXING OF MANUAL CALLS POINT FLUSH OR SURFACEMOUNTING. FRONT PROTECTION GLASS COVER. UNBR 515 INTERNAL HOOTER: PROVIDING &FIXING OF INTERNAL HOOTER WITH WORKING AC VOLTAGE220V A.C./24V D.C. CURRENT CONSUMPTION, SOU 516 INDUSTRIAL HOOTER: PROVIDING & FIXING OF INDUSTRIAL HOOTER SPEAKER HORN TYPE ABSBODY WITH WORKING AC VOLTAGE 220V A.C./2 517 SUPPLY OF XLPE INSULATED 1.5 SQ. MM. ARMOURED 2 CORE FRLSZH FIRE ALARMCABLE (RED) FIRE SURVIVAL CABLE CONFORMING IS-7098 518 CURRENT RATING -25 TO100 AMPS & 70% -100% ADJUSTABLE 519 0.5 AMP TO 5 AMP RATING 520 6 AMP TO 32 AMP RATING 521 6 AMP TO 32 AMP RATING FOR TRIPLE POLE (TP) 522 FOR 40 AMPS. RATING ONLY. FOR TRIPLE POLE (TP) 523 50 AMP TO 63 AMP RATING FOR TRIPLE POLE (TP) 524 6 AMP TO 32 AMP RATING FOUR POLE(FP) 525 FOR 40 AMPS. RATING ONLY. FOUR POLE(FP) 526 50 AMP TO 63 AMP RATING FOUR POLE(FP) 527 FIXING OF MCB / ISOLATOR SP/DP IN SHEET STEEL ENCLOSURE AS REQUIRED AS PER ACCEPTED PRACTICE, INCLUDING MOUNTING ON BUS 528 FIXING OF MCB /MCCB ISOLATOR TP /TPN/FP IN SHEET STEEL ENCLOSUREAS REQUIRED AS PER ACCEPTED PRACTICE, INCLUDING MOUNTI 529 (40/.0076) THREE CORE 530 LARGE SIZE 531 SUPPLYING, FIXING,TESTING & COMMISSIONING WALL / FLOOR MOUNTED LT PANEL PRIMER COATED WITH TWO COAT OF ENAMEL PAINT & P 532 ALUMINIUM BUS BAR STRIPS WITH PVC SLEEVES 533 EARTHING WITH G.I. EARTH PLATE 600MM X 600MM X 6MM THICK INCLUDING ACCESSORIES AND PROVIDING MASONARY ENCLOSER IN CEMEN 534 ADD EXTRA FOR USING SALT AND CHARCOAL / COKE FOR G.I. PLATE OR COPPER PLATE EARTH ELECTRODE AS REQUIRED INCLUDING EXCAV 535 PROVIDING & FIXING 25MM X 5MM G.I.STRIP IN40MM DIA G.I. PIPE(BCLASS) FROM EARTH ELECTRODE AS REQUIRED. 536 PROVIDING AND FIXING 25MM X 4MM G.I. STRIP ON SURFACE OR INRECESSED/CONCEALED FOR CONNECTION ETC. AS REQUIRED. 537 PROVIDING AND FIXING 4.00MM G.I. WIRE ON SURFACE OR INRECESSED/CONCEALED FOR LOOP EARTHING AS REQUIRED. 538 4 METER HEIGHT 539 PROVIDING AND FIXING OF SWORD CANOPY TYPE SINGLE ARM GI BRACKET UPTO2 MTR. LONG FOR 70MM A/F TOP OCTAGONAL POLE 540 PROVIDING AND FIXING OF SWORD CANOPY TYPE DOUBLE ARM GI BRACKETUPTO 2 MTR. LONG FOR 70MM A/F TOP OCTAGONAL POLE 541 6 SQ.MM.(XLPE) ARMOURED 4 CORE 542 10 SQ.MM.(XLPE) ARMOURED 4 CORE 543 16 SQ.MM.(XLPE) ARMOURED 4 CORE 544 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3,3½ & 4 X UPTO 6SQ.MM 545 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3, 3½, 4 X 10 SQ.MMOR 2X 16 SQ.MM 546 GLAND SIZE 28MM SUITABLE FOR CABLE 3,4 X 16 SQ.MM 547 LUGS:-6MM TO 16 SQ.MM 548 COPPER LUGS PIN TYPE UPTO 16 SQ.MM CONDUCTOR SIZE 549 LAYING OF ONE NUMBER ADDITIONAL PVC INSULATED AND PVC SHEATHED POWER CABLE OF 1.1KV GRADE OF SIZE EXCEEDING 120 SQ MM B 550 LAYING OF ONE NUMBER PILC/PVC INSULATED AND PVC SHEATHED POWER CABLE OF GRADE EXCEEDING 1.1KV BUT NOT EXCEEDING 11KV OF 551 SUPPLYING ROUTE MARKER WITH 10CM X 10CM G.I. PLATE 5MM. THICK WITH INSPECTION THEREON BOLTED/WELDED TO 35MM X 35MMX 6MM 552 SUPPLYING, INSTALLING, TESTING OF EARTH COIL (COIL OF 115 TURNS OF 50MM DIA, AND 2.5MTRS. LEAD OF 4 MM G.I WIRE. 553 PROVIDING AND ERECTING 9 MTRS. HIGH HOT DIPPED GALVANIZED OCTAGONAL POLES WITH BOTTOM OF 200MM A/F, TOP 100MM, A/F MADE 554 DESIGNING & CASTING WITH M-20 CEMENT CONCRETE FOUNDATION SUITABLE FOR 9 MTRS. OCTAGONAL POLES CONSIDERING THE SAFE SOIL 555 100.00MM FOR B CLASS G.I.PIPE ISI MARKED (IS-1161-68) 556 150.00MM FOR B CLASS G.I.PIPE ISI MARKED (IS-1161-68) 557 75.00MM O.D 558 110.00MM O.D 559 50.00MM OUTSIDE DIA. 560 63.00MM OUTSIDE DIA. 561 110.00MM OUTSIDE DIA. 562 PORVIDING,ERECTING, TESTING AND COMMISSIONING SOLAR STREET LIGHT SYSTEM ON 80 MM HEAVY DUTY GALVANISED IRON PIPE 6 METE 563 40 WATT. 564 60W 565 10 W 566 30W 567 ASTRO TIME SWITCH-FOR LIGHTS ON – OFF BASED ON SUNRISE & SUNSET TIMING SUPPLY, INSTALLATION, TESTING AND COMMISSIONING 568 MODULAR CONTACTOR FOR THE LIGHTING FEEDER PANEL 569 CURRENT RATING -25 TO100 AMPS & 70% -100% ADJUSTABLE 570 CURRENT RATING -200 AMPS & 70% -100% ADJUSTABLE 571 CURRENT RATING -400 AMPS & ADJUSTABLE: 70% -100% THERMAL & 4-10 TIMES MAGNETIC SETTING 572 CURRENT RATING -500/630 AMPS & ADJUSTABLE: 70% -100% THERMAL & 4-10 TIMES MAGNETIC SETTING 573 CURRENT RATING -800 AMPS & ADJUSTABLE: 70% -100% THERMAL & 4-10 TIMES MAGNETIC SETTING 574 6 AMP TO 32 AMP RATING FOUR POLE(FP) 575 FOR 40 AMPS. RATING ONLY. FOUR POLE(FP) 576 50 AMP TO 63 AMP RATING FOUR POLE(FP) 577 FIXING OF MCB /MCCB ISOLATOR TP /TPN/FP IN SHEET STEEL ENCLOSUREAS REQUIRED AS PER ACCEPTED PRACTICE, INCLUDING MOUNTI 578 LARGE SIZE 579 SUPPLYING, FIXING,TESTING & COMMISSIONING WALL / FLOOR MOUNTED LT PANEL PRIMER COATED WITH TWO COAT OF ENAMEL PAINT & P 580 DIGITAL AMPERE METER WITH CTS WITH SELECTOR SWITCH 581 DIGITAL VOLT METER WITH SELECTOR SWITCH & HRC FUSE 582 ALUMINIUM BUS BAR STRIPS WITH PVC SLEEVES 583 LED LAMPS 584 EARTHING WITH G.I. EARTH PLATE 600MM X 600MM X 6MM THICK INCLUDING ACCESSORIES AND PROVIDING MASONARY ENCLOSER IN CEMEN 585 EARTHING WITH COPPER EARTH PLATE 600MM X 600MM X 3MM THICK INCLUDING ACCESSORIES AND PROVIDING MASONARY ENCLOSER IN CEM 586 ADD EXTRA FOR USING SALT AND CHARCOAL / COKE FOR G.I. PLATE OR COPPER PLATE EARTH ELECTRODE AS REQUIRED INCLUDING EXCAV 587 PROVIDING & FIXING 25MM X 5MM COPPER STRIP IN 40MM DIA G.I.PIPEFROM EARTH ELECTRODE AS REQUIRED. 588 PROVIDING & FIXING 25MM X 5MM G.I.STRIP IN40MM DIA G.I. PIPE(BCLASS) FROM EARTH ELECTRODE AS REQUIRED. 589 PROVIDING & FIXING 25MM X 5MM COPPER STRIP ON SURFACE ORRECESSED FOR CONNECTION ETC. AS REQUIRED. 590 PROVIDING AND FIXING 25MM X 4MM G.I. STRIP ON SURFACE OR INRECESSED/CONCEALED FOR CONNECTION ETC. AS REQUIRED. 591 H-BEAM 152X152MM , STD WEIGHT 37.1 KG PER METER 592 ACSR 6/1 - 4.09MM DIA (RACCOON) WITH EQUIVALENT COPPER AREA 48SQMM (0.075 SQ INCH) EQUIVALENT CALCULATED ALUMINIUM ARE 593 SUPPLYING AND DRAWING GUARD WIRE/EARTH WIRE/BEARER WIRE 13MM2 (4MM. DIA) G.I. INCLUDING STRINGING, BINDING AT EXISTING 594 ERECTION OF STEEL TUBULAR OR STEEL RAIL POLE OR H-BEAM OF LENGTH EXCEEDING 10 METERS BUT NOT EXCEEDING 13 METERS IN CEM 595 SUPPLYING OF ANGLE/CHANNEL FLAT IRON FITTING FOR OVERHEAD LINES SUCH AS CROSS ARMS, CLAMPS, BRACKETS, WELDING AND OTHER 596 SUPPLYING AND ERECTION OF GALVANISED STAY SET FOR 11KV OVERHEAD LINE COMPLETE WITH 19/20MM DIA X 1.8 METERS LONG STAY R 597 SUPPLYING AND ERECTION OF 11KV PIN INSULATOR COMPLETE WITH LARGESTEEL HEAD G.I. PIN, NUT, WASHER ETC. AS REQUIRED. 598 SUPPLYING AND ERECTION OF 11KV DISC INSULATOR FOR 11KV OVERHEAD LINES WITH GALVANISED INSULATOR FITTINGS, BALL AND SOCK 599 SUPPLYING AND ERECTION OF THREE PIECE NONLINEAR RESISTOR TYPE LIGHTING ARRESTOR SUITABLE FOR 3 WIRE, 11KV OVERHEAD LINE 600 ABOVE 9 MTR. 601 300 SQ.MM.(XLPE) ARMOURED 3½ CORE 602 LUGS:- 400 SQ.MM. 603 LAYING AND FIXING OF ONE NUMBER PVC INSULATED AND PVC SHEATHED ALUMINIUM CONDUCTOR CABLE OF 1.1KV GRADE OF SIZE EXCEEDI 604 SUPPLYING ROUTE MARKER WITH 10CM X 10CM G.I. PLATE 5MM. THICK WITH INSPECTION THEREON BOLTED/WELDED TO 35MM X 35MMX 6MM 605 11 KV 606 11KV 607 SUPPLYING, INSTALLING, TESTING OF EARTH COIL (COIL OF 115 TURNS OF 50MM DIA, AND 2.5MTRS. LEAD OF 4 MM G.I WIRE. 608 DRY CHEMICAL POWDER (DCP) TYPE- 5KG DULY REFILLED AND READY TO USE 609 ABC TYPE DULY REFILLED AND READY TO USED 610 DRY CHEMICAL POWDER (DCP) TYPE- 5KG REFILL ONLY 611 4 BUCKET SET WITH STAND AND SAND DULLY PAINTED RED 612 PROVIDING ,MAKING AND FIXING IN POSITION WINDOW FRAMES JET- BLACK GRANITE IN BLACK SHADE AND PATTERN OR IN COMBINATION, 613 PROVIDING AND LAYING CEMENT CONCRETE IN SUNKEN FLOORS OF WC, TOILETS, WASHAREAS ETC WITH 1:5:10 (1 CEMENT:5 COARSE SAND 614 PROVIDING AND LAYING C.C. PAVEMENT OF MIX M- 25 WITH READY MIXED CONCRETE FROM BATCHING PLANT INCLUDING CENTERING AND SH 615 PROVIDING AND FIXING FIRE RESISTANT DOOR FRAME OF SECTION 143X57 MM HAVING BUILTIN REBATE MADE OUT O 616 PROVIDING AND FIXING 50 MM THICK GLAZED FIRE RESISTANT DOOR SHUTTERS OF 60MINUTES FIRE RATING CONFORMING TO IS:3614 (PAR 617 EXTRA FOR PREFINISHED NOSING TO TREADS OF STEPS OF MARBLE STONE 618 (B) SIZE 600X600MM THICKNESS 9-10MM 619 ADD EXTRA FOR TILE LAYING WITH SPACERS AND FILLED BY GROUTING THE JOINTS OF FLOORING/ SKIRTING / WALL DADO/ RISER OF STE 620 SIZE 800X800MM THICKNESS 9-10 MM 621 SIZE 800X800MM THICKNESS 9-10 MM 622 ADD EXTRA FOR TILE LAYING WITH SPACERS AND FILLED BY GROUTING THE JOINTS OF FLOORING/ SKIRTING / WALL DADO/ RISER OF STE 623 GRANITE DOOR FRAME FOR 200MM THICK WALL THICKNESS 624 GRANITE DOOR FRAME FOR 100MM THICK WALL THICKNESS 625 9.66.3 150X10 MM 626 250X20X6 MM 627 PROVIDING AND FIXING STAINLESS STEEL HANGING TYPE FLOOR DOOR STOPPER WITHNECESSARY SCREWS, ETC. COMPLETE. 628 125 MM 629 250X16 MM 630 PROVIDING AND FIXING CHROMIUM PLATED BRASS NIGHT LATCH INCLUDING NECESSARYSCREWS ETC. COMPLETE (BEST MAKE OF APPROVED QU 631 FIXED WINDOW / VENTILATOR MADE OF (SMALL SERIES) FRAME 47 X 50 MM & MULLION 47 632 THREE TRACK THREE PANELS SLIDING WINDOW WITH FLY PROOF SS WIRE MESH (TWO NOS.GLAZED & ONE NO. WIRE MESH PANELS) MADE OF 633 THREE TRACK THREE PANELS SLIDING WINDOW WITH FLY PROOF S.S WIRE MESH (TWO NOS.GLAZED & ONE NO. WIRE MESH PANELS) MADE OF 634 PAINTING WITH SYNTHETIC ENAMEL PAINT OF APPROVED BRAND AND MANUFACTURE TOGIVE AN EVEN SHADE: TWO OR MORE COATS ON NEW WO 635 SIZE 600X1200 MM THICKNESS 9-10 MM 636 SIZE 800X800MM THICKNESS 9-10 MM 637 SIZE 600X1200 MM THICKNESS 11-12MM 638 SIZE 600X1200 MM THICKNESS 9-10 MM 639 SIZE 800X1200 MM THICKNESS 9-10 MM 640 SIZE 600X1200 MM THICKNESS 9-10 MM 641 ADD EXTRA FOR TILE LAYING WITH SPACERS AND FILLED BY GROUTING THE JOINTS OF FLOORING/ SKIRTING /WALL DADO/ RISER OF STEP 642 PROVIDING AND PLACING IN POSITION SUITABLE PVC WATER STOPS CONFORMING TOIS:12200 FOR CONSTRUCTION/ EXPANSION JOINTS BETW 643 PROVIDING AND FIXING PRE-MOULDED JOINT FILLER IN EXPANSION JOINTS OF RCCROADS / CC PAVEMENTS AFTER M 644 10MM THICK 645 PROVIDING AND FIXING HEAT RESISTANT TERRACE TILES (300 MM X 300 MM X 20 MM)WITH SRI (SOLARREFRACTIVE INDEX)> 78, SOLAR R 646 PROVIDING AND LAYING LAPPATO FINISHED GRANITE STONE FLOORING/STRIPS IN REQUIREDDESIGN, COLOUR AND PATTERNS IN LINEAR AS 647 PROVIDING AND FIXING SS CLOSED BODY MORTISE LOCK WITH DEAD BOLT & LATCH BOLDORSET,DORMA,OZONE,GODREJ OR EQUIVALENT AS PE 648 PROVIDING AND FIXING L SHAPE MORTICE HANDLE SS FINISH(DORSET,DORMA,OZONE,GODREJ OR EQUIVALENT AS PER APPROVED ISI MAKE ) 649 SUNLIGHT COLLECTOR CUTOUT A SINGLE 800MM/300MM 650 SUNLIGHT TWIN COLLECTOR CUTOUT A 800MM/300MM 651 SUNLIGHT COLLECTOR CUTOUT B SINGLE 800MM/300MM 652 SUNLIGHT COLLECTOR CUTOUT C SINGLE 800MM/300MM 653 SUNLIGHT TWIN COLLECTOR CUTOUT C 800MM/300MM 654 PROVIDING & FIXING OF RUBBER COLUMN GUARD WITH REFLECTIVE STRIPS FOR HIGH NIGHTTIME VISIBILITY SIZE 655 PROVIDING AND FIXING OF ISI MARKED STAINLESS STEEL 304 GRADE DOOR LOCK OF BRASSFINSH OF 10-12 MMSIZE WITH NECESSARY SCRE 656 25 MM DIA X 600 MM 657 PROVIDING AND FIXING GLAZING IN UPVC DOOR, WINDOW, VENTILATOR SHUTTERS ANDPARTITIONS ETC. WITH EPDM RUBBER/ NEOPRENE GAS 658 PROVIDING AND FIXING OF ROLLING SHUTTER APPROVED MAKE, MADE OF REQUIRED SIZEALUMINIUM PROFILE PERFOR 659 TEXTURE PAINT: PROVIDING AND APPLYING EXTERIIOR TEXTURE PAINT OF SUPERPERKIFINE QUALITY, IT SHALL BE APPLIED AFTER PREPA 660 PROVIDING & FIXING 6 MM THICK DECORATIVE HIGH PRESSURE LAMINATED SHEET OF PLAIN/ WOOD GRAIN IN GLOSS / MATT / SUEDE FINI 661 PROVIDING & FIXING OF KOTA STONE 25 MM THICK FOR THE BASE OFKITCHEN/PANTRY/TOILET PLATFORM OF ANY SI 662 G.S. SHEET 663 TAKING OUT EXISTING CC INTERLOCKING PAVER BLOCKS FROM FOOTPATH/ CENTRAL VERGE,INCLUDINGREMOVAL OF RU 664 TAKING OUT EXISTING KERB STONES OF ALL TYPES FROM FOOTPATH/ CENTRAL VERGE, INCLUDINGREMOVAL OFMORTAR ETC., DISPOSAL OF U 665 PROVIDING AND FIXING FACTORY MADE PRECAST RCC PERFORATED DRAIN COVERS, HAVINGCONCRETE OF STRENGTH NOT LESS THAN M-25, OF 666 SUPPLYING, FILLING, SPREADING AND LEVELING GRAVELS OF SIZE RANGE 5 MM TO 10 MM,IN THE RECHARGE PIT, OVER THE EXISTING LA 667 SUPPLYING, FILLING, SPREADING AND LEVELING COARSE SAND OF SIZE RANGE 1.5 MM TO 2MM INRECHARGE PIT, IN REQUIRED THICKNESS 668 110 MM DIAMETER PVC PIPE, HAVING WALL THICKNESS 3.2 MM FOR 250 M2CATCHMENT ARE 669 PROVIDING AND FIXING OF NAME PLATE FOR OFFICES NAME OF STAINLESS STEEL PLATE 304GRADE OF 1.50MM THICK, INCLUDING WRITING 670 PROVIDING AND FIXING OF SIGNAGE IN IMPORTED CAST ACRYLLIC SHEET OF THICKNESS3MM WITH ACCESSORIES PAST IN ADHESIVE . AS P 671 PROVIDING AND FIXING LED BACKLIT SIGNAGE MADE OUT FROM 3 MM THICK COLOUREDACRYLIC SHEET AND DEPTH OF THE LETTER IS 100 M 672 WITH PRECONTRAINT TENSILE MEMBRANE 1050 GSM (20 YEARS WARRANTY) 673 (C) SIZE 600X600 MM THICKNESS 11-12MM (TO BE USED HEAVY DUTY INDOOR AREAS OF NON RESIDENCIAL BUILDINGS ONLY SUCH AS SCHO 674 IN DARK COLOUR AND SHADE ETC. 675 FLOORING WITH MIRROR POLISH BLACK BASALT STONE OF APPROX. 20 MM (THICK) LAID ON 25 MM AVERAGE THICK CEMENT MORTAR 1:3 ( 676 TRENCHING IN ORDINARY SOIL UP TO A DEPTH OF 60CM INCLUDING REMOVAL AND STACKING OF SERVICEABLE MATERIALS AND THEN DISPOS 677 TRENCHING IN ORDINARY SOIL UP TO A DEPTH OF 60CM INCLUDING REMOVAL AND STACKING OF SERVICEABLE MATERIALS AND THEN DISPOS 678 ALPINIA VERIGATED, ALTERNANTHERA SPECIES, ASPYRAGUS MYERRI, ASPYRAGUS SPRINGENII, ASPIDISTRA, CANNA (REGULAR, DWARF), C 679 ANY OF ONE FROM ALYSSUM, ANEMONE, ANTIRRHINIUM HYBRID, ASTER HYBRID, BEGONIA AND ITS DIFFERENT VARIETIES, CALENDULA, CAR 680 ANY OF ONE FROM CELOSIA, CALADIUM HYBRID, COCKSCOMB, COSMOS, GAILLARDIA, GOMPHORENA, KOCHCHEA, PORTULACCA, SUNFLOWER HYB 681 BUDDED ROSES OF H.T VARIETY AND MINIATURE ROSES 682 PREPARATION OF MOUNDS OF VARIOUS SIZE AND SHAPE BY AVAILABLE EXCAVATED /SUPPLIED EARTH IN LAYERS NOT EXCEEDING 20 CM IN 683 PROVIDING AND FIXING OF WHITE MARBLES CIRCULAR/OVAL IN SHAPE (STONE) PEBBLES OF SIZE 2TO 2.50 DIA IN NATURAL COLOUR AT 684 PROVIDING AND PLACING IN POSITION 150MM DIA BOLLARDS 900 MM HIGH OF REQUIRED SHAPE INCLUDING PROVIDING BASE PLATE 210 MM 685 PROVIDING & FIXING OF LENGTH :- 6 MTR. LED (ELECTRO MECHANICAL, MOTORISED WITH 06 METER BOOM (ALUMIN 686 32 MM DIA NOMINAL BORE 687 40M DIA NOMINAL BORE 688 FIXING FULLY AUTOMATIC NO TOUGH HAND DRYER SUITABLE TO OPERATE ON 230 VOLTS, SINGLE PHASE,50 HZ AC POWER SUPPLY COMP 689 200 MM DIA 690 150 MM DIA 691 100MM DIA 692 80 MM DIA 693 65 MM DIA 694 50 MM DIA 695 40 MM DIA 696 320MM DIA 697 75 MM DIA 698 100 MM DIA 699 COUPLER 75 MM 700 COUPLER 110 MM 701 SINGLE PUSHFIT COUPLER 75 MM 702 SINGLE PUSHFIT COUPLER 110MM 703 SINGLE TEE WITH DOOR75X75X75 MM 704 SINGLE TEE WITH DOOR 110X110X110 MM 705 SINGLE TEE WITHOUT DOOR75X75X75 MM 706 SINGLE TEE WITHOUT DOOR110X110X110 MM 707 BEND 87.5075 MM BEND 708 BEND 87.50 110 MM BEND 709 REDUCER100X75 710 100 MM 711 75 MM 712 110 MM 713 160 MM 714 COUPLER110 MM 715 COUPLER 160 MM 716 45 BEND 110 MM 717 45 BEND 160 718 CLEAN OUT PLUG 110 MM 719 CLEAN OUT PLUG 160 MM 720 PROVIDING AND FIXINGOIL & GREASE TRAP INCLUDING FITTINGS AND BRACKETS, CUTTING AND MAKING GOOD THE WALLS & UNDER G 721 FLOW RATE : 22 CUM/HR. EACH (1W+1S=1SET) 722 CAPACITY : 8 M3/HR. 723 CAPACITY : 8 M3/HR. 724 CAPACITY : 8 M3/HR. 725 SUPPLYING, INSTALLING, TESTING AND COMMISSIONING OF CHLORINE DOSING SYSTEM (FOR DOMESTIC WATER TREATMENT PLANT) CONSISTI 726 SUPPLY, INSTALLING, TESTING AND COMMISSIONING OF ANNUNCIATION AND INDICATION PANEL WITH INTERLOCKING ARRANGEMENT COMPLET 727 PROVIDING, FIXING, TESTING & COMMISSIONING PRESSURE SWITCH FOR WATER PUMPS TO START/STOP THE PUMP AT SET PRESSURE. INCLU 728 SUPPLY, INSTALLING, TESTING AND COMMISSIONING OF LEVEL CONTROLLERS FOR WATER PUMPS TO START/STOP THE PUMP AT SET LEVEL. 729 100 MM DIA 730 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ELECTRIC PANEL AS PER SLD & TECHNICAL SPECIFICATION. THE SCOPE ALSO I 731 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ELECTRIC PANEL AS PER SLD & TECHNICAL SPECIFICATION. THE SCOPE ALSO I 732 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ELECTRIC PANEL AS PER SLD & 733 1500 LITERS TANK CAPACITY 734 200 MM 735 150 MM 736 100 MM 737 80 738 50 MM 739 25 MM 740 FIRE LIFT SIZE: 4 X 12 741 FIRE HYDRANT LINE -5 X12 742 SPRINKLER HYDRANT LINE -5 X12 743 FIRE EXIT - 5 X12 744 CO2 EXTINGUISHER - 8 X16 745 ABC EXTINGUISHER - 8 X16 746 CO2 EXTINGUISHERS: SIZE: 8 X 16 747 ABC EXTINGUISHERS SIZE: 8 X 16 748 MECHANICAL FOAM EXTINGUISHER SIZE: 8 X 16 749 IN CASE OF FIRE, DO NOT USE LIFT, USE STAIRCASESIZE: 8 X 8 750 9 LITRES 751 50 MM 752 PROVIDING, FIXING, TESTING & COMMISSIONING OF AUTOMATIC AIR RELEASE VALVE WITH 15MM DIA STOP COCK, FLANGED INLET CONNECT 753 PROVIDING, FIXING, TESTING & COMMISSIONING OF STANDARD FIREMANS AXE WITH HEAVY RUBBER HANDLE. 754 PROVIDING, FIXING, TESTING & COMMISSIONING OF 100MM M.S. CLASS C DIESEL PUMP EXHAUST PIPE INCLUDING ALL FITTINGS LIKE 755 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ELECTRIC PANEL AS PER SLD & TECHNICAL SPECIFICATION. THE SCOPE ALSO I 756 PROVIDING, FIXING, TESTING & COMMISSIONING OF AUTOMATIC AIR RELEASE VALVE WITH 15MM DIA STOP COCK, FLANGED INLET CONNECT 757 PROVIDING, FIXING, TESTING & COMMISSIONING OF STANDARD FIREMANS AXE WITH HEAVY RUBBER HANDLE. 758 9 W 759 12/15 W 760 22/24 W 761 FLEXIBLELEDSTRIP24WATT/25WATT -5MINDOORCOVELIGHTW/O DRIVER IP 20-33 762 FLEXIBLE LED STRIP 72WATT/75WATT - 5 M INDOOR LIGHT W/O DRIVER IP 20 - 33 763 POWER SUPPLY 25WATT/30WATTFOR LED STRIP IP25/IP33 764 POWER SUPPLY 72WATT/75WATTFOR LED STRIP IP25/IP33 765 SUPPLY, FIXING AND TESTINGOF APPROVED MAKE INTEGRALSTEP/SKIRTLED LIGHT SUITABLE FOR 3 MODULE BOX AND PLATE INCLUDI 766 10 PAIR 767 20 PAIR 768 30 PAIR 769 40 PAIR 770 SUPPLY, FIXING AND TESTING OF RJ 11 TELEPHONE JACK MODULAR (1 MODULE) 771 SUPPLY, FIXING AND TESTING OF T.V. OUTLET MODULAR (1MODULE) 772 RJ - 45 COMPUTER SOCKET CAT 6 WITH SHUTTER MODULAR (1MODULE) 773 SUPPLYING AND DRAWING 4 PAIR SHIELDED TWISTED PAIR (STP), 0.5 MM PVC INSULATED COPPER CONDUCTOR UN-ARMOURED CAT-6 COMPUT 774 CAT 6 RJ45 PATCH CORD UTP 1 METRE 775 SUPPLY, INSTALLATION TESTING AND COMMISSIONING OF 19 MODULAR TELEPHONE PATCH PANEL 24 - 1 U WITH RJ 11 CONNECTOR 776 6U CABINET 300X600X500, WALL MOUNTING WITH 6 POINT 5 AMP. SOCKET POWER SUPPLY STRIP AND FAN, TRAY. 777 12U CABINET 600X600X500, WALL MOUNTING WITH 6 POINT 5 AMP. SOCKET POWER SUPPLY STRIP AND FAN, TRAY. 778 30U CABINET 1350X600X600, FLOOR MOUNTING WITH POWER SUPPLY AND FAN, TRAY. EQUIPMENT SUPPORT ANGLE, VERTICAL CABLE MANAGE 779 2.5 SQ. MM. 780 6 SQ. MM. 781 10 SQ. MM. 782 16 SQ. MM. 783 6 SQ. MM. 784 10SQ. MM. 785 16 SQ. MM. 786 25 SQ. MM. 787 2.5 SQ. MM. 788 2.5 SQ. MM. 789 150 X 50 X 1.6MM THICK 790 300 X 50 X 1.6MM THICK 791 600 X 50 X 2 MM THICK 792 PIR MOVEMENT DETECTOR–FOR CORRIDORS, COMMON ROOMS, STAIR CASES, STORE ROOM, 793 PIR MOVEMENT DETECTOR–FOR CORRIDORS, COMMON ROOMS, STAIR CASES, STORE ROOM, 794 PIR MOVEMENT DETECTOR–FOR CORRIDORS, COMMON ROOMS, STAIR CASES, STORE ROOM, WASHROOM 795 SUPPLY AND FIXING OF IP 65, SURFACE WALL MOUNTED 9W LED UP/DOWNLIGHTER DECORATIVE WALL LIGHT FIXTURE 796 6W RECESS DEEP UPLIGHT 797 5W PER METER 798 SUPPLYANDFIXINGOFDECORATIVERECESSEDWALL MOUNTED 6WASYMMETRIC LEDSTEPLIGHT4X4 15-18DEG LUMINA 799 SUPPLY AND FIXING IP65 SURFACE WALL MOUNTED 6W 4 WAY GRAZER 3X3 LED FIXTURE FITTED WITH 700MA 8DEG-15 DEG 3000K-4000K 800 2 MP IP IR EYEBALL CAMERA WITH H.264VIDEO COMPRESSION 801 2 MP IP IR BULLET CAMERA WITH H.264 VIDEO COMPRESSION 802 32 CHANNEL NVR WITH 4 SATA 803 8 PORT POE SWITCH WITH 2 SFP PORTS 804 24 PORT POE SWITCH WITH 4 SFP PORTS 805 CCTV COLOUR MONITOR 806 PROVIDING &FIXING OF 4 TB HARD DISK 807 SUPPLYING AND DRAWING 4 PAIR SHIELDED TWISTED PAIR (STP), 0.5 MM PVC INSULATED COPPER CONDUCTOR UN-ARMOURED CAT-6 COMPUT 808 8 ZONE IP BASED DIGITAL VOICE ALARM CONTROLLER 809 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 8 ZONE IP BASED, DIGITAL VOICE ALARM CONTROLLER EXPANDABLE UPTO 128 Z 810 1000W POWER AMPLIFIER 811 10W WALL MOUNT SPEAKER 812 (24/0.2 MM) TWIN CORE 0.75 SQ.MM. 813 (32/0.2 MM) TWIN CORE 1.00 SQ.MM. 814 FOR 30 MINUTE BACKUP, MIN. 800VAH 815 13 PASSENGER (884KG.) 816 FOR HIGHER SPEED 1.5 METRE/SEC (FOR 13-26 PASSENGERS) 817 COSTFOREACHADDITIONALFLOOR:UPTO9STOPS(FOR13-26 PASSENGERS) 818 EXTRA COST FOR PER FLOOR PER LIFT 819 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF DIESEL GENERATING SET THREE PHASE, WATER COOLED WITH AMF CONTROL PANE 820 2.5 SQ. MM. 821 SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF ON GRID SOLAR PHOTO VOLTAIC POWER PLANT CONFORMING TO MNRE SPECIFICAT 822 UNARMOURED 4 CORE 2.5 SQ. MM. 823 3W RECESS DEEP UPLIGHT 824 6W RECESS DEEP UPLIGHT 825 SUPPLY AND FIXING IP65 SURFACE WALL MOUNTED 6W 4 WAY GRAZER 3X3 LED FIXTURE FITTED WITH 700MA 8DEG-15 DEG 3000K-4000K 826 BOLLARDLED8-10WATTCYLINDRICALSHAPEHEIGHT>700MM,COLOR TEMP 3000-6000K 827 FLEXIBLELED STRIP72WATT/75WATT-5MOUTDOORLIGHTW/ODRIVER IP65 828 POWER SUPPLY 72WATT/75WATTFOR LED STRIP IP65 829 PACKAGE TRANSFORMER : 315KVA, 11KV/433V, DYN11, DRY TYPE, COPPER WOUND TRANSFORMER FOR HT & LT WITH OFF LOAD TAP LINKS , 830 EXTRA FOR PROVIDING AND MIXING WATER PROOFING MATERIAL AS PER IS STANDARD IN CEMENT CONCRETE WORK. QTY AS PRESCRIBED BY 831 ADD EXTRA FOR PROVIDING REINFORCEMENT ABOVE FLOOR TWO LEVEL FOR EVERY ADDITIONAL FLOOR OR PART THEREOF. 832 PROVIDING AND LAYING FACTORY MADE COLOURED CHAMFERED EDGE CEMENT CONCRETE PAVER BLOCKS OF REQUIRED S 833 PROVIDING AND FIXING 16MM THICK GANG SAW CUT MIRROR POLISHED PREMOULDED AND 834 FLAMED FINISH GRANITE
|